Whole Doc - Planning

advertisement
Ref: Unit S, Gun Hill Trading Estate, Ipswich Road, Dedham, Colchester CO7 6HR
Planning Application no: 150868
Specification
Dimensions
Length
Width
Eaves height
= 24 metres
= 12 metres
= 4.3 metres
Ridge height
Roof Pitch
Number of bays
= 5.908 metres
= 15 degrees
= 4 @ 6 metres
Length/width/eaves dimensions are to inside of external cladding profile - steel frame and side rails/purlins are
within these dimensions therefore clear height/floor area available will be less.
Steelwork
4 No. portal frames with roof & vertical bracing to 1 No. bay, 1 No. gable post and 8 No. door posts.
Included are plated erection bolts and the supply to site only of black holding down bolts and washers.
Holding down bolts and washers to be cast in concrete foundations by others with timber bolt templates & tubes /
cones supplied by others. Holding-down bolts etc. to be positioned in accordance with NSB foundation plan. Final
grouting-in of bolts and stanchions is also by others.
Finish
All structural steelwork to be hot-dip galvanised as standard.
Cold rolled
Cold rolled galvanised purlins, rails and eaves beams, complete with the necessary anti-sag bars.
Cladding
Roof Cladding
Wall Cladding
= AS35 – 120mm Composite LPC PIR
= AS35 - 80mm Composite LPC PIR
AS30 profile sheets are single skin (0.5mm gauge walls & 0.7mm roof). AS35 composite sheets are an insulated,
double skin panel. Both systems have a plastisol-coating to the exterior face. Note: self-build kit does not include
silicone sealant for use on drip flashings, guttering etc. Insulated buildings may also require rockwool insulation to
fill voids at corners, barge & eaves.
Skylights
= 8 No. Full Length AS35 – 120mm Skylights Triple Skin
4 No 1.2m Length AS35 – 120mm Skylights Triple
Skin
(2 No. per bay - approx. 16 % roof area)
( 1 no per bay – approx. 1.5% of wall area)
Single skin AS30 skylights may be prone to condensation in certain conditions.
Anti-condensation Barrier
= Not required
Condensation may form on the underside of single skin steel sheets without a condensation barrier. Not required
on AS35 composite panels and cannot be applied to skylights.
Ridge Fillers
Base Fillers
= Included
= Not required
Foam fillers are used to close off the corrugation gaps in the cladding, preventing ingress of wind & weather and
helping to keep out vermin. Base fillers only apply to concrete slabs laid in accordance with our drawings.
Rainwater goods
Black PVC gutters and downpipes Registered in England Number:
711612
Registered Office: 3 Hardman Street, Manchester, M3 3HF
Colours
Roof Plastisol-coated
Wall Plastisol-coated
Flashings Colour
Colour Gooswing Grey RAL 10A05
Colour Black
RAL 9005
Colour Black
RAL 9005
Sectional Slide Over
Doors
2 X 3.660m wide by 3.660m high insulated sectional slide over door, Colour – Green RAL 6010
(Clear Opening Dimensions)
These are plastisol-coated steel, insulated sectional slide over doors. Electrical conduit and wiring is
excluded. All motors are pre-wired prior to site installation and it will be necessary for a switched outlet to
be installed (by others) for our motor to be plugged into. Your electrician is required to set final limits and
braking system. The doors MUST NOT be used until the limits are set. The power supply should be
400/440 volts, 3 PHASE, Neutral and Earth. Handing of motor/manual hand chain (looking from inside the
building outwards), outlet position and any optional extras required are to be confirmed prior to placing an
order.
Personnel Doors
4 X Personnel Access Door 0.99m wide by 2.095m high, Colours - Green RAL 6010
Our steel doors are high security doors with standard lever handles, euro profile multi-point locking and a
painted finish from BS or RAL colour range. A personnel access door is highly recommended where roller
doors with a clear opening height of greater than 2.1m are used. Alternative / additional furniture available
is on request.
Foundation Pads
See Structural Calculations pages 41 – 47
Concrete floor
150mm thick fibre reinforced concrete floated finish on minimum 100mm compacted crushed concrete
Registered in England Number: 711612
Registered Office: 3 Hardman Street, Manchester, M3 3HF
Download