TDA100D Contents 1 2 3 4 5 6 Target Customer Selling Points Improvement from current KX-TDA100 System Configuration Compatibility between TDA100D and TDA/TDE New PCMC 1 1. Target Customer 2 1. Target Customer Solutions >> Small - Mid Size Office Target : 16 - 120 SLTs MPR DLC4 MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card MCSLC 24/16 Card New 24/16 SLC card for 120 SLTs Built-in 4 Digital PT Ports Digital PT for manager or operator Single Line Telephone for employees Even if SLTs are mainly used, a few Digital PTs are required for manager or operator. New TDA100D has built-in support for 4 DLC ports for these Digital PTs. 3 1. Target Customer Solutions >> Warehouse, Car dealer, Factory... With System Wireless Retail Stores Warehouses MPR DLC4 Large Residences Built-in 4 Digital PT Ports Schools Automotive Dealerships Factories Wireless system give you anytime, anywhere access. New TDA100D supports 4 DLC ports for these wireless systems without the need for options. 4 1. Target Customer Solutions >> Small Hotel Target : 30 - 50 Rooms MPR MCSLC 24/16 Card MCSLC 24/16 Card DLC4 MCSLC 24/16 Card Built-in 4 Digital PT Ports System Wireless for staff 232C Serial New 24/16 SLC card for 50 SLTs EXT.(room)101 call detail Digital PT for front desk KX-T7710 for each room CA Call Accounting for simple billing New TDA100D has built-in support for 4 DLC ports for DPTs and system wireless without the need for options. If you use CA Call Accounting (FOC), it is easy to make a call billing per room. 5 2. Selling Points 6 2. Selling Points Solutions >> Simple Installation 【Current TDA100】 【New TDA100D】 PSU Built-in PSU DLC DLC4 For Wireless System Provide reasonable wireless system with Built-in DLC and Entry DECT terminal. NO Need CSIF Card DLC Card For DPITS Programming Built-in DLC4 can be used for DPITS programming without additional DLC. For Future expansion No need for PSU type selection. Built-in New PSU enables future expansion. Before Programming DPITS NO Need Over-Capacity PSU for the Future Expansion. New New Built-in! DLC Card PSU-S SLT Entry DECT 7 2. Selling Points Solutions >> Flexible Expansion New Analog CO Cards & New 24/16 port SLC Cards save slots and provide expanded capacity New 24/16 port SLC Card Built-in both Caller ID Function and Message Waiting Lamp Control New Analog CO Card Built-in Caller ID Function 【Current】 【New】 【Current】 【New】 Need 2 types of card (CSLC & MSLC) Only need One card (MCSLC24/16) Need one LCOT16 + 2 CID card Only need two cards (CLCOT8 + CLCOT8E) 8-port expansion 8-port base analogue daughter card KX-TDA1186 CO card KX-TDA1180 8 2. Selling Points Solutions >> Wide Cover from Upper TES824 to TDA200 Range 【New】 【Current 】 16 - 120SLT 8 - 64SLT (24SLT× 5 + Built-in PSU) (16SLT x 4 + OPB + PSU-S) Max SLT Capacity 16 from small to mid-sized office Plus more 8-DPT or Wireless 24 64 96 120 128 TDA100D Range PSU/DLC4 Built-in Targeting between 24 to 120 SLT PSU-M TDA200 TDA 100 TES824 Range PSU-S TDA100 Range TDA200 Range TDA 100 PSU-M MEC Card 9 3. Improvements from Current KX-TDA100 10 3. Improvements from Current KX-TDA100 Solutions >> Feature Differnce from Current KX-TDA100 V5* Built-in USB Serial I/F 1 2 3 4 5 6 MPR Free slot Free slot Free slot Free slot Free slot Free slot Serial I/F USB * PBX software feature is the same as KX-TDA100/200 MPR version 5. * Message waiting specification is similar to current MSLC16. * Caller ID specification is similar to current CSLC16. * Provide new PC Maintenance Console dedicated for TDA100D (separated from current UPCMC) * All kind of card will be able to install to Slot 7 < Current TDA100 > PSU-S/M (Option) 3. New Analog CO card with built-in Caller ID 8 ports by default and additional 8 ports expandability in same slot by option for easy expandability. 