Huawei solutions for SAP HANA - Competition analysis Content 1 Huawei solutions for SAP HANA summary 2 Single node competition analysis 3 Huawei VS. IBM converged solution 4 Huawei VS. traditional solution 1 Complete offerings support various deployment options In the Cloud In the DataCenter SAP HANA One RH2288H + FusionSphere certified SAP HANA Enterprise Cloud Coming Single Host RH5885H V3 for Enterprise(XS/S/M/L/L+) RH2288H for SME- B1H,B1A Scale-out / HA cluster 2 FusionCube with distributed storage or SAN storage What Does Huawei Provide? 1. What we sell is highlighted in Orange, System maintenance including hardware, software, installation, Enterprise application Integration development and maintenance. 2. Database Software includes the SUSE OS Huawei/ Partner (including three-year warranty) 3. Installation Installation services: hardware, OS, and OS database installation Optional: Provide by Huawei or Partner 4. Installation is performed on site. 5. Huawei provides one-stop maintenance for all hardware . 3 Hardware maintenance Hardware Fastest Growing products in the server Market No.1 Transaction Processing Performance Council TPC spec Best Performance 105 VMmark world records in performance benchmark tests Source: Gartner 2013 analysis report 4 2013 Shipment growth rate in global markets No.2 2013 server shipments in China's market No.4 2013 server shipments in global market Optimized for performance • Pre-optimized and one-stop support • 100-100,000 times faster than a SingleNode:RH5885H V3 Scale Out:FusionCube traditional database High Reliability & Outstanding Performance: • Powered by RH5885H V3 with 53 reliability and service ability features • #1 in SPECint and SPECfp • Fastest write performance with 15% less latency and 20% more bandwidth • Most complete SAP HANA offering • Best scalability 5 Content 1 Huawei solutions for SAP HANA summary 2 Single node competition analysis 3 Huawei VS. IBM converged solution 4 Huawei VS. traditional solution 6 Huawei Solutions for SAP HANA– Single Node (IvyBridge) Business suite on HANA(SoH/OLTP) RH5885H V3 128GB(XS)->256GB(S)>512GB(M)->1TB(L)->2TB(L+) Business warehouse on HANA(BWoH/OLAP) … … ES3000 SSD Log volume Best Performance/Price ratio Best density, no additional JBOD needed HDD Smoothly Scale up Data volume Fastest PCIe SSD card in the world : Huawei ES3000, optimized for SAP HANA Low Cost configuration and High Performance configuration. Certification:http://scn.sap.com/docs/DOC-52522 10 Huawei Solutions for SAP HANA– Single Node configuration Basic configuration Server Model CPU Memory Log Volume Data Volume OS Upgrade Options XS S M L L+ RH5885H V3 RH5885H V3 RH5885H V3 RH5885H V3 RH5885H V3 2* IVB-EX E7-4880/4890 V2 2* IVB-EX E7-4880/4890 V2 2* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 128GB DDR3 256GB DDR3 512GB DDR3 1024GB DDR3 2048GB DDR3 1T from 8*900GB 10k 2.5" SAS 1T from 8*900GB 10k 2.5" SAS 1T from 8*900GB 10k 2.5" SAS 1T from 8*900GB 10k 2.5" SAS 2* 800GB ES3000 HDD , RAID 5 HDD , RAID 5 HDD , RAID 5 HDD , RAID 5 3T from 8*900GB 10k 2.5" SAS 3T from 8*900GB 10k 2.5" SAS 3T from 8*900GB 10k 2.5" SAS 3T from 8*900GB 10k 2.5" SAS 14*900GB 