S
Name of
No. Instruments
1. X-ray Machine
with Computed
Radiography
System
Specification

Dimensions: 18 3/4”W x 15 3/4”D x 19”H

Weight: Light wt. preferable for ceiling mounting.

DR Imaging System with 300,000 shutter exposure life expectancy

Imaging Media: DOUBLE SPEED Rare Earth green Phosphor Scintillate Plate

14X17 Image size, 12 mega pixel, 65,536 shades of gray, Full Frame Transfer
16 Bit

Includes: Power Cord, Computer Imaging System Interconnection Connector
Cables
X-Ray Generator

kW Rating........................................40kW

kVp Range........................................40 to 150 kVp, 1kV step

Time Range......................................0.001 to 10 sec.

mA Range........................................10 to 1000mA

HV Cable..........................................8 meters

kVp Accuracy.....................................<(1% + 1kV)

mAs Accuracy....................................<(3% + 0.01 mAs)

Generator Mounter............................Provided

Line Normal Phase..................... 240V AC, 1, 60Hz @ 70 Amps
X-Ray Tube Assembly

Model / Maker..................................Toshiba

Target Angle....................................16 Degrees

Focal Spot Size.................................6 / 1.2 mm

Max. Tube Voltage............................125kV

Max. Anode HU.................................140 kHU (100kJ)
X-Ray Collimator

Control............................................Manual, 30 sec. timer

Field Shape......................................Rectangular

Max. Field Size.................................>43 x 43 cm / 100 cm SID

Max. kV Shield.................................150 kV

Lamp..............................................Quartz Halogen 160 Lux
Digital Image Receptor

Active Matrix Size..............................14” x 17” (35 x 43 cm)

Image Matrix....................................12 Megapixels

Image Resolution..............................Exceeds FDA’s Human Radiology
Resolution Standard

Acquisition Time................................10 - 20 Seconds

Dynamic Range.................................16-bit Grayscale, 65,000 Shades of Gray

File Format........................................DICOM
Tube Stand & Float Top Table

SID .................................................Variable 12” - 40”

Grid .................................................200 lpi (ratio 10:1)

Table Top Size...................................30” x 64”

Tabletop Movement............................4 - way

Tabletop Stroke (longitudinal)..............12” (5”)

Tabletop Stroke (lateral)......................8” (4”)

Dimension.........................................32”(H) x 42”(W) x 40”(D)
Veterinary Computed radiography
1) Gray Scale resolution should be 16 bits/pixel or 65536 levels of gray scale.
2) Image access time for a 14x17 cassette should not be more than 35 seconds
3) Should not weigh more than 36kg so that it is wall mountable.
4) Spatial resolution should be minimum 100 microns or 10 pixel /mm
5) Should have a plate throughput of minimum 70 cassettes per hour for size
14”x17”.
6) Each I/P plate should guarantee 300000 artefact free exposures or three
years of warranty.
7) Should have fixed I /P plates that do not leave the cassette as scanning is
in progress.
8) Image acquisition software should have the facility of handling the
workstation with a touch screen capability. It should include the database of
the patient and should be capable to export images in DICOM and JPEG/TIFF
formats. It should possess the capability to deliver the image of the patient on
a CD, print as JPEG on paper or print it in DICOM format on film.
9) Should be FDA & CE approved.
Should have a modularized inbuilt QA software with easy to use graphical
user interface check the of the image for the acceptable levels of Erasure
Thoroughness, dark noise, uniformity, laser beam function, spatial
resolution, low contrast resolution, spatial accuracy, artifact examination,
contrast/noise, laser jitter, exposure indicator accuracy .It should also
provide for storage and retrieval of these test results and comparison
modules to compare the saved results are provided for a few tests. In
addition to this there should also be a reporting module which enables the
user to choose from the saved results of these tests and write PDF reports
indicating pass/fail criteria for each test.
12) Should be accompanied by a computer make DELL with a minimum
configuration as below:
MINIMUM Hardware Requirements:

Intel Core i5 CPU or greater

4 GB RAM or greater

7200 RPM Hard Disk with 500GB
Software Requirements:
Genuine Microsoft Windows Operating System: Windows 7 Professional 64bit with Microsoft .NET 4 and Java Version 1.6.
Should have dry laser imager and printer
Should be supplied with Blocks for cassette 2 each of all sizes
Should be supplied with telescopic cassette holder to shoot X rays of difficult
areas for large animals
Should have animal positioning device for shooting Hoof X rays
Two cassette for 17 x 14 and 10x 12 each
2. C-ARM
A Mobile C-Arm Image Intensifier suitable for use in Operation Theaters for
Surgical procedures should be provided.
A) IMAGE INTENSIFIER:



