……………/Surg/BVC Date:……../01/15 Department of Surgery and Radiology Bihar veterinary College, patna List of Instruments S Name of No. Instruments 1. X-ray Machine with Computed Radiography System Specification Dimensions: 18 3/4”W x 15 3/4”D x 19”H Weight: Light wt. preferable for ceiling mounting. DR Imaging System with 300,000 shutter exposure life expectancy Imaging Media: DOUBLE SPEED Rare Earth green Phosphor Scintillate Plate 14X17 Image size, 12 mega pixel, 65,536 shades of gray, Full Frame Transfer 16 Bit Includes: Power Cord, Computer Imaging System Interconnection Connector Cables X-Ray Generator kW Rating........................................40kW kVp Range........................................40 to 150 kVp, 1kV step Time Range......................................0.001 to 10 sec. mA Range........................................10 to 1000mA HV Cable..........................................8 meters kVp Accuracy.....................................<(1% + 1kV) mAs Accuracy....................................<(3% + 0.01 mAs) Generator Mounter............................Provided Line Normal Phase..................... 240V AC, 1, 60Hz @ 70 Amps X-Ray Tube Assembly Model / Maker..................................Toshiba Target Angle....................................16 Degrees Focal Spot Size.................................6 / 1.2 mm Max. Tube Voltage............................125kV Max. Anode HU.................................140 kHU (100kJ) X-Ray Collimator Control............................................Manual, 30 sec. timer Field Shape......................................Rectangular Max. Field Size.................................>43 x 43 cm / 100 cm SID Max. kV Shield.................................150 kV Lamp..............................................Quartz Halogen 160 Lux Digital Image Receptor Active Matrix Size..............................14” x 17” (35 x 43 cm) Image Matrix....................................12 Megapixels Image Resolution..............................Exceeds FDA’s Human Radiology Resolution Standard Acquisition Time................................10 - 20 Seconds Dynamic Range.................................16-bit Grayscale, 65,000 Shades of Gray File Format........................................DICOM Tube Stand & Float Top Table SID .................................................Variable 12” - 40” Grid .................................................200 lpi (ratio 10:1) Table Top Size...................................30” x 64” Tabletop Movement............................4 - way Tabletop Stroke (longitudinal)..............12” (5”) Tabletop Stroke (lateral)......................8” (4”) Dimension.........................................32”(H) x 42”(W) x 40”(D) Veterinary Computed radiography 1) Gray Scale resolution should be 16 bits/pixel or 65536 levels of gray scale. 2) Image access time for a 14x17 cassette should not be more than 35 seconds 3) Should not weigh more than 36kg so that it is wall mountable. 4) Spatial resolution should be minimum 100 microns or 10 pixel /mm 5) Should have a plate throughput of minimum 70 cassettes per hour for size 14”x17”. 6) Each I/P plate should guarantee 300000 artefact free exposures or three years of warranty. 7) Should have fixed I /P plates that do not leave the cassette as scanning is in progress. 8) Image acquisition software should have the facility of handling the workstation with a touch screen capability. It should include the database of the patient and should be capable to export images in DICOM and JPEG/TIFF formats. It should possess the capability to deliver the image of the patient on a CD, print as JPEG on paper or print it in DICOM format on film. 9) Should be FDA & CE approved. Should have a modularized inbuilt QA software with easy to use graphical user interface check the of the image for the acceptable levels of Erasure Thoroughness, dark noise, uniformity, laser beam function, spatial resolution, low contrast resolution, spatial accuracy, artifact examination, contrast/noise, laser jitter, exposure indicator accuracy .It should also provide for storage and retrieval of these test results and comparison modules to compare the saved results are provided for a few tests. In addition to this there should also be a reporting module which enables the user to choose from the saved results of these tests and write PDF reports indicating pass/fail criteria for each test. 12) Should be accompanied by a computer