SMEAR TECHNICAL MEETING 2015 GENERAL Maintaining long term measurements as before, focus again in spring measurements (Ecosystem) HYYTIÄLÄ IT New server for raw data replaces atm-raw2 2015/02 New Timo server (Linux Centos) in active use New desktop computers installed spring 2014 The data flow and connections with FMI still undefined The data transfer should be organized for both Siikaneva sites (Heikki, Teemu, Risto) Data visualisation for visitors o New TV-size screen in the main hut o Marku, Timo, Jaana and Tuukka scripts? MAIN STATION Ecosystem Footprint kaulusten kasvillisuuskartoitus (Nuria Altimir kiinnostunut?). Jokainen kaulus (54) + valuma-alueen 7 kaulusta käytävä läpi, kuvat otettu 2014 mutta nyt täytyy tehdä paikan päällä (kesä-heinäkuussa). Synkronoi am. biomassainventoinnin kanssa? Kesätyöntekijä? Pintakasvillisuuden biomassainventointi elokuussa Hyytiälän footprint-alueella 60 näyteruutua (20 x 20 cm). 1 viikko kasvien keräyksen, erottelun ja kuivauksen kanssa. Coordination with ICOS protocols. (Liisa) This year’s tree biomass sampling would be good to make also at the ICOS plots REA(Radiation)-Tower The tower will not be extended Foundations must be repaired and guys checked Single trees can be felled to keep radiation etc. sensors in clear horizon. Measurements clearly over canopy should be mounted to the mast or the measurement tower Power Uninterruptable power system o Preliminary plan made by contractor o There is consensus over the need o Board has contacted university administration Centralised compressed air and vacuum production o Main hut area Mink to the cellar 1 Meteorology Järvenpää radar to Hyytiälä late Feb- early Mar (postponed to May-June?) 2015. It is a sea container with a 4.5m antenna on top. Placed to the old ARM site close to the Ahouse. Help needed from the station personell. Move the precipitation measurements out from the old (short) FMI container The comparison between the temperature measurements 67.2, 50.4 and 33.6 m is not good. 50.4m measurement seems to be OK. 8.4m measurement has most likely blower problem. Thies wind 67.2m is broken Tower T and RH is missing o New data connection box needed (serial/ethernet server, power etc.) Delta Sunshine Sensor will also be connected to this Gas PTR-TOF spring-summer with FMI (Heidi Hellen) Diagnostics signals to new Nokeval TEI 146i calibrator excess flow sensor should be bought and installed H2O monitor for the H20 generator and dew point sensor installation Horiba mast CO offset in the analog signal shuld be studied. Calibration off in the pressure difference sensors in mast and cuvette lines LI820 removal from the setup NO and NO2 instruments to new tower cottage. Short sampling lines. One instrument from cuvette setup and one specific instrument coming in Feb 2015. Needs gases and clean air. Pressure regulators (N2, Air) to the new tower cottage. CI-APITOF continues in the new tower cottage. Scroll to the pump room with UPS. Does someone use the measurements above 67 m from the old Li-Cor profile? o The old profile could be replaced with a completely new sampling system from the bottom of the mast up to 33.6 m, with couple of new sampling levels for example 1 m and 2 m height? Is there room for this (ICOS EC storage protocol)? Radiation SpecNet NDVI and PRI sensor installation and monthly cross-calibration maintenance for at least one year. Measurements starting 2015 or 2016 spring. Location to be decided (Albert Porcar) See separate document. Skye PRI sensors should be back in February 2015. Installation by mid-March next to the Skye-NDVI (Albert Porcar) The Monitoring-PAM remains in the old phototower where trees can be more easily accessed. Regular maintenance check, data download of the Monitoring PAM has been discontinued during the last years and this can be seen in the data (longer gaps due to snow during winter). If possible, it would be good if the weekly visual check/sensor cleaning could be re-established. The data is an international precedent and there are a number of papers on the making with it… (Albert Porcar) PRITOVOC Campaig campaign does not involve input from SMEAR-II