Errors in the diagnostic process • Hierarchy of Qualities in Medicine • Frequency of diagnostic Errors • Judgment under Uncertainty: Heuristics and Biases • The Voytovich Solution Click to View Presentation Hierarchy of Qualties in Medicine From patient‘s point of view Patient Satisfaction Therapeutic Quality Diagnostic Quality Hierarchy of Qualties in Medicine Medical point of view Patient Satisfaction Therapeutic Quality Diagnostic Quality Hierarchy of Qualities in Medicine und cognitive Processes Patient Satisfaction Skills Therapeutic Quality Rules Diagnostic Quality Knowledge Frequency of diagnostic Errors Follow-up Autopsy Study Medizinische Klinik USZ 1972-1982-1992-2002 Lancet 2000;355:2027-31 • Random Selection of 100 patients in each year • Autopsy Rate above 90% until 1992, in the year 2002 Reduction to 53%, complete Autopsy • Classification of diagnostic Errors according to Goldman Classification of diagnostic errors Goldman et al NEJM 1983:380: 1000-05 • Major diagnostic Errors – Class I: Knowledge of correct Diagnosis would have led to Survival – Class II: Knowledge of correct Diagnosis would not have affected Survival (too ill, no Treatment available) • Minor diagnostic Errors – Class III: Missed Diagnosis but not cause of Death – Class IV: Occult, clinically not diagnosable Entity of epidemiological Interest eg Gallstones Major Diagnostic Errors 1972-2002 16 14 % Cases 12 10 1972 1982 1992 2002 8 6 4 2 0 Class I Class II Minor Diagnostic Errors 1972-2002 40 35 % Cases 30 25 1972 1982 1992 2002 20 15 10 5 0 Class III Class IV 16 40 14 35 12 30 10 1972 1982 1992 2002 8 6 % Cases % Cases Class I+II vs. Class III+IV 25 20 15 4 10 2 5 0 0 Class I Class II 1972 1982 1992 2002 Class III Class IV Correct Diagnosis 1972-2002 45 % Cases 40 35 30 1972 1982 1992 2002 25 20 15 10 5 0 Class V Class VI Autopsy Rate and class I Errors over time Kaveh G et al, JAMA 2003: 289:2849-56 Frequency of class I Errors • • • • • • Medizin+ IPS (USZ) 2002 Med-IPS (Mayo-Clinic) 1998-2000 Med-IPS (Paris) 1995-98 Med-IPS (Leuven,Belgien) 1996 32 Spitäler in USA 1984 Medizin (Boston, USA) 1984 40% Klasse I Fehler 2% 4% 10.2% 16% 13% 12% Autopsierate 53% 33% 53% 93% 30% Arch Int Med 2004:164;389; Mayo Clin Proc 2000:75:562; Ann Thorac Surg 1997:64:380; JAMA1987:258:339; Mayo Clin Proc. 2003;78:947-50. NEJM 1988:318;1249 Autopsy: Gold Standard for clinical Diagnosis? D iagnostic errorsderivedfrom C hart review D iagnostic errorsrevealdedby A utopsy ) W ithout A utopsy 2/194(1% W ithA utopsy 3/141(2% ) Pelletier et al J Gen Intern Med 1989:4;300-03 Autopsy: Gold standard for clinical diagnosis? iagnostic D errorsderivedfrom hart review C iagnostic D errorsrevealdedby utopsy A ) utopsy 2/194(1% ithout A W utopsy ithA W ) 3/141(2% ) 19/141(13% Pelletier et al J Gen Intern Med 1989:4;300-03 Judgment under Uncertainty: Heuristics and Biases Tversky and Kahneman Science 1974:185:1124-31 • Representativness – Similarity with „typical“ examples stored in memory • Availability – Recent expierence, painful memory • Adjustment and Anchoring – Stick to early hypotheses despite new information Fehlermechanismen im diagnostischen Prozess Fehler Falsch + Falsch + Falsch + Hypothesen-Bildung Mechanismus Diagnost. Schritt Mechanismus Vorzeitige SchlussFolgerung dito dito Fehler Anamnese + Untersuchung Übersehen Falsch - Auslöser Einbettung Falsch Falsch - dito dito Informationsbeschaffung, Verarbeitung und Überprüfung Fehler Mechanismus Diagnost. Schritt Falsch + Falsch + Falsch + Falsch + Falsch + Annahme zu hoch Vortestwahrscheinlichkeit Spezifität zu tief Test (Labor, Röntgen..) Falsche Formulierung Interpretation eines Tests Vorzeitige Schlussf. Kausales Modell Vorzeitige Schlussf. Überprüfung Mechanismus Fehler Annahme zu tief Falsch Sensitivität zu tief Falsch Falsche