10k 2.5" SAS HDD , HDD , RAID 5 HDD , RAID 5 HDD , RAID 5 HDD , RAID 5 RAID 50 SLES 11.3 for SAP HANA 128G->256G>512G->1T->2T(easily upgrade by adding more components) High performance configuration Server Model CPU Memory Log Volume Data Volume OS Upgrade Options XS S M L L+ RH5885H V3 RH5885H V3 RH5885H V3 RH5885H V3 RH5885H V3 2* IVB-EX E7-4880/4890 V2 2* IVB-EX E7-4880/4890 V2 2* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 128GB DDR3 256GB DDR3 512GB DDR3 1024GB DDR3 2048GB DDR3 2* 800GB ES3000 2* 800GB ES3000 2* 800GB ES3000 2* 800GB ES3000 2* 800GB ES3000 8*900GB 10k 2.5" SAS HDD , 8*900GB 10k 2.5" SAS HDD , 8*900GB 10k 2.5" SAS HDD , 8*900GB 10k 2.5" SAS HDD , 14*900GB 10k 2.5" SAS HDD , RAID 5 RAID 5 RAID 5 RAID 5 RAID 50 SLES 11.3 for SAP HANA 128G->256G>512G->1T->2T(easily upgrade by adding more components) 11 RH5885H V3 server performance No.1 in the SPECint and SPECfp tests Improve 64% for TPC-E 6000 5000 Segment Benchmark Partner/Platform Absolute Result Relative Improvemen t 4000 Importance 3000 Technical computing SPECfp_rate_ba se2006 4 processor Huawei RH5885H V3 using Intel Xeon processor E7-4890 v2 (37.5M cache.2.8GHz) 1730 baseline result 2.3x performance over Intel xeon processor E7-4870 World Record 4-socket result Enterprise computing SPECint_rate_ba se2006 4 processor Huawei RH5885H V3 using Intel Xeon processor E7-4890 v2 (37.5M cache.2.8GHz) 2320 baseline score 2.1x performance over Intel xeon processor E7-4870 World Record 4-socket result (Tie) Source: Intel Official Website http://www.intel.com/content/www/us/en/benchmarks/server/xeon-e7-summary.html 12 2000 1000 0 RH5885H V3 (3TB) X3850 (2TB) RH5885 V2 (1TB) IBM X3850 (1TB) RX500 S7 (1TB) DL580 G7 (1TB) Better Performance of PCIe SSD Card FUSION-IO STEC ioDrive2 Duo Kronos™ Turbo PCIe SSA Z-Drive R4 CM84/RM84 Z-Drive R4 CM88/RM88 ES3000 Model OCZ Huawei Flash granule SLC MLC MLC MLC MLC MLC Capacity 1.2 TB 2.4 TB 1.95 TB 300 GB, 600 GB, 1.2 TB 800 GB, 1.6 TB, 3.2 TB 800 GB, 1.2 TB, 2.4 TB Dimensions FH-HL FH-HL FH-HL HH-HL FH-3/4L FH-HL Bus interface Gen 2 x8 Gen 2 x8 Gen 2 x8 Gen 2 x8 Gen 2 x8 Gen 2 x8 Read bandwidth 3.0 GB/s 3.0 GB/s 2 GB/s 2 GB/s 2.8 GB/s 3.2 GB/s Read IOPS 950k (512 B) 892k (512 B) 220k (4 KB) - - 760K (4 KB) Read latency 47 µs 68 µs - - - 49 µs Write bandwidth 2.5 GB/s 2.5 GB/s 2 GB/s 2 GB/s 2.8 GB/s 2.8 GB/s Write IOPS 935k (512 B) 935k (512 B) 200k (4 KB) 250k (4 KB) 160k (8 KB) 410k (4 KB) 275k (8 KB) 240K (4 KB) Write latency 15 µs 15 µs < 50 µs - - 8 µs 13 Huawei Solution Advantage – Single Node(IvyBridge) Item Huawei IBM HP Hitachi Cisco Dell Fujitsu NEC 128G~2T √ √ √ x x √ √ x External JBOD NO yes yes x x NO yes x JBOD Power Consumption NO 100 watts 100 watts x x NO 100 watts x Log Volume ES3000 800G SSD HDD with cache cade SSD disk(2*800G) x x NVME SSD HDD(10*900G) disk(2*400G) x Log IOPS_w(4k) 120K 90K 36k x x 36k 280 x Log IOPS_r(4K) 570K 200K 75K x x 75K 400 x Log Latency_w 8μs 65μs 65μs x x 65μs 70ms x Log Latency_r 49μs 50μs 50μs x x 50μs 70ms x Density(2T) 4U 6U 6U x x 4U 12U x ES3000 KPI: http://enterprise.huawei.com/en/products/itapp/server/high-performance-pcIe-card/hw-194918.htm SSD