make DELL with a minimum configuration as below: MINIMUM Hardware Requirements: Intel Core i5 CPU or greater 4 GB RAM or greater 7200 RPM Hard Disk with 500GB Software Requirements: Genuine Microsoft Windows Operating System: Windows 7 Professional 64bit with Microsoft .NET 4 and Java Version 1.6. Should have dry laser imager and printer Should be supplied with Blocks for cassette 2 each of all sizes Should be supplied with telescopic cassette holder to shoot X rays of difficult areas for large animals Should have animal positioning device for shooting Hoof X rays Two cassette for 17 x 14 and 10x 12 each 2. C-ARM A Mobile C-Arm Image Intensifier suitable for use in Operation Theaters for Surgical procedures should be provided. A) IMAGE INTENSIFIER: Image Intensifying Tube: 9 Inches, Triple Field. CCD Camera: High Resolution Compact CCD Camera. Monitor (2 Nos): 2 Nos. 19” medical grade monitors along with modular trolley should have features like: A) Foldable monitors. B) Actuator assisted up/down movement of monitors to facilitate viewing of images at most convenient eye level positions C) Specially designed integrated keyboard having feather touch keys and touch pad is provided instead of double unit keyboard and mouse D) 5 inch wheels for better mobility with kick stop provision in two wheels for parking stability. B) C-ARM MOVEMENTS: 1. Rotation: 180 Degrees. 2. Up/Down Movement Motorized: At least 400mm. 3. Horizontal Travel: 200 mm or more 4. Arc Orbital Movement: At least 110 Degrees or more. 5. Wig Wag: ±12.5 Degrees. 6. Source to Image distance should be more than 900mm. 7. Depth of “C” should be 600 mm C) X-RAY GENERATOR: High Frequency (50 KHz) Output power should be at least 3KW or more Rotating Anode Tube of focal spot 0.3mm & 0.6mm. Radiographic mA: 60mA or more Fluoroscopic mA: 0.1- 5mA (Normal Mode), Pulsed Fluoro for High definition Fluoro should be more than 10 mA. D) CONTROL PANEL: LCD Display for following parameters should be provided: Display on which KV, mAs, Fluoro Time, I.I ZOOM and Body part, View of Radiography are displayed on Wide angle LCD. APR (Anatomical Programming) in Radiography Mode i.e. preselected parameters are programmed in the machine as per the Body Part selected/to be exposed should be provided. APR should cover Head, Chest, Abdomen and extremities. Exposure Modes: Continuous and Pulsed Fluoroscopy up to upto30 FPS. - Radiographic Mode (cassette exposure) up to 120 KV & more than 80mA. Timer (Fluoroscopic): Fluoroscopic cumulative timer of 5 minutes with beep. Tube safety Sensor: X-Ray Tube head Temperature Sensor for Thermal Safety cut off. Switches: - Mode Selector Switch. - Collimator Control Switches. - I.I. Zoom Selection Switches. - Exposure initiation Switches for Fluoro/ Radiography. ADRC MODE: Auto Dose Rate Control for consistent image quality. Self Diagnostic: Various system interlocks should be displayed on LCD screen for effective and prompt troubleshooting. E) MEMORY SYSTEM should include the following: - Image plus software 2 LCD monitors system for LIH, LIVE and stored images. Permanent image storage capacity of approx. 10,000 images. 50 temporary image storage for quick review. DVD writer to store images on CD/DVD for giving it to patients. Flicker free images on a flat screen. 32 bit image storage for excellent resolution. Image sharpening (real-time or stored images). Image rotation of 15º step. Image EMBOSS for three-dimensional relief presentation. Colorized images. Dynamic contrast control (Gray Level Stretch). Negative images (Gray Level Invert). Frames averaging for smoothing ofiImages. (Real time) 256 frames. 32 bit at 800 x 600 resolutions. Digital subtraction of images. QUAD view (4 images on monitor). Cine loop of 500 frames (Multiple cine loops can be stored permanently). Variably frame rate of 2, 5, 10, 15 & 27 frames per second for cine loop. Image orientation: Left/ Right – Top/ Bottom. Patient’s Name, operator name, hospital name, date and time display on monitor. Images can be stored in folders of individual patient’s name. Quick exploration of stored images. ON screen help mode. ON screen measurements – Length (X and Y) and Area. Area of interest marker. Contrast enhancement of area of interest. Histogram of area of interest. Facility for image printing. Text annotations and provision of removal of all text from the image. Automatic capture and storage of cine loop with cine foot switch Offset and gain adjustments for improved image quality. Thumb nail use of complete study Frame by frame review. Printing options in different formats (frames of different loops can be printed on the same sheet, 1x1, 1x2, 1x4, 1x8 formats) Frame rate selection LAN connectivity. DICOM Ready Branded processing unit Specifications: Dell Desktop Vostro-220/Lenovo 1. Intel dual core 2.5Ghz or above processor 2. Intel mother board 3. 