Micron Transformers Presented by Richard Lussier and John Levine Levine Lectronics and Lectric Types Of Transformers • • • • • Impervitran Globaltran LVGP Buck Boost Power Supplies Impervitran • • • • • • • • Made in USA First Encapsulated Transformer 20 Year Warranty Secondary Fuse Clips where applicable Optional Primary Clips ( Factory / Field) Touch Safe Terminal Covers 14 Standard Primary / Secondary selections 105 / 130 / 180 degree c rise IMPERVITRAN • Ratings UL CSA 50 – 60 HZ Rated • 25VA – 5 KVA open type • Multiple Primary / Secondary values • Center tap secondary available • Primary Voltages up to 600V AC • Secondary Voltages 24V AC • Custom Transformers Globaltran • • • • • • • • • International Transformer CE Labeled 50 – 60 HZ Ratings Meets or exceeds IEC-742 Standard with Touch Safe Terminals IP20 20 Year Warranty 7 Standard Pri / Sec Offerings 50 VA – 750 VA ratings Customs Available LVGP Low Voltage General Purpose • Dry Type Enclosed Transformers • Single Phase / Three Phase Ratings • Indoor / Outdoor Ratings with optional drip hoods • 60 HZ Rating only • Type 1 or 3R Enclosure Rating Available LVGP Single Phase • • • • • • Seven Standard Voltage Patterns Voltage RangePri 120 to 600V Secondary 120 – 240V AC KVA Range 0.5 KVA – 167 KVA Transformers 2 KVA and Below Copper Transformers 3 KVA and Above Aluminum LVGP Three Phase • • • • • • 8 Standard Voltage Ranges Voltage Range Primary 208V – 600V Secondary 120V – 480V KVA Range 3 KVA – 750 KVA Transformers 2 KVA and Below Copper Transformers 3 KVA and Above Aluminum Buck Boost Transformers • Buck Boost Transformers are used to convert a lower or higher voltage to a more suitable voltage. • Ex. 230 to 208V Buck • 240 to 277 Boost • Range is about 20 % voltage change • Both Single and Three Phase Conversations • Wired in Autotransformer configuration • • • • • • • • • Power Supplies UL/ CUL/ UL508 / CE 5 Year Warranty Voltage Input 85V – 264VAC Secondary Voltage 12/24/48VDC Wattage 60 – 480 Current 2.5 – 13.3 amps Operating Temp - 10 Deg – 60 deg C DIN Rail Mounting Power Boost 25% for 5 sec Power Supply • • • • • • First IP67 Power Supply on Market UL Recogonized, CUR, CE Voltage 90 -264 V Primary 24 VDC Secondary 2 or 4 amp version 50 – 100 watt Micron Transformers Capabilities Module Product Capabilities • • ENCAPSULATED CONTROL TRANSFORMERS IMPERVITRAN DESIGN -- Part numbers beginning with B VOLTAGE CAPABILITY – Primary 100V through 600V – Secondary 5V through 240V • VA RANGE – 25VA through 5000 VA • TEMPERATURE CLASS 105, 130 & 180 • Terminations available – 4-terminal block-standard – 6-terminal block-optional – Fastons-optional • Installed fusing capabilities – Type "K" (13/32 x 1-1/2) secondary clips (standard for most part numbers) – Class "CC" primary fuse block – Type "M" (9/16 x 2) secondary clips – Type "Q" (1/4 x 1-1/4) secondary clips – Thermal fusing – Custom options available Product Capabilities III LOW VOLTAGE GENERAL PURPOSE (LVGP) and BUCK-BOOST 600 Volt Class Part numbers starting with G, J • Single phase encapsulated and ventilated from 50VA through 167KVA • Three phase encapsulated and ventilated from 3 through 750KVA Features & Benefits Features ImperviTRAN designs feature Class 105C, 130C & 180C encapsulated construction. Benefits Customers can choose the design system that best serves their needs. Features ImperviTRAN designs feature molded terminal block construction. All have provision for SafeTouch IEC-529/IP-20 rated termination covers. Benefits Molded terminal blocks provide superior strength, electrical insulation and ease of wire termination. IEC-529/IP-20 terminal covers provide unsurpassed product safety. Features Provision for secondary fusing is standard on most designs utilizing molded terminal blocks. Provision for primary fusing available on most designs. Benefits Saves valuable panel space and simplifies panel assembly. Features GlobalTRAN designs are approved to IEC-989, 742 or 61558 and carry the CE mark. GlobalTRAN is designed in ImperviTRAN construction. Benefits Meets the requirements of the international Low Voltage Directive 72/73/EEC. GlobalTRAN can be designed to virtually any customer application. Features Unprecedented 20 year warranty on control Transformers (600 volt class). Benefits Worry free performance for the life of the application. Features General purpose enclosed units available in a wide selection of encapsulated or ventilated, tapped and untapped configuration. Benefits Allows for one of the widest product choices in the industry. Micron Transformers Part number module