Image Intensifying Tube: 9 Inches, Triple Field.
CCD Camera: High Resolution Compact CCD Camera.
Monitor (2 Nos): 2 Nos. 19” medical grade monitors along with
modular trolley should have features like:
A) Foldable monitors.
B) Actuator assisted up/down movement of monitors to facilitate viewing of images
at most convenient eye level positions
C) Specially designed integrated keyboard having feather touch keys and touch pad is
provided instead of double unit keyboard and mouse
D) 5 inch wheels for better mobility with kick stop provision in two wheels for
parking stability.
B) C-ARM MOVEMENTS:
1. Rotation:  180 Degrees.
2. Up/Down Movement Motorized: At least 400mm.
3. Horizontal Travel: 200 mm or more
4. Arc Orbital Movement: At least 110 Degrees or more.
5. Wig Wag: ±12.5 Degrees.
6. Source to Image distance should be more than 900mm.
7. Depth of “C” should be 600 mm
C) X-RAY GENERATOR:
 High Frequency (50 KHz)
 Output power should be at least 3KW or more
 Rotating Anode Tube of focal spot 0.3mm & 0.6mm.
 Radiographic mA: 60mA or more
 Fluoroscopic mA: 0.1- 5mA (Normal Mode), Pulsed Fluoro for High
definition Fluoro should be more than 10 mA.
D) CONTROL PANEL:

LCD Display for following parameters should be provided:
Display on which KV, mAs, Fluoro Time, I.I ZOOM and Body part, View
of Radiography are displayed on Wide angle LCD.

APR (Anatomical Programming) in Radiography Mode i.e. preselected parameters are programmed in the machine as per the Body Part
selected/to be exposed should be provided. APR should cover Head, Chest,
Abdomen and extremities.

Exposure Modes: Continuous and Pulsed Fluoroscopy up to upto30
FPS.
- Radiographic Mode (cassette exposure) up to 120 KV & more than 80mA.

Timer (Fluoroscopic): Fluoroscopic cumulative timer of 5 minutes
with beep.

Tube safety Sensor: X-Ray Tube head Temperature Sensor for
Thermal Safety cut off.

Switches: - Mode Selector Switch.
- Collimator Control Switches.
- I.I. Zoom Selection Switches.
- Exposure initiation Switches for Fluoro/ Radiography.


ADRC MODE: Auto Dose Rate Control for consistent image quality.
Self Diagnostic: Various system interlocks should be displayed on
LCD screen for effective and prompt troubleshooting.
E) MEMORY SYSTEM should include the following: -














Image plus software
2 LCD monitors system for LIH, LIVE and stored images.
Permanent image storage capacity of approx. 10,000 images.
50 temporary image storage for quick review.
DVD writer to store images on CD/DVD for giving it to patients.
Flicker free images on a flat screen.
32 bit image storage for excellent resolution.
Image sharpening (real-time or stored images).
Image rotation of 15º step.
Image EMBOSS for three-dimensional relief presentation.
Colorized images.
Dynamic contrast control (Gray Level Stretch).
Negative images (Gray Level Invert).
Frames averaging for smoothing ofiImages. (Real time) 256
frames.




32 bit at 800 x 600 resolutions.
Digital subtraction of images.
QUAD view (4 images on monitor).
Cine loop of 500 frames (Multiple cine loops can be stored
permanently).

Variably frame rate of 2, 5, 10, 15 & 27 frames per second for cine
loop.


Image orientation: Left/ Right – Top/ Bottom.
Patient’s Name, operator name, hospital name, date and time
display on monitor.


Images can be stored in folders of individual patient’s name.
Quick exploration of stored images.







ON screen help mode.
ON screen measurements – Length (X and Y) and Area.
Area of interest marker.
Contrast enhancement of area of interest.
Histogram of area of interest.
Facility for image printing.
Text annotations and provision of removal of all text from the
image.





Automatic capture and storage of cine loop with cine foot switch
Offset and gain adjustments for improved image quality.
Thumb nail use of complete study
Frame by frame review.
Printing options in different formats (frames of different loops can
be printed on the same sheet, 1x1, 1x2, 1x4, 1x8 formats)





Frame rate selection
LAN connectivity.
DICOM Ready
Branded processing unit
Specifications: Dell Desktop Vostro-220/Lenovo
1. Intel dual core 2.5Ghz or above processor
2. Intel mother board
3. 1 GB DDR-II RAM
4. 160GB or above hard disk drive
5. DVD writer
6. 512 MB dual head VGA card
7. Specially designed integrated keyboard having feather touch
keys and touch pad is provided instead of double unit
keyboard and mouse
F) Power requirement: The unit should be operable on Single Phase 230 V ±
10% AC, 50 Hz
G) Servo voltage stabilizer of 2KVA should be provided.