technical Staff. In practice, a Chinese PhD student from Barcelona will be staying in Hyytiälä for two months (mid March-Mid May) and conduct regular leaf-level sampling/measurements 2 in the towers at SMEAR-II. She will be also doing measurements in the Institute. (Albert Porcar) Reflected global sensor should be at 67 m for ICOS compatibility, consistency with net radiation and reflected PAR, and old time series. New sensor instead of moving the 125 sensor. New Sunshine Sensor for PAR variables should be installed. Flux New O3 analyser FOS Sextant installation. Tower or mast? Old LOZ has not been in use. o Mast COS-chamber(s) from Open University (UK)/UCLA (USA), and our COS Aerodyne to be installed with them; construction so that Aerodyne is switched to measure air concentration or EC flux then and then. Expected time late June (Helmi, Pasi K etc.) Subcanopy EC verification. It seems to produce mostly noise. Should we continue or change the site… o EC system stopped due malfunction with data logging o New setup needed – if needed Tower Li-Cor waiting for change, could SMEAR staff do it instead of Sigrid travelling to Hyde for 1 hour job? Photo (Anni Vanhatalo, Juho Aalto) New photo tower in use since spring 2014. In old tower one cuvette still in use. Shoot, soil and stem cuvettes in rotation. Birch has been measured now second year Juho and Anni will monitor the data Water accumulation guard for the photo CO2/H20 analyser/sample lines under construction (Heikki, Petri) PTR-MS will measure from cuvette and mast as before New stem cuvette for exchange and water soluble compounds under design Lite cuvette system under design -> construction NO and NOx out from the cuvette system. One in us in new tower cottage and one spare. New O3 analyser available for the cuvette. Should be simple to install Old tower can be taken partly down, but it is needed during summer 2015 by Mari METAFOR (setm CH4 and N2O). planning will be started for all enclosure upgrades (Anni: dynamic stem enclosure; Pasi/Juho/Jaana: kevytkyvettisysteemi; Mari/Jukka/Liisa: soil enclosures [for CH4, N2O, CO2]); potentially Topi's workshop could be involved, Heikki? Total revision of the old cuvette system control software and electronics will be planned. Technical details will be figured out once ALL responsible researchers have made their requirements clear (gases, chamber type, number of lines, measuring frequency and closure time etc.) online GC-MS for enclosure and air VOC concentration measurements. Planning should be started. The status of LGR measurements (broken connectors, clock setting) o nykyisessä kyvettilinjastossa kiinni olevan LGR CO/N2O laserin datavirran järjestäminen, last autumn Eki volunteered to fix this. Tree 3 the stem measurements in new tower still need some input from Heikki/Eki (Teemu Hölttä) spruce stem diameter and sapflow: Annikki's spruce measurements need to carry on, technical assistance appreciated; Summer workers Lämpötilanmittaus (esim. termopari) 3 puusta (2 mäntyä ja koivu) rungon alaosaan noin 1 cm syvyyteen ja versoon/ Teemu Hölttä (Juho & summer workers) mikrokairaus/Tuula Jyske: kolme näytepuuta, arviolta 15-30 min/kerta. Näytteet tulisi ottaa kahdesti viikossa keväällä. (Pauliina & summer workers) SOIL pitkäaikaismittaukset pääosin ennallaan Picarro 13CO2 measurement from soil profile will be continued, system works well and data looks OK (Jukka P). Yhden hukassa olleen mutta sittemmin löytyneen Tohelikammion asentaminen yhdelle Jussin Trenching-plotille • requires power and setting up data acquisition Imulysimetrikeräykset 1 päivä kuukaudessa. Kesätyöntekijä CO2-kammiomittaukset manuaalikammioilla joka toinen viikko pimeä ja valomittaukset. 1 päivä joka toinen viikko 14 kaulusta valuma-alueella. Maakammiomittaukset (N2O, CH4). SMEAR II valuma-alueen manuaalikammiot: 2 vk:n välein (Matti tietää), kesätyöntekijä, MaSa automaattikammio: putkien vaihto ja seuranta. Footprint (METAFOR projekti): mitataan vain ne kammiot, jotka sijaitsevat tutkittavien puiden lähellä, mittauksetsamanaikaisesti runko- ja latvustokyvettimittausten kanssa. Intensiivinen kevät: huhti-toukokuu (mittauksia niin paljon kuin sää sallii ja on mahdollista). Kesätyöntekijä tarve 13.4. alkaen. Automaattikammioiden toiminnan tarkistus joka viikko. Kesätyöntekijä Sadevesien ja patovesien keräys , suodatus, pH ja johtokykymittaus joka toinen viikko. 