WELCOME BASICS OF VIBRATION VIBRATION CHARACTERISTICS OF VIBRATION SIGNAL AMPLITUDE FREQUENCY PHASE ORBIT TYPES OF VIBRATION PICK UP PROXIMITY PROBE VELOCITY PICK UP ACCELEROMETER CRITERIA FOR SELECTION OF VARIOUS TYPES OF VIBRATION PICK UP PROXIMITY PROBE SHAFT VIBRATION MEASUREMENT KEY PHASER MARKER SHAFT CENTRE LINE POSITION BEST SUITED FOR 1 TO 500 HZ VELOCITY PICK UP FOR BEARING AND STRUCTURAL VIBRATION BEST SUITED FOR 10 TO 1000 HZ CRITERIA FOR SELECTION OF VARIOUS TYPES OF VIBRATION PICK UP ACCELEROMETER FOR HIGH FREQUENCY RANGE BEST SUITED FOR 1000 HZ ONWARDS UNITS OF VIBRATION (A) DISPLACEMENT MICRONS, PEAK TO PEAK MICRONS, 0 TO PEAK MICRONS, RMS (B) VELOCITY MM/SEC, 0 TO PEAK MM/SEC, RMS (C)ACCELERATION M/SEC2, PEAK M/SEC2, RMS G, PEAK G, RMS UNITS OF VIBRATION Average RMS 0 - Peak Peak - Peak RMS = 0.707 x (0-Peak) Average = 0.637 x (0-Peak) Peak to Peak = 2 x (0-Peak) Y SHAFT ORBIT X Proximity Probes INSTRUMENTS FOR VIBRATION MEASUREMENT VIBROMETER VIBRATION ANALYSER FFT ANALYSER TIPS FOR MAKING VIBRATION DATA MORE USEFUL FOR ANALYSIS LOCATION OF VIBRATION PICK UPS TO BE INDICATED LOCATION OF PHOTOCELL TO BE INDICATED DIRECTION OF ROTATION SHOULD BE INDICATED KEY PHASER MARK ON ROTOR POSITION TO BE INDICATED AXIAL VIBRATION PHASE LOGGING MUST HAVE DIRECTION INDICATION NAME OF VIBRATION ANLAYSER SHOULD BE INDICATED VIBRATION UNITS TO BE INDICATED TIPS FOR MAKING VIBRATION DATA MORE USEFUL FOR ANALYSIS WHILE GIVING CONTROL ROOM VALUES, SPECIFY VIBRATION UNITS AND LOCATION OF THE PICKUPS THE VIBRATION MUST BE MEASURED BY PORTABLE VIBRATION METER NEAR CONTROL ROOM PICKUP FOR VARYING THE CORRECTNESS OF CONTROL ROOM MEASUREMENT PICK UP SHOULD NOT BE MOUNTED LOOSE BRACKET FOR EXTERNAL SHAFT VIBRATION PICKUP SHOULD BE STIFF ENOUGH NOT TO PRODUCE AMPLIFICATION / RESONANCE TIPS FOR MAKING VIBRATION DATA MORE USEFUL FOR ANALYSIS FOR CORRECT TRENDING OF VIBRATION READINGS, SAME LOCATION SHOULD BE USED FOR ALL PERIODIC MEASUREMENTS REASONS OF VIBRATION IF THE MEASUREMENT IS HEALTHY, FOLLOWING MAY BE THE REASONS OF VIBRATION PROBLEM UNBALANCE MISALIGNMENT LOOSENESS PIPE PULLS SHAFT CATENARY / BEARING LOADING RESONANCE UNEQUAL FLOW PATH CLEARANCES RUBBING REASONS OF VIBRATION SHAFT BOW OIL / STEAM WHIRL DEVIATED OPERATING PARAMETERS DEFECTIVE BEARING / ASSEMBLY OF BEARING VIBRATION TRANSMITTION FROM OTHER SOURCE GEAR INACCURACIES CASING DISTORSTION CAVITATION STEPS FOR RESOLVING THE VIBRATION PROBLEM ACCURATE MEASUREMENT OF VIBRATION DATA COLLECTION OF OPERATING PARAMETERS STUDY OF HISTORY OF VIBRATION BEHAVIOUR / OVERHAULING REPORTS / RECURRING PROBLEM FACED INTERACTION WITH O&M PERSONNELS COLLECTION OF DETAILED VIBRATION BEHAVIOUR AT VARIOUS CONDITIONS OF OPERATION LIKE NO LOAD RUN, RUN UP, RUN DOWN, WITH AND WITHOUT EXCITATION, PART AND FULL LOAD OPERATION ETC. VIBRATION ANALYSIS TO NARROW DOWN THE REASONS OF HIGH VIBRATION STEPS FOR RESOLVING THE VIBRATION PROBLEM FORMULATION OF ACTION PLAN (SHORT TERM / LONG TERM) IMPLEMENTATION OF ACTION PLAN RESPONSE OF MACHINE AFTER IMPLEMENTATION OF ACTION PLAN FRESH VIBRATION ANALYSIS, IF THE PROBLEM PERSISTS IMPLEMENTATION OF NEW ACTION PLAN THE CYCLE OF VIBRATION ANALYSIS AND IMPLEMENTATION OF ACTION PLAN CONTINUES TILL THE VIBRATION PROBLEM IS SATISFACTORILY RESOLVED KNOW YOUR MACHINES KNOWLEDGE OF BEHAVIOUR FOR SIMILAR TYPE OF MACHINES VIBRATION PRONE AREAS INFLUENCE OF PARTICULAR OPERATING PARAMETER INTERNATIONAL STANDARDS ON VIBRATION ISO 10816 BEARING VIBRATION ISO 7919 SHAFT VIBRATION THERE ARE THREE LIMITS IN INTERNATIONAL STANDARDS LIMITS FOR NEW MACHINES ALARM LIMITS TRIP LIMITS RECOMMENDED LOCATIONS OF VIBRATION MEASUREMENTS ON BEARINGS AS PER ISO RECOMMENDED LOCATIONS OF SHAFT VIBRATION MEASUREMENTS AS PER ISO Measuring Amplifier Measuring Amplifier 45O L PROXIMITY PICK-UP 45O SHAFT VERTICAL R OR L SHAFT R HORIZONTAL THANK YOU