Babcock Personnel Std Size Roof Hatch G3630 - Babcock

advertisement

SPECIFICATIONS

Roof Hatches 07 72 33

SECTION 07 72 33

Roof Hatches

PART 1 - GENERAL

1.1 SUMMARY

A. Section includes:

1. Roof Hatches. a. Personnel Series metal, single door hatches used by personnel.

2. Accessory Products for Roof Hatches a. Safety Railings for all roof hatches b. Safety posts for vertical ladder access roof hatches

B. Related Requirements:

1. Division 055000 “Metal Fabrications” for metal vertical ladders, ships’ ladders and stairs for access to roof hatches

1.2 COORDINATION

A. Coordinate layout and installation of roof accessories with [roofing membrane and base flashing and interfacing and adjoining construction] to provide a leak proof, watertight, secure and noncorrosive installation.

B. Coordinate dimensions with rough-in information or Shop Drawings of equipment to be supported.

1.3 ACTION SUBMITTALS

A. Shop Drawings:

1. Indicate configuration and dimension of components, adjacent construction, required clearances and tolerances, and other affected Work. a. Hatch Units: Show types, elevations, thickness of metals, and full size profiles. b. Hardware: Show materials, finishes, locations of fasteners, types of fasteners, locations and types c. of operating hardware, and details of installation.

General: Show connections of units and hardware to other Work. Include schedules showing location of each type and size of unit.

B. Product Data: Manufacturer’s technical data for each type of hatch assembly, including setting drawings, templates, finish requirements, and details of anchorage devices.

1. Include complete schedule, types, locations, construction details, finishes, latching or locking provisions, and other pertinent data.

1.4 CLOSEOUT SUBMITTALS

1. Installation, Operating & Maintenance manuals

1.5 QUALITY ASSURANCE

A. Regulatory Requirements:

1. OSHA 29 CFR 1910.23 Guarding floor and wall openings and holes

2. OSHA 29 CFR 1926.502 Fall protection systems criteria

3. International Building Code (IBC) Section 1013.6 Roof Access

4. International Building Code (IBC) Section 1009.11 Means of Egress, Stairways, Stairway to Roof

9300 73 rd Avenue North, Brooklyn Park, MN 55428 www.BabcockDavis.com

PH

888.412.3726

FX

888.312.3726

SPECIFICATIONS

Roof Hatches 07 72 33

1.6 WARRANTY

A. Provide manufacturer's standard 5 year warranty. Roof hatches shall be free from manufacturing defects in materials and fabrication for a period of 5 years from the date of shipment. Should a product fail to function in normal use within this period, manufacturer shall furnish a replacement or new part at Babcock-Davis ’s discretion.

PART 2 - PRODUCTS

2.1 MANUFACTURER

1. Babcock-Davis

9300 73 rd Ave N

Brooklyn Park, MN 55428

Toll Free Hotline: 888.412.3726 www.Babcock-Davis.com

2.2 PERSONNEL ROOF HATCH

Description: Personnel Series are hatches with metal, single door covers used by personnel to gain access up to roof areas.

A. Acceptable Manufacturers: Subject to compliance with requirements of the Contract Documents, acceptable manufacturers are as follows or approved equal:

1. Babcock-Davis, Model [BG3630] [BG3054] [BG3636] [BG4848]

B. Type and Size: Personnel Single-leaf metal lid, [BG3630, 36 by 30 inches (900 by 750 mm)] [BG3054, 30 by

54 inches (750 by 1370 mm)] [BG3636, 36 by 36 inches (900 by 900 mm)] [BG4848 48 by 48 inches (1220 by 1220 mm)]

Verify load requirements with authorities having jurisdiction. See Babcock-Davis for additional options with higher minimum external live load ratings

1. Loads: Cover stiffened to withstand a live load of 40-lb/sq. ft. (1.9-kPa) with a maximum deflection of

1/150 of the span and 20-lb/sq. ft. (0.95-kPa) internal uplift load

2. Hatch Material: a. Cover: [14 GAGE GALVANNEAL STEEL][11 GAGE ALUMINUM] cover with 1 inch rigid insulation covered by 18 gauge (0.040 inch) aluminum cover liner.

Curb height in first paragraph below may be determined by adding thickness of roof insulation to the minimum base flashing height recommended by roofing membrane manufacturer or established by office practice. b. Curb: [14 GAGE GALVANNEAL STEEL][11 GAGE ALUMINUM] with a single wall curb with integral railing ready EZ tabbed counterflash mounting flange. Mounting flange continuous around base of frame.

1) Fabricate curbs to height of 12 inches (305 mm) above roofing surface unless otherwise indicated.

