SECTION 09 80 00 ROOM ACOUSTIC TREATMENTS Display

SECTION 09 80 00

ROOM ACOUSTIC TREATMENTS

Display hidden notes to specifier. (Don't know how? Click Here )

Copyright 2004 - 2014 ARCAT, Inc. - All rights reserved

PART 1 GENERAL

1.1 SECTION INCLUDES

A. Floor sound treatment.

B. Ceiling sound treatment.

C. Wall sound treatment.

D. Duct and pipe lagging barrier.

E. Equipment isolation.

F. Accessories.

1.2 RELATED SECTIONS

A. Section 09 90 00 - Painting and Coating.

B. Section 09 51 23 - Acoustical Tile Ceilings.

1.3 REFERENCES

A. ASTM C423 - Standard Test Method for Sound Absorption and Sound Absorption

Coefficients by the Reverberation Room Method.

B. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials.

C. ASTM E795 - Standard Practices for Mounting Test Specimens During Sound Absorption

Tests.

1.4 SUBMITTALS

A. Submit under provisions of Section 01 30 00.

B. Product Data: Manufacturer's data sheets on each product to be used, including:

1. Preparation instructions and recommendations.

2. Storage and handling requirements and recommendations.

3. Installation methods.

C. Shop Drawings:

1. Submit shop drawings showing layout, edge profiles and baffle / cloud components, including suspension method, accessories, finish colors and textures.

09 80 00-1

D. Selection Samples: For each finish product specified, two complete sets of color chips representing manufacturer's full range of available colors and patterns.

E. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.

1.5 QUALITY ASSURANCE

A. Product Qualifications: Products shall meet the following criteria.

1. Surface Burning Characteristics (ASTM E84): a. Flamespread: 25, maximum. b. Smoke Developed: 450, maximum.

B. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

1. Finish areas designated by Architect.

2. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.

3. Refinish mock-up area as required to produce acceptable work.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Store products in manufacturer's unopened packaging until ready for installation.

B. Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.

1.7 PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's absolute limits.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A. Acceptable Manufacturer: Kinetics Noise Control Inc., which is located at: 6300 Irelan Place

P. O. Box 655; Dublin, OH 43017-0655; Toll Free Tel: 800-959-1164; Tel: 614-889-0480;

Fax: 614-889-0540; Email: request info (sales@kineticsnoise.com) ;

Web: www.kineticsnoise.com

B. Substitutions: Not permitted.

C. Requests for substitutions will be considered in accordance with provisions of Section 01 60

00.

2.2 FLOOR SOUND TREATMENT

A. The isolation system shall have a minimum IIC rating of ____, and an STC rating of

_____and shall have been tested by a nationally recognized independent Acoustical

Laboratory. System shall meet Class 1 requirements for flame spread and smoke developed per ASTM E-84 testing.

B. Underlayments:

1. Kinetics SR Floorboard: 5/8 inch (16 mm) thick composite of high density molded glass fibers separated by a rigid phenolic-treated honeycomb core.

2. Kinetics Soundmatt: 5/16 inch (8 mm) thick underlayment comprised of

09 80 00-2

precompressed molded glass fibers .

2.3 CEILING SOUND TREATMENT

A. Diffuser and Reflector Panels:

1. Kinetics Geometric: a. Description: Thermo-molded PVC shapes. b. Sound Absorption (ASTM C423): Noise Reduction Coefficient shall be no greater than .10 for A Mounting and E400 (lay-in ceiling) Mounting. c. Shape: Radiused. d. Shape: Offset Pyramidal. e. Size: 24 inches by 24 inches by 5.25 inches (610 by 610 by 133 mm) radiused. f. Size: 24 inches by 24 inches by 6.75 inches (610 by 610 by 171 mm) offset pyramidal. g. Size: 24 inches by 48 inches by 5.25 inches (610 by 1220 by 133 mm) radiused. h. Size: 24 inches by 48 inches by 6.75 inches (610 by 1220 by 171 mm) offset pyramidal. i. j.