The system should be upgradable to DSA.
G) Other Requirements:
 The Equipment must be European CE Certified.
 The company must be ISO & EN ISO certified.
 The unit should be approved by AERB.
 The company should have proven trade record in Govt. Sector.
3. Small Animal
Anaesthesia
The equipment should be / have 
Suitably designed for veterinary use (mainly for small / pet animals)
Machine



Easy to clean, have good finishing and the material should be rust proof.
Provision of mounting bracket for mounting two vaporizers.
Supplied with brand new precision Isoflurane vaporizer of premium quality
which should be temperature, pressure and flow compensated.

Fitted with specific breathing circuits like non re-breathing system,
partial re-breathing system and total re-breathing system.

Circle system fitted with fresh gas inlet, corrugated breathing tubes, reservoir
bag and pressure gauge, unidirectional aspiratory and expiratory valves; pop
off valves as safety device and oxygen flush system. Soda lime carbon dioxide
gas absorber (capable of absorbing CO2 expired from 2 kg to 100 kg body
weight).
Scavenging system.
Fitted with unbreakable valve dome caps.



The CO2 absorber should be efficient in absorption, seal easily
and be leak free seal.

capable of working with vaporizer out of circle and vaporizer in the circle.

Fresh gas outlet for easy use of a non re-breathing system.

Oxygen flow meters of measuring capacity up to 4 liter per minute or
more

Fitted with low oxygen audio alarm.

supplied along with Bain circuit.

supplied with different sized veterinary specific induction masks
having good fitting rubber diaphragms for variable sized small animals

supplied with good quality cuffed silicon reusable endotracheal tubes
of sizes 2-14 FR along with adaptors of suitable sizes 10 each.

supplied with re-breathing bags of different sizes ranging from 0.5 . 1,
2, 3 and 5L 5 each.

compatible for working with IPPV.

The mobile trolley should have five legs for maximum stability (two
with brakes), stainless steel body, one drawer and platform build on the
top for mounting vital signs monitor.






Mouth gags set of 3 to suite variety of animals
Veterinary specific Laryngoscope
Complete with veterinary anesthesia ventilator fitted
Veterinary specific hand held monitor with SPO2,
Pulse and temperature measurement
Enclose catalog and list of user with telephone and Email ID

The machine should have minimum 2 years warranty/ guarantee period
and subsequent AMC rates may be quoted.

Bain system and attachement tube 3 piece.

Oxygen Cylinder-pin type-water capacity 5lit, 0.75cubmm gas
capacity
4. Large animal
Anaesthesia
Machine with
ventilator

The equipment should be / have Suitably designed for veterinary use in large animal (mainly
Bovine, equine and small ruminants) with inbuilt ventilator

Machine should be Micro processor based electronic control
system incorporates the features of current intensive care
ventilators with micro processor technology.


LED display of Selected respiratory variables
Inverted 18 litres bellows ascending during exhalation for near to
natural breathing
Patient (animal) may breathe spontaneously from the bellows.
Flow rate adjustable from 0-600 litres per minute with expanded
range of flow rate selectivity.
Extremely quite in operation.
Mulitiple electrical outlets with surge protection.





Ventilator should be/have -able to work on 110-220V
-tidal volume adjustable (with facility for momentary switch to flush up
to 15ltrs)
-electronically controlled, time cycled, pneumatic powered.
-adjustable frequency (minimum range 0-90 BPM)
-adjustable control of inspiratory flow
-have varying Inspiration /expiration ratio (range 1:1 to 1:4.5)
with upgradation facility.





Provision of mounting bracket for mounting two vaporizers.
Supplied with brand new precision Isoflurane vaporizer (range 0%5%) of premium quality which should be temperature compensated.
Should be supplied with Foal Absorber, three 30 liter bag, three
15 ltr bag compatible with machine, wye piece, and tubing
required.
Absorber- circuit should have pressure gauze, APL valve (allowing
to make the circuit from completely closed to fully open), check
valve for insipratory and expiratory flow. The CO2 absorber should
be efficient in absorption.
Scavenging system.
5. Veterinary
Multipara monitor

Supplied with 4 set of cuffed/ without cuff endotracheal tubes of 12, 14
,16,14 , 18, 20 and 22

One set laryngoscope suitable for large animal.












