CONTENTS • INVERTER K-SERIES • INVERTER Y SINGLE SPLIT (SERIES I & II) INDOORS OUTDOORS • INVERTER Y MULTI SPLIT Technical Training INVERTER K-SERIES Technical Training INVERTER K-SERIES INDOOR W 0.9K 1.4K 2.0K 2.6K 3.2K 3.8K 4.4K 5.8K 8.8K Btu/h 3K 5K 7K 9K 11K 13K 15K 20K 30K R410A (5WMY-KR) 5WMY10/15 KR Technical Training INVERTER K-SERIES OUTDOOR W 0.9K 1.4K 2.0K 2.6K 3.2K 3.8K 4.4K 5.8K 8.8K Btu/h 3K 5K 7K 9K 11K 13K 15K 20K 30K R410A (5LCY-ER) 5LCY10/15 ER Technical Training INVERTER K-SERIES : Features High EER / COP of 5WMY 2.5 kW 3.5 kW EER 3.42 3.37 European EER Rating A A COP 4.06 3.76 European EER Rating A A ECONO Mode Econo Mode is a function that sets a limit for power consumption. This mode is useful for preventing Circuit breakers from being overloaded by the use of multiple air conditioners and other electrical devices. The function is easily activated from the remote controller by pushing the ECONO button. Technical Training INVERTER K-SERIES : Features 5 Speed Fan motor, • inclusive of Quiet Mode Sound Pressure Cooling H/M/L/SL (dBA) Heating 5WMY10KR 40/33/26/22 40/34/28/25 Super Low Speed @ 22 dBA! 5WMY15KR 41/34/27/23 41/35/29/26 Night Set Mode This function prevent excessive cooling or heating for your pleasant sleep. Technical Training INVERTER K-SERIES : Features Indoor Air Quality • Titanium Apatite Photocatalytic Air Purifying Filter Technical Training INVERTER K-SERIES : Features Comfort Airflow Mode “Comfortable Mode” prevents direct airflow to users and reduces discomfort air drafts. When cooling : Flap can be fixed at higher position than the normal cooling operation position. When heating : Flap can be fixed at lower position than the normal heating operation position and warms feet. Normal Operation Comfort Mode 15~45° 0° fixed 0° 5° 15° Normal Operation by one touch ! 45° 5~45° < Cooling > 45° 50° Comfort Mode 50° fixed < Heating > Technical Training INVERTER K-SERIES : Features Standby electricity saving Without this function, about 6W standby electricity is necessary. By cutting power supply to outdoor unit, necessary standby electricity is reduced to 1 W at the least. This new function corresponds to diversified energy saving needs. Operation standby electricity < Without “Standby Electricity Saving” > 1W For indoor unit microcomputer 5W For outdoor unit microcomputer < With “Standby Electricity Saving” > 1W For indoor unit microcomputer 0W (Outdoor unit is suspended) Note: In some conditions, for example when temperature is low, outdoor unit runs microcomputer and preheats compressor and thus uses energy. (About 35 W is necessary for preheating) Technical Training INVERTER Y SINGLE SPLIT Technical Training INVERTER Y SINGLE SPLIT Product Line Up Outdoor Model 5CMY-ER 5CKY-ER 5CKY-CR 5WMY-JR Indoor Model 5WMY-J 10 15 5CKY-E 5LCY-C 5CKY-C 5CMY-E 5CCY-C SERIES I Outdoor Model Indoor Model 5WMY-J 10 15 P P P 5CCY-CR 20 25 P P P P P P P 20 25 60 P P 5CKY-E 5LCY-D 5CCY-C P P P P Indoor Model 5WMY-J 30 40 50 5CKY-E P P P P P P P P P 5CKY-C 5CMY-E Outdoor Model SERIES II 5LCY-E 5CKY-C 5CMY-E 5CCY-C P P Technical Training SERIES I Technical Training SERIES I Indoor: 5WMY-JR W 0.9K 1.4K 2.0K 2.6K 3.2K 3.8K 4.4K 5.8K 8.8K Btu/h 3K 5K 7K 9K 11K 13K 15K 20K 30K R410A (5WMY-JR) 5WMY 10/15/20/25JR Technical Training SERIES I WMY-J Features: High EER/COP performance. • ALL Models rank A/A or Exceeds! (W/W) EER COP 2.5 kW 3.42 3.62 3.5 kW 3.33 3.62 5.0 kW 3.31 3.63 6.0 kW 3.21 3.74 High Quality & Efficiency Daikin DC Inverter compressor High Performance Daikin Inverter Controller 5-speed Step-less Fan operation BioPro IAQ. New Inverter-only Remote Control Technical Training SERIES I Indoor: 5CKY-CR W 0.9K 1.4K 2.0K 2.6K 3.2K 3.8K 4.4K 5.8K 8.8K Btu/h 3K 5K 7K 9K 11K 13K 15K 20K 30K R410A (5CKY-CR) 5CKY 10/15/20CR Technical Training SERIES I Outdoor: 5LCY-DR W 0.9K 1.4K 2.0K 2.6K 3.2K 3.8K 4.4K 5.8K 8.8K Btu/h 3K 5K 7K 9K 11K 13K 15K 20K 30K R410A (5LCY-DR) 5LCY 10/15DR Technical Training SERIES I Outdoor: 5LCY-CR W 0.9K 1.4K 2.0K 2.6K 3.2K 3.8K 4.4K 5.8K 8.8K Btu/h 3K 5K 7K 9K 11K 13K 15K 20K 30K R410A (5LCY-CR) 5LCY 20/25CR Technical Training