Ventilators - MMCL ........ Metropolitan Medical Centre

advertisement
Metropolitan Medical Centre Ltd.
Mohakhali, Dhaka.
Tender Schedule
Name & Specification of Equipments
Name of Equipments
1. O. T. Table (Motorized)
(Cardiac Surgery)
Quantity
1 (one)
Specification
Price
( C&F/CIF)
Price (Free delivery
basis)
Double security: Not only electro-hydraulic adjustment by
means of remote control but also manual positioning by
alternate system so that if auto device dose not work.
High controlling pedal, Trendelenburg movements, back & seat
section controlling crank handle, change lever, kidney elevator
controlling handle, lateral tilt controlling handle wheel, leg
section adjusting & removing gear clamp handle, foot operated
immobilising brake, cylinder locking lever, short tip for adult &
table attachment.
2. Defibrillators
2 (two)
Operation: Mains or Battery, Fail -Safe two hand defibrillators,
Signal – audible & visual control, Automatic internal safety
discharging, with wide range of joule delivery, automatic battery
recharging both synchronised or automatic discharge of
Defibrillation. Internal Paddle (Adult, pediatric, neonatal).
Page Continue 1 of 10
Name of Equipments
Quantity
3. Anaesthesia Machine with build
in ETCO2 monitoring
2 (two)
4. O. T. Light
5 + 3 bulbs
5 + 5 bulbs
8 + 5 bulbs
(Cardiac Surgery)
1(one)
5. Cardiac Monitors
For ICU / CCU both non invasive
and Invasive
8 (eight)
6. Syringe Pump
10 (ten)
Specification
Price
( C&F/CIF)
Price (Free delivery
basis)
Compact, high performance & Complete safe, Mobile &
portable from the cart, Complete without cylinder with the
following: 2 gas model O2 & N2O; 1 x O2 yoke for cylinder 1 x
N2O yoke for cylinder; central pipelines 1 x O2 ; 1 x N2O, O2
pressure reducing regulator - 1, N2O pressure reducing regulator
- 1, Pressure tube for O2 - 1, Pressure tube for N2O - 1, Chimney
price - 1, Mask Large – 1, Mask Small – 1, Head Strap 1,Corruglaid tube - 2, Reseror bag 5L - 1, Plastic air way (Large,
Medium, Small) one each - 3, Soda lime pack 500mg - 1,
Wrench – 1
82 cm 8 bulbs + 58cm 5 bulbs = 1,20,000 lux + 1,00,000 lux,
Large field size
Small field size
5 + 5 = 30cm
25cm
Ceiling type, Total light capacity 180000 lux - 220000 lux, Temp
150c (max), Temp Increcase 20C, Focusable at a distance 70 –
140cm
Continuous monitoring of Neonatal, Paediactrics &
Adult patients complete with followings: Capable of
simultaneous display of four wave forms - ECG, Invasive Arterial
Blood pressure, Central Venous Pressure, SPO2, with also
simultaneous display of ST analysis, Heart Rate, Pluse Rate,
Temperature.
ECG: Standard leads ( 6), Lead wire (10),
Identifier – Lead fail, Lethal Arrythmia, Detector of Pace mater,
Respiration: Respiration rate - 0 - 2000 BPM / Invasive
Temp: Range 0 - 450C, NIBP (Noninvasive - Invasive
BP), or IBP, Display Parameter: Systolic, Distolic, Mean pulse
rate, time of last measurement, Mode: Auto & Manual, Range:30
- 300 BPM, Pulse oximetry: Artrial O2 structure, Range:50 100%, Periphal pulse rate (PPR), Range:20 – 250 BPM
A full range of user friendly functions plus advanced safety
features:
Convenient battery indicator, Syringe pump, accommodation 10,
20, 30, 50ml syringes, Compatible with syringes available in
Bangladesh, Microcomputer – Controlled flow rate accuracy,
Informative alarms & added safety functions, Expanded flow
rates, Easy -to-read, large display,
Convenient reusable memo pad for noting fluids in use, Volume
delivered display / clear volume delivered function, Splash-proof
casing (IP x 4), Computer interface and nurse call connectors
available, Three-way power supply (AC/DC/Internal battery)
Page Continue 2 of 10
Name of Equipments
Quantity
7. Diathermy Machine
2 (two)
8. Sternal Saw
(Cardiac Surgery)
1 (one)
9. Heart Lung Machine and
Heater Cooler Unit
(Cardiac Surgery)
1 (one)
Specification
Price
( C&F/CIF)
Price (Free delivery
basis)
Diathermy, Monopolar & Biopolar both system: Monopolar
footswitch (cut+coag), Standard Bipolar Footswitch, Universal
Active Adapter, Chuck handle reusable, 1R Cord for patient
plate, 1R SS patient plate, Handswitching pencil, Reusable Ball
electrode, Reusable Blade electrode, Reusable Fine Needle
electrode, Reusable Angle Ball Electrode, Reusable Loop
Electrode, Crushing Biopolar forceps, Biopolar active cord.
Electric sternal saw as used by Cardiac Surgeons
1. Reciprocating distance ≥3mm
2. Gearless variation control speed, oscillating Frequency:
>13000cpm,
3. Noise: <65db; Temp. rise <30 oC.
4. Voltage: AC100~240V / 50~60 Hz.
Heart Lung Machine:
1. 5- Pump Console base 5 Head Roller Pump (with 3 single
roller pump modules and 1 Twin roller pump module)
2. Twin pump module with selectable ratio of Blood &
Cardioplegia from 1:1 to 1:20
3. Console should be compatible to integrate a centrifugal
pump module
4. Air- Oxygen Blender with hoses and Flow meter
5. Each pump should have programmable modes of
operation as:
Arterial, Arterial Pulsatile, Cardioplegia, Slave-1,
Slave-2, Sucker, Auxiliary & Free.
6. Each individual roller pump should be capable
of running independently on 24volts supply with
a transformer in the console.
7. The unit should be supplied with a Battery backup for all the
pumps, all safety systems and accessories for a minimum of 90
minutes.
8. Individual pump heads should have Harvey Roller pumps with
facility for tubing to be used adjustable from 3/16”, ¼”, 3/8” to ½”
inches.
9. The Console should have a compact base mount
for the entire pump heads together, with pole and
handles and standard safety features as Bubble
Page Continue 3 of 10
Name of Equipments
Quantity
Specification
Price
( C&F/CIF)
Price (Free delivery
basis)
sensor, level sensor and pressure sensors.
10. Pulsatile module as a standard in the pump
11. The unit should have following monitors: Pressure Monitor
(for 04 pressure displays), Time Monitor (03 resettable
timers with 01 real time display), Temperature monitors (04
temperature displays), Cardioplegia Delivery (total volume,
actual volume, time and pressure display), Temperature
controller for Heater cooler unit.
12. Cable less modular Pump.
13. To work with power supply of 220-240V / 50-60Hz.
14. Arterial Air Sensor device, Arterial flow sensor, Arterial pressure
(transducer system), Cardioplegia Pressure Line (transducer
system), Arterial temperature probe, reserve level sensor monitor with display for all sensors.
15. Must be FDA approved
10. Small Instrument Package
(Cardiac Surgery)
Package
Heater Cooler Unit:
1. Water Cooling Temperature Range: 3⁰ C -32⁰ C (37.4⁰ F-89.6⁰
F).
2. Water Heating Temperature Range: 25⁰ C- 42⁰ C (77⁰ F- 107.6⁰
F)
3. Control Range: 3⁰ C- 42⁰ C (37.4⁰ F- 107.6⁰ F).
4. Control Accuracy: ± 0.5⁰ C.
5. Reservoir Capacity: Cooling: 8qts (7.6 L) Heating: 6qts (5.7 L)
6. Water Flow Rate: 3.5 gpm (13lpm) with self-sealing connectors
7.Pressure: 12.5 psi (.878 kg/cm2), maximum blanket connection.
8. Must be FDA/CE approved
As per list.
11. Emergency Drug Cart made
by Stainless Steel
2 (two)
Standard size with drawers and heavy duty wheels.
Page Continue 4 of 10
Name of Equipments
12. Multi Slice CT Scan Machine
Quantity
1 (One)
Specification




