Alarms:
Failure to cycle -visual-audible
System failure - visual-audible
Overpressure governor 80cm H2O
Gas scavenger - 19mm port
Controls
Inspiratory Time-1-3 seconds
Inspiratory flow - 10 -650 LPM
Inspiratory Pressure - 10-70 mm H2O
Rate - 2-80 BPM
Pneumatic manual push button for inspiration.
No need to remove the bellows for cleaning, the bellows should be
cleaned in place.

Oxygen cylinder: 46-47 lit water
1. Veterinary specific monitor with veterinary probes for use on variety
of animals
2. Should have a battery back up of at least 2 hours.
3. Should be have SPO2, NIBP, Temperature,Respiration, ECG and Pulse
rate
4. ECG cables should be veterinary specific with alligator clips
5. NIBP cuffs should be veterinary specific
6. SPO2 and pulse sensor should be easily attached to tongue and ear of
the animal
7. Screen size should be minimum 10 Inches or more
8. company should provide veterinary user list
Unit should have 3CH ECG : Full 7 ECG & ST Segment analysis &
12CH ECG : Full 12 ECG & ST Segment analysis.
9. Unit should have more than 13 Arrhythmia analysis &
Pacemaker detection.
10. Unit should have more than 160 hours of tabular and graphic
trend data save facility.
11. Unit should have facility for Drug Dose Calculation, ECG Recall,
Mini Trend, ICO, Color change, NIBP STAT, NIBP VENOUS STAT,
OXY-CRG, Patient information Entry
12. It must have Built in Printer
13. Unit should be fully equipped with software for canine, equine,
feline, ovine, bovine etc applications.
Unit should be provided with the following accessories:
14. 5 lead ECG cable: 2No.
15. ECG electrodes: 50no.
16. NIBP CUFF (As require in veterinary application of different
species):3 no.
17. Temp. Probe: Rectal & skin. SPO2 Probe: 03 no each.
6. Ophthalmic
instruments
a) Surgical Veterinary operating Microscope
1. Should have good optics with coaxial illumination with optical light
guide
2. Easy mobility
3. Should have 3 step Magnification
4. Binocular tube with 45 Degree illumination
5. Working distance 175mm and eyepiece 12,5X
6. Field of vision 43mm, 26mm and 16mm
7. Microscope floor Stand with lockable caster wheels
8. Size of base should be 600mm x 560mm
9. Should be supplied with veterinary applanation tonopen for accurate
IOP measurements for variety of animals
Unit should be provided with the following accessories:
1. Camera 35mm attachment
2. Assistant Binocular microscope
b) Indirect Veterinary Opthalmoscoipe
Synchronized Adjustment of Convergence and Parallax for high quality,
stereoscopic fundus images through any pupil size.
Precise selection of the observation and illumination optics for small pupils
down to 1.0mm.
Should have the multi-coated illumination system.
Exact vertical alignment of the illumination with the observation path further
minimising the reflections.
PD Range: From 46 – 74mm.
 Phaco machine
Ultrasound phacoemulsification
Frequency: 28 kHz, piezo driver
Control: auto-tuning (50 times/s),
linear, pulsed, burst, cool
micropulse phacoemulsification
Power: 1-100% in steps of 1%,
max. deflection 120 IJm
Pulse: pulse frequency 0.5-40 Hz,
pulse duration 0.25-1800 ms
Counter: effective time in 0.1 s
(relevant to energy delivered)
Memory: 9 surgeons with 3
memory settings each
I/A System
Continuous irrigation function
Pump system: peristaltic, linear
control, proportional override
Reflux: pump reverse (150 mmHg)
Tubing System: single use or
autoclavable 250 ml wastecontainer
Memory: 9 surgeons with 2
memory settings each
Performance: 0-50 ml/min,
vacuum 0-600 mmHg
Diathermy
Frequency: 500 kHz, pulsed
Power: max. 8 Watt at 500 hm
HF Capsulotomy
Frequency: 500 kHz, pulsed
Power: max. 6.2 Watt at 500 hm, 2
ranges, automatic regulation
Vitrectomy
Speed: 30-1200 cuts/min
Drive: electric, push/pull
Power requirements
Electric: 100-240 VAC, 50-60 Hz,
power consumption 200 VA
Dimensions & Weight
Dimensions: not more than 220 x
241 (plus 50 mm for handle) x 154
mm (IN pole clamp adds 80 mm)
w/h/d
Weight: not more than 6 kg
Linear pedal: 180 x 250 mm base
plate 2.75 kg
Standards
IEC601-1, EN60601-1, UL 544,
CE-Mark (CE-class 2B, protection
class I)
EMC/RFI: EN 6100-4-1, EN
50011/ EN 55081-1 EN 50082
7.
Veterinary dental
workstation
High Speed Veterinary Dental Air Unit. This all-in-one veterinarian dental cart,
performs all necessary procedures from cutting-polishing-scaling.
Features:
Dental Workstation Hand Pieces and silent compressor with
Fibre optic Light System for high speed Hand pieces. Suction
Unit – Variable suction and bacterial Filter , Automatic Hand
piece activator and consumable kit
Adjustable Height stainless Steel floor stand with castors
ultrasonic scalar with 4 tips
Foot Switch for Piezo Scaler
Dental Bur Kit FG 19mm for Dogs, Dental polisher
Dental Hand Instruments – 2. Sets of 14 Pieces Instrument Set
with Small handle
winged elevators consist of
Winged Elevator 1mm, 2mm, 3mm and 4mm
Root tip pick
Periosteal Elevator
Subgingival Curette
Jaquette Supragingival Scaler
Sickle Scaler
Explorer / Measuring Probe
Very fine periosteal elevator
Extraction Forceps
Tartar Removing Forceps
Minnesota retractor
Specialized Dental Instruments
Molt, Periosteal Elevator
curved deciduous elevator sml
curved deciduous elevator med
curved deciduous elevator Lge
Small Breed / Cat right angle extraction forceps
Mouth Gag Sml 5cm opening
Mouth Gag Med 8cm opening
Mouth Gag Lge 12cm opening60”
8. Physiotherapy
instruments





