Metropolitan Medical Centre Ltd. Mohakhali, Dhaka. Tender Schedule Name & Specification of Equipments Name of Equipments 1. O. T. Table (Motorized) (Cardiac Surgery) Quantity 1 (one) Specification Price ( C&F/CIF) Price (Free delivery basis) Double security: Not only electro-hydraulic adjustment by means of remote control but also manual positioning by alternate system so that if auto device dose not work. High controlling pedal, Trendelenburg movements, back & seat section controlling crank handle, change lever, kidney elevator controlling handle, lateral tilt controlling handle wheel, leg section adjusting & removing gear clamp handle, foot operated immobilising brake, cylinder locking lever, short tip for adult & table attachment. 2. Defibrillators 2 (two) Operation: Mains or Battery, Fail -Safe two hand defibrillators, Signal – audible & visual control, Automatic internal safety discharging, with wide range of joule delivery, automatic battery recharging both synchronised or automatic discharge of Defibrillation. Internal Paddle (Adult, pediatric, neonatal). Page Continue 1 of 10 Name of Equipments Quantity 3. Anaesthesia Machine with build in ETCO2 monitoring 2 (two) 4. O. T. Light 5 + 3 bulbs 5 + 5 bulbs 8 + 5 bulbs (Cardiac Surgery) 1(one) 5. Cardiac Monitors For ICU / CCU both non invasive and Invasive 8 (eight) 6. Syringe Pump 10 (ten) Specification Price ( C&F/CIF) Price (Free delivery basis) Compact, high performance & Complete safe, Mobile & portable from the cart, Complete without cylinder with the following: 2 gas model O2 & N2O; 1 x O2 yoke for cylinder 1 x N2O yoke for cylinder; central pipelines 1 x O2 ; 1 x N2O, O2 pressure reducing regulator - 1, N2O pressure reducing regulator - 1, Pressure tube for O2 - 1, Pressure tube for N2O - 1, Chimney price - 1, Mask Large – 1, Mask Small – 1, Head Strap 1,Corruglaid tube - 2, Reseror bag 5L - 1, Plastic air way (Large, Medium, Small) one each - 3, Soda lime pack 500mg - 1, Wrench – 1 82 cm 8 bulbs + 58cm 5 bulbs = 1,20,000 lux + 1,00,000 lux, Large field size Small field size 5 + 5 = 30cm 25cm Ceiling type, Total light capacity 180000 lux - 220000 lux, Temp 150c (max), Temp Increcase 20C, Focusable at a distance 70 – 140cm Continuous monitoring of Neonatal, Paediactrics & Adult patients complete with followings: Capable of simultaneous display of four wave forms - ECG, Invasive Arterial Blood pressure, Central Venous Pressure, SPO2, with also simultaneous display of ST analysis, Heart Rate, Pluse Rate, Temperature. ECG: Standard leads ( 6), Lead wire (10), Identifier – Lead fail, Lethal Arrythmia, Detector of Pace mater, Respiration: Respiration rate - 0 - 2000 BPM / Invasive Temp: Range 0 - 450C, NIBP (Noninvasive - Invasive BP), or IBP, Display Parameter: Systolic, Distolic, Mean pulse rate, time of last measurement, Mode: Auto & Manual, Range:30 - 300 BPM, Pulse oximetry: Artrial O2 structure, Range:50 100%, Periphal pulse rate (PPR), Range:20 – 250 BPM A full range of user friendly functions plus advanced safety features: Convenient battery indicator, Syringe pump, accommodation 10, 20, 30, 50ml syringes, Compatible with syringes available in Bangladesh, Microcomputer – Controlled flow rate accuracy, Informative alarms & added safety functions, Expanded flow rates, Easy -to-read, large display, Convenient reusable memo pad for noting fluids in use, Volume delivered display / clear volume delivered function, Splash-proof casing (IP x 4), Computer interface and nurse call connectors available, Three-way power supply (AC/DC/Internal battery) Page Continue 2 of 10 Name of Equipments Quantity 7. Diathermy Machine 2 (two) 8. Sternal Saw (Cardiac Surgery) 1 (one) 9. Heart Lung Machine and Heater Cooler Unit (Cardiac Surgery) 1 (one) Specification Price ( C&F/CIF) Price (Free delivery basis) Diathermy, Monopolar & Biopolar both system: Monopolar footswitch (cut+coag), Standard Bipolar Footswitch, Universal Active Adapter, Chuck handle reusable, 1R Cord for patient plate, 1R SS patient plate, Handswitching pencil, Reusable Ball electrode, Reusable Blade electrode, Reusable Fine Needle electrode, Reusable Angle Ball Electrode, Reusable Loop Electrode, Crushing Biopolar forceps, Biopolar active cord. Electric sternal saw as used by Cardiac Surgeons 1. Reciprocating distance ≥3mm 2. Gearless variation control speed, oscillating Frequency: >13000cpm, 3. Noise: <65db; Temp. rise <30 oC. 4. Voltage: AC100~240V / 50~60 Hz. Heart Lung Machine: 1. 