2) Sloping Roofs: Where slope or roof deck exceeds 7:12, fabricate curb with perimeter curb height that is tapered to accommodate roof slope so that top surfaces of perimeter curb are level.

First option in “Finish” Subparagraph below applies only to galvanneal steel sheet. c. Finish: [TGIC Polyester Powder coat paint] [MILL FINISHED ALUMINUM] d. Color: [RED OXIDE][HIGH REFLECTANCE WHITE] e. Insulation: 1 inch (25mm) Polyisocyanurate in Curb and 1 inch (25mm) polystyrene in Cover

9300 73 rd Avenue North, Brooklyn Park, MN 55428 www.BabcockDavis.com

PH

888.412.3726

FX

888.312.3726

SPECIFICATIONS

Roof Hatches 07 72 33 f. Hardware: Zinc plated steel

1) Hinge Assembly: Pintle hinge with stainless steel hinge pin

2) Spring: Gas spring with integrated damper

3) Hold open device: Automatic zinc plated steel hold open arm with red vinyl grip handle.

4) Latch: Zinc plated steel spring type slam latch with inside and outside operating turn handles and padlock hasp provisions.

5) Pull handle: Interior pull down handle, powder coated safety yellow

6) Gasket: Extruded EPDM adhesive back seal, continuous around cover

2.3 ACCESSORY PRODUCTS

Retain one or both "Safety Railing System" and "Ladder-Assist Post" paragraphs below; revise to suit Project. If retaining both paragraphs, indicate location of each on Drawings or by inserts. Consult authorities having jurisdiction for their requirements. See the Evaluations.

A. Safety Railing System: Roof-hatch manufacturer's standard system including rails, clamps, fasteners, safety barrier at railing opening, and accessories required for a complete installation; attached to roof hatch and complying with 29 CFR 1910.23 requirements and authorities having jurisdiction.

1. Acceptable Manufacturers: Subject to compliance with requirements of the Contract Documents, acceptable manufacturers are as follows or approved equal: Babcock-Davis model: SRC

2. Height: Height: [ 42 inches (1060 mm) ] above finished roof deck.

3. Rails: a. Material: Galvanized-steel pipe, 1-1/4 inch (31 mm) , (1.66 inch outside diameter) schedule 40 pipe b. Fittings: Cast aluminum alloy with set screw hold c. Mounting brackets: 3/16 inch (4.75 mm) steel, zinc plated with nut backing plate d. Exit: [Self closing gate, Galvanized steel 1 ¼ inch (32 mm) tubular steel self closing with coil spring][Chain: 3/16 inch (4.76mm) zinc plated steel like chain with spring clip ends]

4. .

B. Ladder Assist Post: Roof-hatch manufacturer's standard device for attachment to roof-access ladder.

1. Acceptable Manufacturers: Subject to compliance with requirements of the Contract Documents, acceptable manufacturers are as follows or approved equal: Babcock-Davis model: SP

2. Height: Height: [ 42 inches (1060 mm) ] above finished roof deck.

3. Materials: [Steel tube] [Stainless steel] [Aluminum].

4. Post: 1 ½” x 1 ½” x 1/8”.

5. Finish : [STEEL YELLOW POWDER COAT (Model BSPY)] [STEEL HOT DIP GALVANIZED (Model

BSPG)] [STAINLESS STEEL TYPE 304 (Model BSPS)][ALUMINUM MILL (Model BSPA)]

PART 3 - EXECUTION

3.1 EXAMINATION

A. Verification of Conditions: Examine site conditions under which work of this Section will be performed.

1. Identify conditions detrimental to providing proper quality and timely completions of work.

2. Do not proceed with installation until detrimental conditions have been corrected.

3.2 INSTALLATION

A. Comply with manufacturer's recommendations.

B. Securely anchor roof accessories in compliance with manufacturer's instructions.

9300 73 rd Avenue North, Brooklyn Park, MN 55428 www.BabcockDavis.com

PH

888.412.3726

FX

888.312.3726

SPECIFICATIONS

Roof Hatches 07 72 33

C. Set units plumb, level, and true to line without warp or rack.

D. Incompatible Materials: Apply protective coating to separate aluminum from incompatible materials.

3.3 ADJUSTING

A. Adjust movable parts for smooth operation.

B. Operational Units: Test-operate units with operable components. Clean and lubricate joints and hardware.

Adjust for proper operation.

3.4 CLEANING

A. Clean exposed surfaces per manufacturer's written instructions. Touch up damaged metal coatings.

END OF SECTION

9300 73 rd Avenue North, Brooklyn Park, MN 55428 www.BabcockDavis.com

PH

888.412.3726

FX

888.312.3726

Download