NEW COMMERCIAL APPLICATION AND SITE PLAN REVIEW Building Department, 517 8th Avenue East, Williston ND 58801 Phone: (701) 577-8115 Fax: (701) 577-2081 Project Name: Estimated Cost: Property Location (Legal Description - Lot, Block, Addition): Property Address: Existing Use of Land/Bldg: New Construction, Addition, or Remodel: Proposed Use of Land/Bldg: Parcel Size (sf): Number of Stories: Detailed Project Description: (please fill out separate permit for each building, if multiple buildings): Total Square Footage of Building: Units: Overall Height: Number of Off-street parking spaces required: Number of Off-street parking spaces provided: PROPERTY OWNER: Name Daytime Telephone Number: Mailing Address: Email: CONTRACTOR Name: Name and Email of Contact Person : Mailing Address: Daytime Phone #: ND License #: CONTACT PERSON (FOR PURPOSE OF PROCESSING THIS APPLICATION): Name of Contact Person: Name of Firm, if applicable: Mailing Address: Daytime Phone Number: Email Address: SUB CONTRACTORS Zoning District: Plumbing: ND License # Occupancy Classification: Heating: ND License # Type of Construction: Electrical: ND License # I hereby acknowledge that this application is not a Building Permit, nor does it authorize the start of construction. __________________________________________________ Signature of applicant __________________________________ Date The following information is required on all site plans submitted for approval. I. GENERAL INFORMATION A. Two (2) full sets of plans to scale. If available, please also provide an electronic copy. B. Project summary information a. Name, address and telephone number of owner/developer b. Name of proposed development c. Legal description of property C. Name, address and telephone number of engineer, surveyor and architect. D. North direction indicator E. Scale including graphic or numeric scale F. Date (original and all revisions) shown on all sheets. G. All dimensions II. EXISTING CONDITIONS A. Parcel boundary lines of the property with dimensions and area (platted dimensions) B. Location of any non-access control lines, with dimensions and area (platted dimensions). C. Location, width and identification of existing easements (both public and private) D. Building setback dimensions E. Existing topographical features, contour lines for slopes greater than five percent, and existing drainage patterns. F. Existing buildings, structures, driveways (on-site with elevations and across adjacent public rights-of-way), parking and loading areas, outdoor storage areas, fire lanes, and any other manmade features, dimensioned and clearly distinguished from proposed improvements. G. All adjacent and on-site streets, including dedicated right-of-way width, pavement widths, curb and gutter locations, curb elevations (or street elevations where no curb is in place), sidewalks and curb ramps. H. Within and/or adjacent to property: existing municipal utilities including light poles, water and sewer mains, service lines, connections, curb stops and valves, manholes, hydrants, inlets, and any other stormwater facilities (location and size). I. The boundaries of any floodway, floodway fringe, 100-year floodplain, streams and/or wetlands. III. PROPOSED CONDITIONS A. Limits of any proposed demolition. B. Proposed street cuts and any street land and/or sidewalk closures. C. Proposed new and/or relocated municipal utilities including mains and service lines (location and size), connections, disconnections, curb stops and valves, manholes, hydrants (with distance to building), inlets and any other stormwater facilities (location and size), including sidewalk trench drains. 2 City of Williston Commercial Site Plan Review Checklist Proposed Conditions (continued) D. Proposed buildings and structures, with locations, footprints, entrances, area by floor, furnished floor elevation, building construction type, number of stories, and distance of buildings from other buildings and/or property lines. The building construction type and the use of automatic fire suppression systems should be clearly indicated. E. Proposed driveways, including distance from lot lines, width at top, and relationship to non-access control lines. Any proposed driveway closures. For rural roadway approaches, add the location and diameter of culverts. F. Proposed off-street parking areas, including dimensions, elevations, setbacks and number of spaces. List number of parking spaces provided and how calculated. G. Proposed sidewalks and/or trails, both on-site and within adjacent right-of-way, with locations and dimensions. Proposed crosswalk ramps at corner lots. H. Proposed fencing, if located across a drainage easement, and all proposed retaining walls (location and height). I. Dumpster (or any other solid waste handling facilities) location, size of dumpster (verify need with Public Works), dimensions of concrete pad (must be level and a minimum of 4” concrete), and any proposed screening labeled with height and material (there must be a 24” clear zone on all