Price
( C&F/CIF)
Price (Free delivery
basis)
The 64/128 slice Spiral CT Scanner designed for the whole
body and cardiac scanning.
The system consisting of Gantry, Couch, Operating console
with preview station & Cardiac Post-processing workstation,
filming with DICOM compatible Dry Laser Imager, Color
Laser Printer
An online UPS for the complete system for backup power in
case of mains failure and fluctuation.
Image Storage in system HD and image transfer through
CD/DVD Writer
The system must have DICOM (latest version) on line
data/image transfer capability
Rotating anode type X-ray tube and Ceramic detector
Dual Head Automatic Injector synchronized with the
system.
Voice link: Vocal instruction to the patient
System is brand new and from current production line
System must be upgradeable to 128 slice higher CT
System.
True 3D Cone Beam Correction Technique should be
available in all modes of acquisition such as spiral, axial, in
various studies for whole body and cardiac (CT Angiogram
and DSA for Cerebral Angiogram).
The ECG gated acquisition should have high accuracy of
real time monitoring and adapting continuously heart rate
changes into the ECG trigger delay during each scan.
Pediatric and infant base protocols shall be available based
on the infant weight.
CT Fluoroscopy and Continuous CT applications utilizing
cart mounted monitor with real time guidance for
interventional procedures (upto 8fps) available as standard.
It should be possible to perform gantry room scans using a
foot pedal.
Appropriate Voltage stabilizer if required and dehumidifier
to be supplied.
Table is from same country and manufacturer
Remote control of the couch from console
Load Capacity : 200 Kg
Scan able range : 160cm or more
Page Continue 5 of 10
Name of Equipments
Quantity
Specification
Price
( C&F/CIF)
Price (Free delivery
basis)





