A presentation on….. FACTS FACTS DEVICES?? BENEFITS OF FACTS MAINTENANCE OF FACTS OPERATION OF FACTS IDENTIFICATION OF FACTS FUTURE ENHANCEMENTS Flexible Alternating Current Transmission System FACTS as they are generally known, are new devices that improve transmission systems. 1. Static VAR Compensators (SVC’s) 2. Thyristor controlled series compensators (TCSCs) 3. STATCOM 4. Unified Power Flow Controller (UPFC) Benefits of utilizing FACTS devices : UPFC CIRCUIT DIAGRAM Better utilization of existing transmission system assets Increased transmission system reliability and availability Increased dynamic and transient grid stability and reduction of loop flows Increased quality of supply for sensitive industries Environmental benefits TECHNICAL BENEFITS OF MAIN FACT DEVICE Voltage Limits Low Voltage at Supply Reactive Shunt capacitor, SVC, TCSC, heavy loads Power Series STATCOM Capacitor High voltage at Remove light load Reactive Power supply Switch EHV SVC, TCSC, Line and\or STATCOM shunt capacitor Absorb Reactive Power Switch Shunt SVC,STATCOM capacitor, Shunt Reactor High voltage Absorb following Reactive outage Power Add shunt SVC,STATCOM reactor Protect Equipment Add arrestor SVC Low Voltage Supply reactive Switch Shunt SVC,STATCOM following power capacitor, Outage reactor, series capacitor Prevent Overload Series Reactor, TCPAR,TCSC PAR Thermal Limits Line or Reduce Transformer Overload Overload Add line or TCSC, UPFC, TCPAR transformer Add series SVC, TCSC reactor Tripping of Limit Circuit Add series UPFC, TCSC Parallel loading reactor, circuit (line) capacitor Loop flows Parallel line Adjust series Add series UPFC, TCSC load sharing reactance capacitor/reac tor Adjust phase Add PAR angle Post-fault sharing TCPAR,UPFC Rearrange PAR, Series TCSC,UPFC,SVC,TCP network or Capacitor/ AR use Reactor “Thermal Limit” actions Flow Direction Adjust Phase PAR TCPAR,UPFC Short Circuit Levels Excessive breaker Limit Short-circuit Add series Reactor, new fault currents currents circuit breaker Change breaker Sub Sync. resonance Potential Turbine Circuit Add new circuit Breaker Rearrange network Split Bus Mitigate Oscillations Series Compensation Investment costs of FACTS devices a) The devices’ equipment costs, and (b) The necessary infrastructure costs 160 160 140 120 140 120 STATCOM 100 80 100 80 SVC 60 60 40 20 40 20 100 200 300 400 500 UPFC T CSC FSC. 100 200 300 400 500 FINANCIAL BENEFITS: 1. Additional sales 2. Additional wheeling charges 3. Avoiding or delaying of investments Maintenance of FACTS devices is minimal and similar to that required for shunt capacitors, reactors and transformers The amount of maintenance ranges from 150 to 250 man-hours per year Operation of FACTS devices operated automatically can be done locally and remotely Steps for the Identification of FACTS Projects: Performance Verification Projects to conduct a detailed network study to investigate the critical conditions of a grid For a stable grid, the optimized utilization of the transmission lines could be investigated an economical study can be performed to compare costs of FACTS devices or conventional solutions with the achievable benefits. Performance Verification The design of all FACTS devices should be tested in a transient network analyzer (TNA) The results of the TNA tests should be consistent with the results of the network study Bibliography: . Electrical power systems by C.L.Wadhawa, new age publishers www.abb.com www.siemens.com