sides of pad and no overhanging structures, vegetation or utilities). Contact Public Works regarding dumpster enclosures. J. Proposed fire access features, including location of hydrants, location and dimension of fire lanes, and height of any overhead obstructions. A 45-foot turning radius is needed for adequate clearance for turns. A minimum vertical clearance of 13’6” is needed to accommodate vehicles. K. Proposed contours lines for slopes greater than five percent. L. Copy of recorded common use agreement if multiple-family, commercial or industrial with separate ownership (common water, sanitary or drainage facilities; common access drives, lanes and lots; access easement to backyard area.) LANDSCAPING PLAN REQUIREMENTS A landscaping plan is required for the construction of any principal commercial, industrial, institutional, or multi-family building; for the installation of any parking area or the expansion of any existing parking area by six or more required off-street parking spaces; and for a change in the use of the property that requires rezoning to a more intensive zoning classification or a special use permit. Copies of the City’s landscaping and screening ordinance can be found online at www.cityofwilliston.com. Ordinance No. 959. 3 City of Williston Commercial Site Plan Review Checklist IV. LANDSCAPING PLAN A. North point and scale B. The boundary lines of the property with dimensions and areas C. The location of all driveways, parking areas, sidewalks, structures, utilities, or other features, both existing and proposed, affecting the landscaping of the site. D. The location, common name, scientific name to the species level, size and quantity of all existing trees, shrubs or other vegetation intended for use in meeting the requirements of the City’s landscaping and screening requirements. E. The location, common name, scientific name to the species level, size and quantity of all proposed landscape materials. F. The location and height of any proposed earthen berms, masonry fences, or other features used to meet the City’s landscaping or buffer yard requirements. G. The location of any existing and/or proposed easements. H. The square footage of each interior parking lot landscaping area and the overall square footage of all interior parking lot landscaping areas shown. Failure to provide required information and documents will result delay in processing your permit application. Also, please write legible so it is able to read easily. 4 City of Williston Commercial Site Plan Review Checklist BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (This Information to be copied and placed on drawings) 1. GENERAL INFORMATION Name of Project ________________________________________________________________ Address _____________________________________________________________________ Proposed Use _________________________________________________________________ Owner or Authorized Agent ______________________________________________________ Phone ________________ Fax __________________ E-Mail___________________________ Contractor ___________________________________________________________________ Address ______________________________________________________________________ Phone ________________ Fax __________________ E-Mail___________________________ State License No ___________ 2. LEAD DESIGN PROFESSIONAL ______________________________________________ Name License # Phone Designer/Architectural _____________________________ ______________ ______________ Civil___________________________________________ ______________ ______________ Electrical _______________________________________ ______________ ______________ Fire Alarm ______________________________________ ______________ ______________ Plumbing ______________________________________ ______________ ______________ Mechanical ____________________________________________________________________ Sprinkler-Standpipe ______________________________________________________________ Structural ______________________________________ ______________ ______________ Letter of Supervision Provided □ Yes □ No. 5 City of Williston Commercial Site Plan Review Checklist 3. GENERAL CODE DATA 3.1 Building and Fire Codes used in design 3.2 Construction Description □ New Construction □ Alteration □ Renovation (Existing Bldg.) □ Addition □ Tenant Build-out Scope of Work: 3.2.1 Existing Buildings □ □ □ Yes □ No. Will the building will remain in operation during construction? Yes No. If yes add provisions for rigid safety barriers and dust barriers to protect the public during construction in accordance with the applicable provisions of IBC Chapter 33. Yellow safety tape is not an acceptable means of protection. 3.2.2 Renovations Is the work in this building or space a change of occupancy? 3.2.3 Historic Buildings Is this building is a Historic Building? 