Size: 36 inches by 36 inches by 7.00 inches (915 by 915 by 178 mm) radiused.

Size: 36 inches by 48 inches by 9.75 inches (915 by 1220 by 248 mm) radiused. k. Size: 36 inches by 72 inches by 9.75 inches (915 by 1830 by 248 mm) l. radiused.

Size: 48 inches by 48 inches by 9.75 inches (1220 by 1220 by 248 mm) radiused. m. Size: 48 inches by 72 inches by 12.75 inches (1220 by 1220 by 324 mm) offset pyramidal. n. Size: 48 inches by 72 inches by 9.75 inches (1220 by 1830 by 248 mm) radiused. o. Finish: Standard white. p. Finish: Suede texture. q. Finish: Fabric wrapped. r. Finish: Painted finish. s. Mounting: Lay in ceiling T grid t. Mounting: Suspended from open structure in a cloud formation u. Mounting: Z-clip mounting flush to wall surface.

2. Kinetics Ovation Sound Reflector Panel: a. Description: Plywood core faced on front and back with finished surfaces. b. Sound Reflectivity: Noise Reduction Coefficient per ASTM C423 no greater than 0.00. Sound Absorption Coefficients must be no greater than .01 for all

1/3 octave band frequencies in the 100 Hz to 1000 Hz range. c. Size: As shown on drawings with a maximum size of 120 inches by 240 inches

(305 by 610 cm).Refer to drawings for size, curvature, finish color and attachment details. d. Finish: Colored fiber glass gel coat e. Finish: Plastic laminate. f. Finish: Hardwood veneer. g. Suspension Attachment and Flexing system: 1/8 inch (3mm) steel angle attachment painted black and 1/4 inch (6mm) diameter zinc-plated tensioning rods mounted on the top (unexposed) side of the reflector panel. Panels shall be flexed to a radius before installation.

B. Acoustical Baffles:

1. Refer to drawings for finish, size and attachment.

2. Kinetics BAP: a. Description: Fabric covering over a 1-1/2 inch (38 mm) rigid PVC frame and

09 80 00-3

125Hz

0.26 core. b. Sound Absorption (ASTM C423) : Sabins per square foot of baffle minimum-

250Hz 500Hz 1000Hz 2000Hz 4000Hz

0.62 1.23 1.81 1.9 1.95

Testing of baffles in a typical vertically suspended layout.

125Hz c. Thickness: shall be 1-3/4 inches (44 mm). d. Size: As indicated on drawings up to a maximum 48 inches (1219 mm) by 96 inches (2438 mm) baffle. e. Core: 1-1/2 inches (38 mm) thick, 3 pcf (48 kg/cm) density fiberglass. f. Edge Detail: Rounded pencil. g. Facing: 100% Polyester fabric, FR701 style 2100 by Guilford of Maine. h. Facing: Factory approved customer selected fabric. i. Mounting: Suspension wire, cable, or chain attached to the Zinc plated steel eye screws at the top of each baffle.

3. Kinetics KSB: Fabric covering edge sewn over a 1-1/2 inch (38 mm) absorptive core material.

4. Kinetics KB-803: Vinyl cover over an absorptive core material. a. Thickness: shall be 1-1/2 inches (38 mm). b. Sound Absorption (ASTM C423): Sabins per square foot of baffle minimum-

250Hz 500Hz 1000Hz 2000Hz 4000Hz

.25 .74 1.49 1.80 1.53 .98

Testing of baffles in a typical vertically suspended layout.

125Hz c. Size: As indicated on drawings up to a maximum 48 inch (1219 mm) by 96 inch

(2438 mm) baffle. d. Core: 1-1/2 inches (38 mm) thick, 3 pcf (48 kg/cm) density fiberglass. e. Facing: Baffles shall be heat sealed in a fire retardant 3 mil (.08 mm) minimum and 4 mil (.10 mm) maximum vinyl film. f. Color: As selected from panel manufacturer's standard vinyl colors. g. Mounting: Suspension wire, cable, or other approved hanging mechanism attached to plated brass eyelets which are part of the baffle.

