Determination of Pd, Cd, Cr, Cu, Sb in Synthetic Leather ZHAO, Yang (China Leather and Footwear Industry Research Institute, Beijing 100015, China) Abstract:An effective method for the determination of heavy metals in Synthetic Leather by ICP-OES with microwave digestion was developed in this paper. Samples of Synthetic Leather were digested with high throughput microwave chemistry workstation in nitric acid, hydrogen peroxide and fluorhydric acid mixed system, the boric acid is used to eliminate the effect of fluorhydric acid and quantified by ICP-OES. The result shows that the limit of detection was 0.0019~0.043μg/mL, the average recoveries at three levels ranged form 88.5%~102.8%, the relative standard deviations were lower than 6.3% after microwave digestion and ICP-OES analytical condition were optimized. The method has the advantage of simplicity, high sensitivity, wide range of linear and small distraction. The determined results are accurate and the reproducibility is good. It has been applied to routine determination of heavy metals in synthetic leather with satisfactory results. Key words: synthetic leather; heavy metals; microwave digestion; ICP-OES Determination of Heavy Metals in Leather Protein Hydrolyzate by ICP-OES with Microwave Digestion ZHAO Yang*,QI Xiao-xia (China Leather and Footwear Industry Research Institute, Beijing 100016, China) Abstract : An effective method for the determination of heavy metals in leather protein hydrolyzate by ICP-OES with microwave digestion was developed in this paper. Samples of leather protein hydrolyzate were digested with high throughput microwave chemistry workstation in nitric acid and hydrogen peroxide mixed system and quantified by ICP-OES. The result shows that the limit of detection was 0.009~0.341mg/kg, the average recoveries of heavy metals in leather protein hydrolyzate at three levels ranged form88.8%~99.4%, the relative standard deviations were lower than 6.5% after microwave digestion and ICP-OES analytical condition were optimized. The method has the advantage of simplicity, high sensitivity, wide range of linear and small distraction. The determined results are accurate and the reproducibility is good. It has been applied to routine determination of heavy metals in leather protein hydrolyzate with satisfactory results. Key words:microwave digestion; ICP-OES; heavy metal; leather; protein hydrolyzate To Detect CODcr in Waste Water with Microwave Digestion-AEP Titrimeter Ye Shucai,Chen Zhihong (Zhongshan Environmental Monitoring Station, Zhongshan) Abstract: To detect CODcr in waste water with microwave digestion-AEP titrimeter . To digest water sample using H2SO4-K2Cr2O7-KAl(SO4)2-(NH4)6Mo7O24 first , the best digestion condition was get . Carries on the opposite experiment through the microwave resolution and the traditional backflow resolution, not only discovers the former to be able to be complete the sample resolution, saves the massive time compared to the latter, raises the analysis speed greatly. The automatic electrometric titration and the manual titrate compare, can obtain better picks out limits, the accuracy, the accuracy and the returns-ratio Keywords: microwave resolution ; automatic electric potential titrimeter ; chemical oxygen demand Determination of Trace Arsenic in Sewage Water by Hydride Generation—Atomic Fluorescence Spectrometry Digested with Microwave Yao Guo,Wang Jian wei (Dongguan Sewage Treatment Plant,Dongguan Guangdong,523080) Abstract : Object : The determination of trace arsenic in sewage water by hydride generation—atomic fluorescence spectrometry digested with microwave was studied. Method: the sewage samples were digested by nitric acid— perchloric acid. After adding thiourea— ascorbic acid into the medium of hydrochloric and potass borohydride —sodium hydroxide as the reducing agent. the sewage waters were determinate by hydride generation—atomic fluorescence spectrometry .Result: The detection limit of the method was less than 0.02μg/Land RSD was 0.14%.The recovery rates of the method was 92%~108%.Conclusion:The determination way is simple and the result is correct and good repetition. Key words: microwave digestion,hydride generation,atomic fluorescence,sewage water,arsenic Application of Microwave Digestion Technology in Environmental Monitoring Yin Wei1 Liu Changkuan2 (1Beijing Chemical Engineering Research Institute, Beijing 100022 ) (2China Analytical Instrument Branch, Beijing 100081 ) Abstract: Application of microwave digestion technology in the analytical chemistry has brought analytical laboratories a new revolution. The transfer methods of microwave energy are more efficient and cleaner than the traditional heating methods. So microwave digestion technology is widely used soon. This paper summarized how microwave digestion used in environmental monitoring field, including measuring heavy metals in the soil, solid waste, sediment and COD in the wastewater. Now microwave digestion technology has been widely used in many environmental monitoring laboratories. Key Words: Microwave, Digestion, Environmental monitoring