SERIES I Outlook About the same between 5LCY & 5LCX-series 5LCY10/15D Series 5LCX-C Series * 5LCY20/25 will be using the same casing as 5LCX and mass-production by March 2010 Technical Training SERIES I Piping Length & Elevation Model Max. total piping length (m) Max. height difference (m) Pre-charge Additional for up to charge piping length (m) (g/m) 5LCY10DR 15 10 7.5 20 5LCX10CR 15 5 7.62 20 5LCY15DR 15 10 7.5 20 5LCX15CR 15 5 7.62 20 Technical Training SERIES I Control Box Control box casing using plastic material. Reactor is mounted on outdoor panels. Control box is mounted face down. 5LCY-D 5LCX-C Compact & Lighter Technical Training SERIES I Terminal Block Equipped with 7-segment display to improve serviceability. To retrieve error code & running parameters. Technical Training SERIES I Thermistors 5LCY-D Series Outdoor coil Discharge pipe Outdoor air Heat sink 5LCX-C Series Outdoor coil Discharge pipe Outdoor air - Heat sink thermistor to capture heat sink temperature Technical Training SERIES I Outdoor Fan Both Y-series and X-series are using variable OD fan speed control by ON/OFF cycle motor. Variable speed duty cycle in respond to current system load & ambient condition. 5LCY-D Series 5LCX-C Series 6-speed 2-speed Low ambient -10/15C Technical Training SERIES I Software and Protection 5LCY-D Series 5LCX-C Series OYLM OYLM Auto restart Over current Over heating Software Technical Training SERIES I Control System Compatibility 5LCY-D Series 5LCX-C Series SLM 3 × NETWARE 3* G-WAY × NIM × * Standard handset for CC units, not available yet for wall mounted series. Technical Training SERIES II Technical Training SERIES II Indoor: 5CKY-ER W 4.4K 5.8K 8.8K 11.7K 14.6K 17.6K 20.5K Btu/h 15K 20K 30K 40K 50K 60K 70K R410A (5CKY-ER) 5CKY 28/40/50ER Technical Training SERIES II 5CKY-ER Features Improve Sound Level • • • New CKY-E series is equipped with a newly-developed turbo fan, which has improved the sound pressure level of the unit significantly. 4 selected fan speeds By selecting the Quiet mode, the sound pressure level can be as low as 27dBA. Technical Training SERIES II 5CKY-ER Features Multi comfort- 3 air swing pattern control • 3 selected air swing pattern to suit different requirements Swing mode selection method through wireless handset: -Press SWING button for 4 seconds to enter field setting mode. While in field setting mode, show only SETTING MODE -Press temperature + or – button to select SWING MODE rotation from SWING MODE 1 to SWING MODE 3 -If no mode changes within 4 seconds, unit will operate according to the selected SWING MODE Technical Training SERIES II 5CKY-ER Features Optimum Air Discharge • • Combining 4 ways air discharge and large discharge area on each side Additional of the automatic air swing help to further to evenly distribute conditioned air to every corner of the install area. Technical Training SERIES II 5CKY-ER Features Modern & Elegant Panel Design • • • Unique “Round” side contour Side LED light location Promote Uniform Installation • Same dimension (all capacity) • Rotate able intake grill Allow 90°Rotation Technical Training SERIES II 5CKY-ER Features Lower Height model 2 uniform height base on different capacity Small fan motor Compact body design A B C Technical Training SERIES II 5CKY-ER Features Built-In high head drain pump Built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level Technical Training SERIES II Indoor: 5CMY-ER W 4.4K 5.8K 8.8K 11.7K 14.6K 17.6K 20.5K Btu/h 15K 20K 30K 40K 50K 60K 70K R410A (5CMY-ER) 5CMY 28/40/50ER 5CMY 62CR Technical Training SERIES II 5CMY-ER Features Ceiling and floor installation option -To install below the ceiling Ceiling installation type -To mount at low wall position Easy Serviceability - Control box, motor and blower can be access easily by just pulling down the filter rail. Standing installation type Technical Training SERIES II 5CMY-ER Features Negative ion generator -To increase the amount of negative ion in the air conditioning area, creating more refreshing environment Automatic air swing -The motorized louver enables the air flow to be evenly distributed. -At the