PC_F Physics Line - 1
Personnel et confidentiel
Starting with infrared thermography
Thermography interests
• To save on the invoices of electricity by improving the output of the electric installations
• To locate the energy losses
• To avoid the stops of production, machine breakings
• To eliminate the fire hazards
• To decrease the insurance premium
PC_F Physics Line - 2
Personnel et confidentiel
Why thermography is it so useful ?
3 essential advantages:
•Non-contact measurement
•Method with two dimensions
•Real time method
PC_F Physics Line - 3
Personnel et confidentiel
Why use thermography?
•Better safe than sorry
That should be our motto!
•Infrared thermography: a powerful diagnostic tool for preventive maintenance
Enables corrective action to be taken prior to costly breakdowns
PC_F Physics Line - 4
Personnel et confidentiel
Thermography application
•Electrical maintenance
•Mechanical maintenance
•Building thermics
•Industrialisation/manufacturing
•Research and Development
PC_F Physics Line - 5
Personnel et confidentiel
Electrical maintenance
PC_F Physics Line - 6
Personnel et confidentiel
Thermography applications
•Main use: electrical maintenance
•Objective:
Classification of faults in order of seriousness
Necessary to assess
•Recommandations
PC_F Physics Line - 7
Personnel et confidentiel
Electrical maintenance
Poor connections
Overloads
Phase unbalance
Faulty contacts
….
Material deterioration
Production stoppages
Operating losses
Fires
….
PC_F Physics Line - 8
Personnel et confidentiel
Electrical maintenance
•Role of the camera:
Provide decisive elements enabling:
Identification of work to be undertaken
Facilitate maintenance, save time and increase safety
PC_F Physics Line - 9
Personnel et confidentiel
Electrical maintenance
•Methodology
Scanning of the entire electrical installation when the elements are in normal load
Spatially located anomalies, possible calculation of overheating
Definition of extent of emergency and management of anomalies
PC_F Physics Line - 10
Personnel et confidentiel
Electrical maintenance
BT/TBT electricity
Faulty fuse contact Faulty connection
PC_F Physics Line - 11
Personnel et confidentiel
Electrical maintenance
BT/TBT electricity
Faulty connection
Fuse holder connection
PC_F Physics Line - 12
Personnel et confidentiel
Cable head
Electrical maintenance
BT/TBT electricity
PC_F Physics Line - 13
Personnel et confidentiel
Incorrect connection screwdown
CA 6250 : Micro-ohmmeter 10A
measure of continuity of the masses
measure of state of surface and plating,
measure of the quality of the contacts (switches, relay),
measure of the resistance and the resistivity of cables,
check of good mechanical connections,
measure of the resistance of the windings and\or the warm-up of motors and transformers,
...everywhere it is necessary to control the quality of the connections, the contacts and the surfaces.
PC_F Physics Line - 14
Personnel et confidentiel
Electrical maintenance
BT/TBT electricity
PC_F Physics Line - 15
Personnel et confidentiel
Wrongly calibrated fuse
PC_F Physics Line - 16
Personnel et confidentiel
Electrical maintenance
BT/TBT electricity
PC_F Physics Line - 17
Personnel et confidentiel
Unbalanced load
CA 8230
Série F0X
Power
& Energy
Active
Reactive
Apparent
Harmonics single /
Balanced three-phase
F09 Clamp
Power measurement
Active
Reactive
Apparent
TRMS
CA 8334
Power & Energy
Harmonics single / three-phase
Recordings
Transient captures
Trigerring on alarms…
PC_F Physics Line - 18
Personnel et confidentiel
Electrical maintenance
HTA/HTB electricity
Inspection of high voltage lines
PC_F Physics Line - 19
Personnel et confidentiel
Contact problem with selector
Electrical maintenance
HTA/HTB electricity
Insulator support to be tested
PC_F Physics Line - 20
Personnel et confidentiel
Faulty insulator
Electrical maintenance
HTA/HTB electricity
Overheating on insulator connection
PC_F Physics Line - 21
Personnel et confidentiel
Faulty connection on high voltage connection
Mechanical maintenance
PC_F Physics Line - 22
Personnel et confidentiel
Mechanical maintenance
•Because of friction, mechanical parts heat normally
•Aim of thermography: highlight abnormal heating
Replace parts in time
PC_F Physics Line - 23
Personnel et confidentiel
Mechanical maintenance
PC_F Physics Line - 24
Personnel et confidentiel
Testing of mechanical heating
Faulty rotation
Mechanical maintenance
Engine heating
PC_F Physics Line - 25
Personnel et confidentiel
Mechanical maintenance
Unbalanced thresholds
PC_F Physics Line - 26
Personnel et confidentiel
Ventilator
Canalisation and insulation
Blockage in a canalisation
PC_F Physics Line - 27
Personnel et confidentiel
Leaking valve
Canalisation and insulation
Condition of thermal insulation to be inspected
PC_F Physics Line - 28
Personnel et confidentiel
Deterioration of thermal insulation
INDUSTRIALISATION / MANUFACTURING:
Testing of instruments at end of chain, fast general checking, rejection of non-compliant assembly
Endurance tests on « heating table », detection on-the-spot and over time of proper functioning of parts
Endurance tests on « vibrating table », detection of faulty contacts, faulty joints, etc.
