Wood Ultimate Casement Storm Plus IZ3 Window

advertisement
SECTION 08 52 00
WOOD ULTIMATE CASEMENT STORM PLUS IZ3 WINDOW
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Wood Ultimate Casement/Awning window: Operators, Stationary and Picture units complete with hardware,
glazing, weather strip, insect screens, removable wood grilles, grilles-between-the-glass, simulated divided
lite, jamb C extension, and standard or specified anchors, trim, and attachments.
1.2 RELATED SECTIONS
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
Section 01 33 23—Submittal Procedures: Shop Drawings, Product Data and Samples
Section 01 62 00—Product Options
Section 01 65 00—Product Delivery
Section 01 66 00—Storage and Handling Requirements
Section 01 71 00—Examination and Preparation
Section 01 74 00—Execution
Section 01 76 00—Cleaning and Waste Management
Section 01 76 00—Protecting Installed Construction
Section 06 22 00—Millwork: Wood trim other than furnished by window manufacturer
Section 07 92 00—Joint Sealants: Sill sealant and perimeter caulking
Section 09 90 00—Paint or stain other than factory applied finish
1.3 REFERENCES
A. American Society for Testing Materials
1. E 283: Standard Test Method for Rate of Air Leakage through Exterior Windows, Curtain Walls, and
Doors.
2. E 330: Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors
by Uniform Static Air Pressure Difference.
3. E 547: Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by
Cyclic Static Air Pressure Differential.
4. E 2190: Specification for Sealed Insulated Glass Units
5. C 1036: Standard Specification for Flat Glass.
6. E 1996: Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Storm
Shutters Impacted by Windborne Debris in Hurricanes.
7. E 1886: Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm
Shutters Impacted by Missile (s) and Exposed to Cyclic Pressure Differentials.
B. WDMA I.S.4: Industry Standard for Water Repellent Preservative Treatment for Millwork.
C. American Architectural Manufactures Association / Window and Door Manufactures Association (AAMA /
WDMA): ANSI / AAMA / NWWDA 101 / I.S.2-97 Voluntary Specifications for Aluminum, Vinyl (PVC) and
Wood Windows and Glass Doors. And 101 / I.S.2 / NAFS-02 Voluntary Performance Specification for
Windows, Skylights, Glass Doors and AAMA / WDMA / CSA 101/I.S.2/A440-08 Standard/Specification for
Windows, Doors, and Skylights.
D. Window and Door Manufacturers Association (WDMA): 101 / I.S.2 WDMA Hallmark Certification Program.
E. Sealed Insulating Glass Manufactures Association / Insulating Glass Certification Council (SIGMA / IGCC).
F. American Architectural Manufacturers Association (AAMA): 2605: Voluntary Specification for High
Performance Organic Coatings on Architectural Extrusions and Panels.
G. National Fenestration Rating Council (NFRC): 101: Procedure for Determining Fenestration Product
Thermal Properties.
1.4 System Description
A. Design and Performance Requirements:
1. Window units shall be designed to comply with ASTM E 1996 Wind Zone 3 Missile Level D Rating +65/65 psf.
2. Air leakage shall not exceed the following when tested at 6.24 psf according to ASTM E 283: 0.30 cfm
per square foot of frame.
3. No water penetration when tested at the following pressure according to ASTM E 547: 6.0 psf.
4. Assembly shall withstand a positive or negative uniform static air pressure difference of 60 psf without
damage when tested according to ASTM E 330.
Doc. 71374 Rev. 5/27/2011
08 52 00 - 1 Wood Ultimate Casement Storm Plus IZ3 Window - 2009
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed on: 2/10/2016 12:06 AM
SECTION 08 52 00
WOOD ULTIMATE CASEMENT STORM PLUS IZ3 WINDOW
5.
Impact and Cycling per ASTM E 1996 and E 1886 with passing results for Missile Level D and Pressure
Cycling of +65/-65 psf.
1.5 SUBMITTALS
A.
B.
C.
D.
E.
1.6
Shop Drawings: Submit shop drawings under provisions of Section 01 33 23.
Product Data: Submit catalog data under provisions of Section 01 33 23.
Samples: Submit corner section under provisions of Section 01 33 23.
Include glazing system, quality of construction, and specified Finish.
