PY500/PY500-H/PY500S Intelligence and Ability Number Pressure User’s Manual 1. Summarrization 1. The introduction of function Meter PY500/PY500-H/PY500s intelligence and ability number pressure temperature meter is the new product of the development of my company. It has much advanced technology in the world ,such as the technology in electron,singlechip,computer,erasure,anti-jamming and so on .Accordingly the meter has the strong point of high precision of measure and control,as well as has the well fuction of anti-jamming.The whole machine has 96*96*100(PY500)/48*96*100(PY500-H)/96*48*100(PY500S) Dos Shell.So it is small in bulk,light in height and with much electricity,completed function and reliable task .The use of it is flexible and easy.It can be widely used not only in situation of pressure display and antocontrol in hydraulic pressure,oil,plastics,latex,printing and dyeing,textile industry but also can be compound with resistance strain guage press sensor of other manufactor.If it is used with the PT100- series high temperature melt press sensor or PT200-series mormal temperature press sersor.As high precision pressure of measure and control,it can be set upper limit and lower limit alarm.It has the indicator light on alarm,relay touch output control peripheral equipment,high prelision of tension output module,electric current output module and relay output control modult for user to choose from.The machine adopt the operation of humanistic,so it is easy for user to operate. 2. primary technology guide line and function (1).display (2).display exculpation rate (3).the range of display (4).the precision of metre (5).the display of indicator light (6).output signal statoscopo (7).sampling speed (8).sensor opeiating voltage (9).output control (10).main alarm output (11).assistant output (12).the range of alarm (13).effect fitout instruct double four digit high brightness green and ren radiation numeral pipe 0001 0001-9999Mpa (decimal can be changed) 0.2%FS+-1digit adjust indicator light,OUT output indicator light,AL1,AL2 alarm indicator light 2;3.3mV/V (order for explain) 20 times/second 5V high precision DC the pressure or electric current output with full singal rult upper limit alarm has relay output (220V 1A) upper limit alarm display (out) assistant output can be compound with different function module and set by the meter to meet the difference output need.The content in detail please read One(THREE)the explain of module function.Assistant output can be choosed from.(order for explain) 0001-9999Mpa (decimal can be changed) display 80% of the sensor full rult (the sensor should be empty carried) CAE light (14).the temperature and humidity of work 0-55’C, ≥80%RH (15).power demand 85-265VAC 50Hz-60Hz (16).exterior size 96*96*100mm/48*96*100mm/96*48*100mm (17).placket size 92*92mm/46*92mm/92*46mm (18).itsele height about 400g One(Three).The explain of module function PY500/PY500-H intellgence and ability number pressure temperature meter has two sockets of function module.It can be achieved different function and different type of output by setup different module.There are some modules can be choosed from:reply output module,electric current module (4-20mA/0-10mA),tension output module (0-5V/0-10V) and communication module (RS485). Alarm 1(AL-1):select three output module 1. reply module output When pressure over the set (alarm number+dispersion number),the reply will be close (cut).When pressure hangs down the set (alarm number-persion number),the reply will cut (close).To achieve this function,you should setup alarm module on socket reply output modult and set alarm number and dispersion number on meter.(The operation in detail please read PY500/PY500-H operation process). Reply module often cut or often close can select short circuit on CON1 A com1 B When there is short circuit between AB,it is close output. C When there is shout circuit bertween BC, it is cut output. Refer to set number: 1).when the range is 50.00MP the AL-1number is 35.00MP,AL-1 dispersion is 0.2MP and the pressure over 35.20MP,then the reply will close (cut).The reply will cut (close)if the pressure hangs down 34.80MP. 2).when the range is 15.00MP the AL-1number is 10.00MP,AL-1 dispersion is 0.2MP and the pressure over 10.20MP,then the reply will close (cut).The reply will cut (close)if the pressure hangs down 9.8MP. 3).set temperature alarm output 20.0’c,dispersion 0.2’c 2. electric current module output According to pressure straight line output electric current (4-20mA/0-10mA),when the pressure value is smaller or tants amount to 0,the electric current output is the set og DL.If the pressure more than or be equal to the full rult,the electric current output is the set of DH.The set of DL,DH,please read PY500/PY500-H operation process. When the deviation between the reality electric current output and the number of set ,they are indentical by adjusting the electric potential equipment on the electric current module.