Prentex Pressure Aging Vessel Technical Specifications Meeting all AASHTO, ASTM, & EN14769 Standards with ease & operational efficiency. The light-weight, compact unit demonstrates the excellence in engineering design and quality. The 9500 PAV is the only unit designed for easy access & operation from any STANDARD 30" laboratory countertop. 100% USA manufactured, a locally supplied air source (bottled/compressed air) completes the process needed for aging bitumen. Pressure Vessel: All-Stainless Steel vertical vessel with hinged lid; Designed, Manufactured, Tested & Stamped in accordance with ASME Boiler and Pressure Vessel Code, Section VIII, Division 1 for 350 psig @ 300oF [2.45 MPa @ 148oC] System Controller: [1] Touchscreen operator interface [2] Data Logging: All Data downloads during the aging run via USB drive: Temperature (wall & air), Pressure, Elapsed time, Temp Error Time, Pressure Error Time, & Power consumption [3] Alarms: Timing [Audible and visual]: [a] Temperature out of tolerance by more than ±0.5oC in excess of 60 minutes; or failure to achieve reheating and pressurization within two (2) hours after loading specimens [b] Pressure out of tolerance by more than ±0.5oC for (5) minutes; OR, Failure to achieve initial pressure of at least 2.00MPa Alarms: System [Visual only]: [a] Pressure >design limit of 2.45MPa or < set-point by more than 0.10MPa. [b] Over-temperature condition [in excess of 150oC] with power cut off to oven. PAV Operation: Digital Indication & Control Accuracy ±0.03MPa of set-point PAV Operating Pressure: 0.00MPa to 2.10 MPa [304.6 psi] Pressure Measurement via Solid-state pressure transducer with: Resolution: 0.5 psig [0.003MPa] & Accuracy: 0.5% (±0.01Mpa) Range: 0-500 psig [0-3.45 MPa] PAV Operating Temperature Range: Automatic Lab Standards: 90.0oC, 100.0oC, & 110.0oC & 85.00C Research range: 60.0oC to 120.0oC Temperature Measurement: Precision Platinum RTD, 0.1oC resolution: Accuracy ±0.1oC Temperature Control PID digital indication and control: Accuracy Set-point ±0.3oC Temperature Uniformity ±0.5oC of Aging Temperature Set point when pressurized Over-temperature Protection 150oC Limit Shut-Down Switch Timing System Clock-controlled microprocessor, 0.1% accuracy on all functions Timing Displays: [1] Elapsed Aging Time [from pressurization]; [2] Cumulative time out of temperature tolerance [±0.5oC]; [3] Cumulative time out of pressure tolerance [±0.5oC] Air Regulation and Inlet System The Model 9500 PAV is furnished with regulator on domestic unit and ALL units ship with adaptors for standard industrial compressed air cylinders, 6’ foot stainless over braided connecting hose with female quick-disconnect, and mating male quick-disconnect on rear of PAV System Cabinet. Pressure Safety Release Spring-Loaded Relief Valve calibrated to release pressure at 350 psig installed PAV Exhaust Air muffler supplied installed; Adaptor for venting provided but not factory installed. Certification of Calibration Factory calibration furnished with N.I.S.T. traceable Certificate of Calibration. Air Requirements: Local laboratory or commercially furnished bottled/compressed air is required to complete the PAV process. The required air pressure is 2.2 - 2.4 MPa (22 - 24 bar). Power Requirements / Consumption: Prentex Model 9500A = 100-125v AC, 50-60Hz, 10A (Domestic) Prentex Model 9500E = 208-240v AC, 50-60Hz, 5A (Export) Cabinet: Stainless Steel construction - Dimensions: 25½ “x 17" X 17" high; Requires only 31" overhead clearance for cabinet lid opening Weight: 170 pounds on counter (Ships @ ~220LBS) Operator’s Manual: Includes operation, maintenance, calibration procedures, and basic troubleshooting. Warranty: One (1) year parts and labor Technical Support: [1] Available via phone, fax or e-mail [2] Live phone support available Monday - Friday 8:30-4:30 [Central Time Zone]