Quality Control Submittals: Certificates: Submit manufacture’s certifications indicating compliance with
specified performance and design requirements under provisions of Section 01 33 23.
QUALITY ASSURANCE
A. Regulatory Requirements: Emergency Egress or Rescue: Comply with requirements for sleeping units of
[IBC International Building Code] [BOCA Basic Building Code] [Southern Building Code] [Uniform Building
Code].
1.7 DELIVERY
A. Comply with provisions of Section 01 65 00.
B. Deliver in original packaging and protect from weather.
1.8 STORAGE AND HANDLING
A. Prime or seal wood surfaces, including surface to be concealed by wall construction, if more than thirty (30)
days will expire between delivery and installation.
B. Store window units in an upright position in a clean and dry storage area above ground and protect from
weather under provisions of Section 01 66 00.
1.9 WARRANTY
A. The following limited warranty is subject to conditions and exclusions. There are certain conditions or
applications over which Marvin has no control. Defects or problems as a result of such conditions or
applications are not the responsibility of Marvin. For a more complete description of the Marvin limited
warranty, refer to the Marvin Windows and Doors Ten-Year Limited Warranty.
B. Windows shall be warranted to be free from defects in manufacturing, materials, and workmanship for a
period of ten (10) years from the purchase date.
C. Insulating glass shall be warranted against visible obstruction through the glass caused by a failure of the
insulating glass air seal for a period of twenty (20) years from the date of original purchase.
PART 2 PRODUCTS
2.1
MANUFACTURED UNITS
A. Description: Factory assembled Wood Ultimate Casement operating exterior swing window, as
manufactured by Marvin Windows and Doors, Warroad, Minnesota.
2.2
FRAME DESCRIPTION
A. Interior: Clear Pine or finger jointed core with clear Pine veneer, or Douglas Fir; optional species; clear
Mahogany or finger jointed core with clear Mahogany veneer; clear Vertical Grain Douglas Fir or finger
jointed core with clear Vertical Grain Douglas Fir veneer.
1. Kiln dried to moisture content no greater than twelve (12) percent at the time of fabrication.
2. Water repellent preservative treated in accordance with WDMA I.S.4.
B. Frame Thickness: 1 3/16” (30mm).
C. Frame depth: Overall 5 21/32 inch (144mm) for full frame applications, and 4 9/16 inch (116mm) jamb depth
from the back of exterior casing to the interior face of the frame for new construction.
2.3
SASH DESCRIPTION
Doc. 71374 Rev. 5/27/2011
08 52 00 - 2 Wood Ultimate Casement Storm Plus IZ3 Window - 2009
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed on: 2/10/2016 12:06 AM
SECTION 08 52 00
WOOD ULTIMATE CASEMENT STORM PLUS IZ3 WINDOW
A. Clear Pine standard or Douglas Fir; optional species Mahogany or Vertical Grain Douglas Fir.
1. Kiln dried to moisture content no greater than twelve (12) percent at the time of fabrication.
2. Water repellent preservative treated in accordance with WDMA I.S.4.
B. Sash thickness: 1 5/8 inches (41mm) with ¾ inch (19mm) insulated glass. For 1 inch (25mm) insulated glass
sash thickness is 1 7/8 inches (48mm).
C. Sash Options:
1. Tall Bottom Rail
2. Interior Sticking
a. Ovolo
b. Ogee
c. Square
2.4 GLAZING
A. Select quality insulating glass comprised of tempered exterior, desiccant filled metal spacer, laminated
interior. Glass quality complying with ASTM C 1036. Insulating glass SIGMA/IGCC certified to performance
level CBA when tested in accordance with ASTM E 2190.
B. Glazing method: Insulating glass; ¾” and 1” over-all thickness, (altitude adjusted).
C. Glass type: Clear; Bronze; Gray; Reflective Bronze; Tempered; Obscure; Laminated; LoĒ² 272® with or
without Argon; LoĒ³ 366® with or without Argon.
D. Glazing seal: silicon bedding at interior and exterior.
2.5 FINISH
A. Exterior: Treated bare wood or latex primer available on pine units only.
B. Interior: Treated bare wood or latex primer on pine units only.
C.
Painted Interior Finish: Optional factory applied water based acrylic paint over compatible primer. Available
on Pine products only. Color – White
2.6 HARDWARE (Stainless Steel Available)
A.
