การประชุมวิชาการด ้านการตรวจทางห ้องปฏิบต ั ก ิ ารเอชไอวี/เอดส ์ ระดับชาติ ครัง้ ที่ 3 วันที่ 11-13 กรกฎาคม 2554 ณ โรงแรมฮอลิเดย์อน ิ น์ รีเจนท์ บีช ชะอา จ.เพชรบุรี New Technologies and Innovations in Laboratory Support of HIV/AIDS Care and Treatment Sakchai Dettrairat HIV Laboratory Division of Clinical Immunology Department of Medical Technology Faculty of Associated Medical Sciences, CMU HIV/AIDS Diagnostic Landscape • Diagnostics for HIV/AIDS can be divided into 3 test categories: – Tests to facilitate initial diagnosis – Tests to stage the patient – Tests to monitor the patient, both before and after initiation of ART • HIV Diagnostic Testing • • • • Anti-HIV Antibody Test HIV p24 Antigen Test Nucleic Acid Amplification Tests (NAT) Viral Culture HIV Markers During Early Infection Theoritical Identify HIV RNA HIV p24 Ag HIV Antibody Day 0 Day 11 Day 16 Day 22 5 Days 6 Days 11 Days http://depts.washingto n.edu/labweb/Divisions /Viro/HIVTest.htm Anti-HIV Antibody Tests Screening Tests EIA or CIA Simple/Rapid Tests Confirmatory or Supplemental Tests Western Blot (WB) Immunofluorescence Assay (IFA) Time during acute infection at which positive results of diagnostic tests can be obtained. Third generation Double Antigen Sandwich ELISA for detection of HIV Ab Substrate Enzyme conjugated HIV Ag E Color Product E E IgG Ab E E E IgM Ab rHIV Ag and synthetic peptides Env/Core Ags Fourth generation Sandwich ELISA for detection of HIV Abs and Ag Substrate Enzyme conjugated HIV Ag E E E E Anti-HIV Ab rHIV Ag/ peptide Color Product Enzyme-conjugated Anti-p24 Ab E E p24 Ag Anti-p24 Ab Fourth-generation combination EIAs HIV Rapid Tests • Qualitative test to detect HIV-1/2 Abs • Simple/Moderate Complexity • Small sample volumes • Serum/Plasma/Whole blood • Visual Reading • Results in 10-15 minutes Lateral flow strip Rapid testing is the method of choice when immediate information is necessary to determine the need for prophylaxis, such as in the labor/delivery, newborn, or post-exposure settings, or when the person who is being tested is unlikely to return for a follow-up visit. HIV Lateral Flow Strips HIV Rapid Test or Lateral Flow Strip for detection of antibodies to HIV-1/2 Control line (Anti-HIV) Test line (HIV Ag) Colloidal Goldconjugated HIV Ag Patient sample Thailand HIV testing algorithm for individual diagnosis • National Guidelines on HIV/AIDS Diagnosis and Treatment: Thailand 2010 • National Guide for HIV Testing. MOPH 2007 HIV testing Algorithms in Adults and Children >18 M A1 A1- (NR) A1+ (R) A2 A1+, A2- A1+, A2+ Repeat A1 and A2 A1-, A2- A1+, A2- A1+, A2+ A3 A1+, A2+, A3Anti-HIV negative Indeterminate Retest at 2 W/3 and 6 m A1+, A2+, A3+ Anti-HIV Positive Retest sample 2 HIV testing Algorithms in Children <18 M Age <12 m Age 12-18 m HIV viral testing at >1 m Ab testing Positive Negative Repeat testing within 2-4 w Repeat testing at age 4 m Positive Negative Positive HIV infection Nonreactive Ab testing at 18 m Negative Repeating testing at age 4-6 m Positive at 2nd and 3rd testing Reactive Reactive Nonreactive Discordant at 2nd and 3rd testing Anti-HIV positive Anti-HIV negative New Technologies and Innovations in HIV Diagnosis • DPP®HIV 1/2 SCREEN Assay – A Rapid Qualitative Screening Assay for the Detection of Antibodies to HIV 1/2 in Oral Fluid, Whole Blood (Venous or Finger-stick), Serum & Plasma – Using colloidal gold protein A conjugate DPP HIV 1/2 Test Procedure Interpretation of Test Results 4th Generation Immunochromatograpic test for detection of HIV Ag/Ab Coming Soon Control bar (anti-HIV) p24 bar (avidin) Ab bar (rHIV Ag + synt peptides) Conjugate pad (Selenium colloid-HIV Ag/ Biotinylated anti-p24+ Selenium colloid anti-p24) B 4th Generation Immunochromatograpic test for detection of HIV Ag/Ab Coming Soon Control bar (anti-HIV) p24 bar (avidin) B Ab bar (rHIV Ag + synt peptides) B Conjugate pad (Selenium colloid-HIV Ag/ Biotinylated anti-p24+ Selenium colloid anti-p24) B Patient sample Determine HIV-1/2 Ag/Ab Combo Coming Soon Control bar p24 Antigen bar Antibody bar Selenium colloid Conjugate pad The 4th generation of one step HIV antigen and antibodies to HIV-1/2 Test Coming Soon Lab on a chip device promises HIV diagnosis in 10 minutes • A new diagnostic device