NAESA REGIONAL WORKSHOP
PRESENTATION
A17 Code Required
Data Plates, Tags and Signs
by: John S. Rearick
CodeDataPlate.com
CodeDataPlate.com
New in 2007 edition and in a-2008
•
•
•
•
•
•
•
•
2.7.5.2.1 MRL Pit Signage
3.18.6 Marking of HY Jack
8.10.2.2.2 Governor
8.10.4.1 Escalator Governor
8.11 Requirements moved to 8.6 (‘08)
8.9.2 Added Esc. Code Data Plate
Others in Parts 5, 6 and 7
Also changes for those enforcing NBCC (Canada)
CodeDataPlate.com
Violations
• A17.1-2000 and later editions Part 8
8.6.1.6.7 Signs and Data Plates. Required signs
and data plates that are damaged or missing shall be
repaired or replaced.
8.6.1.5 Code Data Plate
8.6.1.5.1 A data plate that indicates the Code
and edition in effect at the time of installation and any
alteration (see 8.7.1.8) shall be provided. The data plate
shall also specify the Code and edition in effect at the
time of any alteration and the applicable requirements
of 8.7.
8.6.1.5.2 The Code data plate shall comply
with 8.9.
• A17.3-1996 and later editions
3.5.6 Rail Lubricants and Lubrication Plate
…A metal plate shall be securely attached to the car crosshead…
CodeDataPlate.com
Data Plates
• A17.1 Requirements
–
–
–
–
–
–
–
–
–
Counterweight Runby Data Plate
Crosshead Data Plate
Capacity Plate
Safety Marking Plate
Jack Marking Plate
Rail Lube Plate
Governor Marking Plate
Brake Marking Plates
Buffer Marking Plate
CodeDataPlate.com
More Data Plates
• A17.1 Requirements (Continued)
–
–
–
–
–
–
Plunger Gripper Marking Plate
Hydraulic Machine & Valve Data Plates
Escalator/Moving Walk Brake Data Plates
Chain Data Plates (Dumbwaiter)
Rack & Pinion Data Plate
Code Data Plate
• A17.3 Requirements
– Rail Lube Plate
– Capacity Plate
CodeDataPlate.com
Tags
• A17.1 Tags
–
–
–
–
–
–
Governor Rope Tag
Hoist Rope Data Tag
Acceptance Safety Test Tag
Resocketing Tag
Escalator Governor
Periodic Test Tags
• A17.3 Tags
– Hoist Rope Data Tag
– Chain Data Tag
CodeDataPlate.com
Signs
• A17.1 Signs
–
–
–
–
–
–
–
–
Bottom Car Clearances
Refuge Space on Top of Car Enclosure
Working Areas in the Car or on the Car Top
Working Areas in the Pit
Location of Equipment - Governor Servicing
Freight Car Signage
Anti-creep Operation
Fire Service Signage
CodeDataPlate.com
More Signs
• A17.1 Signs (Continued)
–
–
–
–
Emergency Brake Sign
No Jumper Sign adjacent to Bypass Switches
Escalator & Moving Walk Caution Signs
Additional (Esc. & M.W.) Signs
• A17.3 Signs
– Freight Car Signs
– Escalator Caution Signs
– D/W “No Riders” Signs
CodeDataPlate.com
2.4.5 Counterweight Runby Data Plate
A data plate permanently and securely attached shall
be provided in the pit, in the vicinity of the counterweight
buffer, indicating the maximum designed counterweight
runby. The data plate shall conform to 2.16.3.3,
except that the letters shall be not less than 25 mm (1 in.)
in height.
MAXIMUM
COUNTERWEIGHT
RUNBY 24"
CodeDataPlate.com
2.6.5.2 (<‘04) or 2.7.9.2 (’S-05>)
T E M P E R A T U R E -H U M ID IT Y D A T A P L A T E T E M P L A T E - S T A N D A R D
R e q u ire m e n t 2 .7 .5 .2 ( 2 .7 .9 .2 in A 1 7 .1 -2 0 0 7 )
N E II-1 R a n g e s s h o w n w h ic h is tig h te r th a n m o s t m a n u fa c tu re s '
C u s to m ra n g e s a va ila b le o n s p e c ia l o rd e r
A m b ie n t A ir R e q u ire m e n ts
T e m p e ra tu re
o
o
1 3 C (5 5 F )
R e la tive H u m id ity
80%
M in .
o
o
3 2 C (9 0 F )
M ax.
M ax.
c o d e d a ta p la te .c o m
N o te : Ap p ro x im a te P la te s iz e is 5 .5 " x 1 .5 " w ith .1 2 5 " le tte rin g .