Casement Crank Out:
Factory installed operating hardware:
1. Hinges: One at the sill to bottom rail and one at the head jamb to top rail. Hinges are steel coated with
Eguard. Hinge track is stainless steel. Units with a frame OM of 20” (508mm) and greater use an 18”
(457mm) wash/egress hinge or 22” (559mm) wash/egress hinge to allow the sash to slide across the
frame opening which causes the sash exterior to rotate towards the user for easy washing. Units under
20” (508mm) use dyad hinges. Using the dyad hinges means that the slide across feature, for easy
washing, is no longer a feature.
2. Operating hardware: Single arm standard coated with Eguard.
B. Locks: Multi-point, sequential, concealed locking system in the jamb opposite the hinge side. Lock handles
are removable, non-handed, and are available in the same finishes as the handles. Standard tie bar, cams
and keepers are steel coated with Eguard
2.7 WEATHER STRIP
A. Weather stripped at frame is a hollow foamed material bent around 90 degree corner to allow for seamless
corner joints, beige in color. Sash weather strip is bulb shaped glass filled material, available in white, beige
or black.
2.8 JAMB EXTENSION
A. Jamb Extensions are available for various wall thicknesses, factory applied up to 12” (305mm) wide.
B. Finish: Match interior frame finish.
2.9 INSECT SCREENS
Doc. 71374 Rev. 5/27/2011
08 52 00 - 3 Wood Ultimate Casement Storm Plus IZ3 Window - 2009
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed on: 2/10/2016 12:06 AM
SECTION 08 52 00
WOOD ULTIMATE CASEMENT STORM PLUS IZ3 WINDOW
A. Factory installed. Screen mesh, 18x16: Charcoal fiberglass; Charcoal Aluminum Wire; Black Aluminum
Wire; Bright Aluminum Wire; Bright Bronze Wire; or High Transparency (Hi-Tran) Charcoal Fiberglass
screen mesh 20x20.
1. Crank Out Models: Standard = Aluminum surround available in Satin Taupe, Stone White or Bronze.
a. Optional Wood surround with Hi Tran screening (other screening options are available). Species
will match unit species.
b. Optional Wood Retractable Screen; Hi Tran screening, Species will match unit species.
2.10 REMOVABLE GRILLES
A.
Interior removable, 3/4'” (19mm) or 1 1/8” (29mm) wide.
1. Pattern: Rectangular; Diamond; Custom pattern.
2. Finish; Match interior sash finish.
2.11 SIMULATED DIVIDED LITES (SDL)
A.
5/8” (16mm), 7/8” (22), 1 1/8” (29mm), 1 ¾” (44mm), 2 13/32” (61) wide, with or without internal spacer
bars.
1. Finish options: Pine, mixed grain Douglas Fir, Mahogany or Vertical Grain Douglas Fir.
2. Patterns: Rectangular or custom lite layout.
PART 3 EXECUTION
3.1
EXAMINATION
A.
B.
3.2
INSTALLATION
A.
B.
C.
D.
E.
3.3
Comply with Section 01 73 00.
Assemble and install window unit/s according to manufacturer’s instructions and reviewed shop
drawings.
Install sealant and related backing materials at perimeter of unit or assembly in accordance with Section
07 92 00 Joint Sealants. Do not use expanding foam sealant.
Install accessory items as required.
Use finish nails to apply wood trim and mouldings.
CLEANING
A.
B.
3.4
Verification of Conditions: Before installation, verify openings are plumb, square and of proper
dimension as required in Section 01 71 00. Report frame defects or unsuitable conditions to the General
Contractor before proceeding.
Acceptance of Conditions: Beginning installation confirms acceptance of existing conditions.
Remove visible labels and adhesive residue according to manufacturer’s instructions.
Leave windows and glass in a clean condition. Final cleaning as required in Section o1 74 00.
PROTECTING INSTALLED CONSTRUCTION
A.
B.
Comply with Section 01 76 00.
Protect windows from damage by chemicals, solvents, paint, or other construction operations that may
cause damage.
END OF SECTION
Doc. 71374 Rev. 5/27/2011
08 52 00 - 4 Wood Ultimate Casement Storm Plus IZ3 Window - 2009
CHECK MARVIN ONLINE DOCS FOR LATEST VERSION Printed on: 2/10/2016 12:06 AM
Download