FDR D-EVO™
the Easy Transition to DR
August 2010
FDR D-EVO™ portable Flat Panel Detector (FPD)
Features
DR Innovation in a standard cassette-size & weight
• Same as Cassette Size
• Perfect Fit for Easy Retrofits
True 14x17˝
Thin - only 0.5˝ thick
• Lightest FPD of its size, Only 6 lbs
•Exceptional Speed, 5s Preview, 9s cycle
• Image Quality
• Patented ISS Technology
Samples detector output where signal is strongest & shortest
resulting in
Sharper images with highest DQE 29% of any GOS scintillator
• Fujifilm‘s Image Intelligence Processing & Enhancement
• Detachable Cord
Easy Positioning & Fast and Reliable Imaging
FDR D-EVO™ portable Flat Panel Detector (FPD)
DR made simple!
Dimensions of FDR D-EVO™
If a cassette fits… so will FDR D-EVO™…
.59”
15”
18”
FDR D-EVO
6 lbs.
same dimensions as a standard analog or CR cassette
Retrofit Anywhere = Cost Effective
Most existing bucky grids are also compatible with FDR D-EVO™.
FDR D-EVO™ portable FPD
Thinnest!
Competition’s Dimensions
Canon CXDIs ~19x19”
too large… not a direct retrofit
18.8”
18.9”
14x17 image
18.9”
CXDI 55G/C
7.5 lbs.
14x17 image
19.3”
CXDI 50G/C
10.5 lbs.
Requires modification/replacement of Stand & Table bucky
FDR D-EVO™ portable FPD
CR
Cassette
Lightest!
FDR D-EVO™
lightest, most comparable to standard
cassettes
what techs are used to
FDR D-EVO™
4.5 lbs.
+ 1 ½ lbs.
Canon
CXDI 55G
6 lbs.
Carestream
DRX-1
+ 3 lbs.
7.5 lbs.
+ 4 lbs.
8.5 lbs.
+ 6 lbs.
Canon
CXDI 50G
10.5 lbs.
FDR D-EVO™ portable Flat Panel Detector (FPD)
FDR D-EVO™ displays 2 or 3 images
In the time Canon/Carestream expose 2
Fastest!
FDR D-EVO™ portable Flat Panel Detector (FPD)
IQ Technology!
Capture Method Comparison
Traditional GOS FPD
allows light to
SPREAD& SCATTER
Fujifilm’s ISS GOS FPD
FDR D-EVO™ portable Flat Panel Detector (FPD)
IQ Technology!
Fujifilm’s Irradiated Side Sampling (ISS)
Fujifilm’s ISS GOS FPD
Fujifilm’s FDR D-EVO™ FPD
Positions TFTs to CAPTURE
X-ray transparent circuitry
Light at its strongest
Captures signal where its stronger,
more focused and shorter distance
FDR D-EVO™ portable Flat Panel Detector (FPD)
Image Quality!
Image Intelligence
Image Intelligence
on the FDX Console
FDR D-EVO™ portable Flat Panel Detector (FPD) Detachable Power Source
Reliability
Carestream DRX-1
• Battery replace ea. 2-3 hours / 70 – 90 shots (bottlenecks)
• Pin required to access battery removal
• 2x as LONG for Image transmission (wireless connection)
FDR D-EVO™
• READY when you are
• Allows FAST preview
• Option to Detach cord for positioning
FDR D-EVO™ portable Flat Panel Detector (FPD)
FDR D-EVO™
Conversion
Indirect, ISS technology
Dimensions
Same as 14x17 cassette
Weight
6.1 lbs.
Field of View
13.6 x 17”
Pixel Size
150 x 150µ
Preview/Cycle
5 / 9 sec.
Bit Depth
16 bit
Communication & Power
Detachable cord
Product Details
FDR D-EVO™ portable Flat Panel Detector (FPD)
Comparison
Detectors
Canon
Canon
FDR D-EVO™
Carestream
DRX-1
CXDI-50G, C
CXDI-55G, C
GOS, ISS techn.
Varian GOS
GOS (CsI)
GOS (CsI)
Advantages
Highest DQE 29%
(among GoS
detectors),
Lightest 6 lbs, Easy
Retrofit, Fast 5/9
sec. prvw/cycle,
Reliable (cord),
Image Quality, 3
sec. max expos.
(breathing
techniques)
Wireless
positioning,
Easy retrofit
Warranty,
Durability,
Price, preview, 5
sec. max exposure
Weight
(7.5 lbs.),
Handle,
Easy retrofit,
3 sec. prvw.
Detachable cord,
Warranty, price,
speed,
5 sec. max
exposure
Disadvantages
Lacks “wireless”
appeal
Slow 20 sec.
cycle, 8.2 lbs.,
800ms max
Exposure limit
No Stitching,
Battery Δ &
charge req.,
questionable
image quality
Slow 15 sec. cycle,
Heavy (10.6 lbs.),
Tethered cord,
Difficult retrofit
Slow 15 sec. cycle,
Limited retrofit
Fujifilm
FDR D-EVO™ portable Flat Panel Detector (FPD)
Retrofit & Workflow
Parts of each Configuration
X-Ray Room:
FDR D-EVO™
(FPD)
Power Supply
(MP)
Operation Room:
Control Box
(MC)
FDX
Console
FDR D-EVO™ portable Flat Panel Detector (FPD)
Configuration
Single Retrofit
Single Retrofit
• Single FPD (shared between upright & table)
• Cord from FPD to connector is 5‘ long, two tether host cables available
• Single or Two Tether Host Cords connects to single MP Box (power supply)
• If two tether host cords used: Remote Power Switch Needed
Control unit
Desk top computer size
It is installed near DX console.
No Operation panel
Power supply box
installed near Cassette FPD
FDR D-EVO™ portable Flat Panel Detector (FPD)
Configuration
Dual Retrofit
Dual Retrofit
• Dual FPDs dedicated to each upright & table
• Single MP Box (power supply) supports both FPDs
• Select table, upright or free cassette by menu or manually at FDX Console
Control unit
Desk top computer size
It is installed near DX console.
No Operation panel
Power supply box
Installed near Cassette FPD
FDR D-EVO™ portable Flat Panel Detector (FPD)
Fujifilm
Comparison
Suites
GE
Quantum Q
Carestream
Agfa
DRX-1
Optima 640
GOS, ISS techn.
Varian GOS
DX-D
Varian GOS/CsI
GE CsI
Advantages
17x17” &
14x17”
removable,
Speed,
Image Quality,
Reliable
(cord),
Flexibility
(free work),
Stitching
17x17” &
14x17”
removable,
Wireless,
Clean design,
Tilting upright,
Auto tracking,
“Gull wing”
table design
17x17” &
14x17”
removable,
Price,
Nice room
features (LCD
display,
overall
function)
Reputation,
Bundling,
Market share,
Fast
17x17” fixed
& 14x17”
removable,
Price,
Reliable basic
design,
Stitching option,
Clean operation
Disadvantages
No wireless
option for FPD
Slightly lower
DQE,
Slower speed
Depends on
wireless ,
No stitching,
Heavy,
questionable
image quality
HEAVY 12.5 lb
FPD,
Lower DQE,
Quantum rad
room,
Integrated
NX
workstation,
Tethered
cord
16x16” fixed
& 16x16”
removable,
Requires
chiller,
Heavy FPD
Slightly lower
DQE,
Reputation as
lower “tier”
vendor
FDR D-EVO™