Training modules 1. What’s new in SmartTool? 2. What can SmartTool do for my borehole? 3. Meet the hardware 4. MeasureIT software that sets-up, runs, calculates & checks. 5. Practical exercises with the SmartTool. 6. DisplayIT software, showing off the results. 7. The Single-shot StoreIT menus. 8. The Multi-shot StoreIT menus. 1 What’s new -- SensIT probe -- sealed and unopenable no plugs or cables 1 What’s new -- StoreIT data pad -- sealed in an Aquapac, -- hung on a lanyard. 1 What’s new -- SensIT & StoreIT -ten years power - built in, no batteries or chargers. no plugs or cables 1 What’s new -- SensIT, StoreIT & your PC -transfer data by automatic fast radio link. 1 What’s new -- Quality assurance system -warns of magnetism or movement 1 What’s new -- SensIT in its pressure barrel Shock resistant to 6000G Shockproof to 6000g Watertight to 4000 metres 2 What can SmartTool do for me? -- Four different tasks Single-shot survey ----- read data on StoreIT ----- combine data on PC to make … Multi-shot survey 3D hole path using magnetic azimuth measurement Orientated survey ----- less than 30m, close to vertical 3D hole path maintaining azimuth with orientation rods Tool or Core orientation, using Gravity roll angle ---- for inclined holes Magnetic toolface angle --- for vertical holes 2 What can SmartTool do for me? -- Eight measurements at each DEPTH (shot) recorded by SensIT 1 Dip (Inclination) of hole 2 Direction (azimuth) of hole for Positional Survey 3 Gravity Roll angle of SensIT 4 Toolface angle of SensIT for Orientation 5 Magnetic field strength 6 Magnetic dip angle for Quality Assurance 7 Temperature of SensIT 8 Depth, time and date for the record 2 What can SmartTool do for me? -- Survey 2 What can SmartTool do for me? -- Orientation Setting the zero Gravity Roll Angle 2 What can SmartTool do for me? -- Orientation Setting the zero MagneticToolface Angle 2 What can SmartTool do for me? -- Quality assurance. The Earth’s Gravitational Field 2 What can SmartTool do for me? -- Quality assurance. The Earth’s Gravitational Field If Grav. Field is not 1.00 G, then SensIT is moving; Dip and Azimuth may both be unreliable 2 What can SmartTool do for me? -- Quality assurance. The Earth’s magnetic field Variation - angular difference between True North and Magnetic North Magnetic Field Strength - the force of the earth's magnetic field Magnetic Dip Angle - angle the field force lines make with the horizontal At each place on the earth's surface, these values are known. 2 What can SmartTool do for me? -- Quality assurance. Set the threshold for the local magnetic environment 2 What can SmartTool do for me? -- Quality assurance. Identify the unreliable azimuths Training modules 1. What’s new in SmartTool? 2. What can SmartTool do for my borehole? 3. Meet the hardware 4. MeasureIT software that sets-up, runs, calculates & checks. 5. Practical exercises with the SmartTool. 6. DisplayIT software, showing off the results. 7. The Single-shot StoreIT menus. 8. The Multi-shot StoreIT menus. Training modules 1. What’s new in SmartTool? 2. What can SmartTool do for my borehole? 3. Meet the hardware 4. MeasureIT software that sets-up, runs, calculates & checks. 5. Practical exercises with the SmartTool. 6. DisplayIT software, showing off the results. 7. The Single-shot StoreIT menus. 8. The Multi-shot StoreIT menus. 7 The StoreIT Single-shot menus DATA, Shows Survey SETTINGS #, Hole Ref. & Depth Azimuth Inclination Mag Field Mag Dip G.R/angle M.T/face Time Date Temperature >>Press SETTINGS to exit Timer } +/Depth }3 +/ Hole ref. } +/- OK Enter Archive OK Set Mag Field/Dip OK Zero G.R/angle OK Zero M.T/face OK Set time +/- OK Set date +/- OK Multi-shot mode? OK >>Press NEW to start timer Here the DATA button displays each reading from a Single-shot survey. 8 The StoreIT Multi-shot menus First survey press New Next Survey press New SETTINGS 1 Change SETTINGS 2 Hole ref. } Next Depth Start depth } Depth interval Depth interval } 5 End survey Direction } >>Press DATA Time interval } to continue survey Set time Set date Single-shot mode? >>Press DATA for first survey Change SETTINGS 3 Hole ref. Start depth Depth interval Direction End session -download >>Press DATA for next survey • Here the DATA button is only a switch from the SETTINGS menus back to the survey operation.Then, to start a survey, press NEW