(having adjused before leaving the factory) 3. tension module output According to pressure straight line output tension (0-5V,0-10V).The module of tension has 0-5V side and 0-10V side. The principle of it is that when electric current module set 0-20mA output,put a 250Ωor 500Ωresistant on the end of output.When the deviation between reality tension and set number,they can be dentical by adjusting the electric protential equipment on the tension module(having adjusted before leaving the factory). 0- 5V output: choose 0-5V tension module, the selection of AL-1 is “I”, the number of DL is 0mA, the number of DH is 20.00mA. Put a 250Ωresistance on the end of output, changing the electric current signal from 0-20mA to 0-5V. 0- 10V output: choose 0-10V tension module, the selection of AL-1 is “I”, the number of DL is 0mA, the number of DH is 20.00mA. Put a 500Ωresistance on the end of output, changing the electric current signal from 0-20mA to 0-10V. Alarm 2 (AL-2): you can choose four output module. 1. reply module output is same to AL-1. R10 2. electric current module output is same to AL-1. R10=250Ω/500Ω 3. tension module output is same to AL-1. 4.communication module output:pass the data of parameter and hits by meeting 485 withequipment. Alarm 3 (AL-3) is same to amarm 1. Alarm 4 (AL-4) :rely module output *When you haven’t set up the releeant AL-1 or AL-2 to “J” of reply and set the alarm “0000” of relevant AL-1 or AL-2. (four)The set of input signal statoscope PY 500/PY500-H Pressure meter has 2、3.3mV/V two selection of statoscope. It can be achieved by asiding the short circuit of main engine.Order for explain. A The number of AB short circuit statoscope is 2mV/V. B The number of BC short circuit statoscope is 3.3mV/V. C The number is 2mV/V leaving the factory. TWO、 Meter Wiring 1 9 1. sensor signal positive (blue wire) 2 10 3 11 2. sensor opeiate positive (red wire) 4 12 3. sensor signal negative (white wire) 5 13 4. sensor opeiate negative (yellow wire) 6 14 7 15 5. sensor proofread and correct (black wire) 8 16 6. meter land.(shield screen line) 7. AL-2 tension, electric current ,reply output positive, 485 communication output 8. AL-2 tension, electric current ,reply output negative, 485 communication output 9. AL-1 tension, electric current ,reply output positive 10.AL-1 tension electric current, reply output negative 11.12. OUT reply close end 12.13. OUT reply cut end 14. 15. alternating power output end 16. earth THREE、 The explain of front board 1) When the press over the alarm number of upper limit, the OUT alarm light will be bright. When the press over the alarm number of AL-1, the AL-1 alarm light will be bright. When the press over the alarm number of AL-2, the AL-2 alarm light will be light. 2) When you press the CAE key of sersor for cheeking, proofread and correct, the lamp of instruct will be bright. 3) The window of PV displays the reality of work pressure 4) The window of SV displays the reality of set parameter 5) When the sensor is empty, the number of display is not 0. If you press the AC key, the indicator will be 0.(It is effective under the state of set ,when the signal of sensor 0 over the full signal rult +20%、-10%,the key is to no avail) 6) When you press the key of CAE,you can see the numberof sensor full rult about 80%。 7) When you press the key of SET,you can be in set state。The key of SET can be devided into long key(press 3 second)and short key(touch one time) 8) > the key of dislocation 9) ∧the key of increment 10) ∨the key of discrement Four、PY500 intelligence and ability meter operation flow chart (一)PY500/PY500-H intelligence and ability meter main operation flow chart Main display state Meter is 0 AC Modify range ED Proofread and correct signal demarcate Set main number of alarm OUT The first line set of AL-1 alarm The second line set of AL-2 alarm Back to main display state 0 full range demarcates ESCL Select type AL-1(J.I) Memo Set HC Set electric current lower limit dL dispersion Back to main display state Set electric current upper limit dL Select type AL-2(J.I) Set HC dispersion Set electric current lower limit dL Set electric current upper limit dH The number machine Baud rate Agreement Select type AL-3(J.I) ,P. Set dispersion HC Set electric current lower limit dL Set electric current upper limit dH of Select type AL-4(J.I),P. rely output module Set strain wave constant gl Set position of decimal point Display internal code Set sensor temperature Recover setup Temperature 0 point dematcate reset Temperature full The selection of lock Back to AC menu Directions: 1.In this flow chart. If you press set for 3 second at anytime, it can be back to main display state. 2.