same time, negative ion will be released to provide quality air Technical Training SERIES II 5CMY-ER Features Flexible installation -Unit is designed to work with high pressure head drain pump (optional). -To offer flexibility for installation on condensate drain pipe -Drain pump comes with a high head and is incorporate with the float switch as safety protection Technical Training SERIES II 5CMY-ER Features Fresh air option -The unit is designed to draw in fresh air from outdoor. A fresh air knocked out holes is designed within the unit itself to provide better ventilation. Technical Training SERIES II Indoor: 5CCY-CR W 4.4K 5.8K 8.8K 11.7K 14.6K 17.6K 20.5K Btu/h 15K 20K 30K 40K 50K 60K 70K R410A (5CCY-CR) 5CCY 28/38/50/60CR Technical Training SERIES II 5CCY-CR Features Microprocessor controlled -Offer comfortable room conditions according to the needs of the user -Provide protection to components of the air conditioning unit against any fault through its control algorithm Optional duct accessories * Available for 5CCY10-25CR only. Technical Training SERIES II 5CCY-CR Features Auto random restart -Automatically restart according to the last state setting condition when power resumed -Option is provided to cancel this features Double protection drainage system -Primary drain pan: high thermal insulation material and molded in gradient for better condensate water drainage -Secondary drain pan: “built in” to standard unit offers extra protection against possible water leaking problems Technical Training SERIES II Outdoor: 5LCY-ER W 4.4K 5.8K 8.8K 11.7K 14.6K 17.6K 20.5K Btu/h 15K 20K 30K 40K 50K 60K 70K R410A (5LCY-ER) 5LCY 30/40/50/60ER Technical Training SERIES II Piping Length & Elevation Model Max. total piping length (m) Max. height difference (m) Pre-charge Additional for up to charge piping length (m) (g/m) 5LCY30ER 50 30 30 50 5LCY40ER 75 30 30 50 5LCY50ER 75 30 30 50 5LCY60ER 75 30 30 50 Technical Training SERIES II Control Box Control box is vertically mounted facing out of the casing. Main & inverter PCB Technical Training SERIES II Others 5LCY30ER 5LCY40-60ER DC motor DC motor Compressor type Swing Scroll Software Daikin Daikin Auto restart Over current Over heating OD fan Annual Technical Training 2009 SERIES II Control System Compatibility Accessories Compatibility SLM 3 × NETWARE 3* G-WAY × NIM × * Standard handset for CC units, not available yet for wall mounted series. Annual Technical Training 2009 INVERTER Y MULTI SPLIT Annual Technical Training 2009 INVERTER Y MULTI SPLIT Outdoor Unit Indoor Unit 5WMY-JR 5MSY20/25/30BR Multi Split 5CKY-ER 5CKY-CR 5WMY-J 5MSY20BR (1-2 Indoors) 5CKY-C 5WMY-J 5MSY25BR (1-3 Indoors) 5CKY-C 5WMY-J 5CMY-ER P P P P P P P P P P P P P P 5CMY-E 5CCY-C 5MSY30BR (1-4 Indoors) 15 5CMY-E 5CCY-C 5CCY-CR 10 P P 5CKY-E 5CKY-C P 5CMY-E 5CCY-C P P P P 20 P P P P P Technical Training INVERTER Y MULTI SPLIT 5MSY-BR Features Flexibility in Application & Installation • Available for double, triple, and quadruple indoor connections. • Different types of indoor units in the same system. Better Energy Saving • Combination of improved efficiency compressor and intelligent electronic controls. • Achieved class A/A based on European Energy Efficiency Class ratings. Technical Training INVERTER Y MULTI SPLIT Outlook About the same between 5MSY & 5MSX-series 5MSY-B Series 5MSX-A Series Technical Training INVERTER Y MULTI SPLIT Piping Length and Elevation Model Max. total piping length (m) Single indoor max. piping length (m) Max. height difference (m) Pre-charge total piping Prelength charged (m) (kg) Additional charge (g/m) 5MSY20BR 50 25 15 10 2.0 20 5MSX20AR 30 20 5 20 1.65 20 5MSY25BR 60 25 15 20 2.6 20 5MSX25AR 50 20 5 40 2.32 20 5MSY20BR 60 25 15 20 2.6 20 5MSX20AR 60 20 5 40 3.39 20 Technical Training INVERTER Y MULTI SPLIT Control Box OEM Daikin. Control box casing using plastic material. Control box is mounted face down. 5MSY-B Series 5MSX-A Series Compact & Lighter Technical Training INVERTER Y MULTI SPLIT Terminal Block Error Diagnosis No. of LED Location 5MSY-B Series 5MSY-B Series 5MSX-A Series 5 2 Next to terminal block Inside control box 5MSX-A Series Technical Training INVERTER Y MULTI SPLIT Thermistors 5MSY has more feedback where each indoor will be equipped with a gas pipe and liquid pipe thermistors. 