SHORTWAVE CUM PULSE DIATHERMY UNIT-1000W
TROLLEY MODEL
MAJOR TENSE (Pain Reliever)- 4 Channel Digital
MINI TENSE (Pain Reliever)- Double Channel
INTERFERNTIAL THERAPY UNIT WITH STIMULATOR(LCD
ULTRASONIC STIMULATOR/THERAPY- MICRO

CONTROLLED BASED (LCD)
INFRA RED COMBINED WITH UVR WITH TIMER\
Shock wave therapy system
Powerful energy range, individually selectable
Reliable therapy for deep penetration areas
Large focal zone, increased targeting precision
Simple changeover from focused to radial applicator, wide
spectrum of indications
Should be usable in large as well as small animal therapy.
9. Equine surgery
Table
The Large Animal Table should have rust proof surface coating
The table should be user friendly and can be used for equines,
bovines etc.
The table should be provided with 4 Vertical poles
Minimum Height should not be more than 50cm.
Maximum Height Should not be less than 1.10m.
Should have features of Pelvic angle +/- 8 Degree and head
support+/- 20”
The Large Animal Table should be supplied with Anesthetic hose
support for ease during anesthesia and moveable rack.
The Large Animal Table should be provided with PVC padding of
90-100mm thickness.
Table should have locking device for the wheels should be
mounted on the frame
The side panels should be steplessly control by gas hydraulic
cylinders.
And should be easily removable
Should be supplied with 2 horizontal bars with clamps and 4
clamps for belt
Should be supplied with 4 coated foam strips for head section and
side panel and
4 wedge-shaped foam paddings
Table should have inbuilt battery back up for atleast 20 lifts and
charging time should not exceed 6 hours. The Table should also
work while battery is being charged. External batteries not
acceptable.
The side supports and head supports should be detachable
The Large Animal Surgery Table should be equipped with safety
features at each corner and head support to avoid leg injury while
lowering the table
Should be supplied with following accessories.
Large Colon Tray which can be placed caudally or laterally.
Leg Support
2 leg support (Orthopaedic) – adjustable
The quoting company should have supplied similar unit to some
veterinary institution in India and if required should be able to
provide demonstration if required
Company should should provide user list along with the catalog
10.Instruments for
cryosurgery








11.VIDEO
GASTROSCOPE
,LAPAROSCOPE,
BRONCHOSCOPE,
CYSTOSCOPE &
OTOSCOPE
for SMALL &
LARGE ANIMAL
“A,”B” and “C” spray apertures
An 18 mm cryochamber
A 1 cm flat probe
A malleable extension which makes surgery convenient in any
position.
Slender, fingertip trigger for maximum control and ease of
viewing-also rotates easily for left-hand users.
Streamlined relief valve maintains a constant operating pressure
to ensure consistent and accurate freezing.
Stainless Steel and brass construction for long life
Cryocan-15 lit and 25 lit capacity
. VIDEO GASTROSCOPE – Insertion tube outer diameter
10-10.4 mm,
instrument channel 2.0-2.8 mm, working length 250-300 cm, deflection of
distal tip(up – down) 180/200° – 100°, deflection of distal tip (left – right) 120°
- 120°, field of view 140° or more, depth of field 2 – 200 mm, CCD chip size
1/6”, resolution- 480,000 pixels or more , two programmable control keys on
handgrip & four way deflection locks.
Accompanied with accessories -biopsy forceps with double action jaws,
grasping forceps with double action alligator jaws, polypectomy snare ,
cytology brush, foreign body basket, Injection needle with retractable tip,
carrying case, ETO cap, leakage tester, caps for working channel, Irrigation
tube, instrument oil, bite protector ,cleaning brush, cleaning valve & video
connecting cable.
2. LAPAROSCOPE