*1menu when the selection “I” for AL-1 type, it does not exist . *2menu when the selection “I” for AL-1 type it dees not exist 3 The main siaplay state is the PV/SV display state for the meter after electric correct discocation. (TWO)The function operation explain of PY500/PY500-H intelligence and ability meter Main display state In the showing of PV/SV, it can be into OUT set when you Main alarm OUT set Press the key of SET. It can be modified when you press the key of >∧∨.If you press the key of SET again, the number is stored and come for the second and it back to main display state. The first line alarm number of AL-1 set The second line alarm number of AL-2 set Back to main display state When the output type of AL-1 is “I” electric current outputting, there is no this window. When the reply is “J”, there is this window. This window is used to set the first line alarm number of AL-1.It can be modified when you press the key of >∧∨.When the number is “0”of no reply output module, the AL-1 Street of meter cannot alarm. When the output type of AL-2 is “I” electric current outputting, there is no this window. When the reply is “J”, there is this window. This window is used to set the second line alarm number of AL-2.It can be modified when you press the key of >∧∨.When the number is “0”of no reply output module, the AL-2 Street of meter cannot alarm. Main display state Meter is 0 AC Modify range ED In the showing of PV/SV, it can be into AC menu after pressing the key of SET more than 3 second. The meter is “0” and set into the next menu, if you press the key of AC. This window is used to set modify range. Please press the key of >∧ ∨ .When you modify the range, the number is stored and come into the next menu when you press the key of SET after modifying the range. You can also press the key of SET for 3 second and it back to main state. The number can’ be set 0 Proofread and correct signal demarcate 0 full range demarcates ESCL Select AL-1(J.I) type This window is used to proofread and correct signal demarcate. Press the key of CAE (You should connect the sensor and pit empty, if you want to do it.) After demarcating it can come into the next menu. This window is used to the full range demarcate. You should press the key of > after connecting the sensor and keep it empty, pleaseraise pressure if the SV window displays “LOAD”. After being loaded to capacity of sensor, please press the key of >. The demarcate will come into the next menu after finishing the work. This window is used to select of the passage of AL-1. It can be modified. When you choose “J”, the passage of Al-1 is reply output. . Set used toelectric current numberlower limit dL This window is used to set The lower Limit of AC-1 this window is Set dispersion HC Passage electric correct. The front two numbers can be modified By pressing >∧∨ key. set the alarm Dispersion of the AC-1 passage. It can be modified By pressing >∧∨ key. The dispersion number is less than 0100(besides the decimal point) Set electric current upper limit dH This window is used to set the upper Limit of AC-1 passage electric correct. The front two numbers can be modified By pressing >∧∨ key. Set type AL-2 (J.I) Number Set used toelectric current numberlower limit dL Baud rate AC-2 This window is used to set The lower Limit of AC-2 Passage electric correct. The front two numbers can be modified By pressing >∧∨ key this window is Set dispersion HC set the alarm Dispersion of the AC-2 passage. It can be modified By pressing > ∧ ∨ key. The dispersion number is less than 0100(besides the decimal point) 0:1200bps 1:2400bps 2:4800bps 3:9600bps 4:19200bps Set electric current upper limit dH This window is used to set the lower Limit of Passage electric correct. The front two numbers can be modified By pressing >∧∨ key agreement Set strain constant gl wave This window id used to set the inertia constant of strain wave. The range is from 1 to 8.It can be modified by pressing the key of >∧∨.We set the machine before leaving the factory. of This window is used to set the position of decimal point, it can be modified. We set two digits for decimal before leaving the factory. Set position decimal point This window is to use to display internal code. Display internal code The selection of lock This window is to use to select whether to lock the relevance or not. “1” lock, “0” unlock, press the key of > can be modified. Back of AC menu Five .Setup meter PY500 11mm PY500H 100mm mm 8 4 mm 6 9 92×92mm 96mm 11mm 100mm 92×44mm 96mm SIX。Stick up for meter Meters can work in the condition of 0-55℃ and the relative humidity is not more than 80% RH without dirt or poison gas. The meters can be free repaired for 12 months from leaving our company. If there is something wrong with the use of customer or the time is beyond the maintenance, out company will call for some money for providing the service of repair.