4. New MPR card with built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F 5. New Shelf with built-in Power Supply Unit 6. SMDR Call storage – 2500 calls DLC4 with built-in Caller ID* and Message Waiting Lamp Control* 1 2 3 4 5 67 Free slot Free slot Free slot Free slot Free slot Free slot Free slot 1. System Capacity - 120 SLT port without MEC and Power Supply Unit replacement 2. New 24/16 port SLC card < New TDA100D > New PSU (Built-in) More Flexibility MPR More SLT Capacity 11 3. Improvements from Current KX-TDA100 Solutions >> System Capacity Simpler installation to expand system capacity than the current TDA100. No additional MEC or PSU is required for Max. configuration (including 128 SLT or 152 DPT/IP-PT). - Memory Expansion Card is NOT required for more than 64 extensions. - No need to replace PSU for more than 64 extensions. Model MEC Extension Trunk PSU System Total MPR DPT(DXDP) Free IP-PT Slot SLT DPT(DXDP) Total System Total Free LCOT Slot BRI PRI IP-GW TDA100 (reference) w/o MEC (Max. No. of User is 64) PSU-S PSU-M 64 0 64 64 64 64 120 96 96(48BRI) 120(4PRI) 64 w/MEC PSU-S 96 0 96 64 64 96 120 96 96(48BRI) 120(4PRI) 64 PSU-M 160 0 96 96 128 160 120 96 96(48BRI) 120(4PRI) 64 TDA100D Regardless MEC New PSU (Built-in) 176 (*) 4 (8) 112 128 96(96) 168 126 (**) 112 112(56BRI) 120(4PRI) 64 (*) TDA100D: In case of PT configuration : Max. 176 extensions with 104 DPT(DXDP) + 48 IP-PT + 24SLT (**) Max. 126 trunks with one PRI30 + 96 LCOT. When installing T1, E1, PRI30, or PRI23 cards, make sure that the number of these cards X 2 + the number of other cards (including IP-GW4E cards) does not exceed 8. 12 3. Improvements from Current KX-TDA100 Solutions >> New SLC24/16 Card (MCSLC24/MCSLC16) with CID and MW lamp Provide New 24/16 ports SLT interface card with built-in Caller ID and Message Waiting Lamp control. With this card, users can expand the number of SLT extensions up to 128. (Cannot use DLC4 on MPR cards.) Configuration Example Slot TDA100 w/PSU-M TDA100D w/new PSU TDA100D w/new PSU MPR - 4DPT I/F - 1 DHLC8 New MCSLC24/MCSLC16 New MCSLC24 2 SLC16 New MCSLC24/MCSLC16 New MCSLC24 3 SLC16 New MCSLC24/MCSLC16 New MCSLC24 4 SLC16 New MCSLC24/MCSLC16 New MCSLC24 5 SLC16 New MCSLC24/MCSLC16 New MCSLC16 6 (Trunk) (Trunk) New MCSLC16 7 - (OPB3) (Trunk) SLT Total 72 120 128 Specifications - 24/16 SLT ports per card - Max. 5 MCSLC24/Max.7 MCLSC16 cards per PBX - 2 Power Failure Transfer (PFT) ports - Built-in Caller ID (FSK) & Message Waiting Lamp Control * Caller ID specification is similar to current CSLC16. * Message waiting Lamp specification is similar to current MSLC16. * No self diagnostic function by PCMC 13 3. Improvements from Current KX-TDA100 Solutions >> New 8-port Analog CO Card with 8-port expansion Provide New 8-port Analog CO line interface card with 8-port expansion board. New card will support CID functions as a