2 päivää joka toinen viikko. Kesätyöntekijä Sadekeräimien puhdistus joka viikko. Kesätyöntekijä uusia tai kampanjoita (ks tarkempi kuvaus alla) Biohiiliprojekti trenching –kokeen mittaukset, nyt uutena DOC,VOC ja N2O & CH4 METAFOR - metaanilähteet ja -nielut (Marin projekti) SiliCarbo (Miitta Rantakari) pii- ja hiilimittaukset maavedestä UUSI PROJEKTI: Jukan Biochar-projektin koealojen perustaminen (aputyövoiman tarve 2 viikkoa). Kokeeseen tulee Hyytiälään koealoja, joille levitetään puuhiiltä ja tutkitaan sen vaikutusta maan orgaanisen aineen hajoamiseen ja puiden/taimien kasvuun. Kokeeseen tulee lämpötila-antureita, todennäköisesti ruukkutaimia ja maankosteusmittauksia. Sekä maanäytteenottoa. Projektissa työssä 50% työajalla Marjo Palviainen. Help from summer worker will be needed occasionally. Jussi: trenchingiin liittyen työtä aseman väeltä vaatisi edelliskesän tapaan säännöllinen vuomittaus. Uusi ajatus DOC-mittauksista on hiukan raakile ja juttelemme siitä Miitan ja Annen kanssa ensi viikolla. Imulysimetrimittaus ploteilla voi toteutuessaan vaatia apuja tekniseltä väeltä, ainakin siinä vaiheessa kun pumppuja ja sähköjä pitää vetää alueelle. 4 • • • • • • • Trenching-kokeen kammiomittaukset 1 krt kuukaudessa (CO2-, CH4- ja N2Ovuot). CO2 kammiot: 2 vkn välein? (sama työpanos ja –intensiteetti kuin viime vuonna) N2O, CH4 kammiot: 1 krt/kk (max 15-18 kammiota/pv = 3 pv) maan kosteus, CO2 ja N2O/CH4 kammiomittausten yhteydessä. Kesätyöntekijä/gradulainen. UUTTA: imulysimetrimittaus trenchingeihin asennetuista lysimetreistä. Asiasta keskusteltu/keskustellaan Anne O:n ja Miitan kanssa. Kerran kuussa? (kytkee trenchingin ja juuristoaktiivisuuden DOC-valuntaan) kasvillisuuskartoitus trenching-ploteilta (sovittu tehtäväksi Evu Tuittilan kanssa, ei vaatine resursseja) VOC-mittaus (Mari Mäki); huhti-lokakuussa, trenching ja maaprofiilit sekä pintakasvillisuuden mittaukset, apua tarvitaan kyvettien ym. systeemien tarkistukseen (Juho) ja mahdollisesti ajoittain mittauksiin (kesätyöntekijä) Miniritsotronit (Heljä-Sisko) Miniritsotroneilla määritetään hienojuurten kasvudynamiikkaa SMEARin männikössä. Kolmen vuoden aineisto 2012-2014 on valmis ja analysoitu, laskenta talvella 2015. Kuvaamme SMEAR-männikön miniritsotroneja yhtenä päivänä kuukaudessa toukolokakuussa myös 2015, liittyen 2012 perustamaamme kasvupaikkagradienttiin Hyden ympäristössä, jossa SMEAR-männikkö on mukana. Emme tarvitse mittauksissa apua. Rahoitus työhön tulee Suomen Akatemian projektistani. Suunnitteilla on myös aloittaa kasvupaikkagradientilla tarkempi juurten kasvun fenologian seuranta maanalaisen kasvukauden alussa ja lopussa viikoittain samoista putkista (1 pv per viikko toukokesäkuu ja lokakuu) esikokeena jätetylle NSF-hakemukselle. Mittaaja on vielä auki, voisikohan touko-kesäkuun mittaukset tehdä joku SMEAR-kesätyöntekijä? Voin maksaa palkan tältä osin, siis noin 1 pv viikossa ja opetamme työn. Kamera Hydessä helpottaisi työtä (on ollut infralistalla jo vuosikaudet..). Käytimme 2010-2013 Metlalle aikoinaan hankkimaani kameraa. Viime kesänä ja ensi kesänä käytämme Tarton yhteistyökumppaneiltani lainassa olevaa kameraa. SiliCarbo pii- ja hiilimittaukset maavedestä (Miitta) Keräämme maavettä SMEARII lysimetreistä keväällä ja kesällä sateen jälkeen. Piin ja hiilen määritykset tehdään pääosin Helsingissä, saatamme tosin Hyden kaasaria muutamille näytteille. Hoidamme näytteenoton itse. ICOS ATM/meteo Päävirtauslinjoihin lisätään filtterit ennen hiljalleen tukkeutuvia virtausmittareita (1kpl jo paikallaan) new Rotronic at 33.6 m Atmospheric pressure measurements are not ICOS (AS) compatible o Risto will order (has already ordered?) ICOS compatible pressure sensor o Should be installed to measure pressure outdoors, not inside the cabin (door closed => pressure changes etc.) Generally the data logging frequency should be increased (of ICOS related parameters) Could the logging of the “ICOS