New TDA100D

advertisement
TDA100D
Contents
1
2
3
4
5
6
Target Customer
Selling Points
Improvement from current KX-TDA100
System Configuration
Compatibility between TDA100D and TDA/TDE
New PCMC
1
1. Target Customer
2
1. Target Customer
Solutions >>
Small - Mid Size Office
Target : 16 - 120 SLTs
MPR
DLC4
MCSLC 24/16 Card
MCSLC 24/16 Card
MCSLC 24/16 Card
MCSLC 24/16 Card
MCSLC 24/16 Card
New 24/16 SLC card
for 120 SLTs
Built-in
4 Digital PT
Ports
Digital PT for manager or operator
Single Line Telephone for employees
Even if SLTs are mainly used, a few Digital PTs are required for manager or operator.
New TDA100D has built-in support for 4 DLC ports for these Digital PTs.
3
1. Target Customer
Solutions >>
Warehouse, Car dealer, Factory...
With System Wireless
Retail Stores
Warehouses
MPR
DLC4
Large Residences
Built-in
4 Digital PT
Ports
Schools
Automotive Dealerships
Factories
Wireless system give you anytime, anywhere access.
New TDA100D supports 4 DLC ports for these wireless systems without the
need for options.
4
1. Target Customer
Solutions >>
Small Hotel
Target : 30 - 50 Rooms
MPR
MCSLC 24/16 Card
MCSLC 24/16 Card
DLC4
MCSLC 24/16 Card
Built-in
4 Digital PT
Ports
System Wireless for staff
232C
Serial
New 24/16 SLC card
for 50 SLTs
EXT.(room)101 call detail
Digital PT for front desk
KX-T7710 for each room
CA Call Accounting for simple billing
New TDA100D has built-in support for 4 DLC ports for DPTs and system wireless
without the need for options.
If you use CA Call Accounting (FOC), it is easy to make a call billing per room.
5
2. Selling Points
6
2. Selling Points
Solutions >>
Simple Installation
【Current TDA100】
【New TDA100D】
PSU
Built-in
PSU
DLC
DLC4
For Wireless System
Provide reasonable wireless
system with Built-in DLC and
Entry DECT terminal.
NO
Need
CSIF Card
DLC Card
For DPITS Programming
Built-in DLC4 can be used for
DPITS programming without
additional DLC.
For Future expansion
No need for PSU type
selection. Built-in New PSU
enables future expansion.
Before
Programming
DPITS
NO
Need
Over-Capacity PSU for
the Future Expansion.
New
New
Built-in!
DLC Card
PSU-S
SLT
Entry DECT
7
2. Selling Points
Solutions >>
Flexible Expansion
New Analog CO Cards & New 24/16 port SLC Cards save slots and
provide expanded capacity
New 24/16 port SLC Card
Built-in both Caller ID Function and
Message Waiting Lamp Control
New Analog CO Card
Built-in Caller ID Function
【Current】
【New】
【Current】
【New】
Need 2 types of card
(CSLC & MSLC)
Only need One card
(MCSLC24/16)
Need one LCOT16
+ 2 CID card
Only need two cards
(CLCOT8 + CLCOT8E)
8-port expansion
8-port base analogue daughter card
KX-TDA1186
CO card
KX-TDA1180
8
2. Selling Points
Solutions >>
Wide Cover from Upper TES824 to TDA200 Range
【New】
【Current 】
16 - 120SLT
8 - 64SLT
(24SLT× 5 + Built-in PSU)
(16SLT x 4 + OPB + PSU-S)
Max SLT Capacity
16
from small to
mid-sized office
Plus more 8-DPT or Wireless
24
64
96
120
128
TDA100D Range
PSU/DLC4
Built-in
Targeting between 24 to 120 SLT
PSU-M
TDA200
TDA
100
TES824 Range
PSU-S
TDA100 Range
TDA200 Range
TDA
100
PSU-M MEC
Card
9
3. Improvements from Current KX-TDA100
10
3. Improvements from Current KX-TDA100
Solutions >>
Feature Differnce from Current KX-TDA100 V5*
Built-in
USB
Serial I/F
1 2 3 4 5 6
MPR
Free slot
Free slot
Free slot
Free slot
Free slot
Free slot
Serial I/F
USB
* PBX software feature is the same as KX-TDA100/200 MPR version 5.
* Message waiting specification is similar to current MSLC16.
* Caller ID specification is similar to current CSLC16.
* Provide new PC Maintenance Console dedicated for TDA100D
(separated from current UPCMC)
* All kind of card will be able to install to Slot 7
< Current TDA100 >
PSU-S/M (Option)
3. New Analog CO card
with built-in Caller ID
8 ports by default and additional 8 ports expandability in
same slot by option for easy expandability.
4. New MPR card
with built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F
5. New Shelf with built-in Power Supply Unit
6. SMDR Call storage – 2500 calls
DLC4
with built-in Caller ID* and Message Waiting Lamp Control*
1 2 3 4 5 67
Free slot
Free slot
Free slot
Free slot
Free slot
Free slot
Free slot
1. System Capacity - 120 SLT port
without MEC and Power Supply Unit replacement
2. New 24/16 port SLC card
< New TDA100D >
New PSU (Built-in)
More
Flexibility
MPR
More SLT
Capacity
11
3. Improvements from Current KX-TDA100
Solutions >>
System Capacity
Simpler installation to expand system capacity than the current TDA100.
No additional MEC or PSU is required for Max. configuration (including 128 SLT or 152 DPT/IP-PT).
- Memory Expansion Card is NOT required for more than 64 extensions.
- No need to replace PSU for more than 64 extensions.
Model
MEC
Extension
Trunk
PSU
System Total
MPR DPT(DXDP)
Free IP-PT
Slot SLT
DPT(DXDP)
Total
System Total
Free LCOT
Slot BRI
PRI
IP-GW
TDA100 (reference)
w/o MEC
(Max. No. of User is 64)
PSU-S
PSU-M
64