3.2.4 □ Yes □ No. Compliance Alternatives-Section 3412 Provide building evaluations when existing building does not meet current codes and renovations will not meet all requirements of current building code. Provide evaluation of existing building and a second evaluation reflecting those design features chosen by the Architect/Engineer to give the building a positive score for fire safety, means of egress, and general safety. Call t h e P l a n s E x a m i n e r if you are not sure whether evaluation is required or not. Include summary sheet (Table 3412.7) on drawings including applicable calculations. 6 City of Williston Commercial Site Plan Review Checklist 4. BUILDING DATA Construction Type □ IIIA Mixed Construction Sprinklers System Type Standpipes □ IA □ IIIB □ IB □ IV □ IIA □ VA □ Yes □ No. Types □ Yes □ No. □ Partial □ 13 □ 13R □ 13D □ Yes □ No. □ Wet□ Dry Class □ Combined Building Height Mezzanine: High Rise Atrium Basement 5. □ □ □ □ □ □ Feet □ Yes □ Yes □ Yes □ Yes Number of Stories Unlimited per □ No. □ No. □ No. □ No. OCCUPANCY CLASSIFICATION Assembly 303 □ A-1 □ A-2 □ A-3 □ A-4 □ A-5 Business 304 Education 305 Factory Industrial 306 High- Hazard 307 Institutional 308 I-3 Use Condition □ □ □ □ □ □ IIB □ VB □ F-1 □ F-2 □ H-1 □ H-2 □ H-3 □ H-4 □ H-5 □ I-1 □ I-2□ I-3 □ I-4 □1 □2 □3 □4 □5 Mercantile 309 Residential 310 Storage 311 □ R-1 □ R-2 □ S-1 □ S-2 □ R-3 □ R-4 □ High-piled Utility and Miscellaneous 312 Parking Garage 406.2 □ Open 406.3 □ Enclosed 406.4 □ Repair 406.6 7 City of Williston Commercial Site Plan Review Checklist 5.1 □ □ □ □ □ 5.2 Special Occupancy S-2 Enclosed Parking Garage w/ S-2 open parking above Unlimited height for B, M and R □ R-2 Type III A Parking Beneath R □ R-2 Type II A Open parking beneath A, I, B, M and R S-2 enclosed parking with A, B, M or R above Mixed Occupancy □ Yes □ No. Separation Hr Exception Identify whether you are using the provisions of Non-separated uses or Separated uses by placing an “x” below by your design choice. □ Non-Separated Mixed Occupancy (302.3.2 Exception) The required type of construction for the building shall be determined by applying the Height and area limitations for each of the applicable occupancies to the entire building. The most restrictive type of construction, so determined, shall apply to the entire building. □ Separated Mixed Occupancy (302.3.3) Each portion of the building shall be individually classified as to use and shall be completely separated from adjacent areas by fire barrier walls or horizontal assemblies or both having a fire-resistance rating determined in accordance with Table 302.3.3 for the uses being separated. For each story, the area of the occupancy shall be such that the sum of the ratios of the actual floor area of each use divided by the allowable floor area for each use shall not exceed 1. □ Incidental Use Areas (302.1.1) Actual Area of Occupancy A + Actual Area of Occupancy B Allowable Area of Occupancy A + Allowable Area of Occupancy B ≤ 1 6. 6.1 ALLOWABLE AREA AND HEIGHT - TABLE 503 Allowable Area Allowable area Sq. Ft Actual area Sq. Ft Attach area increase calculations per Section 506, if applicable. For unlimited areas, provide applicable paragraph number in Section 507. 6.2 Allowable Height Allowable height Ft 8 City of Williston Commercial Site Plan Review Checklist Allowable no. of stories Actual building height Ft Actual no. of stories 7. OCCUPANT LOAD Occupant Load /floor = persons Note: Include occupant load calculations for the following types of projects; institutional, assembly, educational, multistory projects, large complex projects, and mixed occupancies. 8. 8.1 FIRE PROTECTION REQUIREMENTS Table 601 Building Element Required Rating UL Number* ______________ _____________ Exterior ______________ _________________ Interior ______________ _________________ Exterior ______________ _________________ Interior ______________ _________________ ______________ _________________ ______________ _________________ Structural frame Including columns, girders, trusses Bearing Walls Non-bearing walls and partitions Floor Construction (Including supporting beams and joists) Roof construction (Including supporting beams and joists) 9 City of Williston Commercial Site Plan Review Checklist 8.2 Other Rated Elements Element Required UL Hourly Rating*UL Number* Interior Walls ........................... Bearing ................................... Non-bearing ........................... Ceiling-Floors.......................... Beams .................................... Columns ................................. Ceiling-Roofs .......................... Shafts-Exit .............................. Shafts-Other ........................... Corridor Separation ............... Occupancy Separation ........... Party/Fire Wall Separation: ................ Smoke Barrier Separation: ................ Tenant Separations: .............. * Or other approved agencies FOOTNOTES 1. All fire rated walls shall be identified on plans by hatching, shading, etc.; show legend. 