5. Kinetics Wave: a. Description: Sailcloth facing over 2 inches (51 mm) thick fiber glass blanket. b. Sound Absorption (ASTM C423) : Sabins per square foot of baffle to meet the following minimums in each frequency band

250Hz 500Hz 1000Hz 2000Hz

1.25 .46 .80 1.26

Testing of baffles in a typical horizontally draped layout.

1.47 c. Size: As shown in drawings up to a maximum 48 inches (1219 mm) wide and

360 inches (9144) long. d. Core shall be 2 inches (51 mm) thick fiberglass, 1.5 pcf (24 kg/cm) density. e. Facing: 1.5 ounce (43 g) sewn ripstop sailcloth. f. Facing: Webcore Vinyl. g. All edges face wrapped and stitched. Suspension eyelets across each 48 inches (1219 mm) side as required. h. Mounting: Wire, cable, or other approved hanging mechanism attached to brass plated eyelets.

6. Kinetics Applique Cloud:

09 80 00-4

a. Description: Fabric wrapped aluminum frame with 3 pcf (48 kg/cm) fiberglass core. b. Sound Absorption (ASTM C423): Noise Reduction Coefficient of 0.85, minimum, for a 1 1/2 inch (38 mm) panel. c. Thickness: 1 inch (25 mm) core, 1-1/2 inch (38 mm) overall. d. Thickness: 2 inch (51 mm) core, 2-1/2 inches (64 mm) overall. e. Fabric: Refer to drawings and interior finish schedule. f. Size: As indicated on the drawings up to a maximum 48 inch (1219 mm) by 96 inch (2438 mm) cloud panel. g. Edge Detail: Pencil. h. Mounting: Suspend cloud panels using wire, cable, or other acceptable mechanism attached to clips on the panel frame..

7. Kinetics Hardside Baffles: a. Sound Absorption (ASTM C423): Noise Reduction Coefficient as follows:

1) 1 inch (25.4 mm) Panel: 0.80, minimum

2) 2 inches (51 mm) Panel: 1.00, minimum

3) 4 inches (102 mm) Panel: 1.10, minimum a) Baffle panels tested with an A mounting (flush) to hard surface. b. Thickness: 1inch (25.4 mm). c. Thickness: 2 inches (51 mm). d. Thickness: 4 inches (102). e. Size: As indicated on the drawings up to a maximum 48 inch (1219 mm) x 120 inch (3048 mm) baffle. f. Core: 2 layers of 5 to 7 pcf (80 to 112 kg/cm) density fiberglass bonded for the required thickness. g. Edge Detail: Square hardened with non-resin, Class A hardening solution. h. Edge Detail: Round hardened with non-resin, Class A hardening solution. i. Edge Detail: Mitered hardened with non-resin, Class A hardening solution. j. Edge Detail: Beveled hardened with non-resin, Class A hardening solution. k. Edge Detail: Pencil hardened with non-resin, Class A hardening solution. l. Facing: 100% polyester fabric, FR 701 Style 2100 by Guilford of Maine m. Facing: Factory approved customer selected fabric. n. Mounting: Suspension wire, cable, or chain attached to the Zinc plated steel eye screws at the top of each baffle.

8. Kinetics Hardside Cloud: a. Thickness: 1 inch (25.4 mm). b. Thickness: 2 inch (51mm). c. Sound Absorption (ASTM C423): Noise Reduction Coefficient as follows:

1) 1 inch (25.4 mm) Panel: 0.80, minimum.

2) 2 inches (51 mm) Panel: 1.00, minimum. a) Cloud panels tested with an A mounting (flush) to hard surface. d. Size as indicated on the drawings up to a maximum 48 inches (1219 mm) by

120 inches (3048 mm) cloud panel. e. Core: 1 inch (25 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density. f. Core: 2 inches (51mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density. g. Edge Detail: [Square] [Round] [Mitered] [Beveled] [Pencil] edges hardened with a non-resin, Class A hardening solution. h. Facing: 100% polyester fabric, FR 701 Style 2100 by Guilford of Maine. i. j.

