OHS017 OHS Risk Assessment and Control Form Risk assessment completed by: Sinead O’Reilly Staff/student number:s3244595 Faculty/Division: Medicine Document number STGCL.RA.30.1 School/Unit: St George Clinical School Initial Issue date 05/03/2010 Current version 1.0 Current Version Issue date: 05/03/10 Next review date: March 2012 For additional information refer to the OHS Risk Assessment and Control Procedure, the OHS Risk Rating Procedure and the Hierarchy of Risk Controls. Risk Assessment title: Operation of centrifuge Step 1: Identify the activity Describe the activity: Set up of the centrifuge: 1. Switch the power on 2. Select the correct rotor to use, place the rotor into the centrifuge and secure to the shaft 3. Select the correct adaptors, place the adaptors into the rotor or buckets 4. Fill & Balance the Tubes - tubes placed opposite to each other must be balanced 5. Place tubes in correct position in rotor 6. Use the lids for buckets if available, if spinning Biohazardous material to contain any contamination due to aerosol or alternatively move the rotor to the Biological Safety Cabinet and remove the samples in the Biological Safety Cabinet 7. Set the spin parameters ie speed, temperature, brake intensity 8. Close the lid & press start 9. After the spin, open the lid and remove the spun samples Describe the location: Cell Culture Lab Lab, Rm 3.17, Lab 3.15, Lab 3.21 Level 3, Research & Education Centre, 4-10 South St, Kogarah, NSW 2217 __________________________________________________________________________________________________________________________________________________________________________ Page 1 of 5 Risk Assessment and Control Form Date Effective: 01/01/2007 Uncontrolled document when printed Current Version: 2.6, 16/07/2008 Step 2: Identify who may be at risk by the activity The person operating the centrifuge, co-workers in the relevant Lab Steps 3 to 7: Identify the hazards, risks, and rate the risks 1. An activity may be divided into tasks. For each task identify the hazards and associated risks. 2. List existing risk controls and determine a risk rating using the UNSW Risk Rating Procedure. 3. Additional risk controls may be required to achieve an acceptable level of risk. Re-rate the risk if additional risk controls used. NOTE: ALL ASSOCIATED RISKS MARKED WITH * HAVE NO RISK RATING INCLUDED IN THIS RISK ASSESSMENT BECAUSE THE RISK DEPENDS ON THE SPECIFIC NATURE OF THE SAMPLE BEING SPUN. THIS RISK NEEDS TO BE ASSESSED, CONTROLLED AND DOCUMENTED BY THE INDIVIDUAL RESEARCHER FOR THEIR OWN SPECIFIC RESEARCH PROJECT Tasks Hazards Associated risks (Step 3) (Step 4) Risk rating with existing controls * Additional risk controls required Risk Rating with additional controls * (Step 5) (Step 6) (Step 7) Existing risk controls C L R Switching Power On Electrical Electrocution Fuses in plug. Electrical Testing & Tagging done and passed. 1 E L Selection of rotor and securing the rotor into the centrifuge Rotor not secured properly Severe machine vibrations. Damage to machine / rotor, Injury to person in the vicinity Training provided by Invitro Technologies – supplier of this machine. 5 E M Selection of correct adaptors & Placement of rotors into adaptors/ buckets None None N/A 1 E L Selection of correct Tubes for the type of samples being spun and for the volume required to be centrifuged incompatible tubes selected Leakage of samples during spin.* Group consulted regarding chemical resistance and speeds required. Appropriate tubes provided on the basis of the needs of the group Chemicals can corrode tubes* Tubes collapse during spin (Apply the hierarchy of risk controls) C L R __________________________________________________________________________________________________________________________________________________________________________ Page 2 of 5 Risk Assessment and Control Form Date Effective: 01/01/2007 Uncontrolled document when printed Current Version: 2.6, 16/07/2008 Fill & Balance the Tubes / adaptors - tubes/adaptors placed opposite to each other must be balanced. Chemical / Biohazard Hazard (depends on the composition of the liquid to be centrifuged) Chemical / Biohazard Exposure* Use MSDS / Datasheet to get information pertaining to the liquid to be centrifuged. Use PPE as per this information Place BALANCED tubes / adaptors in correct position in rotor ie OPPOSITE each other If this is not done correctly, the centrifuge run will be imbalanced Severe machine vibrations. Damage to machine / rotor, Injury to person in the vicinity, Engineering control built into machine so that it will stop running if the load is imbalanced 5 E M Use lids for buckets, where available if spinning Biohazardous material to contain any contamination due to aerosol None None N/A 1 E L Set the spin parameters ie speed, temperature, brake intensity If this is not done correctly, the samples will not be spun to the required speed / time / temperature Loss of samples, Damage to tubes if tubes spun at a rating that is too high Follow Safe Work Procedure Provided 1 E L Close the Lid and press start None – if