1 GB DDR-II RAM 4. 160GB or above hard disk drive 5. DVD writer 6. 512 MB dual head VGA card 7. Specially designed integrated keyboard having feather touch keys and touch pad is provided instead of double unit keyboard and mouse F) Power requirement: The unit should be operable on Single Phase 230 V ± 10% AC, 50 Hz G) Servo voltage stabilizer of 2KVA should be provided. The system should be upgradable to DSA. G) Other Requirements: The Equipment must be European CE Certified. The company must be ISO & EN ISO certified. The unit should be approved by AERB. The company should have proven trade record in Govt. Sector. 3. Small Animal Anaesthesia The equipment should be / have Suitably designed for veterinary use (mainly for small / pet animals) Machine Easy to clean, have good finishing and the material should be rust proof. Provision of mounting bracket for mounting two vaporizers. Supplied with brand new precision Isoflurane vaporizer of premium quality which should be temperature, pressure and flow compensated. Fitted with specific breathing circuits like non re-breathing system, partial re-breathing system and total re-breathing system. Circle system fitted with fresh gas inlet, corrugated breathing tubes, reservoir bag and pressure gauge, unidirectional aspiratory and expiratory valves; pop off valves as safety device and oxygen flush system. Soda lime carbon dioxide gas absorber (capable of absorbing CO2 expired from 2 kg to 100 kg body weight). Scavenging system. Fitted with unbreakable valve dome caps. The CO2 absorber should be efficient in absorption, seal easily and be leak free seal. capable of working with vaporizer out of circle and vaporizer in the circle. Fresh gas outlet for easy use of a non re-breathing system. Oxygen flow meters of measuring capacity up to 4 liter per minute or more Fitted with low oxygen audio alarm. supplied along with Bain circuit. supplied with different sized veterinary specific induction masks having good fitting rubber diaphragms for variable sized small animals supplied with good quality cuffed silicon reusable endotracheal tubes of sizes 2-14 FR along with adaptors of suitable sizes 10 each. supplied with re-breathing bags of different sizes ranging from 0.5 . 1, 2, 3 and 5L 5 each. compatible for working with IPPV. The mobile trolley should have five legs for maximum stability (two with brakes), stainless steel body, one drawer and platform build on the top for mounting vital signs monitor. Mouth gags set of 3 to suite variety of animals Veterinary specific Laryngoscope Complete with veterinary anesthesia ventilator fitted Veterinary specific hand held monitor with SPO2, Pulse and temperature measurement Enclose catalog and list of user with telephone and Email ID The machine should have minimum 2 years warranty/ guarantee period and subsequent AMC rates may be quoted. Bain system and attachement tube 3 piece. Oxygen Cylinder-pin type-water capacity 5lit, 0.75cubmm gas capacity 4. Large animal Anaesthesia Machine with ventilator The equipment should be / have Suitably designed for veterinary use in large animal (mainly Bovine, equine and small ruminants) with inbuilt ventilator Machine should be Micro processor based electronic control system incorporates the features of current intensive care ventilators with micro processor technology. LED display of Selected respiratory variables Inverted 18 litres bellows ascending during exhalation for near to natural breathing Patient (animal) may breathe spontaneously from the bellows. Flow rate adjustable from 0-600 litres per minute with expanded range of flow rate selectivity. Extremely quite in operation. Mulitiple electrical outlets with surge protection. Ventilator should be/have -able to work on 110-220V -tidal volume adjustable (with facility for momentary switch to flush up to 15ltrs) -electronically controlled, time cycled, pneumatic powered. -adjustable frequency (minimum range 0-90 BPM) -adjustable control of inspiratory flow -have varying Inspiration /expiration ratio (range 1:1 to 1:4.5) with upgradation facility. Provision of mounting bracket for mounting two vaporizers. Supplied with brand new precision Isoflurane vaporizer (range 0%5%) of premium quality which should be temperature compensated. Should be supplied with Foal Absorber, three 30 liter bag, three 15 ltr bag compatible with machine, wye piece, and tubing required. Absorber- circuit should have pressure gauze, APL valve (allowing to make the circuit from completely closed to fully open), check valve for insipratory and expiratory flow. The CO2 absorber should be efficient in absorption. Scavenging system. 