Testing of industrial processes
PC_F Physics Line - 29
Personnel et confidentiel
Paper industry
Industry: +120 °C to +900 °C
With high temperature filters (optional)
Research/development
• Scientists researching new methods for solving problems
• Thermocouples:
-
Have to be in contact with the component measured
Effect on the results
• Thermography:
• Non-destructive analysis capacity
• Detects very low differences in temperature, highlights thermal exchange phenomena
• No contact method, highlights the problem
PC_F Physics Line - 30
Personnel et confidentiel
Research/development
Quality control during final phase of development
Protection against short-circuits
Heating of complex processors on printed circuits
PC_F Physics Line - 31
Personnel et confidentiel
Heating at the base of a component
OX7104 Portable oscilloscope
4 isolated channels
Voltage, current, temperature measurement
Recordings, Harmonics
12-bit converter
Colour touch screen with graphic commands
Ethernet communication
MTX 3283 Multimeter
Large display with up to 4x 100,000 counts
V/A automatic selection via leads connection
Recording and graphic processing up to
6,500 measurements
Communication : Bluetooth or RS232 or USB
PC_F Physics Line - 32
Personnel et confidentiel
Research/Development
• Instruments for the general public
Accelerate market launch
Prior to production, comprehensive tests
Ascertain usable power and the manner in which it is dissipated
PC_F Physics Line - 33
Personnel et confidentiel
Research/Development
• Automotive sector
Solutions for thermal protection of engines
Products for monitoring temperature beneath the chassis
Instantly observe critical zones
PC_F Physics Line - 34
Personnel et confidentiel
ResearchDevelopment
• Pharmaceutical industry
Observation of variations in temperature during chemical reaction, study on microplates
PC_F Physics Line - 35
Personnel et confidentiel
Research/development
• Food industry
Development of new cooking/freezing techniques (techniques can be dangerous for public health)
PC_F Physics Line - 36
Personnel et confidentiel
PC_F Physics Line - 37
Personnel et confidentiel
Marie COURRIERE
Marketing / Product Manager
Optimal ergonomy for simplified use
Easy to handle : Reach all the functions with only one hand thanks to its form like a gun
Access to the dropdown menu
Access to the laser aiming
PC_F Physics Line - 38
Personnel et confidentiel
Optimal ergonomy for simplified use
Moveable screen:
Direct the screen according to your positioning with respect to the target
Closed, the LCD screen is protected
PC_F Physics Line - 39
Personnel et confidentiel
Keyboard presentation
PC_F Physics Line - 40
Personnel et confidentiel
RayCAm: the solution in all your measurement conditions
Uninterrupted measurements
Use of the tripod
Too strong luminosity
Use of the sun-shield
More than 4 hours of uninterrupted inspection
2 batteries delivered
Adapted to many industrial conditions
Protection IP 54
RayCAm is delivered with all its accessories in a bag
PC_F Physics Line - 41
Personnel et confidentiel
RayCAm: the solution at your sight
Many pallets available
PC_F Physics Line - 42
Personnel et confidentiel
RayCAm, save time
Inspect in a few seconds …
PC_F Physics Line - 43
Personnel et confidentiel
Automatic recognition of the hottest point …
RayCAm, save time
… and isolate the significant zones: function alarms/isothermal
PC_F Physics Line - 44
Personnel et confidentiel
RayCAm, the +
•A wonderfull memory
1000 radiometric picture recordable
•Near to the target
Measurements from 10 cm
•Precision and simplicity
Target, point and measure with the laser aiming
PC_F Physics Line - 45
Personnel et confidentiel
RayCAm, righter measurements
Possibility of parameterizing directly in RayCAm all the characteristics influencing measurement
Emiss:
Distance:
Temp Amb:
Humidité:
0.95
5 m
25.2 °C
50 %
PC_F Physics Line - 46
Personnel et confidentiel
RayCAm, measurements are posted in real time
All information necessary to your analysis present on your screen
Spot temperature
Operational condition
PC_F Physics Line - 47
Personnel et confidentiel
Emissivity Load state
Time
Scale of the thermogram: a temperature associated with a color
Communication, power supply
Electric cable
USB cable
Video cable
PC_F Physics Line - 48
Personnel et confidentiel
RayCAm range
Performances of the picture
Detector
RayCAm
C.A 1885
RayCAm
C.A 1883
RayCAm
C.A 1881
UFPA microbolometer / Matrix 160 x 120
RayCAm
C.A 1880
Detection frequency Detection à 50 Hz
Dtection 9Hz
Spectral band
Field of sight Dist.