Facing: Factory approved customer selected fabric.

Color: As selected from panel manufacturer's stocked range of colors. k. Color: As selected from fabric manufacturer's full range of colors]. l. Mounting: Suspend cloud panels using wire, cable or other acceptable mechanism attached to eye screws on the back unfaced side of the cloud panels.

C. Acoustical Ceiling Panels:

09 80 00-5

1. Panels shall be designed for use with 9/16 inch (14 mm) or 15/16 inch (24 mm) wide suspended ceiling grid.

2. Kinetics Embassy: a. Description: Panels shall be 1.75 inches (45 mm) thick with a .50 inch (13 mm) reveal, fabric wrapped aluminum framed with fiberglass core. Panels shall include a 1.80 lb/sf mass layer and a 1 inch (51 mm) thick 5 to 7 pcf fiberglass absorber assembled in an aluminum frame. b. Acoustical Performance:

1) Per ASTM C423: Noise Reduction Coefficient of .80 minimum.

2) Per ASTM E413: Ceiling Attenuation Class (CAC) of 53, minimum. c. Fabric: Refer to drawings and finish schedule. d. Size: 24 inches by 24 inches (610 mm by 610 mm). e. Size: 24 inches by 48 inches (610 mm by 1220 mm).

3. Kinetics QuietTile: a. Thickness: Overall panel thickness shall be determined by the facing tile specified. Additional thickness of the Sound Deadener (damping) and mass layer bonded to the facing tile shall be 9/16 inches (14 mm). b. Sizes: 24 inches by 24 inches (610 by 610 mm) c. Sizes: 24 inches by 48 inches (610 by 1220 mm). d. Edge Detail: Based on facing tile selected by architect. e. Ceiling facing tile as selected by Architect f. Core: Class A fire rated mass layer weighing 1.80 lb/sf (8.8 kg/sm) and a 1/16 inch (2 mm) sound deadening asphaltic mastic layer bonded to the facing tile and supplied by the manufacturer. g. Acoustical Performance: Per ASTM E413: Ceiling Attenuation Class (CAC) of

50, minimum.

D. Hangers:

1. Kinetics ICW Ceiling Hanger/Wood: Spring isolated ceiling design where 1 inch (25 mm) rated spring deflection and a 10 inches (254 mm) airspace is required. Supports

1-1/2 inches by 1/2 inch (38 mm by 13 mm) cold-rolled channel which in turn supports the drywall furring channel.

2. Kinetics ICC Ceiling Hanger/Concrete: Spring isolated ceiling design where 1 inch (25 mm) rated spring deflection and a 10 inches (254 mm) airspace is required. Supports

1-1/2 inches by 1/2 inch (38 mm by 13 mm) cold-rolled channel which in turn supports the drywall furring channel.

3. Kinetics KSCH Ceiling Hanger: 1/2 inch (13 mm) dual deflection springs supports 1-

1/2 inches by 1/2 inch (38 mm by 13 mm) cold-rolled channel which in turn supports the drywall furring channel.

4. Kinetics KSCH Ceiling Hanger: 1 inch (25 mm) dual deflection springs supports 1-1/2 inches by 1/2 inch (38 mm by 13 mm) cold-rolled channel which in turn supports the drywall furring channel

5. Kinetics AF Ceiling Hanger: Noise stop isolator for use in wire-supported, suspended ceiling systems. 500 percent overload without failure. a. Model AF-100 load range: 20-100 pounds (9-46 kg), used for light-weight acoustical tile ceilings. b. Model AF-200 load range: 50-200 pounds (23-91 kg), used for heavy gypsum board and plaster ceilings.

E. Resilient Channel Isolator:

1. Resilient sound isolation ceiling clip. Clip accepts and holds furring channel in a resilient insert.

2. Kinetics IsoMax.

2.4 WALL SOUND TREATMENT

09 80 00-6

A. Acoustical Wall Treatment:

1. Kinetics Hardside: a. Description: Fabric wrapped molded fiberglass. b. Sound Absorption (ASTM C423): Noise Reduction Coefficient as follows:

1) 1/2 inch (12.7 mm) Panel: 0.60, minimum.