2 .7 .9 .2 T e m p e ra tu re a n d H u m id ity. M ach in ery
sp aces, m ach in e ro o m s, co n tro l sp aces, and co n tro l
ro o m s sh all b e p ro vid ed w ith n atu ral o r m ech an ical
m ean s to keep th e am b ien t air tem p eratu re an d h u m id ity
in th e ran ge sp ecified b y th e elev ato r eq u ip m en t
m an u factu rer to en su re safe and no rm al o p eratio n of
th e elevato r. T h e tem p eratu re an d h u m id ity ran ge sh all
b e p erm an en tly p o sted in th e m ach in e roo m , co n tro l
ro o m , co n tro l sp ace, o r w h ere sp ecified b y th e eq u ip m en t
m an u factu rer, in th e m ach in ery sp ace.
CodeDataPlate.com
2.13.4.2.4 Door Operator Plate
●
●
DOOR OPERATOR DATA PLATE
NORMAL
Seconds
REDUCED
Seconds
●
cdp
●
D o o r O p era tor P late re q u ire d w h e n R e-O p e nin g D e vic e is altere d /a d d e d
8 .7 .2 .1 3 D o o r R e o p e n in g D e v ic e . W here a reopening device … is altered... requirem ents
shall apply: (a) require m e nt 2.13.4…
2 .1 3 .4 .2 .4 D a ta P la te . A data plate conform ing to 2.16.3.3
Instructions Provided
CodeDataPlate.com
CROSSHEAD DATA PLATE TEMPLATE - HY
For use for Hydralic elevators installed under A17.1b-1995 and earlier editions
●
●
Under b-1995 and earlier
CROSSHEAD DATA PLATE
COMPLETE CAR WEIGHT:
Hydro
POUNDS
RATED LOAD:
F.P.M.
RATED SPEED:
MANUFACTURED:
BY:
Under 1996 CROSSHEAD
and later
DATA● PLATE TEMPLATE - HY
●
Note: Approximate Plate size is 7" x 2.75" with .125" lettering.
●
●
CROSSHEAD DATA PLATE
QUANTITY
COMPLETE CAR WEIGHT:
1
4 HOLES X
2.16.3.2.2
and
3.16.3
POUNDS
CAR #'s
PLUNGER WEIGHT:
POUNDS
APPROVED
RATED LOAD:
DOWN SPEED:
F.P.M.
DATED
P.O. #
BY:
MANUFACTURED:
RAIL LUBRICATION INSTRUCTIONS:
Work order #
●
X
DOUBLE FACED TAPE
1106-02
●
CROSSHEAD DATA PLATE TEMPLATE
- TR
A17.1-1990 Rule 301.10 = speed is down direction and is not to include weight of plunger
this seems to be a clarification - the referance is still back to Section 207
Traction
●
A17.1 Req.
8.6.1.6.7
only
●
CROSSHEAD DATA PLATE
COMPLETE CAR WEIGHT:
RATED LOAD:
POUNDS
POUNDS
RATED SPEED:
NUMBER OF ROPES:
DIAMETER:
RATED BREAKING STRENGTH:
MANUFACTURED:
not in A17.3
F.P.M.
IN.
POUNDS
BY:
RAIL LUBRICATION INSTRUCTIONS:
the safety
for the characteristics of the rail lubricant to be used.
CodeDataPlate.com
●
●
Jack, Safety Plank & Capacity
Marking of Hydraulic Jack
The exposed portion of each hydraulic
jack after installation shall be plainly
marked in a permanent manner with
the following:
(a) the name or trademark by which
the organization that manufactured the
hydraulic jack can be identified
(b) the manufacturer’s designation of the
type or model
(07)
(c) year of manufacture
Marking Plates for Safeties
A metal plate shall be securely attached to each
safety
so as to be readily visible, and shall be marked in a
legible and permanent manner with letters and figures
not less than 6 mm (0.25 in.) in height indicating:
(a) the type of safety, based on 2.17.5
(b) the maximum tripping speed in m/s (ft/min) for
which the safety is permitted
(c) the maximum weight in kg (lb), that the safety is
designed and installed to stop and sustain
(d) the force in N (lbf) required to activate the safety
or rope releasing carrier, if provided
(e) the manufacturer’s name or trademark
Hydraulic (3.18.6)
●
●
CAPACITY
●
2500
POUNDS
Traction (2.17.14)
●
CodeDataPlate.com
Other Hydraulic Markings
3 .1 9 .1 .4 C o m p o n e n t M a rk in g s
V a lve s, fittin g s, a n d m u ffle rs sh a ll b e p re ssu re ra te d , a n d sh a ll b e a r th e
m a n u fa ctu re r’s n a m e o r tra d e m a rk b y w h ich th e o rg a n iza tio n th a t m a n u fa ctu re d
th e p ro d u ct ca n b e id e n tifie d a n d id e n tifica tio n sym b o ls to in d ica te th e m a te ria ls
a n d se rvice d e sig n a tio n s fo r w h ich th e m a n u fa ctu re r’s ra tin g a p p lie s.