standard. Accordingly, this card will provide flexible system expansion capability and low-cost installation for users that require CID. Built-in Caller ID circuit Built-in Caller ID Circuit 2 PFT ports Mount to Base board 8-port base LCOT card Specifications 8–port expansion daughter card - 8 analog trunk ports per card - Expand up to 16 ports with 8 ports daughter card - 2 power failure transfer (PFT) ports for 8 / 16 ports - Built-in Caller ID - Pay tone detection is not available - User-supplied Amphenol connector I/F 14 3. Improvements from Current KX-TDA100 Solutions >> New MPR Card for TDA100D Built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F for easy and cost effective installation. Users who mainly use SLT do not need to purchase DHLC cards at the initial installation. In addition, - Expand SRAM capacity for supporting SMDR data registration up to 2500 calls - I/F for two Music On Hold input ports and two External Pager output connectors will be changed to a RJ45. - Serial Interface (RS-232C) port will be mounted on MPR card Note: 1. System will not work correctly when a new MPR card is installed to an existing TDA/TDE shelf. But no safety issues will occur. 2. Exchange cable, from MOH/Pager mini jack to RJ45, will not be provided. TDA100 MPR New TDA100D MPR RJ11 For DLC 4 Ports SCALE-UP RJ45 For MOH x2 & Pager x2 RS-232C For SMDR FRONT VIEW SIDE VIEW FRONT VIEW 15 3. Improvements from Current KX-TDA100 Solutions >> New Shelf and Power Supply Unit for TDA100D A new shelf with built-in Power Supply Unit (PSU) is provided. New power supply supports up to 128 load figure including max.104 for DPT/CS (see below). Therefore, users do not need to replace PSU when expanding the system. In this respect, TDA100D will cover TDA200 user range. Note: 1. Power supply and Shelf will be a new design, so there will be some incompatibility with the existing TDA/TDE series. 2. Current PSU-S/M (TDA0108/TDA0104) will not be used for TDA100D. 3. System will not work correctly when existing TDA/TDE MPR cards are installed in to a new TDA100D shelf. In this case, no safety issues will occur. Calculate the load figure from the type of equipment to be connected. Type System Total Maximum Load Figure (DPT, CS and SLC card) DPT and CS New PSU-S (Built-in) Add 7th Slot Type PT SLT card New Shelf and Power Supply CS 128 104 Load Figure DPT (DT300, T7600) 1 IP-PT 0 New MCSLC24 24 New MCSLC16 16 2-4ch CS 4 8ch CS 8 16 4. System Configuration 17 4. System Configuration Solutions >> Optional Card / Unit Trunk <Option> Total LCOT4 LCOT8 LCOT16 CLCOT8 CLCOT8E DID8 E&M8 BRI4 BRI8 T1 E1 PRI30 PRI23 IP-GW4 IP-GW4E IP-GW16 CS Max. Number of card/unit TDA100 TDA200 TDA100D 6 (*1) 8 (*1) 7 (*1) 6 8 7 - - 7 6 8 7 4 4 4 4 4 4 CS(2-4ch) 32 32 26 CS(8ch) 16 16 13 <Option> Ext Total 4DPT I/F on MPR DLC8 DLC16 IP-EXT16 DHLC8 SLC8 SLC16 CSLC16 MSLC16 New MCSLC24 New MCSLC16 CSIF4 CSIF8 CTI-LINK OPB3 MSG4 ESVM2 ESVM4 DPH4 DPH2 EIO4 ECHO16 Max. Number of card/unit TDA100 TDA200 TDA100D 6 8 7 1 6 8 7 6 8 - 4 4 5 7 4 1 4 1 4 1 4 4 4 4 4 8 4 2 4 8 4 2 4 8 4 2 (*1) One T1, E1, PRI30, PRI23, or IP-GW4 card counts as 2 cards. 