DISK and HDD: general KPI data 14 Huawei Solution Advantage VS. HP DL580 G8 Server Model CPU Memory Log Volume Data Volume XS RH5885H V3 2* IVB-EX E7-4880/4890 V2 128GB DDR3 1T from 8*900GB 10k 2.5" SAS HDD , RAID 5 3T from 8*900GB 10k 2.5" SAS HDD , RAID 5 OS Upgrade Options S RH5885H V3 2* IVB-EX E7-4880/4890 V2 256GB DDR3 1T from 8*900GB 10k 2.5" SAS HDD , RAID 5 3T from 8*900GB 10k 2.5" SAS HDD , RAID 5 M L L+ RH5885H V3 RH5885H V3 RH5885H V3 2* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 512GB DDR3 1024GB DDR3 2048GB DDR3 1T from 8*900GB 10k 2.5" 2* 800GB PCIe SSD ES3000 2* 800GB PCIe SSD ES3000 SAS HDD , RAID 5 3T from 8*900GB 10k 2.5" 8*900GB 10k 2.5" SAS HDD , 14*900GB 10k 2.5" SAS HDD SAS HDD , RAID 5 RAID 5 , RAID 50 SLES 11.3 for SAP HANA 128G->256G>512G->1T->2T(easily upgrade by adding more components) VS XS S DL580 G8 2* IVB-EX E7-4880/4890 V2 256GB DDR3 0.5T from 8x600GB 10k 2.5" SAS HDD , RAID 5 1.5T from 8x600GB 10k 2.5" SAS HDD , RAID 5 Server Model CPU Memory Log Volume Data Volume OS Upgrade Options 15 M L L+ DL580 G8 DL580 G8 DL580 G8 2* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 512GB DDR3 1024GB DDR3 2048GB DDR3 0.5T from 8x600GB 10k 2.5" 2*800GB SSD disk 2*800GB SSD disk SAS HDD , RAID 5 1.5T from 8x600GB 10k 2.5" 8x600GB 10k 2.5" SAS HDD , 25x600GB 10k 2.5" SAS HDD SAS HDD , RAID 5 RAID 5 , RAID 50 SLES 11.3 for SAP HANA 256G>512G->1T->2T Huawei Solution Advantage VS. HP DL580 G8 Huawei HP Higher Density 4U 6U(Additional JBOD) Upgrade smoothly No any change of chassis Additional JBOD for 2T size(change of power, rack size, cables, etc.) Better Log volume performance Huawei PCIe SSD card, Fastest PCIe SSD card in the General SSD disk world Lower power No Additional JBOD more than 100W for one JBOD(JBOD’s fans, power, controller, etc.) RH5885H V3 DL580 G8 VS. + JBOD 16 Huawei Solution Advantage –VS. Fujitsu PQ2400 Server Model CPU Memory Log Volume Data Volume XS RH5885H V3 2* IVB-EX E7-4880/4890 V2 128GB DDR3 1T from 8*900GB 10k 2.5" SAS HDD , RAID 5 3T from 8*900GB 10k 2.5" SAS HDD , RAID 5 OS Upgrade Options S RH5885H V3 2* IVB-EX E7-4880/4890 V2 256GB DDR3 1T from 8*900GB 10k 2.5" SAS HDD , RAID 5 3T from 8*900GB 10k 2.5" SAS HDD , RAID 5 M L L+ RH5885H V3 RH5885H V3 RH5885H V3 2* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 512GB DDR3 1024GB DDR3 2048GB DDR3 1T from 8*900GB 10k 2.5" 2* 800GB PCIe SSD ES3000 2* 800GB PCIe SSD ES3000 SAS HDD , RAID 5 3T from 8*900GB 10k 2.5" 8*900GB 10k 2.5" SAS HDD , 14*900GB 10k 2.5" SAS HDD SAS HDD , RAID 5 RAID 5 , RAID 50 SLES 11.3 for SAP HANA 128G->256G>512G->1T->2T(easily upgrade by adding more components) VS Server Model CPU Memory Log Volume Data Volume OS Upgrade Options XS S M L L+ PQ 2400 E/S/L PQ 2400 E/S/L PQ 2400 E/S/L PQ 2400 E/S/L PQ 2400 E/S/L 2* IVB-EX E7-4880/4890 V2 2* IVB-EX E7-4880/4890 V2 2* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 128GB DDR3 256GB DDR3 512GB DDR3 1024GB DDR3 2048GB DDR3 0.5T from 10*900GB 10k 2.5" 0.5T from 10*900GB 10k 2.5" 0.5T from 10*900GB 10k 2.5" 0.5T from 10*900GB 10k 2.5" 0.5T from 15*900GB 10k 2.5" SAS HDD , RAID 50 SAS HDD , RAID 50 SAS HDD , RAID 50 SAS HDD , RAID 50 