Telescope forward-oblique 30° enlarged view, with outer diameter
4.5- 5 mm, length 27-29 cm and should be autoclavable. Having rod
lens system and incorporated fiber optic light transmission
Forward-Oblique Tele- scope 0°, enlarged view, diameter 9.5-10 mm,












length 55-57cm, and should be autoclavable. Having rod lens system
and incorporated fiber optic light transmission
Threaded trocar , size 6 mm , length 8.5 cm with multifunctional
valve & Insufflation stopcock.
Telescope stopper size 11-5mm , with minimum 10 in a package.
Threaded cannula , size 6 mm, working length 6.5 cm with silicon
leaflet valve.
Trocar with pyramid tip, size 6mm, length 8.5 cm with multifunctional
valve & Insufflation stopcock.
VERESS pneumo-peritoneum needle , length 10 cm, with springloaded blunt stylet and LUER-Lock
Reducer 11mm to 6mm size clip-on type = 04
Grasping forceps, rotating, size 5 mm, length 36 cm with multiple
teeth, fenestrated, single action jaws.
Scissors with serrated double action jaws, curved with spoon blades
size 17 mm , 360 deg sheath rotation, size 5 mm, length 36 cm.
Dissecting and grasping forceps with long double action jaws, 360 deg
rotating sheath, size 5 mm, length 36 cm.
Bipolar grasping forceps, insulated, fit for coagulation, diameter 5 mm
.
Dissecting and biopsy forceps with single action jaws, rotating, size 5
mm, length 36 cm.
Threaded trocar , size 11 mm , length 10.5 cm with multifunctional
valve & Insufflation stopcock
3. CYSTOSCOPY SET –
 Female cystoscopy Set-
Autoclavable , topline telescope forwardoblique 30° enlarged view, with OD 2-3 mm, length 17-19 cm having
rod lens system. Should include cystoscopy sheath (14.5 Fr. with builtin instrument channel 5 Fr. and obturator), Grasping Forceps (flexible,
long & short) ,Biopsy forceps with double spoon & oval jaws (flexible,
long & short) & Stone Basket.
 TCI Set-
Autoclavable, Forward-Oblique Tele- scope 6°, angled
eyepiece, diameter 9.5 fr at tip and 13.5 fr at distal end with catheter
channel of 6 fr, length 40-45 cm, incorporated with instrument port,
seal and cleaning adopter. Should include TCI catheter, Grasping
Forceps for large and small stones & fragments and biopsy forcep.
 Vagino Proctoscope
For large, medium & small size animal with
diameters 20 mm, 15mm & 11mm with suitable working lengths and
obturator. Should include light cable, telescope bridge & biopsy forcep
of suitable size.
 Urethro-cystoscopy Set for male dog-
Flexible scope with
Instrument channel: 1.2 mm. Direction of view: 0°, Angle of view: 90° ,
Working length: 100 cm, Outer Diameter: 3.0 mm .Following
accessories should be included: grasping forcep, biopsy forcep , stone
basket, carrying case , pressure compensation cap , leakage tester &
cleaning brush.
4. VIDEO BRONCHOSCOPE
– Insertion tube outer diameter 5.5-6.4
mm, instrument channel 2.0-2.2 mm, working length 65-70 cm, deflection
of distal tip(up – down) 180°/100°, field of view 120° or more, depth of
field 2 – 50 mm, CCD chip size 1/6”, resolution- 480,000 pixels or more ,
two programmable control keys on handgrip & four way deflection locks.
Accompanied with accessories -biopsy forceps with double action jaws,
grasping forceps with double action alligator jaws, polypectomy snare ,
cytology brush, Injection needle with retractable tip, suction Catheter,
diameter 1.7-2.0mm with adopter carrying case, ETO cap, leakage tester,
caps for working channel, Irrigation tube, instrument oil, bite protector
,cleaning brush, cleaning valve & video connecting cable.
5. OTOSCOPE- Otoscope , 5mm and 8.5 length with Stopcock [with
integrated working channel for irrigation & instruments insertion],
Autoclavable.
Accompanied with accessories -biopsy forceps , grasping forcep, ear
curettes, myringotomy needles, cleaning brush, aspiration needles , LED
battery light source with charger, etc.
6. ENDOVISION SYSTEM
Integrated, compact & portable system combining light source,
camera control unit, documentation, Insufflation , Irrigation &
monitor all in one . Should be compatible with all types of rigid and
flexible scopes with option of direct image and video archiving
(through USB ports/SD card directly), image editing, zoom functions
and generation of patient report. Monitor size should be minimum
15” with light output of 50 W Hi lux. Other features like DVI video
output facility and integrated 3 speed, adjustable insufflations
pump are mandatory.
The unit should be complete with heat resistant 300 cm long optical
light cable , camera head with integrated image processing module,
adopter to connect all types scopes, tubings to connect irrigation
and insufflations, keyboard & foot pedal to control functions..
7. LIGHT SOURCE-
8.
XENON 100 watts with built in adopter to connect
video endoscopes and Integrated pump for air insufflation & water
irrigation. Max. pressure -0.5 bar , max. flow rate- 5l/min, operating
temperatures- 0-40 degrees C and operating humidity-30-90%. Should be
compatible for use with all types of scopes by means of a special quick
adopter .
Should be accompanied by one spare lamp, fibre optic light cable and
adopter to connect all rigid and flexible scope .
CAMERA SYSTEM- Digital, single-chip medical-video-camera
compatible with all rigid and flexible scopes. Image sensor of ½” CCDchip, picture elements- 752 (H) x 582 (V) pixels per chip (PAL) , resolution
minimum 450 lines (horizontal) , exposure control of 1/60 sec- 1/10000
sec, signal-to-noise ratio: > 50 dB & min. sensitivity of 3 Lux (f =1.4),
Lens with integrated zoom lens of f=25-50mm . Instrument coupling
device should be compatible with all rigid & flexible endoscopes with
standard eyepiece. Adaptable to an operating microscope by means of a
special quick adapter, camera head fully soakable for sterilization & also
gas sterilizable and sterrad compatible.
9. INSUFFLATION UNIT- Fully automatic with electronically controlled
gas refill. Gas flow/minute 0-20 lit , pressure 0-100mm of Hg. ; intraabdominal pressure gauze -0-100 mm of Hg .Capability for usage in
laparoscopy and advance arthroscopy procedures . Have touch keys for
precise pre-selection of preset values , built in optical & acoustic signals in
case of overpressure. Complete with all connecting tubings, hose pipe 1.52 meter long , regulator and 4.5-5 kg CO2 cylinder.
10. HIGH FREQUENCY SURGICAL UNIT- Power Output
200 W or
more with coagulation degree pre-selectable in several stages like soft &
standard coagulation, voltage-controlled cutting, auto-stop & auto-start
function, option of activating HF functions either via footswitch or switch
on the handle. Complete with two pedal footswitch, monopolar & bipolar
cords, neutral electrode of conducive silicon.
11. OTHERS