2) 1 inch (25.4 mm) Panel: 0.80, minimum.

3) 1-1/2 inch (38 mm) Panel: 0.95, minimum.

4) 2 inch (51 mm) Panel: 1.00, minimum. c. Size: Standard width to 4 feet (1219 mm) and height to 10 feet (3048 mm).

Refer to drawings for size and attachment. d. Core Thickness: 1/2 inch (12.7 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density. e. Core Thickness: 1 inch (25.4 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density. f. Core Thickness: 1 1/2 inch (38 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density. g. Core Thickness: 2 inch (51 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density. h. Core Thickness: 3 inch (76 mm)thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density. i. Core Thickness: 4 inch (102 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density. j. Edge Detail: Square, hardened with non-resin, Class A hardening solution. k. Edge Detail: Round, hardened with non-resin, Class A hardening solution. l. Edge Detail: Mitered, hardened with non-resin, Class A hardening solution. m. Edge Detail: Beveled, hardened with non-resin, Class A hardening solution. n. Edge Detail: Pencil, hardened with non-resin, Class A hardening solution. o. Fabric: Refer to drawings and interior finish schedule. p. Mechanical Mounting:

1) HS Impaling clips

2) Z-clips.

3) Edgemount clips.

4) Velcro.

5) Magnetic tape.

2. Kinetics High Impact Hardside: a. Description: Fabric wrapped molded fiberglass. b. Sound Absorption (ASTM C423): Noise Reduction Coefficient as follows:

1) 1-1/8 inch (29 mm) Panel: 1.00, minimum.

2) 2-1/8 inch (54 mm) Panel: 1.05, minimum. c. Size: Standard width to 4 feet (1219 mm) and height to 10 feet (3048 mm).

Refer to drawings for size and attachment. d. Core Thickness: 1 inch (25.4 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density, with bonded facing layer of 12 pcf (192 kg/m3), 1/8 inch (3.2 mm) thick impact resistant fiberglass. e. Core Thickness: 1 inch (25.4 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density, with bonded facing layer of 18 pcf (288 kg/cm), 1/8 inch (3.2 mm) thick impact resistant fiberglass. f. Core Thickness: 2 inches (51 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density, with bonded facing layer of 12 pcf (192 kg/cm), 1/8 inch (3.2 mm) thick impact resistant fiberglass. g. Core Thickness: 2 inches (51 mm) thick fiberglass, 5 to 7 pcf (80 to 112 kg/cm) density, with bonded facing layer of 18 pcf (288 kg/cm), 1/8 inch (3.2 mm) thick impact resistant fiberglass. h. Edge Detail: Square, hardened with non-resin, Class A hardening solution. i. Edge Detail: Round, hardened with non-resin, Class A hardening solution. j. Edge Detail: Mitered, hardened with non-resin, Class A hardening solution.

09 80 00-7

k. Edge Detail: Beveled, hardened with non-resin, Class A hardening solution. l. Edge Detail: Pencil, hardened with non-resin, Class A hardening solution. m. Fabric: Refer to drawings and interior finish schedule. n. Mechanical Mounting:

1) HS Impaling clips

2) Z-clips.

3) Edgemount clips.

4) Velcro.

5) Magnetic tape.

3. Kinetics Design Series 90: a. Description: Fabric wrapped fiberglass faced honeycomb core. b. Sound Absorption (ASTM C423): Noise Reduction Coefficient as follows:

1) Mounted over Solid Substrate: 0.70, minimum.

2) Mounted with 3/4 inch (19.1 mm) deep airspace over 1/2 inch (12.7 mm)

Insulation: 0.85, minimum.

3) Mounted with 1-1/2 inch (38 mm) deep airspace over 1-1/2 inch (38 mm)

Insulation: 0.95, minimum.