Cerebral Perfusion Study with Stroke Protocols
CT Angio with quantitative vessel analysis
Brain & Body Perfusion
Lung Nodule Assessment
Complete Cardiac Package with ECG gated studies
(retrospective tagging)

Calcium scoring

Cardiac function analysis

Quantification of stenosis and plaque analysis

Automatic Vessel measurement

Coronary Angio

Coronary Tree Extraction

One Touch Volume Rendering of the whole heart

Calcium & Coronary Angio Reporting

ECG gated dose modulation

Warranty 2-5 years.

Post Warranty maintenance contract to be negotiated at the
time of work order.

Rapid running spare parts price to be quoted like X-ray
tube, Advance post processing workstation, Acquisition
& processing workstation, etc at the time of work order.
Must be FDA/CE approved
13. Portable Suction Machine
3 (three)
Use for Cardiac OT patients.
14. Ventilator Machine
2 (two)
Control, assist control SIMV and CPAP volume control
ventilation in A/C or SIMV modes, pressure support ventilation in
spont or SIMV, Digital display, pressure, Breathring, volume &
alarm, Air/O2 mixer humidifier, Built in Battery for 2 - 7 hours,
Page Continue 6 of 10
Name of Equipments
15. Laparoscopy Machine
Quantity
1 (one)
Specification
Price
( C&F/CIF)
Price (Free delivery
basis)
Instruments & Equipments for Laparoscopic
Cholecystectomy
consisting of:
1. Straight Forward Telescope 0°, enlarged view, diameter
10mm, length 31cm, autoclavable. Fiber optic light transmission
should be incorporated.- 1pc
2. Trocar with pyramidal tip, size 11mm, cannula with
multifunctional valve and insufflation stop-cock, length 10.5 12.0 cm. 2 pc
3. Trocar with pyramidal tip, size 6mm, cannula with
multifunctional valve and insufflation stop-cock, length 10.5 12.0cm. -2 pc
4. Reducer 11/ 5 mm for use with 11mm trocar cannula. - 1pc
5. Reduction sleeve, reusable, instrument diameter 5mm, trocar
cannula O.D. 11mm. -1 pc
6. Dissecting and Grasping Forceps (Dolphin type), insulated,
size 5mm, jaw 13mm, length 35 - 43cm, double action jaws,
plastic handle without ratchet. - 1pc
7. Dissecting and Grasping Forceps (Marryland type), insulated,
size 5mm, jaw 16mm, length 35 - 43cm, double action jaws,
plastic handle without ratchet. -1 pc
8. Dissecting and Grasping Forceps, robust, insulated, size
5mm, jaw 13mm, length 35 - 43cm, double action jaws, plastic
handle with ratchet. -1pc
9. Dissecting and Grasping Forceps, 2x4 teeth, insulated, size
5mm, jaw 14mm, length 35 - 43cm, double action jaws, plastic
handle with ratchet. -1 pc
10. Scissors, metzenbaum, curved, length of blade 12mm,
insulated, size 5mm, length 35 - 43cm, double action jaws,
plastic handle without ratchet. -1 pc
11. KOH Macro Needle Holder, ergonomic handle with ratchet,
left curved jaws, with tungsten carbide inserts, size 5 mm, length
33 cm for use with suture material 0/0-7/0. -1 pc
Page Continue 7 of 10
Name of Equipments
Quantity
Specification
Price
( C&F/CIF)
Price (Free delivery
basis)
12. Dissecting Cannula, L-shaped, size 5mm, length 35 - 43cm,
with trumpet valve. -1 pc
13. Suction Coagulator, size 5mm, length 35 - 43cm, with
trumpet valve. -1 pc
14. Applier for ligating clips (medium large), size 10mm, length
36cm, dismantling, rotating, with ratchet to lock the jaw part
holding the clip. 1 pc
15. Titanium Ligating Clips (medium large), sterile, box of 120
clips. -1 box
16. Monopolar High Frequency Cord with 4 mm plug for HF-unit,
length approx. 300cm. - 1 pc
17. Tacker 5mm endoscopic mesh fixation device, consisting of
(a) one multiple use tacker handle, (b) 1pc tacker cartridge of 20
helical fastener. -1 pc
18. Electronic CO2-Endoflator, with pin-index connection
Following features should be available in the system:
 Easy to use, fully automatic operations.
 High safety for patient.
 Optical and acoustical warning signals in case of
overpressure.
 Electronically controlled gas refill.
 Modular design for rapid service.
Technical Specifications:
Insufflation pressure: 0 - 30 mmHg
Gas flow: 0 - 20 l/min
Control system: Electronic
Displays: Digital and analogue display of patient pressure and
gas flow
Power supply: 220VAC, 50Hz. - 1 set
19. Disinfection System for cleaning and disinfection solutions,
Plastic basin with lid and filter, approx. 705 x 220 x 95 mm. -2 pc
20. Mobile video cart/trolley with power socket, rides on 4 wheel,
4 shelves (Local Made). -1 pc
