08 14 16 - FLUSH WOOD DOORS Revised 2014

advertisement
Nortrax
190 David Manchester Road, Ottawa
16 May 2014
Section 08 14 16
FLUSH WOOD DOORS
Page 1
Part 1
General
1.1
Wood doors, both rated and non-rated are for the office area as noted on the door
schedule
1.2
RELATED SECTIONS
1.3
.1
Section 06 20 00 - Finish Carpentry.
.2
.
.3
Section 06 40 00 - Architectural Woodwork
.4
Section 08 71 00 - Door Hardware.
.5
Section 08 80 00 – Glazing
Section 08 11 00 - Metal Doors and Frames.
REFERENCES
.1
Architectural Woodwork Standards 1st Edition 2009
.2
ANSI/WDMA I.S. 1A-11 Industry Standard for Architectural Wood Flush Doors
.3
CAN/ULC S-104-10 Standard Method for Fire Tests of Door Assemblies
.4
NFPA 80-13 Standard for Fire Doors and Other Opening Protectives
.5
NFPA 252-12 Standard Method of Fire Tests of Door Assemblies
.6
ITS/Warnock Hersey Mark for Fire Door Test Certification
.7
ASTM E90-09 Standard Test Method for Laboratory Measurement of Airborne
Sound Transmission Loss of Building Partitions and Elements
.8
ASTM E413 - 10 Classification for Rating Sound Insulation.
.9
FSC – Forest Stewardship Council Standard for Chain of Custody Certification,
FSC-STD-40-004, V2-1.
.10
LEED® Canada Rating System
.11
UL 752-11 - Standard for Bullet-Resisting Equipment.
.12
NIJ (National Institute for Justice) 0101.06 - Ballistic Resistance of Body Armor.
Nortrax
190 David Manchester Road, Ottawa
16 May 2014
1.4
1.5
1.6
1.7
Section 08 14 16
FLUSH WOOD DOORS
Page 2
SHOP DRAWINGS
.1
Submit shop drawings in pdf format.
.2
Shop Drawings: illustrate door opening information such as location, size types,
construction, swings, undercuts, special bevelling, hardware location and
preparation requirements, blocking for hardware in mineral core doors, fire
ratings, lite cut-outs, factory finish, glass, and other pertinent data.
.3
Product Data: Indicate door core materials, thickness, construction, veneer
species.
.1
Indicate manufacturer’s full lifetime warranty.
.2
Indicate glass size, type and thickness for factory glazed doors.
SAMPLES
.1
If so requested; provide door construction samples with door faces, edges, and
core representative of the specified door types.
.2
Provide pre-finished veneer sample to illustrate the color of the specified door
face materials.
QUALITY ASSURANCE
.1
Perform work to Premium Grade in accordance with the Grade requirements
specified in the Architectural Woodwork Standards 1st Edition 2009, or as herein
otherwise specified.
.2
Manufacturer specializing in products herein specified with a minimum of five
years documented experience.
.3
Provide fire-rated wood doors in compliance with NFPA 80.
.4
Provide fire-rated wood doors with ULC or ITS/Warnock Hersey label.
DELIVERY, STORAGE, AND HANDLING
.1
Deliver, store, protect and handle products in compliance with the Architectural
Woodwork Standards; Section 2 Care & Storage, and manufacturer’s care and
handling instructions.
.2
Deliver materials only when the project is ready for installation and the general
contractor has provided a clean storage area.
Nortrax
190 David Manchester Road, Ottawa
16 May 2014
1.8
Section 08 14 16
FLUSH WOOD DOORS
Page 3
.3
Accept doors on site in manufacturer’s standard packaging. Inspect for damage.
.4
Protect all doors from exposure to natural and artificial light after delivery.
WARRANTY
.1
Provide manufacturer’s standard lifetime warranty for “Full Life of Original
Installation”, including hanging and finishing if doors do not comply with
warranty tolerance standards.
.2
Include coverage for delamination, warping, bow, cup and telegraphing of core
construction beyond warranty tolerances.
PART 2 PRODUCTS
2.1
MANUFACTURER
.1
2.2
Manufacturer:
.1
Lambton Doors or approved equal
COMPONENTS
.1
.2
For both rated and non-rated flush wood doors:
.1
Manufacture doors to ANSI/WDMA I.S. 1A-11 Heavy Duty performance
level.