3 .1 9 .2 .5 H yd ra u lic P ip e lin e Id e n tific a tio n
A m a rkin g sh a ll b e a p p lie d , to a cce ssib le p ip in g th a t is lo ca te d o u tsid e th e
e le va to r m a ch in e ro o m o r h o istw a y, sta tin g “E le va to r H yd ra u lic L in e ” in le tte rs
th a t a re a t le a st 1 9 m m (0 .7 5 in .) h ig h in a co n tra stin g co lo r. T h e m a rkin g sh a ll b e
visib le a fte r in sta lla tio n a n d a p p lie d a t in te rva ls n o t g re a te r th a n … 1 2 0 in ..
3 .1 9.4 .4 M a n u a l L ow erin g V a lve
… sh a ll b e p ro vid e d an d id e ntifie d … . T h is va lve sh a ll b e so m a rke d to ind ica te
th e lo w e rin g p o sitio n .
CodeDataPlate.com
Safety Test Tag
●
Car Safety Test - 8.10.2.2.2
Person or Firm Performing Test:
Acceptance Test
Date:
cdp
●
8.10.2.2.2 (ii)(1)(f) A metal tag with the rule number, test date, and
name of the person/firm performing the test shall be attached to
the releasing carrier or where the governor rope attaches to the
safety.
CodeDataPlate.com
GOV PULL-THROUGH TEST █
By:
HY FLEX HOSE █
● INSTALLED
█
BUFFER TEST █
TESTED
█
●
JAN █
FEB █
MAR █
APR █ MAY █
JUN █
JUL █
AUG █
SEP █
OCT █ NOV █
DEC █
2007█
2008█
2009 █
2010█
2012█
2011█
cdp
8.6.3.4.4 A test tag indicating the date when the pull-through test was
performed shall be attached.
8.11.2.3.3 (e) After completion of the test (of the oil buffer), a metal tag,
indicating the date of the test, together with the name of the person or firm
who performed the test, shall be attached to the the test.
8.6.5.6 Flexible Hoses...shall be replaced not more than 6 years beyond the
installation date. Existing hose assemblies that do not indicate an installation
or replacement date shall be replaced….
CodeDataPlate.com
Pullthru
+
Buffer
+
Flex
Hose
Test
Tag
●
●
RAIL LUBRICATION INSTRUCTIONS:
DO NOT LUBRICATE
●
cdp
●
For Roller Guides
A17.1 - 2.17.16 & A17.3 - 3.5.6
For Slide Guides
In A17.1-2000 and
later editions this
information must be on
Crosshead Data Plate
●
●
RAIL LUBRICATION INSTRUCTIONS:
CONSULT MANUFACTURER OF THE SAFETY FOR
THE CHARACTERISTICS OF THE RAIL LUBRICANT
TO BE USED
●
CodeDataPlate.com
cdp
●
2.18.9 - Governor Plate
●
●
SPEED-GOVERNOR MARKING PLATE
●
TRIPPING SPEED:
F.P.M.
395
ROPE SIZE:
IN. MATERIAL: IRON
1/2
CONSTRUCTION:
8 X 25
PULL-THROUGH:
POUNDS
400
MANUFACTURED BY:
HAUGHTON
DO NOT LUBRICATE GOVERNOR ROPE
CodeDataPlate.com
●
Brakes Plates
• 2.19.3.3
• 2.24.8.5
The emergency brake shall
be provided with a marking
plate indicating the range of
total masses (car with attachments and its load) for which
it is permitted to be used,
the range of speeds at which
it is set to operate, and the
criteria such as rail lubrication
requirements that are
critical to the performance.
The brake setting and
method of measurement
shall be permanently and
legibly marked on the
driving machine.
CodeDataPlate.com
Buffer Marking Plates
●
●
BUFFER MARKING PLATE
LOAD RATING:
6000
8 items
POUNDS
Every installed oil buffer shall have permanently attached
STROKE: thereto a metal plate,
2 marked
1/2
INCHES
by the manufacturer in a legible
and
permanent
NUMBER OF
SPRINGS:
2
manner,
indicating
●
CDP
●
2.22.2.3
and
2.22.4.11
(for Oil Buffers)
(a) the maximum and minimum loads and the maximum
striking speeds for which the buffer has been rated for use in
conformance with the requirements in 2.22
(b) the permissible range in viscosity of the buffer oil
to be used, stated in Saybolt Seconds Universal at 38°C
(100°F)
(c) the viscosity index number of the oil to be used
(d) the pour point in degrees Celsius (Fahrenheit) of
the oil to be used
(e) the stroke of the buffer in mm (in.)
