John Deere 70 Series Combine Calibration Yield Calibration IMPORTANT: Mass flow sensor must be calibrated every year to achieve accurate grain weight measurements. Standard calibration must be performed in every crop that is harvested. Low Flow calibration must be performed to obtain improved levels of accuracy in situations where large variations in grain flow rates occur. 1. From diagnostics and calibration icon (A), rotate selection dial (B) until calibrations menu (C) is highlighted 2. Press Confirm switch (D) and rotate selection dial until Yield is highlighted. 3. Press confirm switch and rotate selection dial until enter icon (E) is highlighted. 4. Press Confirm switch and advance to next page. NOTE: Operator must perform the standard calibration before the low flow calibration 5. Rotate the selection dial (A) until one of the following icons is highlighted: Next Page Icon (B) – allows to advance to next page of calibration. Weight Icon (C) – allows to enter scale weight in calibration factor once scale weight is known from elevator. Comp Number Reset Box (D) – allows to reset the low flow calibration. Calibration Factor (E) – allows to input a calibration factor number that was figured using a formula. 6. Press Confirm switch (F) once desired selection is highlighted. 7. Rotate selection dial until one of the following icons is highlighted: Next Page Icon (B) – allows to advance to next page of calibration. Standard Calibration Mode Box (C) – allows to perform a calibration to obtain an improved level of accuracy in situations where there are large variation in grain flow rate. Low Flow Calibration Mode Box (D) – allows to perform a calibration to obtain an improved level of accuracy in situations where there are large variations in grin flow rate. 8. Press confirm switch (E) once desired 9. Standard Calibration Mode Rotate selection dial until next page icon is highlighted and press confirm switch OR Low Flow Calibration Mode Instantaneous Flow Rate (E) – arrow below bar graph indicated instantaneous flow rate. Standard Calibration Point (F) – green dot indicated standard calibration point (will be red if a scale weight for standard calibration has not yet been entered). Average Flow Rate (G) – red circle indicated average flow rate during low flow calibration. NOTE: When calibrated correctly, red circle should end up toward left side of bar graph within range area (H) If scale weight is not known, rotate selection dial until enter icon (B) is highlighted and press checkmark. Operator can continue harvesting until scale weight is known. 10. Scale Weight is Known or Returns from Elevator Rotate selection dial until weight icon (A) is highlighted and press confirm switch. Rotate selection dial until scale weight box (B) is highlighted and press confirm switch. Using numeric display, rotate selection dial until desired digits are highlighted and press confirm switch. Rotate selection dial until enter icon (C) is highlighted and press confirm switch to return to calibration menu Rotate selection dial until next page icon (D) is highlighted and press confirm switch to follow instructions shown on remaining screens.