ImperviTRAN, ValuTRAN, EconoTRAN • All ImperviTRAN P/Ns begin with “B” – B050BTZ13JK • All obsolete ValuTRAN P/Ns begin with “V” – VF1K0BTZ13JK • All obsolete EconoTRAN P/Ns begin with “E” – EF1K0BTZ13 GlobalTRAN • GlobalTRAN is built in ImperviTRAN construction. • All GlobalTRAN P/Ns end in “GA,GAF or GAH” – B050-2001-GA – B150-2004-GAF – B1K0-2008-GAH Frequency • ImperviTRAN designs are rated at 50/60 Hertz (Hz). • A 50Hz rated device can operate at 60Hz but a 60Hz device can’t operate at 50Hz. – A device can always operate at a frequency higher than nameplate. • Some P/Ns include an “F” or “N” after the initial letter. – VF1K0BTZ13JK – BN1K0BTZ13 – HN1K5G1519P • The “F” = 50/60Hz. • The “N” = 60Hz. Exceptions • P/Ns that date back before 1983 – May include a letter as the 2nd or 3rd character. This identified the customer. – BRQX040JCBXT7-50 – May include an “X” as the 2nd – 4th character. This identified special construction. – BX100MBT13 – BRQX040JCBXT7-50 Temperature Class • An ending “F” denotes Class 130°C. • B150BTZ13JKF – Internally, Micron may replace with a leading “M”. • M150BTZ13JK • An ending “H” denotes Class 180°C. • B1K5BTZ13JKH – Internally, Micron may replace with a leading “N”. • N1K5BTZ13JK VA/KVA • VA = Volts X Amps • KVA = VA X 1000 • The numbers following the initial letter in the P/N = VA size. – – – – B050BTZ13JK (50VA) B100BTZ13JK (100VA) B100-2003-GA VF1K0BTZ13JK (1000VA or 1KVA) Primary Voltages • The letters following the VA size = primary voltage. – B050LP7JK • letters and representative voltages are: – – – – B = 230 L = 120 M = 208 Q = 277 P = 240 R = 380 T = 460 U = 480 W = 575 • A “Z” as the last letter = transformer can handle a voltage range 5% of nominal voltage (triple rated). – B050BTZ13JK • 220/230/240 – B050WZ13XK • 550/575/600 – B1K0BTWZ37XKH • 220/230/240, 440/460/480, 550/575/600 Exceptions • The “Z” is deleted on triple rated P/Ns that would be longer than 12 characters. – B100MBT713XK • All voltage reference is deleted from serialized P/Ns. – B150-0484-1 – B150-2004-GAF Secondary Voltages • The numbers following the primary voltage = secondary voltage – B050LP7JK – B050MQ15XK – B050MBT713XK B050PU1519JJ EF1K0BTZ1318 • letters and representative voltages are: – 7 = 24 – 13 = 115 – 15 = 120 18 = 230 19 = 240 34 = 110/220 Exceptions • All voltage reference is deleted from serialized P/Ns. – B150-0484-1 – B150-2004-GAF Accessories jumpers fuse clips covers Jumpers • Jumpers are used to connect terminals together. Common uses are to derive either 230 or 460 from a series/parallel wound device or sometimes to connect fuse clips on the terminal block. • Jumpers are denoted by a “J” as one or both of the final 2 characters on the P/N. – B050 BTZ13JK – B050PU1519JJ Exceptions • Jumpers are included but not denoted in the following P/N constructions: EconoTRAN EF1K0BTZ13 GlobalTRAN B100-2003-GA • The letter “T” as one of the last 2 characters denotes an optional Stack ‘n Store (J3) jumper. – B100BTZ13TK Secondary Fuse Clips • Virtually all ImperviTRAN products include mounted fuse clips for a 13/32 X 1-1/2 midget fuse on the secondary side. • This is denoted with a “K” at the end of the P/N, –1 on a serialized P/N & “F” on GlobalTRAN. – – – – B050BTZ13JK B050MQ15XK B050-0482-1 B050-2001-GF • Mounted fuse clips for ¼ X 1¼ or 9/16 X 2 type secondary fuses can be ordered by substituting the “K” with the following letter: – Q = ¼ X 1¼ – M = 9/16 X 2 B100BTZ13JQ B100BTZ13JM • A “-3” at the end of a serialized P/N= no fusing capability. Primary Fuse Blocks • Class ‘CC’ style & midget style fuse blocks can be ordered as a factory installed option on ImperviTRAN & ValuTRAN. • The letter “R” as the next to last character = a class ‘CC’ fuse block. – B100BTZ13RB • The letter “N” as the next to last character = a midget style fuse block. – B100BTZ13NB • A “–8” on a serialized P/N = class ‘CC’ fuse block. – B100-0483-8 • The letter “K” at the end of a GlobalTRAN P/N = class ‘CC’ fuse block. – B100-2003-GK • The letter “G” at the end of a GlobalTRAN P/N when secondary fusing is also ordered = class ‘CC’ fuse block. – B100-2003-GG Exceptions • P/Ns dating before 1983 – Will not include characters for jumpers or fuse clips (although installed). – B100BTZ13 – May include a customer identifier after the secondary voltage identifier. – BX050ER7-FE – May include an identifier calling out a design feature, ie: CT = Center Tap – B050L7-CT Safetouch Covers • Safetouch covers are included with all GlobalTRAN products. • Safetouch covers are available for all products that utilize the ImperviTRAN design.