SAS HDD , RAID 50 384G from 10*900GB 10k 2.5" 786G from 10*900GB 10k 2.5" 1.5T from 10*900GB 10k 2.5" 3T from 10*900GB 10k 2.5" 6T from 15*900GB 10k 2.5" SAS HDD , RAID 50 SAS HDD , RAID 50 SAS HDD , RAID 50 SAS HDD , RAID 50 SAS HDD , RAID 50 SLES 11.3 for SAP HANA 128G->256G>512G->1T->2T 17 Huawei Solution Advantage –VS. Fujitsu PQ2400 Higher Density Lower power Huawei Fujitsu 4U 12U(Additional JBOD) No Additional JBOD more than 100W for one JBOD(JBOD’s fans, power, controller, etc.) 4U chassis 10U chassis with more fans, power, etc. Huawei PCIe SSD card, Fastest PCIe SSD card in the world General HDD Stander 4 socket architecture 25%~30% performance drop of CPU by using 4CPU in 8 socket architecture Better performance RH5885H V3 PQ2400 JBOD + VS. CPU 1 CPU 4 CPU 2 CPU 3 Lack two QPI lines if use as 4 socket in 8 socket architecture 25~30% CPU performance 4 socket 18 CPU 1 CPU 4 CPU 5 CPU 8 CPU 2 CPU 3 CPU 6 CPU 7 8 socket Huawei Solution Advantage –VS. IBM 3850 X6 Server Model CPU Memory Log Volume Data Volume XS RH5885H V3 2* IVB-EX E7-4880/4890 V2 128GB DDR3 1T from 8*900GB 10k 2.5" SAS HDD , RAID 5 3T from 8*900GB 10k 2.5" SAS HDD , RAID 5 OS Upgrade Options S RH5885H V3 2* IVB-EX E7-4880/4890 V2 256GB DDR3 1T from 8*900GB 10k 2.5" SAS HDD , RAID 5 3T from 8*900GB 10k 2.5" SAS HDD , RAID 5 M L L+ RH5885H V3 RH5885H V3 RH5885H V3 2* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 4* IVB-EX E7-4880/4890 V2 512GB DDR3 1024GB DDR3 2048GB DDR3 1T from 8*900GB 10k 2.5" 2* 800GB PCIe SSD ES3000 2* 800GB PCIe SSD ES3000 SAS HDD , RAID 5 3T from 8*900GB 10k 2.5" 8*900GB 10k 2.5" SAS HDD , 14*900GB 10k 2.5" SAS HDD SAS HDD , RAID 5 RAID 5 , RAID 50 SLES 11.3 for SAP HANA 128G->256G>512G->1T->2T(easily upgrade by adding more resources) VS Server Model CPU Memory Log Volume Data Volume OS Upgrade Options XS S M 3850 X6 3850 X6 3850 X6 2* IVB-EX E7-4880/4890 V2 2* IVB-EX E7-4880/4890 V2 2* IVB-EX E7-4880/4890 V2 128GB DDR3 256GB DDR3 512GB DDR3 1T from 4x1.2TB 10k 2.5" 1T from 4x1.2TB 10k 2.5" 1T from 4x1.2TB 10k 2.5" SAS HDD , Flash cache RAID SAS HDD , Flash cache RAID SAS HDD , Flash cache RAID 5 5 5 1.6T from 4x1.2TB 10k 2.5" 1.6T from 4x1.2TB 10k 2.5" 1.6T from 4x1.2TB 10k 2.5" SAS HDD , Flash cache RAID SAS HDD , Flash cache RAID SAS HDD , Flash cache RAID 5 5 5 SLES 11.3 for SAP HANA 128G->256G>512G->1T->2T 19 L 3850 X6 4* IVB-EX E7-4880/4890 V2 1024GB DDR3 1T from 13x1.2TB 10k 2.5" SAS HDD , Flash cache RAID 5 13.2T from 13x1.2TB 10k 2.5" SAS HDD , Flash cache RAID 5 L+ 3850 X6 4* IVB-EX E7-4880/4890 V2 2048GB DDR3 1T from 13x1.2TB 10k 2.5" SAS HDD , Flash cache RAID 5 13.2T from 13x1.2TB 10k 2.5" SAS HDD , Flash cache RAID 5 Huawei Solution Advantage –VS. IBM 3850 X6 Huawei IBM Higher Density 4U Upgrade smoothly No any change of chassis 4U+2U Additional JBOD for 1T size(change of power, rack size, cables, etc.) No Additional JBOD more than 100W for one JBOD(JBOD’s fans, power, controller, etc.) Huawei PCIe SSD, special optimized for HANA log volume IBM eXFlash as cache for log volume Memory bandwidth: Occupy memory channel, lost 20%~25% Memory bandwidth: PCIe SSD, no occupying of memory channel memory bandwidth