5. Veterinary Multipara monitor Supplied with 4 set of cuffed/ without cuff endotracheal tubes of 12, 14 ,16,14 , 18, 20 and 22 One set laryngoscope suitable for large animal. Alarms: Failure to cycle -visual-audible System failure - visual-audible Overpressure governor 80cm H2O Gas scavenger - 19mm port Controls Inspiratory Time-1-3 seconds Inspiratory flow - 10 -650 LPM Inspiratory Pressure - 10-70 mm H2O Rate - 2-80 BPM Pneumatic manual push button for inspiration. No need to remove the bellows for cleaning, the bellows should be cleaned in place. Oxygen cylinder: 46-47 lit water 1. Veterinary specific monitor with veterinary probes for use on variety of animals 2. Should have a battery back up of at least 2 hours. 3. Should be have SPO2, NIBP, Temperature,Respiration, ECG and Pulse rate 4. ECG cables should be veterinary specific with alligator clips 5. NIBP cuffs should be veterinary specific 6. SPO2 and pulse sensor should be easily attached to tongue and ear of the animal 7. Screen size should be minimum 10 Inches or more 8. company should provide veterinary user list Unit should have 3CH ECG : Full 7 ECG & ST Segment analysis & 12CH ECG : Full 12 ECG & ST Segment analysis. 9. Unit should have more than 13 Arrhythmia analysis & Pacemaker detection. 10. Unit should have more than 160 hours of tabular and graphic trend data save facility. 11. Unit should have facility for Drug Dose Calculation, ECG Recall, Mini Trend, ICO, Color change, NIBP STAT, NIBP VENOUS STAT, OXY-CRG, Patient information Entry 12. It must have Built in Printer 13. Unit should be fully equipped with software for canine, equine, feline, ovine, bovine etc applications. Unit should be provided with the following accessories: 14. 5 lead ECG cable: 2No. 15. ECG electrodes: 50no. 16. NIBP CUFF (As require in veterinary application of different species):3 no. 17. Temp. Probe: Rectal & skin. SPO2 Probe: 03 no each. 6. Ophthalmic instruments a) Surgical Veterinary operating Microscope 1. Should have good optics with coaxial illumination with optical light guide 2. Easy mobility 3. Should have 3 step Magnification 4. Binocular tube with 45 Degree illumination 5. Working distance 175mm and eyepiece 12,5X 6. Field of vision 43mm, 26mm and 16mm 7. Microscope floor Stand with lockable caster wheels 8. Size of base should be 600mm x 560mm 9. Should be supplied with veterinary applanation tonopen for accurate IOP measurements for variety of animals Unit should be provided with the following accessories: 1. Camera 35mm attachment 2. Assistant Binocular microscope b) Indirect Veterinary Opthalmoscoipe Synchronized Adjustment of Convergence and Parallax for high quality, stereoscopic fundus images through any pupil size. Precise selection of the observation and illumination optics for small pupils down to 1.0mm. Should have the multi-coated illumination system. Exact vertical alignment of the illumination with the observation path further minimising the reflections. PD Range: From 46 – 74mm. Phaco machine Ultrasound phacoemulsification Frequency: 28 kHz, piezo driver Control: auto-tuning (50 times/s), linear, pulsed, burst, cool micropulse phacoemulsification Power: 1-100% in steps of 1%, max. deflection 120 IJm Pulse: pulse frequency 0.5-40 Hz, pulse duration 0.25-1800 ms Counter: effective time in 0.1 s (relevant to energy delivered) Memory: 9 surgeons with 3 memory settings each I/A System Continuous irrigation function Pump system: peristaltic, linear control, proportional override Reflux: pump reverse (150 mmHg) Tubing System: single use or autoclavable 250 ml wastecontainer Memory: 9 surgeons with 2 memory settings each Performance: 0-50 ml/min, vacuum 0-600 mmHg Diathermy Frequency: 500 kHz, pulsed Power: max. 8 Watt at 500 hm HF Capsulotomy Frequency: 500 kHz, pulsed Power: max. 6.2 Watt at 500 hm, 2 ranges, automatic regulation Vitrectomy Speed: 30-1200 cuts/min Drive: electric, push/pull Power requirements Electric: 100-240 