(f) the composition of the gas, if used
(g) the name, trademark, or file number by which
the organization that manufactured the product can be
identified
(h) the certification marking in accordance with
8.3.1.3
CodeDataPlate.com
2.22.3.3
8.6.1.6.7 Check for any Missing or
Damaged Signs and Data Plates
• Machine Room
–
–
–
–
–
–
Brake Plates
Governor Plate
Code Data Plate
Ambient Air Plate
Hydro Data Plates
Warning Signs
• Fire Service Signs
• Hoistway and Pit
–
–
–
–
–
–
Crosshead Data Plate
Rail Lube Instructions
Warning Signs
Safety Plank Plate
Buffer Plate
Counterweight Runby
• Freight & Capacity
CodeDataPlate.com
Inspection Tags
• Acceptance Tests
– 8.10 Requirements
– New Installations
– Alterations
• Periodic
– 8.11 Requirements
– 8.11.1.6 Tag
– New under b-2008:
• Testing moves to 8.6
CodeDataPlate.com
TN 02-3392
Proposed revision to ASME A17.1 – 2000 requirements 8.11 for test tags as follows:
8.11.1.6 Periodic Test Tags. A metal test tag with the test date; the requirement number
requiring the test, the applicable code requirement(s) and date performed; and the name
of the person or firm performing the test; shall be installed in the machine room or
machine space for all Category 3 and 5 periodic tests for electric elevators and Category
1, 3, and 5 tests for hydraulic elevators.
8.11.2.3.1 Car and Counterweight Safeties.
(b) For Type A safeties .......
A metal tag shall be attached to the safety-releasing carrier in a permanent manner,
giving the date of the safety test, together with the name of the person or firm who
performed the test.
8.11.2.3.3 Oil Buffers
(e) After completion of the test, a metal tag, indicating the date of the test, together with
the name of the person or firm who performed the test, shall be attached to the buffer
[Item 5.3.2(b)].
8.11.3.2.4 Flexible Hose and Fitting Assemblies.
Flexible hose and fitting assemblies shall be tested at the relief valve setting pressure for
a minimum of 30 s. Any signs of leakage, slippage of hose fittings, damage to outer hose
CodeDataPlate.com
covering sufficient to expose reinforcement,
or bulging, or distortions of the hose body is
cause for replacement. A metal tag indicating the date of the test and the name of the
TN 02-3392
8 .1 1 .3 .2 .4 F lexib le H o se a n d F ittin g A sse m b lies.
F lexib le ho se and fittin g assem b lies sha ll b e tested at the relie f va lve se tting p ressure fo r
a m inim u m o f 3 0 s. A n y sig ns o f lea ka ge, slip p age o f ho se fittin gs, d a m a ge to o uter ho se
co verin g sufficie nt to exp o se reinfo rce m ent, o r b ulgin g, o r d isto rtio ns o f the ho se b o d y is
cause fo r rep lacem e nt. A m etal ta g ind icatin g the d ate o f the te st and the na m e o f the
p erso n o r firm w ho p erfo rm ed the test shall b e attached to the ho se asse m b ly in a
p erm a ne nt m a n ner (Ite m 2 .1 7 .2 ).
C autio n: If the m o to r p ro tectio n o r m o to r o verlo ad s trip d uring this te st d o N O T change
the ad justm ent o r ju m p er the o verlo ad s. D a m a ge to the m o to r can result fro m ru n ning the
m o to r w itho u t ad eq uate o verlo ad p ro tectio n.
R E A S O N : C la rifica tion and co nso lid ation of th e requirem ents fo r
p erio dic insp ectio ns and test ta gs… . T h e original in tent w a s it to
a pply to ca tego ry 1 a nd 5 .