Read mechanism: Additional resource use of CPU by polling Read mechanism: PCI interrupt with out else using of CPU technology Lower power Better performance Read latency: One copy from SSD controller RH5885H V3 3850 X6 JBOD + VS. APP ⑤ ① Read latency: Two copy from SSD controller and Rush chip with more latency. APP ① Driver ⑧ Driver ④ ② DDR CPU ② ③ System memory CPU PCIE System memory ③ eXFLASH DDR ④ RUSH ⑤ ⑦ DDR ⑥ SSD controller PCIE SSD SSD controller FLASH CPU internal DMA Huawei PCIe SSD Write buffer Internal buffer IBM eXFLASH 20 DDR FLASH Huawei Solution Advantage –VS. IBM 3850 X6 Huawei IBM Higher Density 4U 4U+2U Upgrade smoothly No any change of chassis Additional JBOD for 1T size(change of power, rack size, cables, etc.) Lower power No Additional JBOD more than 100W for one JBOD(JBOD’s fans, power, controller, etc.) Better performance Huawei PCIe SSD card, Fastest PCIe SSD card in the world General HDD with Cache Cade(general SSD) RH5885H V3 3850 X6 VS. + JBOD 21 Huawei Solutions for SAP HANA –RH8100H V3(Ivybridge) Business suite on HANA(SoH/OLTP) RH8100H V3 128GB(XS)->256GB(S)>512GB(M)->1TB(L)->2TB(XL)->4TB(XXL)->6TB(XXXL) Business warehouse on HANA(BWoH/OLAP) High performance and Scalable …… ES3000 SSD log volume Best density, no additional JBOD Upgrade smoothly HDD Huawei PCIe SSD card, Fastest PCIe SSD card in the world, optimized Data volume for SAP HANA 22 Content 1 Huawei solutions for SAP HANA summary 2 Single node competition analysis 3 Huawei VS. IBM converged solution 4 Huawei VS. traditional solution 23 IBM SAP HANA solution Using Rack server: X5 or X6 system; Using GPFS with local disk to create a shared file system; HANA computing node and storage disks in a same server; 2T size rack view 24 Huawei FusionCube HANA Solution:separated architecture Management Nodes Inner interconnect network In-memory computing cluster 。。。 Storage Cluster Worker Worker 。 。。 Standby Log Persistent Storage Layer (SSD/HDD) 。。。 Data Persistent Storage Layer (HDD) VS. Huawei Separated architecture IBM Integrated architecture • Independent operation and maintenance 25 Huawei VS. IBM Level1 Performance Density Flexibility Level2 IBM Huawei description IO E2E latency (Log 4K ) ~500us <200us The latency is key factor for SAP HANA performance. Persistence efficiency (Data 16k) Overwrite:~700MB/S(using FusionIO) Overwrite:>1400MB/S Data load (Data 16K) Read:~1250MB/S(using FusionIO) Read:1430MB/S One rack 6 nodes 12 nodes External switch yes No, less 16 nodes If need more storage, need to purchase more IBM X5 or X6 system and more GPFS license, need add GPFS nodes Using separate storage nodes, can extend the storage disk as customer needed. Storage capacity *IBM’s W/R data is analysis according to “《IBM-GPFS-and-Fusion-IO-for-IOP-Performance》” 26 Huawei’s ES3000 PCIe SSD card is the fastest PCIe SSD in the world. --StorageReview test result. http://www.storagereview.co m/sysbench_oltp_benchmar k IBM:4U rack server,6 nodes per rack is classic configuration for IBM Huawei:1.5U blades,can support 12 nodes per rack. IBM HA – Manual operation needed 4. (on any active node) Transfer server license Applies to GPFS 3.5.0-7 