LCD monitor 19"
Mobile cart having 4 antistatic dual wheel, locking brakes, 1 fixed
shelf .
Standards & Warranty
1. Manufacturer must be EC certified for Full & Production Quality
assurance.
2. Manufacturer must be ISO -13485: 2003 & ISO -9001:2008 certified
for quality standards.
3. Manufacturer should quote FDA , CE,UL or BIS approved product,
minimum three years from this ITB.
4. Product should have IEC safety standards where ever listed . All
products should be IEC 601-1, CE certified according to MDD.
5. Manufacture should have minimum 10 installations in Government
Institutions
including
Veterinary
Universities/ICAR
centres/AHD/Municipal Corporations etc with at least 5 installation in
Northern India.
6. Must have a veterinary training centre in India.
7. Manufacturer should have its own full fledged Corporate office along
with service centre in India.
8. All units must be covered under standard warranty for a period of 24
months from the date of installation.
9. The core operating laparoscope like telescopes, endovision ,single
chip camera, light source, CO2 Insufflator, hand instruments (unipolar
forcep, probe) fiber optic cable, veress needle etc should be from
single manufacturer for system compatibility. No mix & match of
different companies is acceptable.
1. System to lift large animal comfortably of 1000 body wt.
2. Should have a belly support cover
3. System comprises of Chain and pulley system with ease of use when
working with large animals
4. should be complete with Rods and chain pulley wheel so that animal
can be move from one place to others easily.
12.Large Animal
Lifter
13.Large animal trolley
Manually operated 2 feet height 7 feet length 5 feet width
T Handle, trolley stationed on 4 wheels
6” mattress along with tarpal should be provided
List of user list and catalog to be provided
cum operation table
14.Large animal
Shadow less lamp
15.Bovine Stomach
Pump











Light wt. ceiling mounted shadow less lamp with minimum
18,000 lux for large animal O.T.