VAC, 50-60 Hz, power consumption 200 VA Dimensions & Weight Dimensions: not more than 220 x 241 (plus 50 mm for handle) x 154 mm (IN pole clamp adds 80 mm) w/h/d Weight: not more than 6 kg Linear pedal: 180 x 250 mm base plate 2.75 kg Standards IEC601-1, EN60601-1, UL 544, CE-Mark (CE-class 2B, protection class I) EMC/RFI: EN 6100-4-1, EN 50011/ EN 55081-1 EN 50082 7. Veterinary dental workstation High Speed Veterinary Dental Air Unit. This all-in-one veterinarian dental cart, performs all necessary procedures from cutting-polishing-scaling. Features: Dental Workstation Hand Pieces and silent compressor with Fibre optic Light System for high speed Hand pieces. Suction Unit – Variable suction and bacterial Filter , Automatic Hand piece activator and consumable kit Adjustable Height stainless Steel floor stand with castors ultrasonic scalar with 4 tips Foot Switch for Piezo Scaler Dental Bur Kit FG 19mm for Dogs, Dental polisher Dental Hand Instruments – 2. Sets of 14 Pieces Instrument Set with Small handle winged elevators consist of Winged Elevator 1mm, 2mm, 3mm and 4mm Root tip pick Periosteal Elevator Subgingival Curette Jaquette Supragingival Scaler Sickle Scaler Explorer / Measuring Probe Very fine periosteal elevator Extraction Forceps Tartar Removing Forceps Minnesota retractor Specialized Dental Instruments Molt, Periosteal Elevator curved deciduous elevator sml curved deciduous elevator med curved deciduous elevator Lge Small Breed / Cat right angle extraction forceps Mouth Gag Sml 5cm opening Mouth Gag Med 8cm opening Mouth Gag Lge 12cm opening60” 8. Physiotherapy instruments SHORTWAVE CUM PULSE DIATHERMY UNIT-1000W TROLLEY MODEL MAJOR TENSE (Pain Reliever)- 4 Channel Digital MINI TENSE (Pain Reliever)- Double Channel INTERFERNTIAL THERAPY UNIT WITH STIMULATOR(LCD ULTRASONIC STIMULATOR/THERAPY- MICRO CONTROLLED BASED (LCD) INFRA RED COMBINED WITH UVR WITH TIMER\ Shock wave therapy system Powerful energy range, individually selectable Reliable therapy for deep penetration areas Large focal zone, increased targeting precision Simple changeover from focused to radial applicator, wide spectrum of indications Should be usable in large as well as small animal therapy. 9. Equine surgery Table The Large Animal Table should have rust proof surface coating The table should be user friendly and can be used for equines, bovines etc. The table should be provided with 4 Vertical poles Minimum Height should not be more than 50cm. Maximum Height Should not be less than 1.10m. Should have features of Pelvic angle +/- 8 Degree and head support+/- 20” The Large Animal Table should be supplied with Anesthetic hose support for ease during anesthesia and moveable rack. The Large Animal Table should be provided with PVC padding of 90-100mm thickness. Table should have locking device for the wheels should be mounted on the frame The side panels should be steplessly control by gas hydraulic cylinders. And should be easily removable Should be supplied with 2 horizontal bars with clamps and 4 clamps for belt Should be supplied with 4 coated foam strips for head section and side panel and 4 wedge-shaped foam paddings Table should have inbuilt battery back up for atleast 20 lifts and charging time should not exceed 6 hours. The Table should also work while battery is being charged. External batteries not acceptable. The side supports and head supports should be detachable The Large Animal Surgery Table should be equipped with safety features at each corner and head support to avoid leg injury while lowering the table Should be supplied with following accessories. Large Colon Tray which can be placed caudally or laterally. Leg Support 2 leg support (Orthopaedic) – adjustable The quoting company should have supplied similar unit to some veterinary institution in India and if required should be able to provide demonstration if required Company should should provide user list along with the catalog 10.Instruments for cryosurgery 11.VIDEO GASTROSCOPE ,LAPAROSCOPE, BRONCHOSCOPE, CYSTOSCOPE & OTOSCOPE for SMALL & LARGE ANIMAL “A,”B” and “C” spray apertures An 18 mm cryochamber A 1 cm flat probe A malleable extension which makes surgery convenient in any position. Slender, fingertip trigger for maximum control and ease of viewing-also rotates easily for left-hand users. Streamlined relief valve maintains a constant operating pressure to ensure consistent and accurate freezing. Stainless Steel and brass construction for long life Cryocan-15 