and later. Step 5 requires a node with a valid server license in the cluster. With GPFS 3.5.0-7 a new "FPO license" was introduced which is incompatible to the server roles "quorum node" and "configuration server". If you want to put these roles on a active server with a FPO license, you need to move the "server license" to this node. Check the licenses with the command 1 # mmlslicense –L Source : operationsguide - IBM solutions for SAP hana , 108 pages 30 Content 1 Huawei solutions for SAP HANA summary 2 Single node competition analysis 3 Huawei VS. IBM converged solution 4 Huawei VS. traditional solution 31 Huawei VS. Traditional solution Huawei HP IvyBridge √ √ 1T size √ √ √ Blade server √ √ √ Rack server Density per rack Energy Cost(16T) Log volume(SSD) Hitachi Cisco 512G: Blades, 8 nodes/Rack; 1T: Rack server 4 nodes/Rack 27KW 30KW Blades ,8 nodes/rack Fujitsu NEC √ √ √ Blades,12 nodes per rack Dell √ √ √ Blades ,8 nodes/rack 4U rack server; 4 nodes/rack 4U rack server, 4 nodes/ rack 7U rack server 62KW 56KW Yes Yes √ √ external switch No Yes Yes One stop support services √ √ √ 33 Yes Yes √ √ Huawei FusionCube for SAP HANA Management Nodes Internal switch In-memory computing cluster 。。。 Storage Cluster Worker Worker Standby 。。。 Log Persistent Storage Layer (HDD/SSD ) 。。。 Data Persistent Storage Layer (HDD) 1)Need not SAN storage, eliminate SAN storage bottlenecks 2)Need not centralized NFS controller 3)Support Shared Nothing Distributed Storage 4)Single set of distributed storage, simplified management . (there are several sets of storage in other traditional storage vendor’s solution ) 34 The simplest deployment, the highest density 2 Terabyte/rack Traditional : Complex integration Other Vendor 11 Terabyte/rack Front View FusionCube Rear View 35 FusionCube Simplified Management Unified monitoring and alert HANA DB HANA DB Centralized management of hardware: servers, storages, IP and InfiniBand switches Centralized alerting and real-time monitoring One-stop hardware support services Traditional Infrastructure Separate Management Platform Unified monitoring and alert Server Converged infrastructure (server\network\storage) Administrator Network Administrator 36 Storage Administrator Unified Management FusionStorage— Best Scalability and Higher Performance Server2 Server1 ServerN ... HANA DB Table Table Table Table Table Table Table Table Table • High Performance Storage Controller VBS OSD SSD ... OSD HDD SSD 37 VBS HDD • High Reliability Storage ServerN Storage Server2 Storage Server1 Disk Layer ... VBS OSD SSD HDD • High Scalability Closing the huge latency gap between different storage media Huawei ES3000 PCIe SSD card is the fastest PCIe SSD card in the world! Bottleneck 6ms DB write performance 750X 40X Delta data flush to disk time? 8μs Recovery time? 200ns Memory PCIe SSD Disk 38 Data load time? Better Performance of SSD Card FUSION-IO STEC ioDrive2 Duo Kronos™ Turbo PCIe SSA Z-Drive R4 CM84/RM84 Z-Drive R4 CM88/RM88 ES3000 Model OCZ Huawei Flash granule SLC MLC MLC MLC MLC MLC Capacity 1.2 TB 2.4 TB 1.95 TB 300 GB, 600 GB, 1.2 TB 800 GB, 1.6 TB, 3.2 TB 800 GB, 1.2 TB, 2.4 TB Dimensions FH-HL FH-HL FH-HL