P ublic R eview D raft June 2006
A 17.1-200x P roposed R evisions
CodeDataPlate.com
P age 27 o f 197
T ra c tio n E le v a to r - P e rio d ic T e s t R E Q . T a g
P e rs o n o r F irm P e rfo rm in g T e s t:
T e s t C a te g o ry:
REQ. #
8 .1 1 .2 .2 .1
8 .1 1 .2 .2 .2
8 .1 1 .2 .2 .3
8 .1 1 .2 .2 .4
8 .1 1 .2 .2 .5
8 .1 1 .2 .2 .6
8 .1 1 .2 .2 .7
8 .1 1 .2 .2 .8
8 .1 1 .2 .2 .9
8 .1 1 .2 .2 .1 0
8 .1 1 .2 .2 .1 1
T e s t Ite m
C a r a n d C W O il B u ffe r
C a r & C W T S a fe tie s
C a r & C W T G o ve rn o rs
W in d in g D ru m S la ck R o p e D e vic e
T e rm in a l S to p p in g D e vic e s
E m e rg e n c y O p e ra tio n s F F S
S ta n d b y P o w e r O p e ra tio n
D o o r C lo s in g F o rc e & K E
B ro k e n R o p e o r T a p e S w itc h
E /E /P E S c h e c ko u t
A s c e n d in g C a r/U n in te n d e d
M o tio n T e s ts
CodeDataPlate.com
1
T e s t D a te
T ra c tio n E le v a to r - P e rio d ic T e s t R E Q . T a g
P e rs o n o r F irm P e rfo rm in g T e s t:
T e s t C a te g o ry:
REQ. #
8 .1 1 .2.3 .1
8 .1 1 .2.3 .2
8 .1 1 .2.3 .3
8 .1 1 .2.3 .4
8 .1 1 .2.3 .5
8 .1 1 .2.3 .6
8 .1 1 .2.3 .7
8 .1 1 .2.3 .8
8 .1 1 .2.3 .9
8 .1 1 .2.3 .10
8 .1 1 .2.3 .10
T e s t Ite m
C a r & C W T S a fe ties
C a r & C W T G o ve rn o rs
C a r a n d C W O il B u ffe r
B ra k ing S ys tem (12 5 % )
S ta n d b y P o w e r O p e ra tio n
E m e rg en c y a nd T e rm ina l S pe e d
L im iting D e vic es
P o w e r O p e n in g of D o o rs
L e ve ling Z on e an d S pe e d
In n e r la n din g Z o n e
E m e rg en c y S top p ing D is ta nc e
T ra c tio n T e s t
CodeDataPlate.com
5
T e s t D a te
Hydraulic Elevator - Periodic Test REQ. Tag
Person or Firm Performing Test:
Schindler Elevator Corporation
Test Category:
REQ. #
8.11.3.2.1
8.11.3.2.2
8.11.3.2.3(a)
8.11.3.2.3(b)
8.11.3.2.3(c)
8.11.3.2.3(d)
8.11.3.2.3(e)
8.11.3.2.3(f)
8.11.3.2.3(g)
8.11.3.2.3(h)
8.11.3.2.3(i)
8.11.3.2.4
8.11.3.2.5
Test Item
Relief Valve & System
Pressure
Cylinder & Pressure Piping
Normal Terminal Stopping
Device
Governors
Safeties
Oil Buffers
Emergency Operation FFS
Standby Power Operation
Power Operation of Doors
Terminal Speed Reducing
Low Oil & RPR Protection
Flexible Hose & Fitting
Pressure Switch
CodeDataPlate.com
1
Test Date
cd
H yd ra u lic E le v a to r - P e rio d ic T e s t R E Q . T a g
P e rs o n o r F irm P e rfo rm in g T e s t:
T e s t C a te g o ry:
REQ. #
8 .1 1 .3.4 .1
8 .1 1 .3.4 .1
8 .1 1 .3.4 .1
8 .1 1 .3.4 .4
8 .1 1 .3.4 .5
T e s t Ite m
G o ve rn o rs
S a fe ties
O il B u ffe rs
P lu n g e r G rip pe r
O ve rs p e e d V a lve s
CodeDataPlate.com
5
T e s t D a te
E s c a la to rs – P e rio d ic T e s t R E Q . T a g
P erso n o r F irm P erfo rm ing T est:
A M T E C H E leva to r S ervices
T e s t C a te g o ry:
REQ. #
8 .1 1 .4 .2 .1
8 .1 1 .4 .2 .2
8 .1 1 .3 .2 .3
8 .1 1 .4 .2 .4
8 .1 1 .4 .2 .5
8 .1 1 .4 .2 .6
8 .1 1 .4 .2 .7
8 .1 1 .4 .2 .8
8 .1 1 .4 .2 .9
8 .1 1 .4 .2 .1 0
8 .1 1 .4 .2 .1 1
8 .1 1 .4 .2 .1 2
8 .1 1 .4 .2 .1 3
8 .1 1 .4 .2 .1 4
8 .1 1 .4 .2 .1 5
8 .1 1 .4 .2 .1 6
8 .1 1 .4 .2 .1 7
8 .1 1 .4 .2 .1 8
8 .1 1 .4 .2 .1 9
8 .1 1 .4 .2 .2 0
8 .1 1 .4 .2 .2 1
8 .1 1 .4 .2 .2 2
1
T est Item
M a c h in e S p a c e A c c e s s
M a c h in e S p a c e S to p S w itc h
C o n tro lle r W irin g a n d F u s e s
B ra k e T o rq u e T e s t
S p e e d G o ve rn o r
B ro k e n D riv e C h a in D e vic e
R e v e rs a l S to p D e vic e
B ro k e n S te p C h a in D e vic e
S te p U p th ru s t D e vic e