18 4. System Configuration Solutions >> SLT Max. Capacity Comparison TDA100 PSU-S PSU-M Extension System Total MPR DPT(DXDP) Slot SLT 64 0 64 96 0 96 TDA200 PSU-M PSU-L 128 0 128 TDA100D New PSU 128 0 128 128 4 (8 w/DXDP) 120 0 128 Analog CO 128 112 96 TDA100 w/ PSU-M & MEC TDA200 w/ PSU-M TDA100 w/ PSU-S 48 Expanded SLT capacity 32 16 0 64 96 120 128 SLT <CO and SLT capacity chart > 19 5. Compatibility between TDA100D and TDA/TDE 20 5. Compatibility between TDA100D and TDA/TDE Solutions >> New Cards for existing TDA/TDE system Model Description TDE100/200 TDA100/200 MPR V3 MPR V5 MPR Software - MPR Software of TDA100D No No MPR Card - MPR card of TDA100D (w/ DLC4) No No Trunk Cards Extension Cards Power Supply Unit KX-TDA1180 8-Port Analogue Trunk Card with CID (CLCOT8) No (in future) No KX-TDA1186 8-Port Analogue Trunk with Caller ID daughter Card (CLCOT8E) No (in future) No KX-TDA1178 24-Port Single Line Telephone Card w/ Caller ID & MW Lamp control (MCSLC24) No (in future) No KX-TDA1176 16-Port Single Line Telephone Card w/ Caller ID & MW Lamp control (MCSLC16) No (in future) No New S-Type Power Supply Unit (new PSU-S) No No - 21 5. Compatibility between TDA100D and TDA/TDE Solutions >> Existing Card for TDA100D (1/3) MPR Software Optional SD Memory Cards MPR Card MPR Option Card Trunk Cards Model KX-TDA0820 KX-TDA0920 Description MPR Software of TDA100/200 SD Memory Card for Software Upgrade SD Memory Card for Software Upgrade to Enhanced Version KX-TDA0105 KX-TDA0196 KX-TDA0180 KX-TDA0181 KX-TDA0182 KX-TDA0183 KX-TDA0184 KX-TDA0187 KX-TDA0188 KX-TDA0189 KX-TDA0193 KX-TDA0284 KX-TDA0288 KX-TDA0290CE KX-TDA0290 KX-TDA0480 KX-TDA0484 KX-TDA0490 MPR card of TDA100/200 or TDE100/200 Memory Expansion Card (MEC) Remote Card (RMT) 8-Port Analogue Trunk Card (LCOT8) 16-Port Analogue Trunk Card (LCOT16) 8-Port DID Card (DID8) 4-Port Analogue Trunk Card (LCOT4) 8-Port E & M Trunk Card (E&M8) T-1 Trunk Card (T1) E-1 Trunk Card (E1) 8-Port Caller ID/Pay Tone Card (CID/PAY8) 8-Port Caller ID Card (CID8) 4-Port BRI Card (BRI4) 8-Port BRI Card (BRI8) PRI Card (PRI30) PRI Card (PRI23) 4-Channel VoIP Gateway Card (IP-GW4) 4-Channel VoIP Gateway Card (IP-GW4E) 16-Channel VoIP Gateway Card (IP-GW16) TDA100D No No Yes(*1) No(*2) No (*3) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes (*1): KX-TDA0920 will be updated before TDA100D released, (*2): Existing TDA/TDE MPR card will be able to install TDA100D KSU physically, but function will not work properly. (*3): DMPR support 2500 SMDR data registration, so that No MEC card support is needed 22 5. Compatibility between TDA100D and TDA/TDE Solutions >> Existing Card for TDA100D (2/3) Extension Cards Other Cards Model KX-TDA0143 KX-TDA0144 Description 4 Cell Station Interface Card (CSIF4) 8 Cell Station Interface Card (CSIF8) TDA100D Yes Yes KX-TDA0170 KX-TDA0171 KX-TDA0172 KX-TDA0173 KX-TDA0174 8-Port Digital Hybrid Extension Card (DHLC8) 8-Port Digital Extension Card (DLC8) 16-Port Digital Extension Card (DLC16) 8-Port Single Line Telephone Extension Card (SLC8) 16-Port Single Line Telephone Extension Card (SLC16) KX-TDA0175 KX-TDA0177 16-Port Single Line Telephone Card with MW Lamp (MCSLC16) 16-Port Single Line Telephone Card with Caller ID (CSLC16) No No KX-TDA0470 KX-TDA0161 KX-TDA0162 KX-TDA0164 KX-TDA0166 KX-TDA0168 KX-TDA0190 KX-TDA0191 KX-TDA0192 KX-TDA0194 16-Channel VoIP Extension Card (IP-EXT16) 4-Port Door phone Card (DPH4) 2-Port Door phone Card (German Type) (DPH2) 4-Port External Input/Output Card (EIO4) 16-Channel Echo Canceller Card (ECHO16) Extension Caller ID Card (EXT-CID) Optional 3-Slot Base Card (OPB3) 4-Channel Message Card (MSG4) 2-Channel Simplified Voice Message Card (ESVM2) 4-Channel Simplified Voice Message Card (ESVM4) Yes Yes Yes Yes Yes No Yes Yes Yes Yes KX- TDA0410 CTI Link Card (CTI-LINK) Yes No Yes(*1) Yes(*1) No No (*1): KX-TDA0171,0172 LPR Software will be updated before TDA100D released, so that when users use these existing cards for TDA100D, users must update to new software 23 5. Compatibility between TDA100D and TDA/TDE Solutions >> Existing Card for TDA100D (3/3) Power Supply Units (PSUs) Cell Stations (CSs) 2.4GHz DECT DECT 6.0 Proprietary Equipment Model KX-TDA0103 KX-TDA0104 KX-TDA0108 KX-TDA0141 KX-TDA0142 KX-TDA0151 KX-TDA0152 KX-TDA0141CE KX-TDA0142CE KX-TDA0155CE KX-TDA0156CE KX-TDA0158CE KX-T0155 KX-TDA0156 KX-T0158 KX-A228 KX-A229 KX- A258 KX-T30865 KX-T7765 Description L-Type Power Supply Unit (PSU-L) M-Type Power Supply Unit (PSU-M) S-Type Power Supply Unit (PSU-S) 2-Channel CS Using a DHLC/DLC Card for 2.4 GHz PS 3-Channel CS Using a CSIF Card for 2.4GHz PS 2-Channel CS Using a DHLC/DLC Card for 2.4 GHz PS 3-Channel CS Using a CSIF Card for 2.4GHz PS 2-Channel CS Using a DHLC/DLC Card for DECT PS 4-Channel CS Using a CSIF Card for DECT PS 2-Channel CS Using a DHLC/DLC Card for DECT PS 4-Channel CS Using a CSIF Card for DECT PS 8-Channel CS Using a DHLC/DLC Card for DECT PS 2-Channel CS Using a DHLC/DLC Card for DECT 6.0 PS 4-Channel CS Using a CSIF Card for DECT 6.0 PS 8-Channel CS Using a DHLC/DLC Card for DECT 6.0 PS S/M-type Back-up Battery Cable L-type Back-up Battery Cable Blank Slot Cover Door Phone Door Phone TDA100D No No No No No Yes Yes No No Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes 24 5. Compatibility between TDA100D and TDA/TDE Solutions >> Terminal Compatibility for TDA100D (1/2) Model DPT Description TDA100D DT300 DT346 6Line-LCD, with Backlight, 12CO, USB, Bluetooth optional Yes Series DT343 3LIne-LCD, with Backlight, 12CO, USB, Bluetooth optional Yes DT333 3Line-LCD, No Backlight Yes DT321 1Line-LCD, 8CO Yes DT390 DSS console Yes T7600 T7636 6Line-LCD, with Backlight, 12CO, USB Optional Yes Series T7633 3LIne-LCD, with Backlight, 12CO, USB Optional Yes T7630 3Line-LCD, No Backlight Yes T7668 1Line-LCD Yes T7667 1Line-LCD, No Backlight, 12CO Yes T7665 1Line-LCD, No Backlight Yes T7625 No-LCD Yes T7640 DSS console Yes T7500 series No T7400 series No T7200 series No 25 5. Compatibility between TDA100D and TDA/TDE Solutions >> Terminal Compatibility for TDA100D (2/2) Model APT Description TDA100D T7700 series No T7300 series No T7100 series No T7000 series No PT T7710 No-LCD, Message Lamp Yes PS DECT TCA155,TCA256,TCA355, CA175、TCA275, etc. Yes DECT6.0 TD7685,TD7695, TD7996 Yes 2.4G TD7684,TD7694, etc. Yes TVM200 TDA100D supports two VM system (12port/24ch) Yes TVM50 TDA100D supports two VM system (3port/6ch) Yes Voice Mail Note: There will be some differences between TDA100D and existing TDA/TDE series as follow. 1) SMDR and HOTEL information registration capacity will be increased up to 2500. 2) Broadcasting (Announcement to 31 members) will be activated without MEC. 26 6. New PCMC 27 6. New PCMC Solutions >> Dedicated PCMC for TDA100D "Multi-Site PBX Manager“ not supported Displayed only as the "TDA100D" icon in the "New" window. 28 End of Document 29