there is a set up problem or a machine malfunction the machine will run to a low speed and then cut out or will not start at all but will display an error message Samples not spun N/A 1 E L After the spin, open the lid and remove the spun samples Potential for injury to hands / fingers. The machine cannot be opened automatically unless the rotor has stopped spinning Engineering control 1 E L * C = consequence L = likelihood R = risk rating from the UNSW Risk Rating Procedure __________________________________________________________________________________________________________________________________________________________________________ Page 3 of 5 Risk Assessment and Control Form Date Effective: 01/01/2007 Uncontrolled document when printed Current Version: 2.6, 16/07/2008 Step 8 Documentation and supervisor approval Completed by: Sinead O’Reilly (signature) Authorised by: Prof Michael Grimm Head of School, (signature) Date: 05/03/10 Reviewed by: (signature) Authorised by: Date: Reviewed by: (signature) Authorised by: Date: Reviewed by: (signature) Authorised by: Date: Reviewed by: (signature) Authorised by: Date: Reviewed by: (signature) Authorised by: Date: Step 9: Implement the additional risk controls identified Indicate briefly what additional risk controls from Step 6 above were implemented, when and by whom. Risk control: Date: Implemented by: Risk control: Date: Implemented by: Risk control: Date: Implemented by: Risk control: Date: Implemented by: Step 10: Monitor and review the risk controls It is important to monitor risk controls and review risk assessments regularly. Review is required when there is a change in the process, relevant legal changes, and where a cause for concern has arisen. Reviews could be scheduled on an annual basis. If the risk assessment has substantially changed a new risk assessment is warranted. Review date: Reviewed by: Authorised by: Review date: Reviewed by: Authorised by: Review date: Reviewed by: Authorised by: Review date: Reviewed by: Authorised by: Documentation It is a requirement that legal and advisory documentation that supports this risk assessment be listed. Such documentation includes Acts, Regulations, Australian Standards and Codes of Practice, where applicable. Manufacturer’s Instruction Manuals for Centrifuges __________________________________________________________________________________________________________________________________________________________________________ Page 4 of 5 Risk Assessment and Control Form Date Effective: 01/01/2007 Uncontrolled document when printed Current Version: 2.6, 16/07/2008 UNSW Concise OHS Risk Rating Table OHS697 What you need to do 1. Consider what can go wrong that can hurt someone 2. Determine what the most likely outcome would be - Consequences 3. Determine how likely those consequences are - Likelihood 4. Calculate the risk rating 5. Required action CONSEQUENCES: Severe Major Moderate Minor Insignificant LIKELIHOOD: Almost certain Likely Possible Unlikely Rare How severely could someone be hurt death or permanent disability to one or more persons hospital admission required medical treatment required first aid required injuries not requiring first aid How likely are those consequences? expected to occur in most circumstances will probably occur in most circumstances could occur at some time is not likely to occur in normal circumstances may occur only in exceptional circumstances CONSEQUENCES Insignificant 1 Minor 2 Moderate 3 Major 4 Severe 5 M H H VH VH M M H H VH Possible C L M H H VH Unlikely D L L M M H Rare E L L M M M LIKELIHOOD Almost certain A Likely B Risk level Very high High Medium Low Required action Act immediately: The proposed task or process activity must not proceed. Steps must be taken to lower the risk level to as low as reasonably practicable using the hierarchy of risk controls. Act today: The proposed activity can only proceed, provided that: (i) the risk level has been reduced to as low as reasonably practicable using the hierarchy of risk controls; (ii) the risk controls must include those identified in legislation, Australian Standards, Codes of Practice etc. (iii) the risk assessment has been reviewed and approved by the Supervisor and (iv) a Safe Working Procedure or Safe Work Method has been prepared. (v) The supervisor must review and document the effectiveness of the implemented risk controls. Act this week: The proposed task or process can proceed, provided that: (i) the risk level has been reduced to as low as reasonably practicable using the hierarchy of risk controls; (ii) the risk assessment has been reviewed and approved by the Supervisor and (iii) a Safe Working Procedure or Safe Work Method has been prepared. Act this month: Managed by local documented routine procedures which must include application of the hierarchy of controls. _______________________________________________________________________________________________________________ Page 5 of 5 UNSW Concise OHS Risk Rating Table Effective date: 01/01/2007 Uncontrolled document when printed Current Version: 2.6,16/07/2008