M is s in g S te p D e v ic e
S te p L e ve l D e v ic e
S te p s , C h a in a n d T ru s s e s
H a n d ra il S a fe ty S ys te m E n try D e vic e
a n d S p e e d M o n ito rin g
H e a te rs O u td o o r U n its
S tre tc h o f S te p C h a in
D is c o n n e c te d M o to r D e vic e
R e s p o n s e to S m ok e D e te c to rs
C o m b /S te p Im p a c t D e vic e
S te p /S k irt P e rfo rm a n c e In d e x
C le a ra n c e B e tw e e n S te p a n d S k irt
(L o a d e d G a p )
In s p e c tio n C o n tro ls
S te p L a te ra l D is p la c e m e n t D e vic e
T est D ate
cdp
CodeDataPlate.com
M o v in g W a lk – P e rio d ic T e s t R E Q . T a g
P erso n o r F irm P erfo rm ing T est:
T e s t C a te g o ry:
REQ. #
8 .1 1 .4 .2 .1
8 .1 1 .4 .2 .2
8 .1 1 .4 .2 .3
8 .1 1 .4 .2 .4
8 .1 1 .4 .2 .5
8 .1 1 .4 .2 .6
8 .1 1 .4 .2 .7
8 .1 1 .4 .2 .8
8 .1 1 .4 .2 .1 0
8 .1 1 .4 .2 .1 1
8 .1 1 .4 .2 .1 2
8 .1 1 .4 .2 .1 3
8 .1 1 .4 .2 .1 4
8 .1 1 .4 .2 .1 6
8 .1 1 .4 .2 .1 7
8 .1 1 .4 .2 .1 8
8 .1 1 .4 .2 .2 1
1
T est Item
M a c h in e S p a c e A c c e s s
M a c h in e S p a c e S to p S w itc h
C o n tro lle r W irin g & F u s e s
B ra k e & T o rq u e T e s t
S p e e d G o ve rn o r
B ro k e n D riv e C h a in D e vic e
R e v e rs a l S to p D e vic e
B ro k e n S te p C h a in D e vic e
M is s in g P a lle t D e v ic e
P a lle t L e ve l D e v ic e
P a lle t, C h a in a n d T ru s s e s
H a n d ra il S a fe ty S ys te m E n try D e vic e
a n d S p e e d M o n ito rin g
H e a te rs O u td o o r U n its
D is c o n n e c te d M o to r D e vic e
R e s p o n s e to S m ok e D e te c to rs
C o m b / P a lle t Im p a c t D e vic e
In s p e c tio n C o n tro ls
T est D ate
cdp
CodeDataPlate.com
Code Data Plates
• 8.9.1 Required Information
– 8.10.1.2 Applicability of Inspection and Test Requirements
• 8.9.2 Location
(07)
– Mainline or on Controller
– Additional Plate for External Escalator Inspections
• 8.9.3 Material and Construction
– ...shall remain permanently and readily legible.
CodeDataPlate.com
SECTION 8.9
Requirement 8.9 contains requirements for all new and existing
equipment within the Scope of this Code.
8.9.1 Required Information
Data plate shall be provided and maintained that shall indicate the
Code to be used for inspections and tests (see 8.10.1.2). The data plate
shall indicate the Code and edition in effect at the time of installation.
CODE DATA PLATE
INSTALLATION CODE:
ASME A17.1a-1997
codedataplate.com
The data plate shall also indicate the Code in effect at the time of
any alteration
ALTERATION CODE:
ASME A17.1a-2005
and indicate the applicable requirements of 8.7.
SECT. 8.7 REQUIREMENTS COMPLIED WITH:
#REF!
8.7.2.11.5, 8.7.3.8, 8.7.3.24, 8.7.3.29, 8.7.3.30,
8.7.3.31.2, 8.7.3.31.5, 8.7.3.31.8
CodeDataPlate.com
8.7.3.31.1,
codedataplate.com
Installation Code Edition
• Original Installation Date
– Elevator Permit Date
– Other Dates If Unknown
• Original Installation Code
– Follows AHJ’s Effective Dates
– Use ASME Effective Dates
• AHJ has no dates
• No AHJ
• GSA
– Format is the same as in Inspector’s Guide
CodeDataPlate.com
Equipment Without Alteration
• Older Installations
– Use applicable adopted A-17.1 editions
– Use locally adopted code/standards such as:
•
•
•
•
•
•
•
•
Adopted A17.3- Edition
California CA Title 8 - Group 2
Ohio Bulletin 110 (Red Book)
Iowa 875-IAC Ch. 73
Massachusetts 524 CMR
Missouri 11 CSR 40-5.065
Pennsylvania PA 34 Ch. 7
Washington WAC 296-96 Min. Std.
