FDR D-EVO™ the Easy Transition to DR August 2010 FDR D-EVO™ portable Flat Panel Detector (FPD) Features DR Innovation in a standard cassette-size & weight • Same as Cassette Size • Perfect Fit for Easy Retrofits True 14x17˝ Thin - only 0.5˝ thick • Lightest FPD of its size, Only 6 lbs •Exceptional Speed, 5s Preview, 9s cycle • Image Quality • Patented ISS Technology Samples detector output where signal is strongest & shortest resulting in Sharper images with highest DQE 29% of any GOS scintillator • Fujifilm‘s Image Intelligence Processing & Enhancement • Detachable Cord Easy Positioning & Fast and Reliable Imaging FDR D-EVO™ portable Flat Panel Detector (FPD) DR made simple! Dimensions of FDR D-EVO™ If a cassette fits… so will FDR D-EVO™… .59” 15” 18” FDR D-EVO 6 lbs. same dimensions as a standard analog or CR cassette Retrofit Anywhere = Cost Effective Most existing bucky grids are also compatible with FDR D-EVO™. FDR D-EVO™ portable FPD Thinnest! Competition’s Dimensions Canon CXDIs ~19x19” too large… not a direct retrofit 18.8” 18.9” 14x17 image 18.9” CXDI 55G/C 7.5 lbs. 14x17 image 19.3” CXDI 50G/C 10.5 lbs. Requires modification/replacement of Stand & Table bucky FDR D-EVO™ portable FPD CR Cassette Lightest! FDR D-EVO™ lightest, most comparable to standard cassettes what techs are used to FDR D-EVO™ 4.5 lbs. + 1 ½ lbs. Canon CXDI 55G 6 lbs. Carestream DRX-1 + 3 lbs. 7.5 lbs. + 4 lbs. 8.5 lbs. + 6 lbs. Canon CXDI 50G 10.5 lbs. FDR D-EVO™ portable Flat Panel Detector (FPD) FDR D-EVO™ displays 2 or 3 images In the time Canon/Carestream expose 2 Fastest! FDR D-EVO™ portable Flat Panel Detector (FPD) IQ Technology! Capture Method Comparison Traditional GOS FPD allows light to SPREAD& SCATTER Fujifilm’s ISS GOS FPD FDR D-EVO™ portable Flat Panel Detector (FPD) IQ Technology! Fujifilm’s Irradiated Side Sampling (ISS) Fujifilm’s ISS GOS FPD Fujifilm’s FDR D-EVO™ FPD Positions TFTs to CAPTURE X-ray transparent circuitry Light at its strongest Captures signal where its stronger, more focused and shorter distance FDR D-EVO™ portable Flat Panel Detector (FPD) Image Quality! Image Intelligence Image Intelligence on the FDX Console FDR D-EVO™ portable Flat Panel Detector (FPD) Detachable Power Source Reliability Carestream DRX-1 • Battery replace ea. 2-3 hours / 70 – 90 shots (bottlenecks) • Pin required to access battery removal • 2x as LONG for Image transmission (wireless connection) FDR D-EVO™ • READY when you are • Allows FAST preview • Option to Detach cord for positioning FDR D-EVO™ portable Flat Panel Detector (FPD) FDR D-EVO™ Conversion Indirect, ISS technology Dimensions Same as 14x17 cassette Weight 6.1 lbs. Field of View 13.6 x 17” Pixel Size 150 x 150µ Preview/Cycle 5 / 9 sec. Bit Depth 16 bit Communication & Power Detachable cord Product Details FDR D-EVO™ portable Flat Panel Detector (FPD) Comparison Detectors Canon Canon FDR D-EVO™ Carestream DRX-1 CXDI-50G, C CXDI-55G, C GOS, ISS techn. Varian GOS GOS (CsI) GOS (CsI) Advantages Highest DQE 29% (among GoS detectors), Lightest 6 lbs, Easy Retrofit, Fast 5/9 sec. prvw/cycle, Reliable (cord), Image Quality, 3 sec. max expos. (breathing techniques) Wireless positioning, Easy retrofit Warranty, Durability, Price, preview, 5 sec. max exposure Weight (7.5 lbs.), Handle, Easy retrofit, 3 sec. prvw. Detachable cord, Warranty, price, speed, 5 sec. max exposure Disadvantages Lacks “wireless” appeal Slow 20 sec. cycle, 8.2 lbs., 800ms max Exposure limit No Stitching, Battery Δ & charge req., questionable image quality Slow 15 sec. cycle, Heavy (10.6 lbs.), Tethered cord, Difficult retrofit Slow 15 sec. cycle, Limited retrofit Fujifilm FDR D-EVO™ portable Flat Panel Detector (FPD) Retrofit & Workflow Parts of each Configuration X-Ray Room: FDR D-EVO™ (FPD) Power Supply (MP) Operation Room: Control Box (MC) FDX Console FDR D-EVO™ portable Flat Panel Detector (FPD) Configuration Single Retrofit Single Retrofit • Single FPD (shared between upright & table) • Cord from FPD to connector is 5‘ long, two tether host cables available • Single or Two Tether Host Cords connects to single MP Box (power supply) • If two tether host cords used: Remote Power Switch Needed Control unit Desk top computer size It is installed near DX console. No Operation panel Power supply box installed near Cassette FPD FDR D-EVO™ portable Flat Panel Detector (FPD) Configuration Dual Retrofit Dual Retrofit • Dual FPDs dedicated to each upright & table • Single MP Box (power supply) supports both FPDs • Select table, upright or free cassette by menu or manually at FDX Console Control unit Desk top computer size It is installed near DX console. No Operation panel Power supply box Installed near Cassette FPD FDR D-EVO™ portable Flat Panel Detector (FPD) Fujifilm Comparison Suites GE Quantum Q Carestream Agfa DRX-1 Optima 640 GOS, ISS techn. Varian GOS DX-D Varian GOS/CsI GE CsI Advantages 17x17” & 14x17” removable, Speed, Image Quality, Reliable (cord), Flexibility (free work), Stitching 17x17” & 14x17” removable, Wireless, Clean design, Tilting upright, Auto tracking, “Gull wing” table design 17x17” & 14x17” removable, Price, Nice room features (LCD display, overall function) Reputation, Bundling, Market share, Fast 17x17” fixed & 14x17” removable, Price, Reliable basic design, Stitching option, Clean operation Disadvantages No wireless option for FPD Slightly lower DQE, Slower speed Depends on wireless , No stitching, Heavy, questionable image quality HEAVY 12.5 lb FPD, Lower DQE, Quantum rad room, Integrated NX workstation, Tethered cord 16x16” fixed & 16x16” removable, Requires chiller, Heavy FPD Slightly lower DQE, Reputation as lower “tier” vendor FDR D-EVO™ Rad Canon/Varian/ Samsung