promises confirmation of HIV, TB and other conditions in around 10 minutes. • The ‘lab-on-chip’ device is entirely self-powered, using pressure differences and gravity to separate components of a small blood sample. SIMBAS Chip Schematic http://www.theengineer.co.uk/sectors/medical-and-healthcare/news/lab-onchip-device-promises-hiv-diagnosis-in-10-minutes/1008004.article New HIV Testing Algorithms ? http://www.aphl.org/aphlpro grams/infectious/hiv/Docum ents/StatusReportFINAL.pdf APHL & CDC 2009 • POC Algorithm 1-4 • Laboratory Algorithm 1-5 Laboratory Algorithm 2 Laboratory Algorithm 4 Tests to Stage and Monitor of Patients • CD4 T Cell Counts • Viral Load Assays • Drug Resistance Tests http://www.unitaid.eu/images/market dynamics/publications/unitaid_md_te chnical_report_diagnostics_landscape _web.pdf CD4 T Cell Counts CD4 T Cell Counts • • • • used to assess immune status susceptibility to OIs need for ART and OI prophylaxis for defining AIDS (CD4 <200/mm3) Facts about CD4 • Normal adult CD4 count reference ranges vary by lab; however, ranges are generally within 500 -1500/mm3. • Large individual variability in measurement reflecting method of determining CD4 count by calculation from 3 measured variables: WBC, % lymphocytes, and %CD. http://www.hopkins-aids.edu/management/laboratory_testing/ cd4_cell_count.html?contentInstanceId=8279 CD4 T Cell Counts Facts about CD4 • CD4% less variable than absolute CD4 count; – within-subject CV is 18% for CD4% vs 25% for Abs CD4 count. • Approximate corresponding values for CD4 count and CD4% are: – >500 ~ >29%, 200-500 ~ 14-28%, <200 ~ <14%. • Specimens must be processed within 18 hrs of collection for optimal accuracy CD4 T Cell Counts Factors that Affect CD4 Count • Seasonal and diurnal variation (lowest at 12:30 PM, highest at 8:30 PM), surgery, viral infections, tuberculosis. • Decreases with some medications (e.g. corticosteroids, especially with acute use, less pronounced with chronic use; PEG-IFN, IFN; cancer chemotherapy). • Acute changes in CD4 more often due to redistribution of CD4 in lymphatics, spleen and bone marrow. • Splenectomy causes abrupt, prolonged increase in CD4. In asplenic pts, CD4% provides more accurate assessment of immune status • Sex, race, psychologic stress, & physical stress have minimal effect on CD4. Pregnancy leads to hemodilution & a small decline in CD4 count, but no decline in CD4%. CD4+ T Cell Counting • CD4 Technologies – Flow Cytometry (DPT & SPT) – BD FACSCount (SPT) –Point-of-Care CD4 Technologies Point of Care CD4 Technologies • • • • • • PointCARE LabNow Pima Analyzer Daktari CD4 System Zyomyx CD4 Test CD4 Rapid Test LabNow CD4 Pima Point of Care CD4 • • • • • • • • Absolute CD4 detection Fingerstick or Venous whole blood Low sample volume – 25μL Closed cartridge system No cold-chain requirements Fluorescent detection of CD4+ cells 20min/day internal QC procedure Sample analyses 20 minutes Daktari CD4 HIV Diagnostic Instrument • Microfluidic cell • Electrochemical sensing (lysate impedance measurement) Lab on a chip device for HIV testing • Novel microfluidic HIV test is quick and cheap • Analysis of CD4 and CD8 T-cell numbers, the CD4/CD8 ratio and three secreted cytokines took only seconds. http://www.eurekalert.org/pub_releases/201007/uoc--nmh071610.php Zyomyx CD4 Test Principle: • CD4 reagents bind to CD4 Tcells • selectively transfer them into a secondary liquid medium • concentration of the reagent binded CD4 T-cells in a volumetric compartment • determination of the CD4 Tcell volume by reading the length of a dark visible line • measurement of length as a function of CD4 cell. Zyomyx CD4 Test Zyomyx CD4 Test 2012 STATUS Quick Screen CD4 EQ 200 • Rapid, cost-effective CD4 test • Cutoff of 250+/- 25 CD4 cell equivalents • Uses only 3drops of plasma or serum • Results available in 1520 min OnSight™ – CD4 STATUS Rapid Test • Positive - test line visible which indicates CD4 EQ’s of greater than 200 (+/- 25), or • Negative - no test line visible which indicates CD4 EQ’s of less than 175 (+/- 25) Retro-Status HIV/CD4 350 Rapid Test • • • • • HIV/CD4 Dual test Detects HIV1/2 Abs Cutoff of 350 CD4 cells/millitre Uses few drop of sample Results available in 20 minutes Thank you for your attention