4) Mounted with 3-1/2 inch (89 mm) deep airspace over 3-1/2 inch (89 mm)

Insulation: 1.00, minimum. c. Size: 5/8 inch (16 mm) thickness with standard width to 5 feet (1524 mm) and height to 10 feet (3048 mm). d. Fabric: Refer to drawings and interior finish schedule. e. Mounting:

1) Mechanical rear mount clip.

2) Adhesive.

3) Magnetic fastener.

4) Hook and loop.

5) Edge mount mechanical clip.

4. Kinetics Applique Wall Panels: a. Description: Fabric wrapped aluminum frame with 3 pcf (48 kg/cm) fiberglass core. b. Sound Absorption (ASTM C423): Noise Reduction Coefficient of 0.85, minimum, for a 1 1/2 inch (38 mm) panel. c. Thickness: 1 inch (25 mm) core, 1-1/2 inch (38 mm) overall. d. Thickness: 2 inch (51 mm) core, 2-1/2 inches (64 mm) overall. e. Size: Standard width to 5 feet (1524 mm) and height to 10 feet (3048 mm). f. Fabric: Refer to drawings and interior finish schedule. g. Mounting: Top mounted aluminum Z-clip mounting brackets. h. Mounting: Bottom mounted fabric-wrapped brackets.

5. Kinetics Hi-Tack: a. Description: Fabric wrapped 24 pcf (384 kg/cm) density mineral fiberboard core. b. Description: Fabric wrapped 24 pcf (384 kg/cm) density mineral fiberboard perforated core. c. Sound Absorption (ASTM C423): Noise Reduction Coefficient as follows:

1) 1/2 inch (12.7 mm) Panel: 0.35, minimum. Perforated core.

2) 5/8 inch (15.9 mm) Panel: 0.45, minimum. Perforated core.

3) 3/4 inch (19.1 mm) Panel: 0.55, minimum. Perforated core. d. Core thickness: 1/2 inch (12.7 mm). e. Core thickness: 5/8 inch (15.9 mm). f. Core thickness: 3/4 inch (19.1 mm). g. Size: Standard width to 4 feet (1219 mm) and height to 10 feet (3048 mm). h. Edge Detail: Square. i. j.

Edge Detail: Round.

Edge Detail: Beveled. k. Edge Detail: Pencil.

09 80 00-8

l. Fabric: Refer to drawings and interior finish schedule. m. Mounting: 1-part mechanical clips.

6. Kinetics S-4 Absorber Panel: a. Description: Reflective film wrapped fiberglass panels. b. Sound Absorption (ASTM C423): Noise Reduction Coefficient as follows:

1) 1 inch (25.4 mm) Panel: 0.75, minimum.

2) 2 inch (51 mm) Panel: 0.95, minimum. c. Thickness: 1 inch (25.4 mm). d. Thickness: 2 inches (51 mm). e. Core: 3 pcf (48 kg/cm) density fiberglass. f. Size: Standard width to 4 feet (1219 mm) and height to 8 feet (2438 mm). g. Edge Detail: Square. h. Color: White. Not class A rated. i. Color: Aluminized silver. j. Mounting: Impaling pins. k. Mounting: Edge clips. l. Mounting: Top and bottom J-clips.

7. Kinetics SportsBoard Conform: a. Description: Perforated plastic facing and edges filled with fiberglass. 1/16 inch

(1.6 mm) thick copolymer perforated with 3/32 inch (2.4 mm) holes on 5/32 inch

(4 mm) staggered centers. b. Sound Absorption (ASTM C423): Noise Reduction Coefficient of 0.85, minimum. c. Thickness: 1 1/16 inches (27 mm). d. Thickness: 2 1/16 inches (52 mm). e. Core: 1 inch (25.4 mm) thick, 5 to 7 pcf (80 to 112 kg/cm) density fiberglass. f. Core: 2 inches (51 mm) thick, 5 to 7 pcf (80 to 112 kg/cm) density fiberglass. g. Size: As indicated on the drawings up to a maximum 42 inch (1067 mm) by 112 inch (2845 mm) panel. h. Edge Detail: Square. i. j.

Color: Refer to finish schedule.

