View drawing of dimmer panel

advertisement
DOWN
UP
RESET
CENTRAL MONITOR
DIMMER
O Øverland as
ELEKTRONIKK
Monitor Dimmer
O Øverland as
ELEKTRONIKK
Nøysomhedvegen.36 Boks1098 N6403MOLDE
Tlf:+47 71 20 24 00 www.nmea.no epost:post@overland.no
UPC6000 Monitor Dimmer
Central dimming of all Hatteland industrial monitors
This dimmer can adjust up to 13 monitors, but can be expanded to include as many
monitors as desirable. You can also assemble as many control panels as you wish.
The dimmer panel has a weak background light.
The dimmer increases or decreases the light without increments (fine step), from zero
to full brightness.
The maximum brightness is determined by the local dimmer on each monitor.
This makes it possible to adjust the brightness on each monitor individually.
If you push both buttons on the control panel simultaneously, all screens are set at
100 % brightness (full light depends on the local dimmer setting).
EQUIPMENT LIST
Standard
1. Control panel
2. UPC6000 Monitor Dimmer
Option
1. UPC6000 for up to 13 monitors more
2. Extra controll panel
3. 9pin D-sub w/2m cable (to connect to Hatteland monitor)
4. Special cable to connect with Furuno TECDIS w/alarm
5. Older monitors or other monitors, contact O. Øverland AS
24VDC
10
-
+
M13
-
+
M12
-
+
+
M11
-
+
DOWN
S
UP
9
Input
V2
6
4
5
3
2
1
V1
UP
1
UP
2
DOWN
1
DOWN
2
DIN
POWER
UP
UPC-6000
7
POWER
24VDC
+
DIN
8
- + - +
-
DOWN
UP
DOWN
OUTPUT
Monitor Dimmer
USB
RESET
IEC60945
IEC61162-1 C4
IEC61162-2 High Speed Data
O.Øverland as
ELECTRONICS
www.nmea.no
CENTRAL MONITOR
DIMMER
O Øverland as
ELEKTRONIKK
M1
- +
M2
- +
M3
- +
M4
- +
M5
- +
M6
- +
M7
- +
M8
- +
M9
- +
M10
- +
+ pin 5
- pin 3
Special cable
+ pin 3
- pin 5
RS422
RS232
?
?
TelChart
TECDIS
TECDIS w/monitor alarm
A.J.240912
Dimmer Connection
rev.
DWG:
O Øverland as
ELEKTRONIKK
Nøysomhedv.36 Boks1098 N6403MOLDE
TLF.+47 71 20 24 00 FAX.+47 71 25 12 14
Dimmer on system with
comport 1 already in use
TelChart
TECDIS
5 3 2
- + - + - + - +
main
B
sec
POWER
TX
"Write transmitting
instrument here."
INST.
DIN
- +
Tx6
A
INPUT
10mm for
DYMO-tape
DIN
UPC-3002
Serial
Line
Splitter
POWER
INPUT A
INPUT B
OUTPUT
IEC60945
IEC61162-1 C4
IEC61162-2 High Speed Data
O Øverland as
EL EKT RONI KK
www.nmea.no
Tx1
+ -
-
+
M13
-
+
M12
-
+
+
M11
Tx3
+ -
Tx2
+ -
-
+
DOWN
Tx4
+ -
- + - +
S
UP
Tx5
+ -
Input
V2
V1
POWER
5 3 2
DIN
DIN
POWER
DOWN
OUTPUT
Monitor Dimmer
USB
IEC60945
IEC61162-1 C4
IEC61162-2 High Speed Data
O.Øverland as
ELECTRONICS
www.nmea.no
M1
- +
M2
- +
M3
- +
com 1
UP
UPC-6000
M4
- +
-
M5
+
DOWN
M6
- +
M7
- +
-
M8
+
M9
- +
M10
- +
UP
RESET
CENTRAL MONITOR
DIMMER
O Øverland as
ELEKTRONIKK
A.J.061112
Dimmer Connection
rev.