Min. Foc.
NETD
Screen
Picture
0,1 °C
20° x 15°
10 cm
8 to 14 μm
38° x 28°
1 cm
0,12 °C
TFT 2,5’’ color, multi-palette
20° x 15°
10 cm
Live, hold, opening, erasure, 1000 pictures recordable
PC_F Physics Line - 49
Personnel et confidentiel
RayCAm offer
Measurements
Temperature range
Optional range
Precision
Measurements correction
Use temperature
Storage
Relative Humidity
Configuration
RayCAm
C.A 1885
RayCAm
C.A 1883
RayCAm
C.A 1881
-20 °C to 250 °C
RayCAm
C.A 1880
250 °C to 1000 °C
+/- 2°C or +/- 2%
Emissivity, environment temperature, target distance, relative humidity
-20 °C to 50 °C
- 40 °C to 70 °C
20 %HR to 90 %HR – IP 54
Time, unity, language
PC_F Physics Line - 50
Personnel et confidentiel
RayCAm offer
Measurements tools: thermogram analysis
Meas. spot
Detection temp.
RayCAm
C.A 1885
RayCAm
C.A 1883
RayCAm
C.A 1881
RayCAm
C.A 1880
4 moveable 1 moveable
Auto detection of the Max / Min temperature
Analisis area
Precision
Measurements correction
Alert
Ajustable area Omplete thermogram
+/- 2°C or +/- 2%
Emissivity, environment temperature, distance to the target, relative humidity
Sound / Visual None
Isotherm
Posting mono color of a temperature range
None
RayCAm preview Obtaining.jpeg picture
Realization of surveys
Personnel et confidentiel
RayCAm offer
Caractéristiques générales
RayCAm
C.A 1885
RayCAm
C.A 1883
Laser
Alimentation
RayCAm
C.A 1881
635 nm (red) class II, 1 mW
SONY battery 7,2V
Autonomy: 2heures
Programmable deactivation
Interfaces
Weight
Electrical: USB, Video (PAL / NTSC)
Mecanical: tripod
< 700 g
RayCAm
C.A 1880
Delivered state 1 camera + lens, Software
USB, video connexion
2 batteries + 1 loader
Tripod adaptator, Sun-shield
User’s manual, test report
1 camera + lens, Software
USB, video connexion
1 batterie + 1 loader
User’s manual, test report
PC_F Physics Line - 52
Personnel et confidentiel
RayCAm, inspection report
The report is an integral part of a maintenance programme and Vital complement to taking thermograms
Aim:
- Reference database
- Planning of work
- Complementary inspection after repair
=> Requires on-site parameter reading
PC_F Physics Line - 53
Personnel et confidentiel
Ray CA m report analysis software
Easy to use
PC_F Physics Line - 54
Personnel et confidentiel
Personalized reports in all simplicity
Many tools present helping at the creation of your report
Cursor
Thermogram insertion
Picture, logo insertion
Text area insertion
Insertion of a temperature profile
With its table
Result table insertion
Link between a tool and a thermogram
PC_F Physics Line - 55
Personnel et confidentiel
Personalized reports in all simplicity
Multitude of tools for a complete thermogramanalysis
PC_F Physics Line - 56
Personnel et confidentiel
To delete an analysis tool
Personalized reports in all simplicity
Modify the parameters of the thermogram at will!
With each analysis tool, its parameters: associate different emissivities to each point added on your thermogram
Your analysis becomes relevant and in conformity with reality
PC_F Physics Line - 57
Personnel et confidentiel
Reports
Highlights all the elements necessary for the correct interpretation of the phenomenon
Distribution to department(s) concerned
Handling of problem analysed
Implementation of corrective actions
Diffusion within the company
For a better communicatio n within your company, record it under Word
PC_F Physics Line - 58
Personnel et confidentiel
Conclusion…
RayCAm forms integral part of a complete inspection program
Properly implemented and maintained, it has a direct impact on the quality of the products and the production
RayCAm “envisages” the breakdowns…
… CHAUVIN ARNOUX answers to all your requirements with the whole of its range
PC_F Physics Line - 59