diagnostics” (flows etc. including p) be moved to Picarro’s integrated computer 1 Nokeval needed 5 EC More markings in log books (for instance about installations with instrument serial numbers, calibrations etc.) o e.g. ICOS concentration data transfer to France hasn’t happened yet since the serial numbers of meteorological instruments are not known ventilation needed in the basement for gas bottles; maybe also a fan to mix air and minimize the vertical T gradient, so that the bottles don’t need to be horizontally o in principle the whole calibration setup (cylinders, regulators, sampling lines) should be in the same temperature as the instrument which is calibrated The requirements for 0…33.6 m CO2/H2O-profile measurements (storage change flux) are still open o Picarro measures at 16, 67 and 125 m heights for ICOS ATC needs o Independent system or integrated to the old profile measurements (causes need for rebuild) Protokollan mukainen eddy asennettu 33 m:n Feedback? ICOS INWIRE-instrumenttitesti Katso Siikaneva1 Kasvupannat Vanhat laitteet rikki Metlan käyttämät pannat/kokemukset Ecosystem 4 soil/biomass plots, 50-70 m distance from the mast. The pits in the catchment area are not used for ICOS-measurements, at least not as a primary source of data final planning should be done during 2015 (=”koealojen pyykitys”, exact locations of instruments in the field, power & data logging etc. etc.) however implementation mostly during 2016 Nothing done yet o INWIRE tests still ongoing o Some protocols still unfinished soil T and humidity from approx. 5 depths up to 1 m deep if possible, groundwater height if needed (mostly in SW direction) soil heat flux subcanopy PAR, measurements must be synched with the above canopy PAR! litter collectors and litter plots automatic dendrometers etc. there’s going to be quite a lot of traffic at the plots due to vegetation and soil sampling, some boardwalks are probably needed inevitably there’s going to be quite a lot of wires going around, although some things can be done wireless Soil chambers o In the beginning measurements are done with “Toheli”, n units needed o For the auxiliary data measured in parallel (T, humidity,?) no big changes needed in data collection? o Measurements should be done further away from the catchment area o In the future larger chambers should be used (make/order larger ones when there’s need for new ones, coordinate with the chamber revision) This year’s biomass sampling would be good to make also at the ICOS plots Aerosols (Pasi Aalto, Jonathan Duplissy) 6 DMPS, CPC and APS working just fine. DMPS rebuild when we have the time. New Hitu computer installed 2014 New computer to new tower container installed 2014 (PSM, NAIS, DMPS…) APS was in intercomparison workshop in Leipzig, performing fine New APS program in use starting 12/2014 During 2014 there was a DMPS running at the BAECC field and in the new tower. Those measurements are finished. Old CPC TSI3022 was changed to new model TSI3775 MAAP, Aetahlometer, Nephelometer, CAPS and PSAP running fine, some inlet changes done for CAPS 12/2014. MAAP has now a pump with control. New optical inlet dryer under planning/testing, The current design is not sufficient enough for MAAP, not enough flow capacity. Sampling line should be also simplified, especially for CAPS. The new design might have some capacity problems also, testing this winter in Helsinki. With the new inlet, it might be good idea to move the inlet away from the corner, even if FMI radiation setup will be moved away. o Might cause a need for bigger compressor SHARP running. Some unstable periods. CCNC running just fine, some program crashes Volatility-DMPS running Impactor sampling will continue. How about the data quality. ELPI will continue Tower TwinDMPS (02/2015) Maintenance and improvement of Tower-PSM Container-PSM installed again in near future Ice Nucleation Counter, already this year? Ions (Hanna Manninen) NAIS in tower container o When? NAIS in Hitu-cottage or in Cessna BSMA in REA-cottage SIGMA in radiation tower Radioactive radiation (Alessandro Franchini, Xuemeng Chen) Milan radon running fine Analytical