5- Pump Console base 5 Head Roller Pump (with 3 single roller pump modules and 1 Twin roller pump module) 2. Twin pump module with selectable ratio of Blood & Cardioplegia from 1:1 to 1:20 3. Console should be compatible to integrate a centrifugal pump module 4. Air- Oxygen Blender with hoses and Flow meter 5. Each pump should have programmable modes of operation as: Arterial, Arterial Pulsatile, Cardioplegia, Slave-1, Slave-2, Sucker, Auxiliary & Free. 6. Each individual roller pump should be capable of running independently on 24volts supply with a transformer in the console. 7. The unit should be supplied with a Battery backup for all the pumps, all safety systems and accessories for a minimum of 90 minutes. 8. Individual pump heads should have Harvey Roller pumps with facility for tubing to be used adjustable from 3/16”, ¼”, 3/8” to ½” inches. 9. The Console should have a compact base mount for the entire pump heads together, with pole and handles and standard safety features as Bubble Page Continue 3 of 10 Name of Equipments Quantity Specification Price ( C&F/CIF) Price (Free delivery basis) sensor, level sensor and pressure sensors. 10. Pulsatile module as a standard in the pump 11. The unit should have following monitors: Pressure Monitor (for 04 pressure displays), Time Monitor (03 resettable timers with 01 real time display), Temperature monitors (04 temperature displays), Cardioplegia Delivery (total volume, actual volume, time and pressure display), Temperature controller for Heater cooler unit. 12. Cable less modular Pump. 13. To work with power supply of 220-240V / 50-60Hz. 14. Arterial Air Sensor device, Arterial flow sensor, Arterial pressure (transducer system), Cardioplegia Pressure Line (transducer system), Arterial temperature probe, reserve level sensor monitor with display for all sensors. 15. Must be FDA approved 10. Small Instrument Package (Cardiac Surgery) Package Heater Cooler Unit: 1. Water Cooling Temperature Range: 3⁰ C -32⁰ C (37.4⁰ F-89.6⁰ F). 2. Water Heating Temperature Range: 25⁰ C- 42⁰ C (77⁰ F- 107.6⁰ F) 3. Control Range: 3⁰ C- 42⁰ C (37.4⁰ F- 107.6⁰ F). 4. Control Accuracy: ± 0.5⁰ C. 5. Reservoir Capacity: Cooling: 8qts (7.6 L) Heating: 6qts (5.7 L) 6. Water Flow Rate: 3.5 gpm (13lpm) with self-sealing connectors 7.Pressure: 12.5 psi (.878 kg/cm2), maximum blanket connection. 8. Must be FDA/CE approved As per list. 11. Emergency Drug Cart made by Stainless Steel 2 (two) Standard size with drawers and heavy duty wheels. Page Continue 4 of 10 Name of Equipments 12. Multi Slice CT Scan Machine Quantity 1 (One) Specification Price ( C&F/CIF) Price (Free delivery basis) The 64/128 slice Spiral CT Scanner designed for the whole body and cardiac scanning. The system consisting of Gantry, Couch, Operating console with preview station & Cardiac Post-processing workstation, filming with DICOM compatible Dry Laser Imager, Color Laser Printer An online UPS for the complete system for backup power in case of mains failure and fluctuation. Image Storage in system HD and image transfer through CD/DVD Writer The system must have DICOM (latest version) on line data/image transfer capability Rotating anode type X-ray tube and Ceramic detector Dual Head Automatic Injector synchronized with the system. Voice link: Vocal instruction to the patient System is brand new and from current production line System must be upgradeable to 128 slice higher CT System. True 3D Cone Beam Correction Technique should be available in all modes of acquisition such as spiral, axial, in various studies for whole body and cardiac (CT Angiogram and DSA for Cerebral Angiogram). The ECG gated acquisition should have high accuracy of real time monitoring and adapting continuously heart rate changes into the ECG trigger delay during each scan. Pediatric and infant base protocols shall be available based on the infant weight. CT Fluoroscopy and Continuous CT applications utilizing cart mounted monitor with real time guidance for interventional procedures (upto 8fps) available as standard. It should be possible to perform gantry room scans using a foot pedal. Appropriate Voltage stabilizer if required and dehumidifier to be supplied. Table is from same country and manufacturer Remote control of the couch from console Load Capacity : 200 Kg Scan able range : 160cm