0

64

64

64

64

120

96

96(48BRI)

120(4PRI)

64

w/MEC
PSU-S
96
0
96
64
64
96
120
96
96(48BRI)
120(4PRI)
64
PSU-M
160
0
96
96
128
160
120
96
96(48BRI)
120(4PRI)
64
TDA100D
Regardless
MEC
New PSU (Built-in)
176 (*)
4 (8)
112
128
96(96)
168
126 (**)
112
112(56BRI)
120(4PRI)
64
(*) TDA100D: In case of PT configuration : Max. 176 extensions with 104 DPT(DXDP) + 48 IP-PT + 24SLT
(**) Max. 126 trunks with one PRI30 + 96 LCOT. When installing T1, E1, PRI30, or PRI23 cards, make sure that the
number of these cards X 2 + the number of other cards (including IP-GW4E cards) does not exceed 8.
12
3. Improvements from Current KX-TDA100
Solutions >>
New SLC24/16 Card (MCSLC24/MCSLC16) with CID and MW lamp
Provide New 24/16 ports SLT interface card with built-in Caller ID and Message Waiting Lamp control.
With this card, users can expand the number of SLT extensions up to 128. (Cannot use DLC4 on MPR cards.)
Configuration Example
Slot
TDA100 w/PSU-M
TDA100D w/new PSU
TDA100D w/new PSU
MPR
-
4DPT I/F
-
1
DHLC8
New MCSLC24/MCSLC16
New MCSLC24
2
SLC16
New MCSLC24/MCSLC16
New MCSLC24
3
SLC16
New MCSLC24/MCSLC16
New MCSLC24
4
SLC16
New MCSLC24/MCSLC16
New MCSLC24
5
SLC16
New MCSLC24/MCSLC16
New MCSLC16
6
(Trunk)
(Trunk)
New MCSLC16
7
-
(OPB3)
(Trunk)
SLT Total
72
120
128
Specifications
- 24/16 SLT ports per card
- Max. 5 MCSLC24/Max.7 MCLSC16 cards per PBX
- 2 Power Failure Transfer (PFT) ports
- Built-in Caller ID (FSK) & Message Waiting Lamp Control
* Caller ID specification is similar to current CSLC16.
* Message waiting Lamp specification is similar to current MSLC16.
* No self diagnostic function by PCMC
13
3. Improvements from Current KX-TDA100
Solutions >>
New 8-port Analog CO Card with 8-port expansion
Provide New 8-port Analog CO line interface card with 8-port expansion board.
New card will support CID functions as a standard. Accordingly, this card will provide flexible system
expansion capability and low-cost installation for users that require CID.
Built-in
Caller ID circuit
Built-in
Caller ID Circuit
2 PFT ports
Mount to Base board
8-port base LCOT card
Specifications
8–port expansion daughter card
- 8 analog trunk ports per card
- Expand up to 16 ports with 8 ports daughter card
- 2 power failure transfer (PFT) ports for 8 / 16 ports
- Built-in Caller ID
- Pay tone detection is not available
- User-supplied Amphenol connector I/F
14
3. Improvements from Current KX-TDA100
Solutions >>
New MPR Card for TDA100D
Built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F for easy and cost effective installation.
Users who mainly use SLT do not need to purchase DHLC cards at the initial installation. In addition,
- Expand SRAM capacity for supporting SMDR data registration up to 2500 calls
- I/F for two Music On Hold input ports and two External Pager output connectors will be changed to a RJ45.
- Serial Interface (RS-232C) port will be mounted on MPR card
Note: 1. System will not work correctly when a new MPR card is installed to an existing TDA/TDE shelf.