chemists (Kari Hartonen) Portable GC-MS spring-autumn 2015 for NTME collections and analysis SPME cuvette measurements with Jaana Bäck FMI measurements (Hannele Hakola, Jussi Paatero…) Hg measurements PAH measurements o PAH and Hg fallout measurements should be moved to the roof platform of the FMI container o Platform needs to be extended Marga 7 Marga flux Radioactivity measurements moved from Hitu-cottage summer 2015 FMI old container to the container site? FMI cloud radar to Hyytiälä 2015 Heidi Hellen SA-project measurements KUIVAJÄRVI the 3 underwater PAR sensors need to be checked. They are in Helsinki now. Eventually to be sent to Licor. They should be put back on the lake possibly in April (Risto, Ivan). 2 or 3 temperature profiles from water, to catch internal waves and thermocline slopes; temperature chains to be installed in May(Anne, Ivan, Risto) near-bottom thermistor chain and oxygen probes (probably also in May); Arkady Terzhevik from Russia knows (Russian visitors, Anne, Ivan) Short campaign (one week) at the end of August with Viikki turbulence profiler and the Sally MacIntyre SCAMP (not yet confirmed, depending if Sally is able to come to Finland) (Ivan, Anne, Sally). One week manual gas sampling under the ice focusing on spatial variability, probably on week 7 (Ivan, Anne, one Russian visitor). Lidar campaign in summer. One Lidar will be installed on the raft. Exact starting date and duration of the campaign to be decided soon, probably in May-June. (Ivan Mammarella and Ewan OConnor) SiliCarbo (Miitta Rantakari) o Määritämme järvivedestä piipitoisuuksia. Näytteet on tarkoitus ottaa samalla, kun järvestä muutenkin otetaan vesinäytteitä (minulla ei ole Timon listaa, en tiedä mitä siellä sanotaan, mutta synkronoimme näytteenoton). Piimääritykset tehdään Helsingissä. Ainakin heinäkuussa SMEAR kesätyöntekijän apu järvinäytteenotossa olisi tervetullutta. o Asennamme järveen kaksi sedimenttitrappia (samoin kuin viime kesänä). Hoidamme itse näytteenoton. Kuitenkin jos SMEAR kesätyöntekijä heinäkuussa ehtii yhden tai kaksi kertaa vaihtamaan trappien putket, olemme kiitollisia (n. 2h työ/kerta). SIIKANEVA 1 Gill anemometer and 7200 Licor to be installed to make the site more towards ICOS Class II (Risto) Automatic chambers, plant chambers (Topi?) New measurement platform (Meronen ?) Dam in the ditch/outlet and flow rates and water concentrations? (Janne R, EevaStiina, Meronen ?) 4-channel radiometer settings problem, quantization problem buy a spare LGR. (LGR, which model?), just to have a spare instrument. Pekka and later Risto will handle this the old Tprof doesn’t make sense, heavily dampened signal due to moss overgrowth? replace the logger, not been configured correctly (quantization problem). Some changes are needed ---> Pekka will contact Eki. A new logger with larger memory would be also nice (higher measurement frequency for met-data?) o PC and Nokevall??? check the ch4 prof data with the new sampling settings after 30th Nov by Risto/Tiia LGR problems 8 o doesn’t work as of now (21.11.2014) o timelag problem o noise problem (doesn’t seem to affect the calculated fluxes, but still…) o in parts of some raw files, missing values or constant values are logged o a period when only the CO2 channels were logged, with “-1” written for CH4 o maintainance in Helsinki since dec 2014 raw file size is varying; sometimes a few days in a row consist of very short files. Computer/logging issues,Computer changed in Dec2014 reasons for the notably different level of 2012-2013 CH4 fluxes. check the relative change in CO2 fluxes and SEB closure; happened after the anemometer was changed? needs a new computer - done dec 2014 LI-7000 is down, ref. gas over + other problems? – to be done in Jan 2015 ICOS INWIRE remote flux measurement setup prototype at Siikaneva1 o there is already small tower plus some soil instruments installed in autumn o transport from Sweden and installation during first half of April o details to be discussed, one option is van&ship transport to Hyde via Umeå&Vaasa instead of using commercial transport services o fuel cell, 500 l tank, batteries integrated in