– Use building code referenced A17.1 edition
• New Installations
– Use applicable ASME edition as AHJ adopts
CodeDataPlate.com
Edition Sensitive Items
(85 years of code)
•
•
•
•
•
•
•
•
•
•
A17.3 applies from d-1986 through d-2000 to Part XII
Item 1.6 Car Emergency Signal there are 6 differences
Space Guards A17.1-1937 and later editions (also A17.3)
Static Control a-1988 and later editions
Glazing b-1989 and later editions & again in a-2005
Item 1.12/13 & 3.8 (Cab items) there are 16 differences
and 16 more relating to car & hoistway doors & gates
Door Restrictors b-1980, b-1983 and b-1989 differences
Hydro RPR required for installations under c-1986 and later
Fire Service b-1973, 1981, 1984, b-1989, 2000 and 2004
CodeDataPlate.com
START
Determine the Original
Maufacturer and serial
number of the base
equipment.
CDP Flow Chart
No
Determine date of
Manufacture from
Cross Head Data
Plate
Yes
Yes
Yes
Have there been
Alterations?
No
Contacted
Manufacturer to obtain
the Installation Code
Yes
No
Determine building
construction period estimate elevator
install permit date
Determine the
Modernization
Installer and Date
Subtract time from permit
to manufacture (6-18
months)
Determine code in effect
from AHJ for the
estimated permit date
Determine scope of alterations and the
applicable alteration rules and the
applicable alteration code edition
FINISH
Order Proper
Code Data Plate
CodeDataPlate.com
Install Code Data
Plate on Controller or
Main Line Disconnect
CodeDataPlate.com
CodeDataPlate.com
Job Information
Web, e-mail, phone or fax
Code
Data
Plate
Order
Form
A lteration to H oistw ay:
A scending C ar/unintended M ovem ent P rotection
H oistw ay V entilation
C hange in N um ber of R opes
M ach. R oom A ccess:
A ddition of R ope E qualizers
M ach. R m . A lteration:
A ddition of A uxiliary R ope-F astening D evices
R eplace or alter W iring
A lteration to cw t:
H orizontal S lide E ntrance(s) added
Installation of or A lteration to C w t. R oller G uides
V ertical B i-P arting E ntrance(s)
A lteration to C ar or C w t. B uffers or B um pers
T racks and/or H angers R eplaced
A lteration of G uide R ails, S upports and F astenings
Interlocks R eplaced
A lteration to M achine, M otor or S heaves
H W A ccess and/or U nlocking D evice A lteration
C hange in location of D riving M achine
D oor restrictors added
A lteration to T erm inal-S topping D evices
D oor O perator added or altered
A ddition of or alteration to T op of C ar O perating D evice
D oor R e-O pening devise added or altered
A ddition of or alteration to C ar leveling or T ruck-Z oning D evice
C om plete N ew C ab
C hange of M ain P ow er S upply
R em odel E xisting C ab:
C ontroller change
A lteration of C ar F ram e or P latform
C hange in T ype of M otion C ontrol (A C , D C , V V , S C R , etc.)
Installation of or A lteration to C ar R oller G uides
C hange in T ype of O peration C ontrol (C ar S w ., A utom atic, etc.)