5MSY-B Series 5MSX-A Series Outdoor coil Outdoor coil Discharge pipe Discharge pipe Outdoor air Outdoor air Gas pipe x no. of indoor unit Liquid pipe x no. of indoor unit Gas pipe x 1 Liquid pipe x 1 Heat sink Technical Training INVERTER Y MULTI SPLIT Outdoor Fan Similarly, 5MSY-B series and 5MSX-A series are equipped with variable speed motor to cater for different system load & ambient condition. 5MSY-B Series 5MSX-A Series Reluctance DC motor AC tap speed motor (fixed 3 speeds) Low ambient 0C Technical Training INVERTER Y MULTI SPLIT Other Components Compressor Expansion device 5MSY-B Series 5MSX-A Series Swing type Scroll type EXV EXV Swing compressor Different compressor driving method. • Has a higher EER, lower vibration & noise and higher durability. • Technical Training INVERTER Y MULTI SPLIT Software and Protection 5MSY-B Series 5MSX-A Series Software Daikin Longertech Wiring error-check × Priority room setting × Over current Over heating Technical Training INVERTER Y MULTI SPLIT Wiring Error Check Designed to provide convenience for the system to correct wiring errors itself. For unclear local wiring in the case of buried/hidden piping. This function works by letting refrigerant flow from port A and on onward. The indoor coil temperature is detected one by one to check for matching between the piping and wiring. If wiring is corrected or change a new controller, wiring check has to be carried out again. Technical Training INVERTER Y MULTI SPLIT Wiring Error Check For example: If wiring from Port A is correctly connected to Room A, but piping from Port B instead. After self-correction, when unit is turned ON, OD will change the add in memory so that EXV A is link to Port B. Room A Piping connected to Port B Room B Piping connected to Port A Technical Training INVERTER Y MULTI SPLIT Wiring Error Check Press SW3 button to activate wiring check function: • • • The red LEDs will start blinking one after another. The compressor is set to run at fix frequency. Wiring to each ID unit is checked in sequence. It takes 10~15min to complete the check and correction. Result Red LEDs blinking in sequence – self correction complete, unit ready to run. • All LEDs blinking together – fail to self correct, recheck wire and piping. • This function is subjected to following conditions: After unit is first turned ON, need to wait for about 30 seconds for system initialization. • OD ambient > 5C. • To complete 3 minutes standby after unit stops. • Indoor units are not having any other problem. • Technical Training INVERTER Y MULTI SPLIT Priority Room Setting Allow user to set a particular room which takes precedence over the operation mode of other rooms. For example, if Room A is the priority room, when COOL mode is selected in Room A while Room B, C & D are operating in the following mode: Operation mode in Room B, C & D Status of Room B, C & D COOL or DRY or FAN Current operation mode is maintained HEAT The unit enters Standby Mode. Operation resumes when Room A unit stops operating. AUTO If the unit is set to COOL mode, operation continues. If set to HEAT mode, it enters Standby Mode. Operation resumes when Room A unit stops operating. Technical Training INVERTER Y MULTI SPLIT Priority Room Setting This setting must be done when the unit is first installed. Make sure setting is only done for 1 room. Slide SW4 dip switch to the ON side for the corresponding indoor unit to be set as priority room. Technical Training INVERTER Y MULTI SPLIT Control System Compatibility 5MSY-B Series 5MSX-A Series SLM 3 × NETWARE 3* G-WAY × NIM × * Standard handset for CC units, not available yet for wall mounted series. Technical Training HANDSET Wireless handset for 5WMY-K Series Technical Training HANDSET Existing handset G15 Netware 3 G17 G18 Standard handset for CC units only Technical Training HANDSET New wireless handset GS01 GS02 For massproduction in February 2010 Technical Training THE END Technical Training