one box quite heavy even when empty needs additional support structures to avoid finding everything at the bottom of the peat layer in summer fuel is methanol o 2 solar panels about 20 kg each, also need some infrastructure o CO2 emissions from the fuel cell may affect the permanent flux measurements fuel cell will not be used unless the Inwire setup can be installed far enough o SMEAR staff take care of the timberwork and on-site transport o technician from Amsterdam will come to Hyde to set up the instrument tower, his timetable is flexible o communication uses 3G network, data directly to Amsterdam o setup removed in summer when the summer worker rush is over (late June?) SIIKANEVA 2 floating chambers (“wetland group”) dissolved CO2, dissolved CH4 on ponds (“wetland group”), profiles? isotopes from floating chambers (Vesa Palonen jne.) Siikaneva-2 generator problems (since Sep. 2014), caps in data Siikaneva-2: need exact conversion coeffs o for METEK, uvw-coeffs known, but NOT Ts o for PAR, PAR – coeffs known (Dec 2014) CAMPAIGNS Marin METAFOR -projektin työt (maa+puumittauksia): Tekniset tarpeet ja toiveet Torni märälle paikalle, jotta pääsemme käsiksi latvuston (koivu erityisesti) metaanipäästöihin. Torni pitäisi asentaa huhtikuun alkuun mennessä, jotta päästään mittaamaan huhtikuussa, ennen kuin lehdet puhkeavat. Tarkoitus olisi saada mitattua 3-6 puuta, erityisesti koivu, 9 manuaalisesti operoitavilla oksakyveteillä (Mari tilaa lisää jo olemassa olevien lisäksi). Näytteiden analyysit tehdään kaasarilla. MÄRKÄ PAIKKA Mahdollisuuksia: - rakennustelineiden vuokraus rakennusfirmalta - Haapastensyrjän torni? - Mahdollisesti useita eri telinesettejä, jotta pääsemme käsiksi mahdollisimman moneen koivuun Mittausten tueksi sap-flow-mittaukset jokaiseen tutkittavaan puuhun - min. 3 koivua, 3 kuusta, 3 mäntyä – riippuen miten torni saadaan asetettua Kysymyksiä: - Sähköistys sap-flow-mittauksia varten, onnistuuko? - Loggeri sap-flow-mittauksille, onko vapaita loggereita? Jos em. sähköt ja loggeri järjestyy, Teemulla on tiedossa hlö (Risto Punkaharjulta), joka osaa pystyttää mittaukset, ja joka kävi viime vuonna pystyttämässä Annikin mittaukset. Aikataulu: Maalis-huhtikuu: Tornin pystytys märälle alueelle. Tarvitaan teknistä henkilökuntaa avuksi (pari pv?) Forest floor chamber measurements - only those chambers measured which are close to the trees of interest (3 wet site, 4 middle-wet, 3 dry + MaSa) 10 - measured at the same time with tree stems/shoot fluxes (April-August?) Stem chamber measurements (as in 2014) - conducted parallel to shoot and forest floor flux measurements, except semi-wet site where we don’t have a tower - pine, spruce, birch (as in 2014) Shoot chamber measurements - wet and dry site - wet site: new scaffold tower, birch and pine trees (3 each if possible, or at minimum 3 shoot chambers / tree species – even 3 chambers in one tree individual), in total 6 shoot chambers - dry site: old scaffold tower, 3 pine trees, 3 shoot chambers Technical assistance needed (March, April-May) - scaffold tower to the wet site (to the place in March?) - sap-flow measurements to trees at the wet site (Teemu responsible?) - poles etc. to help fixing shoot cuvettes in the trees at the wet site Extra workers / summer workers - David from Germany (Aino Korrensalon kautta tuleva harjoittelija?), wants to do a training period for min. 6 weeks. Needs accommodation - Summer worker, 3 months (13.4.-15.7.) to help in 1) flux measurements (intensively in April-May) 2) vegetation survey (2 weeks in total) 3) vegetation sampling (possible 2 days/2 weeks) 4) Data processing from GC outputs to input file formats for flux calculations (matlab format), rainy days (1-2 day/week) Siikaneva campaign spring 2016 PSM, NAIS, CI-APiTOF Electrode effects close to ground level (Hanna Manninen) Vertical ion profile measurements with SIGMA and electric field mill at the BAECC filed, winter 2015 Cessna Flight campaigns on May-June, August-September 2015 (preliminary schedule, Markku discusses with Erkki Järvinen on March). 