SOLAR SPECIFICATION 01 - General 01 – 01 Scope All solar hot water pipework and associated fittings shall be insulated. 01 – 02 Standard References The materials, components and completed installations shall conform to applicable Standards current at the time of tendering. Relevant standards may include: BS 476 BS EN 12667 BS 3533 BS 5970 BS 5422 EN 13501-1 Fire Tests on Building Materials and Structures. Thermal performance of building materials and products. Determination of thermal resistance by means of guarded hot plate and heat flow meter methods. Products of high and medium thermal resistance. Glossary of terms relating to thermal insulation. Thermal insulation of pipework and equipment in the temperature range of -100°C to + 870°C Method for specifying thermal insulation materials for pipes, tanks, vessels, ductwork and equipment operating within the temperature range -40°C to +700°C. Fire classification of construction products and building elements. Classification using test data from reaction to fire tests. 01 – 03 Services to be Insulated All solar hot water pipework and associated fittings shall be insulated. The installation work shall be carried out by suitably trained insulation contractors. 02 – Materials 02 – 01 General All insulation materials shall be:Obtained, where available from an ISO 9001:2000 “quality systems” and ISO 14001:2004 “environmental systems” certified manufacturer. HT/Armaflex and Armaflex Duosolar materials shall be installed as to the manufacturer’s recommendations using Armaflex HT625 Adhesive as appropriate. All thermal insulation shall have an ozone depletion potential (ODP) of 0 as required. All thermal insulation shall have a global warming potential (GWP) rating of 0 as required. The thermal insulation must be CE marked in accordance with the relevant European standard. SOLAR SPECIFICATION 03 – Insulation 03 – 01 Selection Shall be:For solar hot water UV resistant HT/Armaflex elastomeric EPDM rubber capable of operating at temperatures up to 150°C. The material shall be CFC and H-CFC free. Or: Armaflex DuoSolar stainless steel corrugated solar pipework pre insulated with UV resistant HT/Armaflex elastomeric EPDM rubber capable of operating at temperatures up to 150°C. The product shall incorporate an integrated sensor cable. The material shall be CFC and H-CFC free. Or: Armaflex DuoSolar 220 stainless steel corrugated solar pipework pre insulated with UV resistant HT/Armaflex elastomeric EPDM rubber capable of operating at temperatures up to 220°C. The product shall incorporate an integrated sensor cable. The material shall be CFC and H-CFC free. 03 – 02 Thermal Insulation Materials Material Temp Range HT/Armaflex -50ºC to +150ºC “K” Value W/mK at mean temp 0.042 @ 40ºC ODP Rating GWP Rating Fire Class 0 0 Class 1 Typical material density kg/m3 65 04 – Protection and Protective Coverings 04 – 01 Internal Coverings Shall be: For HT/Armaflex: No painting or covering shall normally be required when using HT/Armaflex outdoors due to the natural inbuilt resistance against UV degradation. For Armaflex DuoSolar: Armaflex DuoSolar features a tough black textured coating pre-applied. No additional covering or cladding shall be required. All excess adhesive visible on the surface of the completed assembly shall be removed using an appropriate cleaning fluid such as Armaflex Cleaner. SOLAR SPECIFICATION 04 – 02 External Coverings Shall be: For HT/Armaflex: No painting or covering shall normally be required when using HT/Armaflex outdoors due to the natural inbuilt resistance against UV degradation. For Armaflex DuoSolar: Armaflex DuoSolar features a tough black textured coating pre-applied. No additional covering or cladding shall be required. All excess adhesive visible on the surface of the completed assembly shall be removed using an appropriate cleaning fluid such as Armaflex Cleaner. 04 – 03 Vapour Barriers Shall be: For HT/Armaflex: Built into the insulation material. The insulation shall have a moisture resistance factor no less than 3,000. No additional external water vapour barrier shall be necessary. 04 – 04 Insulation of Pipework Supports Shall:In all cases have all pipe clips and hangers attached to the outside of the insulation. Metal saddles to be used to prevent crushing of the insulation. 04 – 05 Insulated Valve and Flange Cover Boxes Shall be manufactured directly from the insulation material itself as according to the manufacturer’s recommendations. The covering of fabricated flange or valve covers shall be as for the insulation on the remainder of the attached service pipes.