2. Identify code section when using any special exceptions, etc. 8.3 Draft stopping Draft stopping in floors (717.3) □ Yes □ Yes □ No. Draft stopping in attics (717.4) 8.3.1 □ No. Distance to Property Line from Exterior Wall (Table 602) (Site Plan/Reference Plan required) Fire Separation Distance Ft Fire Resistance Rating Hrs 8.4 Life Safety Systems 1006 Emergency Lighting: 1011 Exit Signs: □ Yes □ Yes □ No. □ No. 10 City of Williston Commercial Site Plan Review Checklist 907 Fire Alarm: 907 Smoke Detection Systems: 1008.1.10 Panic Hardware: 9. 9.1 □ Yes □ Yes □ Yes □ No. □ No. □ No. EXIT REQUIREMENTS Exit Access (1014 & 1021) No. of exits required No. of exits furnished 9.2 Means of egress width (1005.1) Units of exit required inches Units of exit furnished inches Stair width units required inches Stair width units provided inches 9.3 Diagonal Rule Meets 1015.2.1 9.4 □ Yes □ No. Travel Distance (Tables 1016.1 & 1021.2) Allowable Travel Distance Ft Actual Travel Distance (Maximum) Ft 9.5 Spaces with one means of egress (IBC 1021.2) For buildings with one means of egress, I have checked the occupant load and the common path of travel against the requirements IBC Table 1021.2. □ Yes □ No. 10. LIFE SAFETY PLAN Provided □ Yes □ No. (If yes, Drawing No.) 11. ACCESSIBILITY (Chapter 11) □ □ Design conforms to ANSI Standard 117.1. Yes No. If no, explain condition that will not allow building to be accessible. 11 City of Williston Commercial Site Plan Review Checklist 12. DESIGN LOADS Classification of Building - Category/Use Group ___________ (I, II, III, IV) Live Load Roof PSF Roof Snow PSF Attic PSF Mezzanine PSF Floor PSF Ground Snow PSF Wind Load: Basic speed MPH (3-second gust, ASCE-7-98 Edition) Exposure Importance Factor Internal Pressure Coefficient Components & Cladding Building will be designed as Allowable soil bearing □ Enclosed Building □ Unenclosed Building pounds / sq. ft. □ Yes □ No. Seismic Design Load Controls □ Yes Soil Report Earthquake Design □ No. If seismic design controls, furnish data required in 1603.1.5. 13. SPECIAL DETAILED REQUIREMENTS I have reviewed the special detail requirements in Chapter 4 as indicated below and incorporated the provisions into my design. REQUIREMENT 402 403 404 405 APPLICABLE(YES or N/A) □ Yes High-Rise buildings ............................................................................... □ Yes Atriums ................................................................................................. □ Yes Under Ground buildings ........................................................................ □ Yes Covered Mall building............................................................................ □ N/A □ N/A □ N/A □ N/A 12 City of Williston Commercial Site Plan Review Checklist 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 □ Yes Group I-2 .............................................................................................. □ Yes Group I-3 .............................................................................................. □ Yes Motion Picture Projection Rooms .......................................................... □ Yes Stages & Platforms ................................................................................ □ Yes Special Amusement Buildings ............................................................... □ Yes Aircraft Related Occupancies ................................................................ □ Yes Combustible Storage ............................................................................. □ Yes Hazardous Materials ............................................................................. □ Yes Groups H-1, H-2, H-3, H-4, & H-5......................................................... □ Yes Application of flammable finishes .......................................................... □ Yes Drying Rooms ....................................................................................... □ Yes Organic Coatings .................................................................................. □ Yes Live/Work Units………………………………………………………..□ Yes Groups I-1, R-1, R-2, R-3…………………………………………….□ Yes Hydrogen Cutoff Rooms……………………………………………...□ Yes Ambulatory Health Care Facilities…………………………………...□ Yes Storm Shelters…………………………………………………………□ Yes Motor-vehicle Related Occupancies ...................................................... □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A □ N/A 14. SPECIAL INSPECTIONS I have reviewed the requirements of IBC Section 1704 on Special Inspections and will perform the applicable required inspections as part of my responsibilities acknowledged under my letter of supervision. □ Yes □ No. 15. SAFETY GLAZING FOR HAZARDOUS LOCATION I have identified on drawings where tempered glass is required in hazardous locations. (2406.2) □ Yes □ No. 13 City of Williston Commercial Site Plan Review Checklist 16. PREFABRICATED METAL BUILDINGS Requirements for metal building erection drawings included on drawings. □ Yes □ No. 17. PRE-ENGINEERED TRUSSES Live Loads shown Wind Loads shown Certification from manufacturer (Sealed) 14 City of Williston Commercial Site Plan Review Checklist