But no safety issues will occur.
2. Exchange cable, from MOH/Pager mini jack to RJ45, will not be provided.
TDA100
MPR
New
TDA100D
MPR
RJ11
For DLC
4 Ports
SCALE-UP
RJ45
For MOH x2
& Pager x2
RS-232C
For SMDR
FRONT VIEW
SIDE VIEW
FRONT VIEW
15
3. Improvements from Current KX-TDA100
Solutions >>
New Shelf and Power Supply Unit for TDA100D
A new shelf with built-in Power Supply Unit (PSU) is provided.
New power supply supports up to 128 load figure including max.104 for DPT/CS (see below).
Therefore, users do not need to replace PSU when expanding the system.
In this respect, TDA100D will cover TDA200 user range.
Note: 1. Power supply and Shelf will be a new design, so there will be some incompatibility with
the existing TDA/TDE series.
2. Current PSU-S/M (TDA0108/TDA0104) will not be used for TDA100D.
3. System will not work correctly when existing TDA/TDE MPR cards are installed in to a
new TDA100D shelf. In this case, no safety issues will occur.
Calculate the load figure from the type of equipment to be connected.
Type
System Total
Maximum Load Figure
(DPT, CS and SLC card)
DPT and CS
New PSU-S
(Built-in)
Add 7th
Slot
Type
PT
SLT card
New Shelf and Power Supply
CS
128
104
Load Figure
DPT (DT300, T7600)
1
IP-PT
0
New MCSLC24
24
New MCSLC16
16
2-4ch CS
4
8ch CS
8
16
4. System Configuration
17
4. System Configuration
Solutions >>
Optional Card / Unit
Trunk
<Option>
Total
LCOT4
LCOT8
LCOT16
CLCOT8
CLCOT8E
DID8
E&M8
BRI4
BRI8
T1
E1
PRI30
PRI23
IP-GW4
IP-GW4E
IP-GW16
CS
Max. Number of card/unit
TDA100 TDA200 TDA100D
6 (*1)
8 (*1)
7 (*1)
6
8
7
-
-
7
6
8
7
4
4
4
4
4
4
CS(2-4ch)
32
32
26
CS(8ch)
16
16
13
<Option>
Ext
Total
4DPT I/F on MPR
DLC8
DLC16
IP-EXT16
DHLC8
SLC8
SLC16
CSLC16
MSLC16
New MCSLC24
New MCSLC16
CSIF4
CSIF8
CTI-LINK
OPB3
MSG4
ESVM2
ESVM4
DPH4
DPH2
EIO4
ECHO16
Max. Number of card/unit
TDA100 TDA200 TDA100D
6
8
7
1
6
8
7
6
8
-
4
4
5
7
4
1
4
1
4
1
4
4
4
4
4
8
4
2
4
8
4
2
4
8
4
2
(*1) One T1, E1, PRI30, PRI23, or IP-GW4 card counts as 2 cards.
18
4. System Configuration
Solutions >>
SLT Max. Capacity Comparison
TDA100
PSU-S
PSU-M
Extension
System Total
MPR
DPT(DXDP)
Slot
SLT
64
0
64
96
0
96
TDA200
PSU-M
PSU-L
128
0
128
TDA100D
New PSU
128
0
128
128
4 (8 w/DXDP)
120
0
128
Analog CO
128
112
96
TDA100
w/ PSU-M & MEC
TDA200 w/ PSU-M
TDA100
w/ PSU-S
48
Expanded SLT capacity
32
16
0
64
96
120 128
SLT
<CO and SLT capacity chart >
19
5. Compatibility between TDA100D and TDA/TDE
20
5. Compatibility between TDA100D and TDA/TDE
Solutions >>
New Cards for existing TDA/TDE system
Model
Description
TDE100/200 TDA100/200
MPR V3
MPR V5
MPR Software
-
MPR Software of TDA100D
No
No
MPR Card
-
MPR card of TDA100D (w/ DLC4)
No
No
Trunk Cards
Extension Cards
Power Supply
Unit
KX-TDA1180
8-Port Analogue Trunk Card with CID (CLCOT8)
No
(in future)
No
KX-TDA1186
8-Port Analogue Trunk with Caller ID daughter Card
(CLCOT8E)
No
(in future)
No
KX-TDA1178
24-Port Single Line Telephone Card
w/ Caller ID & MW Lamp control (MCSLC24)