.2
Faces of wood veneered doors intended for transparent finish: AA Grade,
Center Balance.
.6
Provide UF Free composite crossband. Wood crossband is not permitted.
.7
Adhesives: AWS Type I.
Additionally; for Non-Rated Wood Doors
.1
Core for non-rated doors: UF Free Particleboard
.2
Stiles for non-rated doors: structural composite lumber laminated to
hardwood.
.3
Top and bottom rails for non-rated doors: structural composite lumber.
Nortrax
190 David Manchester Road, Ottawa
16 May 2014
.3
2.3
Additionally; Fire-rated Wood Doors
.1
Core for 20-minute fire-rated doors: UF Free Particleboard
.2
Core for 45 minute fire-rated doors: Mineral Core, Structural Composite
Lumber Core or Agrifiber Core.
.3
Core for 60 minute fire-rated doors and 90-minute fire rated doors:
Mineral Core.
.4
Stiles and rails for fire-rated wood doors: manufacturer’s standard,
conforming to the requirements of the manufacturer’s labelling agency.
ACCESSORIES
.1
2.4
Section 08 14 16
FLUSH WOOD DOORS
Page 4
There are no accessories.
FABRICATION
.1
Doors shall meet the requirements of ANSI/WDMA I.S. 1A-11 Heavy Duty
performance level
.2
Doors shall be 5 ply construction.
.3
Fully bond stiles and rails to core and abrasive plane assembled unit prior to
lamination of faces.
.4
Assemble doors using AWS Type 1 adhesive that does not contain added ureaformaldehyde resins.
.5
Edges for veneered doors: AWS Type A, constructed with 25mm of structural
lumber laminated to 11mm of hardwood of the same species as face veneer.
AWS Type B, wood veneer edges are not permitted.
.6
Rails for doors minimum 36mm of structural composite lumber.
.7
Edges for veneered doors minimum 25mm structural composite lumber
laminated to 11mm of hardwood of the same species as face veneer Wood veneer
edges are not permitted.
.8
Construct fire-rated doors to the requirements of all applicable labelling agencies.
.9
Provide blocking on all non-rated and fire-rated doors, as required for hardware to
prevent the need for through-bolting.
Nortrax
190 David Manchester Road, Ottawa
16 May 2014
2.5
Section 08 14 16
FLUSH WOOD DOORS
Page 5
.10
Factory drill pilot holes for hinges.
.11
Bevel lock and hinge stile to Architectural Woodwork Standard 1st Edition 2009,
3 degree bevel.
.12
Factory install non-rated and fire rated glass and glazing.
FINISHES
.1
Factory Finishing: All products provided in this Section shall be factory finished
using Architectural Woodwork Standards 1st Edition 2009, System 9 UV Curable
System.
.1
Factory stain: Water-based stain with ultraviolet (UV) curable
polyurethane.
.2
Factory seal top and bottom of doors.
.3
Provide Touch-up Kit for field touch-ups.
PART 3 EXECUTION
3.1
3.2
EXAMINATION
.1
Verify that opening sizes and tolerances are acceptable and ready to receive this
work.
.2
Do not install doors in frame openings that are not plumb or are out of tolerance
for size or alignment.
INSTALLATION
.1
Install non-rated and fire-rated doors in accordance with NFPA 80,
manufacturer’s instructions and to ITS/Warnock Hersey requirements.
.2
Install factory finished doors just prior to substantial completion.
.3
Allow a fitting clearance of 3mm.
.4
Trim non-rated door widths as required by cutting equally on both edges. Reseal
and refinish all cut or planed surfaces immediately to match factory finish.
.5
Trim door height by cutting bottom edges to a maximum 19mm.
Nortrax
190 David Manchester Road, Ottawa
16 May 2014
3.2
Section 08 14 16
FLUSH WOOD DOORS
Page 6
.6
Trim fire door heights at bottom edge only in accordance with fire rating
requirements.
.7
Do not trim fire rated door widths.
.8
Factory drill pilot holes.
.9
Coordinate installation of doors with installation of frames and hardware.
.10
Install door louvers and light kits plumb and level.
.11
Adjust doors for smooth and balanced door movement and operation.
TOLERANCES
.1
Conform to the Architectural Woodwork Standards 1st Edition 2009 standards and
testing methods for warp, cup, bow, and telegraphing.