Mounting: HS Metal impaling clips. Install with minimum 1/8 inch (3.2 mm) reveal to allow for expansion and contraction of copolymer.

8. Kinetics SportsBoard Elite: a. Description: Fabric wrapped perforated plastic facing and edges filled with fiberglass. 1/16 inch (1.6 mm) thick copolymer perforated with 3/32 inch (2.4 mm) holes on 5/32 inch (4 mm) staggered centers. b. Sound Absorption (ASTM C423): Noise Reduction Coefficient of 0.85, minimum. c. Thickness: 1 1/16 inches (27 mm). d. Thickness: 2 1/16 inches (52 mm). e. Core: 1 inch (25.4 mm) thick, 5 to 7 pcf (80 to 112 kg/cm) density fiberglass. f. Core: 2 inches (51 mm) thick, 5 to 7 pcf (80 to 112 kg/cm) density fiberglass. g. Size: As indicated on the drawings up to a maximum 48 inch (1219 mm) by 120 inch (3048 mm) panel. h. Edge Detail: Square hardened with non-resin, Class A hardening solution. i. j.

Edge Detail: Bevel hardened with non-resin, Class A hardening solution.

Edge Detail: Miter hardened with non-resin, Class A hardening solution. k. Fabric: Refer to finish schedule. l. Fabric: 100% polyester fabric, FR 701 Style 2100 by Guilford of Maine. m. Fabric: Factory approved customer selected fabric. n. Mounting: HS impaling clips. o. Mounting: Z-brackets. p. Mounting: Edgemount clips. q. Mounting: Velcro. r. Mounting: Magnetic tape.

09 80 00-9

9. Kinetics Model KNP: a. Description: Perforated metal modular panel with wrapped fiberglass batt filler. b. Sound Absorption (ASTM E795, A mounting): Noise Reduction Coefficient of

0.90. c. Steel Construction: 22 gauge galvanized steel face perforated with 3/32 inch

(2.4 mm) holes on 3/16 inch (4.8 mm) staggered centers, providing 23 percent open area. Channel/stiffener framing. d. Aluminum Construction: 0.032 inch (0.81 mm) aluminum face perforated with

3/32 inch (2.4 mm) holes on 3/16 inch (4.8 mm) staggered centers, providing

23 percent open area. Channel/stiffener framing. e. Powder coated paint finish: Refer to finish schedule for color. f. Size: 2 inch (51 mm) thickness. Refer to drawings for size, shape and attachment. g. Mounting: Flush mount Z-clips top with angle clips bottom. h. Mounting: Top Z-clip and bottom J-channel.

10. Kinetics Model KSP: a. Description: 2-5/8 inches (67 mm) thick perforated plastic panel face supported by an aluminum frame and filled with absorbent material. b. Sound Absorption (ASTM E795, A Mounting): Noise Reduction Coefficient of

0.90. c. Construction: 2 inches (51 mm) thick, 1.5 pcf (24 kg/cm) density, sound absorber encased in 2 mil (.05 mm) thick black PVC embossed vinyl and framed with 2-1/2-inch (64 mm) thick aluminum and faced with 1/16 inch (1.6 mm) thick copolymer perforated with 3/32 inch (2.4 mm) holes on 5/32 inch (4 mm) staggered centers. Paint aluminum frame to match the copolymer facing. d. Edge Detail: Square. e. Size: Standard width to 42 inches (1067 mm) and height to 120 inches (3048 mm). f. Mounting: Install with minimum 1/8 inch (3.2 mm) reveal between panels to allow for expansion and contraction of copolymer.

1) Top Z-clip and bottom J-channel.

2) Z-clips top with angle clips bottom]

11. Kinetics Geometric: a. Description: Thermo-molded PVC. b. Shape: Cylindrical. c. Shape: Pyramidal. d. Size: 24 inches (610 mm) by 24 inches (610 mm). e. Size: 24 inches (610 mm) by 48 inches (1220 mm) (cylindrical only). f. Size: 48 inches (1220 mm) by 48 inches (1220 mm). g. Finish: Standard white. h. Finish: Suede texture. i. Finish: Fabric wrapped (fabric available on cylindrical diffusers only). j. Finish: Painted finish. k. Mounting: Z-clip mounting flush to wall surface.