11 Flight instrumentation and inlet system need to be in lab on March for detailed lab tests (pressure tests etc) March-May reserved for laboratory tests in Helsinki (Riikka, Juha et al.) Technical help needed from Hyytiälä for installation and disassembling the flight rack from the airplane (one person for four days total, 2 campaigns x 2 days) o TOPI Technical help needed for the NAIS shipping from Hyytiälä to Kumpula for the laboratory tests on March (NAIS inlet to Helsinki, we need to have second one for the PSM) Test to install PSM with the short inlet tube (hole in the window) used previously for the NAIS, also the PSM testing with the new CPC (both TSI 3010 and AIRMODUS one), Help from Hyytiälä would be needed to make the modifications for the electricity of the CPCs." Riikka Väänenen contact person NAIS intercomparison campaigns Cottage vs tower NAIS in Hitu-cottage VÄRRIÖ MAIN STATION General pitkäaikaismittaukset ekosysteemien toiminnasta subarktisella alueella, Soklin mahdollisesti käynnistyvän kaivostoiminnan seuraukset, Suomen kylmin paikka Sokli –projekti jatkuu; puoliautomaattisia/manuaalisia veden, kasvillisuuden ja ilman seurantapisteitä (Nessling -hanke), hankinta ja asennus tehty kesällä 2014, jotain teknistä apua tarvitaan suunnittelussa ja asennuksissa, pääosan hoitavat aseman vakituiset työntekijät ja Laura Matkala; kylmän paikan käyttö mittauksissa vielä auki; vesimittaukset samoin Continuation of carbon balance monitoring (soil + cuvettes) for Värriö. (Jukka + Frank) Kesätyöntekijät o maa: CO2-kammiomittaukset manuaalikammioilla joka toinen viikko pimeä ja valomittaukset, 1 päivä joka toinen viikko 12 kaulusta SMEAR I-asemalla. Kesätyöntekijät o Automaattikammioiden toiminnan tarkistus joka viikko SMEAR I-asemalla. Kesätyöntekijät Pintakasvillisuuden biomassainventointi elokuussa Värriön footprint-alueella 20 näyteruutua (20 x 20 cm). 2 päivää kasvien keräyksen, erottelun ja kuivauksen kanssa. Tämä on laajempi kuin 20x20cm ruudulla tehty biomassainventointi SMEAR I kaulusten vierestä? Kesätyöntekijät, Jukka ohjeistaa CO2-vuomittaukset rajavyöhykkeellä Kajarin poroaitagradientilla 1 krt kuukaudessa. Kesätyöntekijät Karikekeräimien asennus SMEARI-asemalle kesäkuun alussa puustokarikkeen mittausta varten. 1 päivä. Kesätyöntekijät, Jukka ohjeistaa Avustaminen Yojiro Matsuuran kenttätöissä (juurten kaivuu), jos on aikaa. Yojiro Matsuura tulee itse, ja hänellä on myös mukana oma opiskelija/post doc, joka tekee suurimman osan töistä. Yhteyshenkilö Jukka. 12 Biomassapussien keruu ja käsittely porolaidunnus- ja metsäpaloalueilta Värriöstä ja Sodankylästä (muutama päivä, JH) Kesätyöntekijät Lumilinjat entiseen tapaan (vakiohenkilökunta) marjakoealat, kesällä 2015 päällekkäinen otanta 10x10 ja 10x 1x1 ruuduilta (kesätyöläiset + vakinaiset) fenologia, pesinnät, huiskutukset, valorysät, myyrät ja METLAn marjakoealat entiseen tapaan Air conditioning this spring Compressor problems More space to the station Rebuild of the met tower Nothing done to improve the station thunder storm security Nothing done to protect the gas instruments serial interfaces from thunder strikes Should we change the thunder storm instructions to avoid long breaks during summer time? Someone (Lisa Wingate?) would like to bring webcam to the met tower (Sigrid) Meteorology Temperature and WS gradient not needed and in bad shape. Finish the measurements Thies WS/WDIR probe broken. Change that. Improve the T/RH probe setup at 2m height Is station pressure OK? Radiation Nothing new. Check all against reference instrument during spring/summer, especially the UV sensors against the new reference sensors. Gases New NO2 analyser exits, but does not fit to the gas rack Flux Met Tower EC working fine, no changes Wetness sensor integrated to the measurements. Does this mean the same kind of sensor there was in the past? Subcanopy EC Li-7500->Li-7200 this spring. No CH4 EC. Conversion of the old Li-7500 to mobile system to be used to verify the subcanopy EC measurements around (for example Hyytiälä) Tree Dendrometer bands. Sigrid? Puiden pituuskasvu, versomittaukset tornissa joka aamu. Kesätyöntekijät läpimitanmuutokset 2 puussa, working only at the tower, the other tree is not working. Eki will be given