No
(in future)
No
KX-TDA1176
16-Port Single Line Telephone Card
w/ Caller ID & MW Lamp control (MCSLC16)
No
(in future)
No
New S-Type Power Supply Unit (new PSU-S)
No
No
-
21
5. Compatibility between TDA100D and TDA/TDE
Solutions >>
Existing Card for TDA100D (1/3)
MPR Software
Optional SD Memory
Cards
MPR Card
MPR Option Card
Trunk Cards
Model
KX-TDA0820
KX-TDA0920
Description
MPR Software of TDA100/200
SD Memory Card for Software Upgrade
SD Memory Card for Software Upgrade to Enhanced Version
KX-TDA0105
KX-TDA0196
KX-TDA0180
KX-TDA0181
KX-TDA0182
KX-TDA0183
KX-TDA0184
KX-TDA0187
KX-TDA0188
KX-TDA0189
KX-TDA0193
KX-TDA0284
KX-TDA0288
KX-TDA0290CE
KX-TDA0290
KX-TDA0480
KX-TDA0484
KX-TDA0490
MPR card of TDA100/200 or TDE100/200
Memory Expansion Card (MEC)
Remote Card (RMT)
8-Port Analogue Trunk Card (LCOT8)
16-Port Analogue Trunk Card (LCOT16)
8-Port DID Card (DID8)
4-Port Analogue Trunk Card (LCOT4)
8-Port E & M Trunk Card (E&M8)
T-1 Trunk Card (T1)
E-1 Trunk Card (E1)
8-Port Caller ID/Pay Tone Card (CID/PAY8)
8-Port Caller ID Card (CID8)
4-Port BRI Card (BRI4)
8-Port BRI Card (BRI8)
PRI Card (PRI30)
PRI Card (PRI23)
4-Channel VoIP Gateway Card (IP-GW4)
4-Channel VoIP Gateway Card (IP-GW4E)
16-Channel VoIP Gateway Card (IP-GW16)
TDA100D
No
No
Yes(*1)
No(*2)
No (*3)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(*1): KX-TDA0920 will be updated before TDA100D released,
(*2): Existing TDA/TDE MPR card will be able to install TDA100D KSU physically, but function will not work properly.
(*3): DMPR support 2500 SMDR data registration, so that No MEC card support is needed
22
5. Compatibility between TDA100D and TDA/TDE
Solutions >>
Existing Card for TDA100D (2/3)
Extension Cards
Other Cards
Model
KX-TDA0143
KX-TDA0144
Description
4 Cell Station Interface Card (CSIF4)
8 Cell Station Interface Card (CSIF8)
TDA100D
Yes
Yes
KX-TDA0170
KX-TDA0171
KX-TDA0172
KX-TDA0173
KX-TDA0174
8-Port Digital Hybrid Extension Card (DHLC8)
8-Port Digital Extension Card (DLC8)
16-Port Digital Extension Card (DLC16)
8-Port Single Line Telephone Extension Card (SLC8)
16-Port Single Line Telephone Extension Card (SLC16)
KX-TDA0175
KX-TDA0177
16-Port Single Line Telephone Card with MW Lamp (MCSLC16)
16-Port Single Line Telephone Card with Caller ID (CSLC16)
No
No
KX-TDA0470
KX-TDA0161
KX-TDA0162
KX-TDA0164
KX-TDA0166
KX-TDA0168
KX-TDA0190
KX-TDA0191
KX-TDA0192
KX-TDA0194
16-Channel VoIP Extension Card (IP-EXT16)
4-Port Door phone Card (DPH4)
2-Port Door phone Card (German Type) (DPH2)
4-Port External Input/Output Card (EIO4)
16-Channel Echo Canceller Card (ECHO16)
Extension Caller ID Card (EXT-CID)
Optional 3-Slot Base Card (OPB3)
4-Channel Message Card (MSG4)
2-Channel Simplified Voice Message Card (ESVM2)
4-Channel Simplified Voice Message Card (ESVM4)
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
KX- TDA0410
CTI Link Card (CTI-LINK)
Yes
No
Yes(*1)
Yes(*1)
No
No
(*1): KX-TDA0171,0172 LPR Software will be updated before TDA100D released,