B. Sway Brace:

1. Kinetics KWSB: stud construction sway brace shall incorporate two interlocking "J" brackets with neoprene pad insert. Brackets made from formed 16 ga. galvanized steel punched for screw or bolt attachment.

2. Kinetics PSB: Masonry construction sway brace shall consist of fail-safe double acting neoprene elements incorporated into a galvanized steel bracket. The bracket is designed for bolt & nut attachment to the non-isolated structure. The threaded anchor is secured in the mortar between blocks. a. Kinetics PSB 6 inch (152 mm) masonry construction sway brace. b. Kinetics PSB 3 inch (76 mm) masonry construction sway brace.

09 80 00-10

C. Masonry Partition Restraint: 1-5/8 inch by 1-5/8 inch (41 mm by 41 mm) angle with 1/2 inch

(13 mm) thick isolation pad.

1. Kinetics IPRB.

D. Resilient Channel Isolator:

1. Resilient sound isolation wall clip. Clip accepts and holds furring channel in a resilient insert.

2. Kinetics IsoMax.

2.5 DUCT AND PIPE LAGGING BARRIER.

A. Fire Rated Limp Mass Outside Cover with Fiber Glass Decoupling Material:

1. Kinetics KNM 100AL-1.

2. Kinetics KNM 100ALQ-1. Quilted.

3. Kinetics KNM 100ALQ-2. Quilted.

2.6 EQUIPMENT ISOLATION

A. One piece molded neoprene mounts with encapsulated metal inserts.

1. Kinetics RD. Sized as required for load capacity.

B. Combination of a zinc-plated steel spring and neoprene noise pad encased in a two-part, interlocking, zinc-plated, galvanized steel housing, complete with foam inserts to prevent short circuiting during minor misalignment. Spring overload capacity of 50 percent and a housing overload capacity of 500 percent without failure.

1. Kinetics ARS Hanger: a. ARS-15: Static deflection of 0.50 inch (13 mm) at a rated load of 15 lb (7 kg). b. ARS-30: Static deflection of 0.50 inch (13 mm) at a rated load of 30lb (14kg). c. ARS-70: Static deflection of 0.50 inch (13 mm) at a rated load of 70 lb (32 kg).

2.7 ACCESSORIES

A. Acoustical Joint Isolation: 1/2 inch (13 mm) and 1 inch (15 mm) thick as required

1. Kinetics KAF.

B. Stud Wall Floor Plate Isolation: 1 inch (25 mm) thick pre-compressed fiberglass pad.

1. Kinetics KSM.

C. Masonry Wall Floor Plate Isolation: 1 inch (25 mm) thick pre-compressed fiberglass pad.

1. Partition isolation material shall consist of 7/16 inch (11 mm) thick molded fiber glass pads encased in a water resistant elastomeric coating. Load surface shall be a 0.25 inch (6 mm) thick hardboard NAFP-10 or galvanized steel channel PC-10 bonded on top of the isolation pad. Material shall be installed continuously beneath the wall.

2. Kinetics NAFP-10.

3. Kinetics PC-10.

D. Wall Sound Absorption Panel: 3.0 pcf (48 kg/cm) fiber glass wrapped with 10 mil (.25 mm) thick neoprene coated, fiber glass reinforced, aluminized polyester reflective film facing.

1. Panel size: Largest panel to accommodate construction and minimize joints.

2. Kinetics S4 - 1 inch (25 mm).

3. Kinetics S4 - 2 inch (51 mm).

PART 3 EXECUTION

3.1 EXAMINATION

A. Do not begin installation until substrates have been properly prepared.

09 80 00-11

B. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2 PREPARATION

A. Clean surfaces thoroughly prior to installation.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.3 INSTALLATION

A. Install in accordance with manufacturer's instructions.

3.4 PROTECTION

A. Protect installed products until completion of project.

B. Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION

09 80 00-12