Old type
DWG:
2008
O Øverland as
ELEKTRONIKK
Nøysomhedv.36 Boks1098 N6403MOLDE
TLF.+47 71 20 24 00 FAX.+47 71 25 12 14
Hatteland HD24T21 / HD26T21
2 4 6 8 10
1 3 5 7 9
-
+
M13
-
+
M12
-
+
+
M11
-
+
DOWN
- + - +
S
UP
Input
DIN
V2
V1
POWER
DIN
POWER
UP
UPC-6000
DOWN
OUTPUT
Monitor Dimmer
USB
IEC60945
IEC61162-1 C4
IEC61162-2 High Speed Data
O.Øverland as
ELECTRONICS
www.nmea.no
M1
- +
M2
- +
M3
- +
-
M4
+
M5
- +
M6
- +
DOWN
M7
- +
M8
- +
M9
- +
M10
- +
UP
RESET
CENTRAL MONITOR
DIMMER
O Øverland as
ELEKTRONIKK
A.J.061112
rev.
Dimmer Connection
New Hatteland HD24T21
DWG:
O Øverland as
ELEKTRONIKK
Nøysomhedv.36 Boks1098 N6403MOLDE
TLF.+47 71 20 24 00 FAX.+47 71 25 12 14
UPC-6000
P.O.Box1098 N6403 MOLDE NORWAY
TEL.+47 71 20 24 00 FAX.+47 71 25 12 14
www.overland.no
post@overland.no
MONITOR DIMMER
2x 15-35VDC
ISOLATED
POWER
From controll panel
3 x Monitor
out put
-
+
M13
-
+
M12
DOWN
-
+
+
M11
UP
-
+
DOWN
- + - +
-
S
UP
Input
DIN
V2
V1
POWER
DIN
POWER
UP
UPC-6000
DOWN
OUTPUT
Monitor Dimmer
USB
IEC60945
IEC61162-1 C4
IEC61162-2 High Speed Data
O.Øverland as
ELECTRONICS
www.nmea.no
M1
- +
M2
- +
M3
- +
M4
- +
M5
- +
M6
- +
M7
- +
M8
- +
M9
- +
M10
- +
10 x Monitor output
UPC 6000 Monitor Dimmer
Spesifications:
UPC 6000 is a serial line splitter
with two separate inputs for light up and down
and thirteen monitor outputs.
Made for installation in protected environment.
Dual power input with autoswitching.
The powersupply and both signal inputs are
galvanic isolated from the outputs.
A.J.270912
Specifications:
Powersuppy main:
Powersuppy sec:
12-35Vdc 0,5-0,25A
12-35Vdc 0,5-0,25A
Input A
Input B
Input A / B
Light up
Light down
Light to 100%
Outputs:
13 Hatteland Industri Monitor
All outputs are Short Circuit Protected
Module-box with DIN-rail mounting
Dimensions in mm: L-130 x H-50 x W-80
96
Ø4
85
DOWN
UP
85
RESET
96
CENTRAL MONITOR
DIMMER
O Øverland as
ELEKTRONIKK
70
cut out
O Øverland as
ELEKTRONIKK
55
70
RS-422
M1
+ -
M2
+ -
M3
+ -
M4
+ -
M5
+ -
+
M6
-
M7
+ -
M8
+ -
M9
+ -
M10
+ -
50mm
128mm
-
+
-
+
-
+
M13 M12 M11
+
- +
-
DOWN UP
Input
DIN
- +- +
S V2
V1
POWER
POWER
UPC-6000
Monitor Dimmer
O.Øverland as
ELECTRONICS
www.nmea.no
DIN
UP
DOWN
128mm
OUTPUT
USB
IEC60945
IEC61162-1 C4
IEC61162-2 High Speed Data
DIN-RAIL
M1 M2 M3 M4 M5 M6 M7 M8 M9 M10
- + - + - + - + - + - + - + - + - + - +
O Øverland as
ELEKTRONIKK
Nøysomhedvegen.36 Boks1098 N6403MOLDE
Tlf:+47 71 20 24 00 www.nmea.no epost:post@overland.no
Download