Analysis in ProcESS Xuan Wang Department of Chemical Engineering Department of Metallurgy and Materials Engineering 23/01/2013 Table of content • Introduction • ICP-MS Introduction Principles Influence Sample preparation AAS FT-IR PerkinElmer GC lab Mercury Analyzer Contact Angle Analyzer • • • • • 2 Introduction ProcESS --- Process Engineering for Sustainable Systems Research focuses on: •Process intensification •Solid waste treatment •Surface and interphase analysis •Advanced separation processes using membrane technology Various analytical equipments: ICP-MS, AAS, FT-IR, GC, Mercury Analyzer, Contact Angle Analyzer… 3 ICP-MS Inductively Coupled Plasma -Mass Spectrometry Producer: Thermo Scientific Type: X series Contact: Michèle Vanroelen (michele.vanroelen@cit.kuleuven.be) Advantages: •Quantitative and semi-quantitative analysis •Detection limits at or below ppt level for much of the periodic table •8 orders of magnitude analytical range •High productivity •Isotopic analysis 4 (PerkinElmer) Remark: Method Detection Limit (MDL) is generally 2-10 times more than Instrumental Detection Limit (IDL) 5 PerkinElmer, Inc RF Load Coils ICP Torch Principles Argon Plasma Ionization of atoms At certain time, only ions with one certain mass-to-charge ratio can pass through and be detected. Solid Atoms Ions Aerosol Gas (PerkinElmer) mass spectrometer Cones Schematic representation of a quadrupole ICP- MS 6 Influence • Matrix effects: signal suppression or enhancement caused by overloading of plasma, cooling effects, changes of ionization, blockage of cones, change of ion sampling, etc. Remedy: internal standard (Be, Ga, In, Tl). Residual signal (rlative to the signal in 0.14 M HNO3) for several elements present in 0.5 M H2SO4 matrix as a function of the mass number of the nuclide. (Vanhaecke F., Vanhoe H., Dams R., Vandecasteele C. , Talanta, 1992, 39) 7 Influence • Spectral interferences: interferences between ions with similar atomic mass. Remedy: Use of HNO3 Select isotopes (65Cu instead of 63Cu (ArNa+)) Mathematical correction Modify sample preparation (USGS) 8 Influence • Cone blockage The small orifice (~ 1mm) on the cones can be blocked if too much total dissolved solids (TDS) in the solution. This can cause decreased sensitivity and detection capability Remedy: diluted feeding solution (TDS no more than 0.2%) Partially blocked orifice (Kym Jarvis. Presentation for Nuclear Spectrometry Users Forum, May 2005) 9 Sample preparation Preparation •Sample digestion Three acids digestion Microwave digestion Lithium metaborate fusion digestion •Sample dilution •Standard preparation 10 Sample digestion • Three acids digestion 0.1 g finely ground sample added in Teflon beaker with heating on the bottom and lid on the top Three acids: - HNO3: oxidation, dissolving oxides and hydroxides - HClO4: oxidation, dissolving organics - HF: dissolving silicate are added, 5 ml each, by sequential order until the previous one boiled down. If the sample is not completely dissolved, more cycles of the process (without HClO4) are needed until the complete dissolution of sample. Caution: highly corrosive acids applied and protection needed 11 Sample digestion • Micro wave digestion: Acid digestion carried out in microwave transparent inert material vessels, where pressure is introduced High temperature (260-300 °C) High digestion quality Reduced acid consumption Reduced digestion time (20-60 minutes) 12 Sample digestion • Lithium metaborate fusion digestion: Thoroughly mix 0.1 g finely ground sample with 1.0 g of lithium metaborate (LiBO2) Put the mixture in a graphite crucible and insert crucible into an oven at 1000 °C for 15 minutes Pour the melt mixture into 100 ml 5 vol% nitric acid solution Stir at least 15 minutes until all solid dissolved then filtrate the solution for dilution and measurement 13 Sample preparation • Sample dilution: The digested solution normally need to be dilute Concentration not larger than 1000 ppb Concentration not lower than detection limit Normally 2 vol% HNO3 is added • Standard preparation: Chose concentration of elements according the element concentration in diluted sample Addition of internal standards (e.g. Be, Ga, In and Tl) 3 or 5 calibration points, including one blank 14 AAS • Atomic Absorption Spectroscopy Principle: absorption of EM-radiation characteristic for electron transition in the outer shell of an atom of an element. (http://web.vscht.cz/poustkaj) 15 AAS • Measurement of almost all metals, metalloids and some non-metals (B, Si, P) • Sample: - Solution in diluted acids - Diluted biological fluids - Suspensions of solid samples (slurries) • Flame AAS (in CIT): measurement of higher concentration (10-100 ppm) – high temperature flame (N2O) • Measurement time 3-10 seconds • Contact: Michèle Vanroelen (michele.vanroelen@cit.kuleuven.be) 16 FT-IR • Fourier Transform InfraRed • (with diamond ATR) Principle: absorption of IR-radiation results in changes of vibrational energy of molecules. (Thermo Nicolet, co.) 17 FT-IR • Identification of unknown pure (organic) compounds • Identification of functional groups • Sample: liquid, solid (in solution), solid. • Fast measurement, in a matter of seconds • Less suited for quantitative analysis, detection limits around 2 % Contact: Christine Wouters (christine.wouters@cit.kuleuven.be ) 18 PerkinElmer GC lab •GC-MS GasChromatograph Mass Spectrometry Analysis of PCBs, phenols, trizaines, organophosphorus and organochlorine pesticides, PAHs, mono-aromatic hydrocarbons. •GC-FID/ECD GasChromatograph Flame Ionization Detector and Electron Capture Detector Analysis of PCBs, phenols, organochlorine pesticides, mono-aromatic hydrocarbons, aspecific solvents, mineral oil, volatile organic acids. 19 PerkinElmer GC lab •GC-FID GasChromatograph Flame Ionization Detector Analysis of phenols, mono-aromatic hydrocarbons, aspecific solvents, mineral oil, volatile organic acids. •GC-FID/NPD GasChromatograph Flame Ionization Detector and Nitrogen Phosphorus Detector Analysis of phenols, triazines, organophosphorus pesticides, mono-aromatic hydrocarbons, aspecific solvents, mineral oil, volatile organic acids. Contact: Christine Wouters (christine.wouters@cit.kuleuven.be ) 20 Mercury analyzer • Design for all types of sample: -Environmental samples (water, soil, plants, etc) -Human samples (hair, blood, urine, etc) •Vapour generation technique (remove most chemical interferences) (not operational yet by the moment, part of RARE3 project) •Atomic fluorescence spectrometry (mercury analysis down to ppt level) •Contact: Tom Van Gerven (thomas.vangerven@cit.kuleuven.be ) 21 Contact Angle Analyzer KRÜSS Dsa10-MK2 Contact: Bart Van der Bruggen (bart.vanderbruggen@cit.kuleuven.be ) 22 Contact • ICP-MS • AAS Michèle Vanroelen (michele.vanroelen@cit.kuleuven.be) • FT-IR • PerkinElmer GC lab Christine Wouters (christine.wouters@cit.kuleuven.be ) • Mercury Analyzer Tom Van Gerven • Contact Angle Analyzer Bart Van der Bruggen (bart.vanderbruggen@cit.kuleuven.be ) (thomas.vangerven@cit.kuleuven.be ) 23 Many thanks! 24