Increase/D ecease D eadw eight of C ar m ore than 5%
C harge to E m ergency O perations or S ignaling devices
C hange in T ype of S ervice
Installation of new H ydraulic Jack
C hange in C lass of Loading
Install or alter P lunger
C hange to carry P assengers on F reight elevator
Install, alter or sleeve C ylinder
Increase in R ated Load
Increase W orking P ressure
Increase or D ecrease T ravel
C hange location of H ydro Jack
Increase in R ated S peed
R elocation of H ydraulic M achine to below top of C ylinder
D ecrease in R ated S peed
Installation of P lunger G ripper
R eplace or install N ew C ar S afety
C hange to V alves, P ressure P iping & F ittings
R eplace or install N ew C w t. S afety
Install or alter T ank
A lter E xisting C ar or C w t. S afety
A lter A nti-C reep Leveling device
A lter or install N ew S peed G overnor
Install or alter E m ergency Low ering
CodeDataPlate.com
O th e r ite m s m o d e rn ize d , co m m e n ts o r a n y a d d itio n a l In fo rm a tio n :_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Common Errors - Disconnect
• Change in Power Supply = 8.7.2.27.3 or 8.7.3.31.4
– Change of Voltage, Frequency or Number of Phases
– Change from DC to AC
– Change of combination of DC and AC
• Replace Wiring or Disconnect = 8.7.2.8 or 8.7.3.8
– Includes new machine room wiring, hoistway wiring
and travelling cables
– Requires conformance with Section 2.8 which includes
reference to NFPA 70 (NEC)
CodeDataPlate.com
Common Errors - Control 8.7.2.27
•
•
•
•
Install like Controller = 8.7.2.27.4 or 8.7.3.31.5
Change of Motion Ctrl. = 8.7.2.27.5 or 8.7.3.31.6
Change in Operation = 8.7.2.27.6 or 8.7.3.31.7
Related requirements
–
–
–
–
–
Top of Car Inspection = 8.7.2.27.1 or 8.7.3.31.1
Leveling = 8.7.2.27.2 or 8.7.3.31.2
Anti-creep = 8.7.3.31.3
Stop Switch = 8.7.2.27.7 (was 8.7.2.14.5 in a-2002 and earlier)
Alter an EPD = 8.7.2.27.8 or 8.7.3.31.11 (‘07)
CodeDataPlate.com
Common Errors - Jack 8.7.3.23
• Replace Jack with new Jack = 8.7.3.23.1
• Cut off head and weld onto new Cylinder,
re-use the plunger = 8.7.3.23.3
• Related requirements
–
–
–
–
–
Plunger only = 8.7.3.23.2
Change of Working Pressure = 8.7.3.23.4
Relocation of Jack = 8.7.3.23.5
Relocation of Tank = 8.7.3.23.6
Plunger Gripper = 8.7.3.23.7
CodeDataPlate.com
Custom Software
CodeDataPlate.com
Custom
Software
CodeDataPlate.com
Custom Plates
• Alterations Under A17.1-1996 Edition
CODE DATA PLATE
IN S T A L L A T IO N C O D E :
A L T E R A T IO N C O D E :
A N S I A 1 7 .1 -1 9 7 8
A S M E A 1 7 .1 a -1 9 9 4
P A R T X II R U L E S C O M P L IE D W IT H :
#REF!
1 2 0 1 .1 1 , 1 2 0 2 .1 3 .
c odedataplate.c om
• Alterations Under A17.1-2000 Edition
CODE DATA PLATE
IN S T A L L A T IO N C O D E :
A L T E R A T IO N C O D E :
A N S I A 1 7 .1 -1 9 7 8
A S M E A 1 7 .1 -2 0 0 0
S E C T . 8 .7 R E Q U IR E M E N T S C O M P L IE D W IT H :
#REF!
8 .7 .2 .1 1 .5 , 8 .7 .2 .2 8 .
c odedataplate.c om
CodeDataPlate.com
Alteration Plate
Door Operator
Plunger Gripper
CODE DATA PLATE
Wiring
INSTALLATION CODE:
Re-opening
Devise
Door Restrictor
ALTERATION CODE:
ASA A17.1-1965
Valve
ASME A17.1-2000
SECT. 8.7 REQUIREMENTS COMPLIED WITH:
#REF!
8.7.2.11.5, 8.7.2.13, 8.7.3.8, 8.7.3.12, 8.7.3.23.7, 8.7.3.24,
8.7.3.30, 8.7.3.31.1, 8.7.3.31.2, 8.7.3.31.5, 8.7.3.31.8
8.7.3.29,
codedataplate.com
Limits
Controller Replacement
Top of Car Insp..
Emergency Operations
Leveling
CodeDataPlate.com
Tank
Field Marked Alteration Plate
Covers Common Minor Alterations
CODE DATA PLATE
Re-opening
Devise
ALTERATION CODE: ASME A17.1
b-2003
-2004
-2000
a-2005
a-2002
-2007
Rope Brake
SECT. 8.7 REQUIREMENTS COMPLIED WITH:
Door
Restrictor
#REF!
8.7.2.11.5
8.7.2.13
8.7.2.14.3
8.7.2.20
8.7.2.28
8.7.3.23.1
8.7.3.23.3
8.7.3.24
8.7.3.31.8
8.7.3.31.9
cdp
Jack Replacement
Emergency
Lowering
Cylinder Only
Cab Interiors
HY
Fire Service Alterations
TR
Instructions Provided
Valve Alteration
CodeDataPlate.com
Code Data Plate Kits
CodeDataPlate.com
Thank You - Questions
CodeDataPlate.com
Download