Pump for delivery of liquid nutrients and medicants

The Dairymac Med-Eze Stomach Pump and Stainless
Steel Stomach Tube assembly is a high quality unit
designed by a veterinarian in the USA for ease of use,
durability and rapid cleaning

The Dairymac Med-Eze Stomach Pump and Stainless
Steel Stomach Tube assembly is a high qualit y unit
designed by a veterinarian in the USA for ease of use,
durability and rapid cleaning.

Large volumes of liquid can be pumped quickly with the
minimum of effort.
Leak proof pump
Durable stainless steel construction eliminates corro sion
Easy and consistent draw for delivery of product
Reduces arm and shoulder fatigue
Three strokes delivers 1 litre
Reversible for removal of stomach contents
Includes Pump and Hose Adapter
Includes 2m Whiplash Stainless Steel Stomach Tube and
Nose Clamp
Durable 2 metre long rubber hose to connect to pump
with probe
Precise volume delivery
16.Theloresectoscope
for teat surgery
“Mini Plus” basic set with battery handle, air pump, new instruments,
complete in transportation case
Consisting of:
Wide angle telescope, 0⁰, large image technology, OD: 3mm, WL: 14cm,
standard light cable connectors
**Special robust construction for use in field practice – autoclavable*Sheath, OD: 4mm, WL: 12cm for telescope T141-3000, stop including sharp
trocar
Inflation pump, battery operated, incl. 1.5m silicon tube LL(m), air filter,
delivered without batteries
Spare batteries, type:Mignon AA, 1.5VDC, package with 2 pcs., alkaline
Special teat clamp, with ratchet, size 12cm,
Special teat probe, Teat knife and Stenosis cutter set 4 and 3.4mm
Cleaning brush small 17cm
Sterilization and storing case 200x140x40mm
LED endoscope light handle, mini, 1.5VDC, 90g, comp.to Dr.Fritz/Wolf,
including mignon battery Aa
Spare batteries, type: baby, 1.5VDC package with 2 pcs., alkaline (without
picture)
17.
18.Furniture and
LCD projector
for Seminar
Room,
19.Automatic Shoe
wrapper for small
animal O.T.
20.Air conditioner
for PG lab
21.UPS with Battery
Audience chair, sound system, smart board, podium, screen
remote operated
Automatic shoe wrapper for small animal O.T. with 2000
disposable shoe wrapper
1.5 tone with stabilizer starting from 130 V
2Kv UPS of reputed company 2000W along with two battery
150AH.
Double story refrigerator
22.Refrigerator for
PG Lab
23.Desk top, UPS
with multifacility
printer for PG lab
Silent Generator 15 KVA preferably escott brand
23
for TVCC
LED Monitor
24
LED monitor of 36 inch.
Fire Extinguisher Portable, Wall mounted, 9 kg capacity, Body material MS,
25
Material ABC, squeeze grip, suitable for all
classes of fire.
Ambulance Van Should be suitable for animal ambulation along with all
25
26
CCTV SET For
O.T.
27
Mobile Large
Animal Carrying
System
facility like –vital parameter monitoring
machine, oxygen therapy.
4channel videooutput, support ich, IP camera, 1 SATA port
upto 4TB, 2 USB ports, 1RJ45, 1RS 485,
HDMI/VGA, Mobile software, IR Dome Camera,
1/3” sony ccd sensor, 700 Tvt, 0.01 lux/0lux,
3.6mm lens, 24leds, upto Mtrs, camera holder,
cctv 3+1, installation and warranty.
Fuel operated Mobile Large Animal Carrying System
• Should have 3000kg load capacity
• Should have 500 mm load center
• Should have 2 small front & 2 large tyre
Lifting or pulling Large Animals stuck in mud or ravines.
Mast Details
• Should have wide view mast
• Should have fork height 3000mm
• Should have 3000 kg load capacity
• Should have 1800-2200mm lowered height
• Should have 180 mm approx. free lift.
Attachment • Should have Shovel attachment
• Size of shovel should be 1320 x 1225 x 710 mm
• Should have crane attachment with 1200 mm length
• Should have attachment of vertical G.I. shaft with pullies or hooks at two end
and in center for lifting of animals
• Should have three sets of slings for lifting of large animals
28
Metal Detector
Instruments should be sufficient powerful to detect any foreign metallic
object in large ruminant stomach.
Download