lit and 25 lit capacity . VIDEO GASTROSCOPE – Insertion tube outer diameter 10-10.4 mm, instrument channel 2.0-2.8 mm, working length 250-300 cm, deflection of distal tip(up – down) 180/200° – 100°, deflection of distal tip (left – right) 120° - 120°, field of view 140° or more, depth of field 2 – 200 mm, CCD chip size 1/6”, resolution- 480,000 pixels or more , two programmable control keys on handgrip & four way deflection locks. Accompanied with accessories -biopsy forceps with double action jaws, grasping forceps with double action alligator jaws, polypectomy snare , cytology brush, foreign body basket, Injection needle with retractable tip, carrying case, ETO cap, leakage tester, caps for working channel, Irrigation tube, instrument oil, bite protector ,cleaning brush, cleaning valve & video connecting cable. 2. LAPAROSCOPE Telescope forward-oblique 30° enlarged view, with outer diameter 4.5- 5 mm, length 27-29 cm and should be autoclavable. Having rod lens system and incorporated fiber optic light transmission Forward-Oblique Tele- scope 0°, enlarged view, diameter 9.5-10 mm, length 55-57cm, and should be autoclavable. Having rod lens system and incorporated fiber optic light transmission Threaded trocar , size 6 mm , length 8.5 cm with multifunctional valve & Insufflation stopcock. Telescope stopper size 11-5mm , with minimum 10 in a package. Threaded cannula , size 6 mm, working length 6.5 cm with silicon leaflet valve. Trocar with pyramid tip, size 6mm, length 8.5 cm with multifunctional valve & Insufflation stopcock. VERESS pneumo-peritoneum needle , length 10 cm, with springloaded blunt stylet and LUER-Lock Reducer 11mm to 6mm size clip-on type = 04 Grasping forceps, rotating, size 5 mm, length 36 cm with multiple teeth, fenestrated, single action jaws. Scissors with serrated double action jaws, curved with spoon blades size 17 mm , 360 deg sheath rotation, size 5 mm, length 36 cm. Dissecting and grasping forceps with long double action jaws, 360 deg rotating sheath, size 5 mm, length 36 cm. Bipolar grasping forceps, insulated, fit for coagulation, diameter 5 mm . Dissecting and biopsy forceps with single action jaws, rotating, size 5 mm, length 36 cm. Threaded trocar , size 11 mm , length 10.5 cm with multifunctional valve & Insufflation stopcock 3. CYSTOSCOPY SET – Female cystoscopy Set- Autoclavable , topline telescope forwardoblique 30° enlarged view, with OD 2-3 mm, length 17-19 cm having rod lens system. Should include cystoscopy sheath (14.5 Fr. with builtin instrument channel 5 Fr. and obturator), Grasping Forceps (flexible, long & short) ,Biopsy forceps with double spoon & oval jaws (flexible, long & short) & Stone Basket. TCI Set- Autoclavable, Forward-Oblique Tele- scope 6°, angled eyepiece, diameter 9.5 fr at tip and 13.5 fr at distal end with catheter channel of 6 fr, length 40-45 cm, incorporated with instrument port, seal and cleaning adopter. Should include TCI catheter, Grasping Forceps for large and small stones & fragments and biopsy forcep. Vagino Proctoscope For large, medium & small size animal with diameters 20 mm, 15mm & 11mm with suitable working lengths and obturator. Should include light cable, telescope bridge & biopsy forcep of suitable size. Urethro-cystoscopy Set for male dog- Flexible scope with Instrument channel: 1.2 mm. Direction of view: 0°, Angle of view: 90° , Working length: 100 cm, Outer Diameter: 3.0 mm .Following accessories should be included: grasping forcep, biopsy forcep , stone basket, carrying case , pressure compensation cap , leakage tester & cleaning brush. 4. VIDEO BRONCHOSCOPE – Insertion tube outer diameter 5.5-6.4 mm, instrument channel 2.0-2.2 mm, working length 65-70 cm, deflection of distal tip(up – down) 180°/100°, field of view 120° or more, depth of field 2 – 50 mm, CCD chip size 1/6”, resolution- 480,000 pixels or more , two programmable control keys on handgrip & four way deflection locks. Accompanied with accessories -biopsy forceps with double action jaws, grasping forceps with double action alligator jaws, polypectomy snare , cytology brush, Injection needle with retractable tip, suction Catheter, diameter 1.7-2.0mm with adopter carrying case, ETO cap, leakage tester, caps for working channel, Irrigation tube, instrument oil, bite protector ,cleaning brush, cleaning valve & video connecting cable. 