or more Page Continue 5 of 10 Name of Equipments Quantity Specification Price ( C&F/CIF) Price (Free delivery basis) Cerebral Perfusion Study with Stroke Protocols CT Angio with quantitative vessel analysis Brain & Body Perfusion Lung Nodule Assessment Complete Cardiac Package with ECG gated studies (retrospective tagging) Calcium scoring Cardiac function analysis Quantification of stenosis and plaque analysis Automatic Vessel measurement Coronary Angio Coronary Tree Extraction One Touch Volume Rendering of the whole heart Calcium & Coronary Angio Reporting ECG gated dose modulation Warranty 2-5 years. Post Warranty maintenance contract to be negotiated at the time of work order. Rapid running spare parts price to be quoted like X-ray tube, Advance post processing workstation, Acquisition & processing workstation, etc at the time of work order. Must be FDA/CE approved 13. Portable Suction Machine 3 (three) Use for Cardiac OT patients. 14. Ventilator Machine 2 (two) Control, assist control SIMV and CPAP volume control ventilation in A/C or SIMV modes, pressure support ventilation in spont or SIMV, Digital display, pressure, Breathring, volume & alarm, Air/O2 mixer humidifier, Built in Battery for 2 - 7 hours, Page Continue 6 of 10 Name of Equipments 15. Laparoscopy Machine Quantity 1 (one) Specification Price ( C&F/CIF) Price (Free delivery basis) Instruments & Equipments for Laparoscopic Cholecystectomy consisting of: 1. Straight Forward Telescope 0°, enlarged view, diameter 10mm, length 31cm, autoclavable. Fiber optic light transmission should be incorporated.- 1pc 2. Trocar with pyramidal tip, size 11mm, cannula with multifunctional valve and insufflation stop-cock, length 10.5 12.0 cm. 2 pc 3. Trocar with pyramidal tip, size 6mm, cannula with multifunctional valve and insufflation stop-cock, length 10.5 12.0cm. -2 pc 4. Reducer 11/ 5 mm for use with 11mm trocar cannula. - 1pc 5. Reduction sleeve, reusable, instrument diameter 5mm, trocar cannula O.D. 11mm. -1 pc 6. Dissecting and Grasping Forceps (Dolphin type), insulated, size 5mm, jaw 13mm, length 35 - 43cm, double action jaws, plastic handle without ratchet. - 1pc 7. Dissecting and Grasping Forceps (Marryland type), insulated, size 5mm, jaw 16mm, length 35 - 43cm, double action jaws, plastic handle without ratchet. -1 pc 8. Dissecting and Grasping Forceps, robust, insulated, size 5mm, jaw 13mm, length 35 - 43cm, double action jaws, plastic handle with ratchet. -1pc 9. Dissecting and Grasping Forceps, 2x4 teeth, insulated, size 5mm, jaw 14mm, length 35 - 43cm, double action jaws, plastic handle with ratchet. -1 pc 10. Scissors, metzenbaum, curved, length of blade 12mm, insulated, size 5mm, length 35 - 43cm, double action jaws, plastic handle without ratchet. -1 pc 11. KOH Macro Needle Holder, ergonomic handle with ratchet, left curved jaws, with tungsten carbide inserts, size 5 mm, length 33 cm for use with suture material 0/0-7/0. -1 pc Page Continue 7 of 10 Name of Equipments Quantity Specification Price ( C&F/CIF) Price (Free delivery basis) 12. Dissecting Cannula, L-shaped, size 5mm, length 35 - 43cm, with trumpet valve. -1 pc 13. Suction Coagulator, size 5mm, length 35 - 43cm, with trumpet valve. -1 pc 14. Applier for ligating clips (medium large), size 10mm, length 36cm, dismantling, rotating, with ratchet to lock the jaw part holding the clip. 1 pc 15. Titanium Ligating Clips (medium large), sterile, box of 120 clips. -1 box 16. Monopolar High Frequency Cord with 4 mm plug for HF-unit, length approx. 300cm. - 1 pc 17. Tacker 5mm endoscopic mesh fixation device, consisting of (a) one multiple use tacker handle, (b) 1pc tacker cartridge of 20 helical fastener. -1 pc 18. Electronic CO2-Endoflator, with pin-index connection Following features should be available in the system: Easy to use, fully automatic operations. High safety for patient. Optical and acoustical warning signals in case of overpressure. Electronically controlled gas refill. Modular design for rapid service. Technical Specifications: Insufflation pressure: 0 - 30 mmHg Gas flow: 0 - 20 l/min Control system: Electronic Displays: Digital and analogue display of patient pressure and gas flow Power supply: 220VAC, 50Hz. - 1 set 19. Disinfection System for cleaning and disinfection solutions, Plastic basin with lid and filter, approx. 