so that when users use these existing cards for TDA100D, users must update to new software
23
5. Compatibility between TDA100D and TDA/TDE
Solutions >>
Existing Card for TDA100D (3/3)
Power Supply
Units (PSUs)
Cell Stations
(CSs)
2.4GHz
DECT
DECT
6.0
Proprietary Equipment
Model
KX-TDA0103
KX-TDA0104
KX-TDA0108
KX-TDA0141
KX-TDA0142
KX-TDA0151
KX-TDA0152
KX-TDA0141CE
KX-TDA0142CE
KX-TDA0155CE
KX-TDA0156CE
KX-TDA0158CE
KX-T0155
KX-TDA0156
KX-T0158
KX-A228
KX-A229
KX- A258
KX-T30865
KX-T7765
Description
L-Type Power Supply Unit (PSU-L)
M-Type Power Supply Unit (PSU-M)
S-Type Power Supply Unit (PSU-S)
2-Channel CS Using a DHLC/DLC Card for 2.4 GHz PS
3-Channel CS Using a CSIF Card for 2.4GHz PS
2-Channel CS Using a DHLC/DLC Card for 2.4 GHz PS
3-Channel CS Using a CSIF Card for 2.4GHz PS
2-Channel CS Using a DHLC/DLC Card for DECT PS
4-Channel CS Using a CSIF Card for DECT PS
2-Channel CS Using a DHLC/DLC Card for DECT PS
4-Channel CS Using a CSIF Card for DECT PS
8-Channel CS Using a DHLC/DLC Card for DECT PS
2-Channel CS Using a DHLC/DLC Card for DECT 6.0 PS
4-Channel CS Using a CSIF Card for DECT 6.0 PS
8-Channel CS Using a DHLC/DLC Card for DECT 6.0 PS
S/M-type Back-up Battery Cable
L-type Back-up Battery Cable
Blank Slot Cover
Door Phone
Door Phone
TDA100D
No
No
No
No
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
24
5. Compatibility between TDA100D and TDA/TDE
Solutions >>
Terminal Compatibility for TDA100D (1/2)
Model
DPT
Description
TDA100D
DT300
DT346
6Line-LCD, with Backlight, 12CO, USB, Bluetooth optional
Yes
Series
DT343
3LIne-LCD, with Backlight, 12CO, USB, Bluetooth optional
Yes
DT333
3Line-LCD, No Backlight
Yes
DT321
1Line-LCD, 8CO
Yes
DT390
DSS console
Yes
T7600
T7636
6Line-LCD, with Backlight, 12CO, USB Optional
Yes
Series
T7633
3LIne-LCD, with Backlight, 12CO, USB Optional
Yes
T7630
3Line-LCD, No Backlight
Yes
T7668
1Line-LCD
Yes
T7667
1Line-LCD, No Backlight, 12CO
Yes
T7665
1Line-LCD, No Backlight
Yes
T7625
No-LCD
Yes
T7640
DSS console
Yes
T7500 series
No
T7400 series
No
T7200 series
No
25
5. Compatibility between TDA100D and TDA/TDE
Solutions >>
Terminal Compatibility for TDA100D (2/2)
Model
APT
Description
TDA100D
T7700 series
No
T7300 series
No
T7100 series
No
T7000 series
No
PT
T7710
No-LCD, Message Lamp
Yes
PS
DECT
TCA155,TCA256,TCA355, CA175、TCA275, etc.
Yes
DECT6.0
TD7685,TD7695, TD7996
Yes
2.4G
TD7684,TD7694, etc.
Yes
TVM200
TDA100D supports two VM system (12port/24ch)
Yes
TVM50
TDA100D supports two VM system (3port/6ch)
Yes
Voice Mail
Note: There will be some differences between TDA100D and existing TDA/TDE series as follow.
1) SMDR and HOTEL information registration capacity will be increased up to 2500.
2) Broadcasting (Announcement to 31 members) will be activated without MEC.
26
6. New PCMC
27
6. New PCMC
Solutions >>
Dedicated PCMC for TDA100D
"Multi-Site PBX Manager“ not supported
Displayed only as the
"TDA100D" icon
in the "New" window.
28
End of Document
29
Download