5. OTOSCOPE- Otoscope , 5mm and 8.5 length with Stopcock [with integrated working channel for irrigation & instruments insertion], Autoclavable. Accompanied with accessories -biopsy forceps , grasping forcep, ear curettes, myringotomy needles, cleaning brush, aspiration needles , LED battery light source with charger, etc. 6. ENDOVISION SYSTEM Integrated, compact & portable system combining light source, camera control unit, documentation, Insufflation , Irrigation & monitor all in one . Should be compatible with all types of rigid and flexible scopes with option of direct image and video archiving (through USB ports/SD card directly), image editing, zoom functions and generation of patient report. Monitor size should be minimum 15” with light output of 50 W Hi lux. Other features like DVI video output facility and integrated 3 speed, adjustable insufflations pump are mandatory. The unit should be complete with heat resistant 300 cm long optical light cable , camera head with integrated image processing module, adopter to connect all types scopes, tubings to connect irrigation and insufflations, keyboard & foot pedal to control functions.. 7. LIGHT SOURCE- 8. XENON 100 watts with built in adopter to connect video endoscopes and Integrated pump for air insufflation & water irrigation. Max. pressure -0.5 bar , max. flow rate- 5l/min, operating temperatures- 0-40 degrees C and operating humidity-30-90%. Should be compatible for use with all types of scopes by means of a special quick adopter . Should be accompanied by one spare lamp, fibre optic light cable and adopter to connect all rigid and flexible scope . CAMERA SYSTEM- Digital, single-chip medical-video-camera compatible with all rigid and flexible scopes. Image sensor of ½” CCDchip, picture elements- 752 (H) x 582 (V) pixels per chip (PAL) , resolution minimum 450 lines (horizontal) , exposure control of 1/60 sec- 1/10000 sec, signal-to-noise ratio: > 50 dB & min. sensitivity of 3 Lux (f =1.4), Lens with integrated zoom lens of f=25-50mm . Instrument coupling device should be compatible with all rigid & flexible endoscopes with standard eyepiece. Adaptable to an operating microscope by means of a special quick adapter, camera head fully soakable for sterilization & also gas sterilizable and sterrad compatible. 9. INSUFFLATION UNIT- Fully automatic with electronically controlled gas refill. Gas flow/minute 0-20 lit , pressure 0-100mm of Hg. ; intraabdominal pressure gauze -0-100 mm of Hg .Capability for usage in laparoscopy and advance arthroscopy procedures . Have touch keys for precise pre-selection of preset values , built in optical & acoustic signals in case of overpressure. Complete with all connecting tubings, hose pipe 1.52 meter long , regulator and 4.5-5 kg CO2 cylinder. 10. HIGH FREQUENCY SURGICAL UNIT- Power Output 200 W or more with coagulation degree pre-selectable in several stages like soft & standard coagulation, voltage-controlled cutting, auto-stop & auto-start function, option of activating HF functions either via footswitch or switch on the handle. Complete with two pedal footswitch, monopolar & bipolar cords, neutral electrode of conducive silicon. 11. OTHERS LCD monitor 19" Mobile cart having 4 antistatic dual wheel, locking brakes, 1 fixed shelf . Standards & Warranty 1. Manufacturer must be EC certified for Full & Production Quality assurance. 2. Manufacturer must be ISO -13485: 2003 & ISO -9001:2008 certified for quality standards. 3. Manufacturer should quote FDA , CE,UL or BIS approved product, minimum three years from this ITB. 4. Product should have IEC safety standards where ever listed . All products should be IEC 601-1, CE certified according to MDD. 5. Manufacture should have minimum 10 installations in Government Institutions including Veterinary Universities/ICAR centres/AHD/Municipal Corporations etc with at least 5 installation in Northern India. 6. Must have a veterinary training centre in India. 7. Manufacturer should have its own full fledged Corporate office along with service centre in India. 8. All units must be covered under standard warranty for a period of 24 months from the date of installation. 9. The core operating laparoscope like telescopes, endovision ,single chip camera, light source, CO2 Insufflator, hand instruments (unipolar forcep, probe) fiber optic cable, veress needle etc should be from single manufacturer for system compatibility. No mix & match of different companies is acceptable. 1. System to lift large animal comfortably of 1000 body wt. 2. Should have a belly support cover 3. System comprises of Chain and pulley system with ease of use when working with large animals 4. should be complete with Rods and chain pulley wheel so that animal can be move from one place to others easily. 