instructions (Teemu Hölttä/Lauri Lindfors) to fix this in spring. Photo Measurements with four cuvettes will continue. Station personnel and summer workest will maintain. Anni Vanhatalo will monitor and maintain 13 Ladders will not reach the cuvettes in near future. New way to maintain cuvettes needed. Quality of T and PAR is not good. Differences (some degC) in temperatures between cuvettes and some noisy thermocouples exist. PAR measurements have some cyclic noise since autumn 2014 . LiCOR mittausten tarkkuus? peräkkäisten mittausten ero suurempi kuin URAS-aikana (LAATU-koodinpätkä tarkistusta varten) Suomeksi: data on siis kohinaista. Kyvettien data, mukaanlukien kohinat, on mukana varrio_data-koodistossa, noita Mathematicakoodeja ei kukaan aikoinaan tuntunut oikeasti käyttävän. Aerosol DMPS and CPC running fine. DMPS rebuild when we have the time. COLD STATION Road, electricity, housing DMPS, meteorology AROUND VÄRRIÖ Replacement of current "Nuortti", "Tunturi", "Saunaranta" air temp loggers; Installation of 15 new Air temperature loggers going from SMEAR I to Ainijärvi, including "Cold spot" and Ykkönen (old soil temp gradient); some loggers are already purchased; - envisaged to be installed first week in March by Sigrid Using Sonera masto for future measurements o EC on the top of Ykkönen fjell at Sonera Tower , if Sigrid’s Academy post doc application gets through HELSINKI GENERAL New virtual server hippuko replaced hippunen Space for the raw data from department servers, replaced atm-raw1 Data flow to databases and CSC IDA in constant development URBAN STATION General New computer (Linux Debian) for the roof measurements All data lines from the tower will be optically isolated before summer 2015. FMI will also follow (Anemometer and radiation measurements) Meteorology Tower temperature profile OK Tower WS and WDIR just from the top 3D Metek T, P, WS, WDIR and RH from the roof OK. Mainainance? New(old) visibility sensor installed New PWD installed Radiation 14 Checking of the new radiation measurements in the tower New up/down global + IR sensor in the tower PAR up in the tower and at roof still present IR UP at the roof still present. Not showing the same as tower. Temperature compensation still not done right. Gases PTR-TOF flux measurements late 2015 or early 2016 Flux Checking enclosed-path measurement setup. Particularly heating of the inlet should be fixed. Problems with the EddyCPC. The TSI3781 water CPC is a bit unreliable and faces freezing problems during winter time. New box with a new CPC? The EC measurements with TSI OPS were not successful. Some other instrument? Tower Li-Cor waiting for change, who, when??? Aerosol PSM running (Lauri Ahonen) DMPS rebuild during 2014. CPC is the Airmodus A20. Running fine. Ions AIS3 for continuous measurements? Flux HOTEL TORNI Upgrade of particle flux measurements, OPS here? TREE ANU: Rutiinihuoltoon keväällä kuuluu sapfluxneulojen huolto. Ja niiden vaihto tarvittaessa (6 kpl) ja läpimitanmuutosanturien huolto, kaikkiaan noin 1,5 työpäivää yhdeltä hengeltä (Janne J). Sapfluksineulojen teon työaikavaateesta ei mulla ole tietoa. Em. toimilla Viikin automaattimittaukset pyörii jos ei tule suurempia laiterikkoja tms. Tähän saakka on joka vuosi mitattu versonkasvua touko-heinäkuu n. 3 x vkossa, vie noin 10 t viikko. Jatketaanko, en tiedä. Teemu ja Jukka miettinevät mitä he haluavat mitattavan ja miten se järjestyy. Viikissä ei ole nyt toimivia steadytemp palikoita eikä neuloja eli jos ne halutaan, on rakennettava ja asennettava, tuplannee työaikatarpeen. OTHER SITES CHINA Exchange the DMPS during spring 2015 AIS changem service? K-PUSZTA 15 DMPS runs fine. Exchange the DMPS during 2015. DOME-C DMPS, PSAP, Nephelometer (Aurora), OPS. Some problems with DMPS. NUMMELA Measurements finished VANAJANSELKÄ lightning protection (Topi?) precise CO2 concentration in the air (Risto, Maria) dissolved CO2 (pCO2), (Risto, Maria) net radiometer into more representative place (Risto, Maria) floating chambers for N2O and CH4 (Anne, Lammi group, Maria) N2O and/or CH4 EC, if the floating chambers show big fluxes (to be moved to 2016 in any case) 16