Page |1 Local Social Services (LSS): Energy Analysis (DRAFT) Initial Contact Date: Sept 25th 2014 Report Submission Date: Dec 8th 2014 Professor: Mike Erdman Name Kyle Brennan Joseph Giordiano Ali Al Moulah Wesley Schwarz TA: Heather Bernstein Phone Number (215) 847-0901 (610) 737-8949 (646) 671-1383 (484) 753-1567 Email krb5256@psu.edu jdg5403@psu.edu aoa5554@psu.edu wms5099@psu.edu Abstract: The Local Social Services team is motivated to aid and help out a local non-profit organization in order to benefit the State College community as a whole. The team decided that the aiding Alpha Fire Company, who match up with our vision and values, was an important project because they are a vital service to State College. Our focus is to reduce their energy cost expenditures by increasing system efficiencies. We came to the conclusion that the most effective way to address this issue is by upgrading their lighting systems to a more modern and energy efficient technology such as replacement LED lights and fixtures. Page |2 Table of Contents: Page # Abstract (1) Foreword (3) Introduction (4) Experimental Procedure (5) Results and Discussion (6) Conclusions and Recommendations (7) Acknowledgments and References (7) Appendix (8) Page |3 Foreword: Why was this report written? This report was written to document the project of the Local Social Services team of ENGR 408 & 493 as well as to provide the Alpha Fire Company a plan with a good solution to tackle their problem. This document and our research into the topic highlight how Alpha Fire’s energy burden can be mitigated by improving their lighting systems. Who authorized this project? Mike Erdman, professor of ENGR 408 and ENGR 493, gave us the initiative to form this team and search for a problem to solve in the local community. After meeting with Alpha Fire Company staff, Tony Berrena, Second assistant chief, authorized this project and acted as a mentor and liaison between the team and Alpha Fire. How should this report be used? The report can be used to help the Alpha Fire Company distinguish where best to address their lighting system’s inefficiencies. In addition, this document allows the fire company to move forward with being more energy conscious - saving money in their current budget to allow for its future use in other important areas and improvements. Page |4 Introduction: Much of Alpha Fire Company’s fire station and systems are outdated, having been built in the ‘70s. Because of the building’s age, it lacks proper and effective insulation on many of its outer walls, which, when combined with State College’s harsh winters, are a substantial heat-loss factor, wasting energy and driving up their energy consumption. On top of that, the HVAC ventilation and roof units are over 30 years old while their recommended life-span is a mere 11 years. Additionally, their fluorescent lighting systems are pervasive throughout the station, from the heavily-lit engine bay to the upstairs conference room and living quarters. These light fixtures need to be replaced with more efficient LED lights in order to cut peak-energy demand and save Alpha Fire Company thousands of dollars annually. The LSS team focused on the energy issues associated with Alpha Fire’s lighting systems because of the high return on investment as well as the speed by which our plan can be adopted and implemented. Resurfacing the inner walls of the building to address the insulation issue or replacing the ventilation ducts and multiple roof HVAC units pose as expensive long-term projects for Alpha Fire Company which would take several years to put into motion. Our team realized that replacing the current lighting systems with high-efficiency LEDs is a project that can be carried out within the year and start saving them money immediately. Page |5 Procedure: After examining local social services and choosing Alpha Fire Company, we conducted a building evaluation to determine the extent of the structural inefficiencies and other needs. The team meet with Tony Berrena who is in charge of the station’s systems and its renovation plans. He has extensive knowledge of Alpha Fire’s existing inadequacies and their plans to address these issues, such as: adding building insulation, implementing a heat exchange system, replacing HVAC roof units, fixing the water heater, installing energy efficient windows, and switching to LED lighting. Mr. Berrena provided us with a digital copy of the building’s floor plan and energy (gas/electricity) consumption bill. With this data we were able to identify the number of light fixtures and bulbs that should be replaced which allows us to calculate the initial replacement cost and long-term energy savings between fluorescent and LED lights. After several more meetings and visits to the station we were able to determine the current power usage, its price, and the number of light fixtures in the building. This allowed us to calculate the power consumption of their current lighting system and by using data gathered on LED power consumption for each different unit size. By comparing the power consumption per unit of LEDs and Fluorescent bulbs, and using Alpha Fire Company's current power billing rates, we were able to calculate their return on investment and how long the savings would pay for the initial cost of materials. (See Appendix A). Page |6 Results and discussion: Comparing the current fluorescent fixtures to the new LED system, we found that it saves them approximately thirteen watts of power per tube (Appendix B). This power savings alone should allow them to gross $1,733 after only two years and $10,708 in 5 years (Appendix A). This only takes into account the consistent power consumption of twelve hours of daily use. However, because they are charged on an initial surge basis as well, well it is likely that their savings will be a lot higher than estimated. To clarify, a surge charge is an added charge on top of overall consumption that takes into account the maximum amount of power being drawn at one time. Since the replacement bulbs use close to half the original power and draw far less power upon start up, we expect this number to be significantly greater than estimated. Also when refitting a large scale system like this it is likely that they will contract a bulk deal for the necessary lights and fixtures, instead of the unit price that we based our calculations on. While there are still other systems that are on schedule for upgrade, the data and plans we created should accelerate the installment process. We expect the project to be passed by the township and up for bid within the next three months. We did encounter several obstacles in trying to complete this construction plan. The electrical and construction plans that we were giving to work with were not up to date, leaving us to recreate a new document for future records. Being that everyone who worked there, including the senior staff, were only there as part-time volunteers, we often faced availability problems when trying to meet to discuss certain issues. Page |7 Conclusions and Recommendations: Our recommendation for Alpha Fire Company follows a consistent room-by-room replacement plan in order to spread out the initial replacement costs over several months if that is indeed necessary due to budget restrictions. Yet, if it is possible to complete the process all at once it could benefit from bulk purchases and follow the energy savings model we calculated (Appendix A). The most important area of the station to focus light fixture and bulb replacements is the apparatus bay (also called the engine room) because of it accounts for nearly 2/3’s of the fluorescent bulbs our plan seeks to remove. Also, by replacing the apparatus bay first, which would remove a large factor in the amount of energy surge they experience, lowing their billed rate in the following cycle. The next most important area to address would be the upstairs conference room which has the next largest concentration of light fixtures. Another way Alpha Fire Company would benefit and save energy is installing new occupancy sensors that would ensure lights are only turned on when the rooms are in use, reducing overhead costs. Acknowledgements and References: We would like to first and foremost thank professor Mike Erdmann for the guidance and the keeping us on track with the weekly reports, as well as Heather for all her help throughout the semester and answering our questions in every meeting. Also, a very special thank you to Tony Berrena, the 2nd assistant chief at the Alpha Fire Company for being patient, understanding and helpful throughout the semester. Page |8 Appendix: Table A: Table B: (https://www.1000bulbs.com/product/113414/FOREST-MT8W09.html#) (Table B)