12.Large Animal Lifter 13.Large animal trolley Manually operated 2 feet height 7 feet length 5 feet width T Handle, trolley stationed on 4 wheels 6” mattress along with tarpal should be provided List of user list and catalog to be provided cum operation table 14.Large animal Shadow less lamp 15.Bovine Stomach Pump Light wt. ceiling mounted shadow less lamp with minimum 18,000 lux for large animal O.T. Pump for delivery of liquid nutrients and medicants The Dairymac Med-Eze Stomach Pump and Stainless Steel Stomach Tube assembly is a high quality unit designed by a veterinarian in the USA for ease of use, durability and rapid cleaning The Dairymac Med-Eze Stomach Pump and Stainless Steel Stomach Tube assembly is a high qualit y unit designed by a veterinarian in the USA for ease of use, durability and rapid cleaning. Large volumes of liquid can be pumped quickly with the minimum of effort. Leak proof pump Durable stainless steel construction eliminates corro sion Easy and consistent draw for delivery of product Reduces arm and shoulder fatigue Three strokes delivers 1 litre Reversible for removal of stomach contents Includes Pump and Hose Adapter Includes 2m Whiplash Stainless Steel Stomach Tube and Nose Clamp Durable 2 metre long rubber hose to connect to pump with probe Precise volume delivery 16.Theloresectoscope for teat surgery “Mini Plus” basic set with battery handle, air pump, new instruments, complete in transportation case Consisting of: Wide angle telescope, 0⁰, large image technology, OD: 3mm, WL: 14cm, standard light cable connectors **Special robust construction for use in field practice – autoclavable*Sheath, OD: 4mm, WL: 12cm for telescope T141-3000, stop including sharp trocar Inflation pump, battery operated, incl. 1.5m silicon tube LL(m), air filter, delivered without batteries Spare batteries, type:Mignon AA, 1.5VDC, package with 2 pcs., alkaline Special teat clamp, with ratchet, size 12cm, Special teat probe, Teat knife and Stenosis cutter set 4 and 3.4mm Cleaning brush small 17cm Sterilization and storing case 200x140x40mm LED endoscope light handle, mini, 1.5VDC, 90g, comp.to Dr.Fritz/Wolf, including mignon battery Aa Spare batteries, type: baby, 1.5VDC package with 2 pcs., alkaline (without picture) 17. 18.Furniture and LCD projector for Seminar Room, 19.Automatic Shoe wrapper for small animal O.T. 20.Air conditioner for PG lab 21.UPS with Battery Audience chair, sound system, smart board, podium, screen remote operated Automatic shoe wrapper for small animal O.T. with 2000 disposable shoe wrapper 1.5 tone with stabilizer starting from 130 V 2Kv UPS of reputed company 2000W along with two battery 150AH. Double story refrigerator 22.Refrigerator for PG Lab 23.Desk top, UPS with multifacility printer for PG lab Silent Generator 15 KVA preferably escott brand 23 for TVCC LED Monitor 24 LED monitor of 36 inch. Fire Extinguisher Portable, Wall mounted, 9 kg capacity, Body material MS, 25 Material ABC, squeeze grip, suitable for all classes of fire. Ambulance Van Should be suitable for animal ambulation along with all 25 26 CCTV SET For O.T. 27 Mobile Large Animal Carrying System facility like –vital parameter monitoring machine, oxygen therapy. 4channel videooutput, support ich, IP camera, 1 SATA port upto 4TB, 2 USB ports, 1RJ45, 1RS 485, HDMI/VGA, Mobile software, IR Dome Camera, 1/3” sony ccd sensor, 700 Tvt, 0.01 lux/0lux, 3.6mm lens, 24leds, upto Mtrs, camera holder, cctv 3+1, installation and warranty. Fuel operated Mobile Large Animal Carrying System • Should have 3000kg load capacity • Should have 500 mm load center • Should have 2 small front & 2 large tyre Lifting or pulling Large Animals stuck in mud or ravines. Mast Details • Should have wide view mast • Should have fork height 3000mm • Should have 3000 kg load capacity • Should have 1800-2200mm lowered height • Should have 180 mm approx. free lift. Attachment • Should have Shovel attachment • Size of shovel should be 1320 x 1225 x 710 mm • Should have crane attachment with 1200 mm length • Should have attachment of vertical G.I. shaft with pullies or hooks at two end and in center for lifting of animals • Should have three sets of slings for lifting of large animals 28 Metal Detector Instruments should be sufficient powerful to detect any foreign metallic object in large ruminant stomach.