HH-HL FH-3/4L FH-HL Bus interface Gen 2 x8 Gen 2 x8 Gen 2 x8 Gen 2 x8 Gen 2 x8 Gen 2 x8 Read bandwidth 3.0 GB/s 3.0 GB/s 2 GB/s 2 GB/s 2.8 GB/s 3.2 GB/s Read IOPS 950k (512 B) 892k (512 B) 220k (4 KB) - - 760K (4 KB) Read latency 47 µs 68 µs - - - 49 µs Write bandwidth 2.5 GB/s 2.5 GB/s 2 GB/s 2 GB/s 2.8 GB/s 2.8 GB/s Write IOPS 935k (512 B) 935k (512 B) 200k (4 KB) 250k (4 KB) 160k (8 KB) 410k (4 KB) 275k (8 KB) 240K (4 KB) Write latency 15 µs 15 µs < 50 µs - - 8 µs 39 Huawei VS. Cisco Factor 3.5T 11T, 3x High performance Item CISCO Huawei Comment(Huawei/CISCO) Latency of Log Volume 6GB FC+ SSD (15us) 56GB infiniband + NVDIMM(200ns) Huawei has the lowest latency Throughput of Data Volume 6GB FC+ Only two controller 56GB infiniband + FusionStorage distributed controller(more than 3) Huawei has the biggest bandwidth The latest CPU, 2~3 X performance than westmere cpu CPU Westmere CPU Ivybridge CPU(new generation cpu) Speed of Data load 6GB FC+ Only two controller 56GB infiniband + FusionStorage distributed controller(more than 3) Huawei has 3-6x throughput of data load SAS(120M) SSD(read : 3.2GB/s) The faster persistency layer Rebalance time:< 12h/T Rebalance time:<0.5h/T 24x data recovery speed No SPOF, 2 rack switch No SPOF, 4 switch modules more redundant Data storage: Raid 5 Data storage: Raid10-like Density of single rack 3.5T RAM* (NetAPP) (8*512G HANA nodes) 11T RAM(12*1T HANA nodes) Huawei has 3x density Density of 16 nodes 2 racks 2 racks 1x 7.5T RAM 15T RAM 2x Power consumption 26KW/16*512G nodes 27KW/16*1T nodes About 2x of power density Deployment difficulty complex cable connections among multi devices, need outer switch simple cable connection between chassis, no need outer switch The simpler deployment Unified management Different management Unified management of computing/storage/network Cloud support yes yes Storage selfrecovering High reliability HA Low TCO 40 Same Huawei VS. HP Factor 3T 11T,3.3x High performance Item HP Huawei Comment(Huawei/HP) Latency of Log Volume 6GB FC+ SSD (56us) 56GB infiniband + NVDIMM(200ns) Huawei has the lowest latency Throughput of Data Volume 6GB FC 56GB infiniband + FusionStorage distributed controller(more than 3) Huawei has the biggest bandwidth CPU Ivybridge CPU Ivybridge CPU The latest CPU Speed of Data load SAS(120M) 6GB FC 56GB infiniband + FusionStorage distributed controller(more than 3) Huawei has 3-6x throughput of data load SAS(120M) SSD(read : 3.2GB/s) The faster persistency layer Rebalance time:< 12h/T Rebalance time:<0.5h/T 24x data recover speed No SPOF, 2 rack switch No SPOF, 4 switch modules More redundant Data storage: Raid 5 Data storage: Raid10-like Better reliability Density of single rack 3T RAM* (4*1T HANA nodes, 3*Worker+1*Standby) 11T RAM(12*1T HANA nodes, 11*Worker+1*Standby) Huawei has 3.3x density Density of 16 nodes 4 racks 2 racks 2x 15T RAM 15T RAM 1x Power consumption 30KW/16*1T nodes 27KW/16*1T nodes About 1.1x of power density Deployment difficulty complex cable connections among multi devices, need outer switch simple cable connection between chassis, no need outer switch The simpler deployment Unified management Different management