21. Oil for Instruments, approx. 50 ml bottle. -6 pc
22. Cleaning Brush, diameter 2.5 mm, length 35 cm. - 6 pc
23. Must be FDA/CE approved
Page Continue 8 of 10
Name of Equipments
Quantity
Specification
16. Air Compressor
2 (two)
17. Portable Ventilator
2 (two)
18. Patient Monitor
4 (four)
Touch Screen, ECG, SPO2, Temp., NIBP with monitor stand.
19. Patient Bed with bed side locker
20
(twenty)
Suitable for general & surgery patients.
20. Electric ICU Bed
10 (ten)
Electric bed with mattress. 5 Functions, Suitable for ICU
Price
( C&F/CIF)
Price (Free delivery
basis)
Screw Type Air Compressor 800Ltr/min
Motor Load: 5.50 KW, Line pressure 4 bar standby, machine
pressure : 7.50 bar, 3 phase, Air Tank Capacity: 400 Ltr, Air
Filter, Water Separator-Zero loss, V-Belt, Dryer, Protection
Filter, Air cool.
patients.
21. Scrub Station
2 (two)
22. Automatic Washing Plant
1 (one)
Scrub Sink - 2 station and 3 station.
1. All automatic deluxe scrub station.
2. Sterilized water (99.6%) supply - two U.V. water sterilizing
lamps.
3. Hot water supply for four seasons.
4. Thorough filtering - prefilter and main filter.
5. Easy operation by knee - water and soap.
6. Water pressure control device.
7. Safe-dual temperature sensors for safety.
8. Rust-proof materials-all stainless steel (SUS304) and copper
tubes.
9. Mirror system
10. Charming design.
Machine Capacity: 25 KG, Heating element: Electric, Tumble
Dryer, Flat Work Ironer- Capacity 30kg/hr, frontal linen entry &
exit.
Page Continue 9 of 10
Terms & Conditions in schedule of equipments:
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
16)
The management can accept or reject any tender without showing any reasons what so ever.
Only manufacturers or their authorized agents can bid for supply.
The bidder should have VAT / TIN number and trade licence and a registered office.
The supplier should have trained engineers for after sale service / installation.
The bidder should provide a list of name of engineers and their qualification and submit a copy of theirs authorized agent from their
manufacturer. The equipment must be made uptime within 3-5 days after downtime information.
The bidder should agree to enter into maintenance contract and after sales service after warranty period. The bidder should give a
guarantee of supply of spare parts for next 10 years. Quotation for yearly maintenance contract should be submitted along with the
tender.
Preference will be given to bidders who can provide 2 years full warranty and subsequent period of one year with free labour charge but
spare parts costs will be born by Metropolitan Medical Centre Ltd.
The bidder should supply any consumable / regents and the accessories required for commissioning, installing and demonstrating the
equipment in working condition for the user at their own cost in Metropolitan Medical Centre Ltd.
The bidder should provide a catalogue from their manufacturers and a certificate from manufacturer to the effect that the equipments
are brand new and of latest model.
No part supply would be accepted.
The bidder should quote the price in both C&F/CIF and free delivery in local currency.
Appropriate voltage stabilizer / Online UPS if required should be supplied with equipments. The equipments should be Compatible with
local electric supply. Rechargeable batteries should be provided where required.
Required VAT/IT/Security if any would be deducted from total bill of supplier during payment.
The price validity of the items should be valid for next 6 months.
Earnest Money @ 3% of the bid value should be provided at the time of dropping tender in the form of Pay Order/Bank Draft.
Performance guarantee of another 2.5% will have to be provided by those whose tender will be accepted for purchase. It will be
adjusted with 3% earnest money. The performance guarantee may be in the form of pay order/draft which will be released after
successful installation and handing over the equipments in working condition.
Delivery and commissioning schedule should be strictly maintained. Otherwise a penalty of Tk. 5000/- (five thousand) per day for
equipment costing upto Tk. 20 lacs, Tk. 10000/- (ten thousand) per day for equipment costing between 20-50 lacs and Tk. 15000/(fifteen thousand) per day for equipment costing more than 50 lacs will be imposed upon the supplier.
Page Continue 10 of 10
Download