Formulierung FalschÜbersehen Falsch Unvollständige Falsch Synthese Cognitive Mechanisms of diagnostic Errors according to A.E. Voytovich* • • • • Omission Premature Closure Inadequate Synthesis Wrong Formulations * J Med Educ 1985:60;302-07 Omission • Most frequent Error • Decreases with Experience Consequences – Delayed or missed Diagnosis Premature Closure • Independent of Experience • Correlates with Confidence (ie Overconfidence) in Relation to the actual Case • Reflects estimated Frequency of the diagnosed Disease Consequences – Delayed or missed Diagnosis – Unnecessary Therapies – False Sense of Confidence if Error is not detected Inadequate Synthesis • Correlates with Experience Consequences – Unnecessary Investigations – Delayed Treatment Cognitive Mechanisms of diagnostic Errors according to A.E. Voytovich* • • • • Omission Premature Closure Inadequate Synthesis Wrong Formulations * J Med Educ 1985:60;302-07 Fehlermechanismen im diagnostischen Prozess Fehler Falsch + Falsch + Falsch + Hypothesen-Bildung Mechanismus Diagnost. Schritt Mechanismus Vorzeitige SchlussFolgerung dito dito Fehler Anamnese + Untersuchung Übersehen Falsch - Auslöser Einbettung Falsch Falsch - dito dito Informationsbeschaffung, Verarbeitung und Überprüfung Fehler Mechanismus Diagnost. Schritt Falsch + Falsch + Falsch + Falsch + Falsch + Annahme zu hoch Vortestwahrscheinlichkeit Spezifität zu tief Test (Labor, Röntgen..) Falsche Formulierung Interpretation eines Tests Vorzeitige Schlussf. Kausales Modell Vorzeitige Schlussf. Überprüfung Lancet 2000:355;2027-31 Mechanismus Fehler Annahme zu tief Falsch Sensitivität zu tief Falsch Falsche Formulierung FalschÜbersehen Falsch Unvollständige Falsch Synthese Major Diagnostic Errors 1972-2002 16 14 % Cases 12 10 1972 1982 1992 2002 8 6 4 2 0 Class I Class II Sensitivity and Specificity • 1-Sensitivity: Rate of missed Diagnoses (false negative rate) • 1-Specificity: Rate of wrong Diagnoses (false positive rate) Cardiovascular Diseases Sensitivity and Specificity p = 0.061 p = 0.034 100 97% 90 86% 82% 85% 82% 80 70 1972 1982 1992 69% 60 50 Sensitivität Spezifität Fehlermechanismen im diagnostischen Prozess Fehler Falsch + Falsch + Falsch + Hypothesen-Bildung Mechanismus Diagnost. Schritt Mechanismus Vorzeitige SchlussFolgerung dito dito Fehler Anamnese + Untersuchung Übersehen Falsch - Auslöser Einbettung Falsch Falsch - dito dito Informationsbeschaffung, Verarbeitung und Überprüfung Fehler Mechanismus Diagnost. Schritt Falsch + Falsch + Falsch + Falsch + Falsch + Annahme zu hoch Vortestwahrscheinlichkeit Spezifität zu tief Test (Labor, Röntgen..) Falsche Formulierung Interpretation eines Tests Vorzeitige Schlussf. Kausales Modell Vorzeitige Schlussf. Überprüfung Lancet 2000:355;2027-31 Mechanismus Fehler Annahme zu tief Falsch Sensitivität zu tief Falsch Falsche Formulierung FalschÜbersehen Falsch Unvollständige Falsch Synthese Infectious Diseases Sensitivity and Specificity p = 0.036 ns 100% 100 100% 99% 86% 80 67% 1972 60 1982 1992 40 25% 20 0 Sensitivität Spezifität Neoplastic Diseases Sensitivity and Specificity ns ns 100 97% 96% 95 90 96% 92% 89% 1972 88% 1982 85 1992 80 75 70 Sensitivität Spezifität Difficulties in learning from Experience • Lack of Search for and use of disconforming Evidence • Lack of outcome Information • Use of unaided Memory for coding, storing and retrieving outcome Information Summary and Proposal • Major diagnostic Errors occur despite an ever increasing repertory of diagnostic Procedures • 85% of serious diagnostic Errors can only be detected by Autopsy • Analysis of error mechanism can be helpful in the Discussion and Prevention of diagnostic Errors • Minimum Autopsy rate of 30% along with a yearly Report on diagnostic Errors should be mandatory for Accreditation of medical Clinics