705 x 220 x 95 mm. -2 pc 20. Mobile video cart/trolley with power socket, rides on 4 wheel, 4 shelves (Local Made). -1 pc 21. Oil for Instruments, approx. 50 ml bottle. -6 pc 22. Cleaning Brush, diameter 2.5 mm, length 35 cm. - 6 pc 23. Must be FDA/CE approved Page Continue 8 of 10 Name of Equipments Quantity Specification 16. Air Compressor 2 (two) 17. Portable Ventilator 2 (two) 18. Patient Monitor 4 (four) Touch Screen, ECG, SPO2, Temp., NIBP with monitor stand. 19. Patient Bed with bed side locker 20 (twenty) Suitable for general & surgery patients. 20. Electric ICU Bed 10 (ten) Electric bed with mattress. 5 Functions, Suitable for ICU Price ( C&F/CIF) Price (Free delivery basis) Screw Type Air Compressor 800Ltr/min Motor Load: 5.50 KW, Line pressure 4 bar standby, machine pressure : 7.50 bar, 3 phase, Air Tank Capacity: 400 Ltr, Air Filter, Water Separator-Zero loss, V-Belt, Dryer, Protection Filter, Air cool. patients. 21. Scrub Station 2 (two) 22. Automatic Washing Plant 1 (one) Scrub Sink - 2 station and 3 station. 1. All automatic deluxe scrub station. 2. Sterilized water (99.6%) supply - two U.V. water sterilizing lamps. 3. Hot water supply for four seasons. 4. Thorough filtering - prefilter and main filter. 5. Easy operation by knee - water and soap. 6. Water pressure control device. 7. Safe-dual temperature sensors for safety. 8. Rust-proof materials-all stainless steel (SUS304) and copper tubes. 9. Mirror system 10. Charming design. Machine Capacity: 25 KG, Heating element: Electric, Tumble Dryer, Flat Work Ironer- Capacity 30kg/hr, frontal linen entry & exit. Page Continue 9 of 10 Terms & Conditions in schedule of equipments: 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 15) 16) The management can accept or reject any tender without showing any reasons what so ever. Only manufacturers or their authorized agents can bid for supply. The bidder should have VAT / TIN number and trade licence and a registered office. The supplier should have trained engineers for after sale service / installation. The bidder should provide a list of name of engineers and their qualification and submit a copy of theirs authorized agent from their manufacturer. The equipment must be made uptime within 3-5 days after downtime information. The bidder should agree to enter into maintenance contract and after sales service after warranty period. The bidder should give a guarantee of supply of spare parts for next 10 years. Quotation for yearly maintenance contract should be submitted along with the tender. Preference will be given to bidders who can provide 2 years full warranty and subsequent period of one year with free labour charge but spare parts costs will be born by Metropolitan Medical Centre Ltd. The bidder should supply any consumable / regents and the accessories required for commissioning, installing and demonstrating the equipment in working condition for the user at their own cost in Metropolitan Medical Centre Ltd. The bidder should provide a catalogue from their manufacturers and a certificate from manufacturer to the effect that the equipments are brand new and of latest model. No part supply would be accepted. The bidder should quote the price in both C&F/CIF and free delivery in local currency. Appropriate voltage stabilizer / Online UPS if required should be supplied with equipments. The equipments should be Compatible with local electric supply. Rechargeable batteries should be provided where required. Required VAT/IT/Security if any would be deducted from total bill of supplier during payment. The price validity of the items should be valid for next 6 months. Earnest Money @ 3% of the bid value should be provided at the time of dropping tender in the form of Pay Order/Bank Draft. Performance guarantee of another 2.5% will have to be provided by those whose tender will be accepted for purchase. It will be adjusted with 3% earnest money. The performance guarantee may be in the form of pay order/draft which will be released after successful installation and handing over the equipments in working condition. Delivery and commissioning schedule should be strictly maintained. Otherwise a penalty of Tk. 5000/- (five thousand) per day for equipment costing upto Tk. 20 lacs, Tk. 10000/- (ten thousand) per day for equipment costing between 20-50 lacs and Tk. 15000/(fifteen thousand) per day for equipment costing more than 50 lacs will be imposed upon the supplier. Page Continue 10 of 10