Unified management of computing/storage/network Cloud support yes yes Storage selfrecovering High reliability HA Low TCO 41 Same Huawei VS. Dell Factor 2T 11T,5.5x High performance Item Dell Latency of Log Volume 6GB FC+ SSD (15us) 56GB infiniband + NVDIMM(200ns) Huawei has the lowest latency Throughput of Data Volume 6GB FC+ Only two controller 56GB infiniband + FusionStorage distributed controller(more than 3) Huawei has the biggest bandwidth CPU Westmere CPU Ivybridge CPU(new generation cpu) The latest CPU, 2~3 X performance than westmere cpu Speed of Data load 6GB FC+ Only two controller 56GB infiniband + FusionStorage distributed controller(more than 3) Huawei has 3-6x throughput of data load SAS(120M) SSD(read : 3.2GB/s) The faster persistency layer Rebalance time:< 12h/T Rebalance time:<0.5h/T 24x data recover speed No SPOF, 2 rack switch No SPOF, 4 switch modules More redundant Data storage: Raid 5 Data storage: Raid10-like 2T RAM* (5*512G HANA nodes) 11T RAM(12 *1T HANA nodes) Huawei has 5.5x density 4 racks 2 racks 2x 7.5T RAM 15T RAM 2x Power consumption 28KW/16*512G nodes 27KW/16*1T nodes 2x ofpower density Deployment difficulty complex cable connections among multi devices, need outer switch simple cable connection between chassis, no need outer switch The simpler deployment Unified management Different management Unified management of computing/storage/network Cloud support yes yes Storage selfrecovering High reliability Huawei Comment(Huawei/Dell) HA Density of single rack Density of 16 nodes Low TCO 42 Same HUAWEI ENTERPRISE ICT SOLUTIONS A BETTER WAY Copyright©2012 Huawei Technologies Co., Ltd. All Rights Reserved. The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice. Q&A-1 1. How to upgrade from 1T to 2T, 4T or 6T smoothly? The time window to upgrade is very short, so smoothly is not the most important thing. The release of Intel CPU’s frequency is once a year. (see Q&A-4) SAP HANA can not make two different generations of CPU running on the same system Customer just have one year window to upgrade hardware which also faces old and new CPU architecture choices.(Performance have 50%~100% improved from new version to old version) (see Q&A-5) There are no vendor have the perfect program of smoothly upgrade. 1. Same computing/storage/fans/power models with different chassis. (IBM x6) 2. Same computing/storage/fans/power models with same chassis (Fujitsu, Huawei RH8100) 3. High initial cost.(see Q&A-2) Replace chassis.(see Q&A-2) New CPU platform to choose.(see Q&A-5) High initial cost (higher than program 1) .(see Q&A-2) Lower CPU performance(30% lower).( see Q&A-3) New CPU platform to choose.(see Q&A-5) Different architecture for 4-socket and 8-socket (HP, Huawei RH5885H V3) Incompatible with 4 socket and 8 socket. Best initial cost 44 Q&A-2 1. How to upgrade of IBM or Fujitsu? 4T~6T 128G~2T upgrade IBM: 3950 X6 3850 X6 High initial cost (CPU(8-way), chassis, blade, etc) 128G~2T Replace Chassis, Add new models (CPU, memory, etc) New CPU platform to choose(E7 V3 will release at Q4 2014 or Q1 2015) there is no guarantee subsequent upgrades Maintenance 4T~6T upgrade Fujitsu 2800E: High initail cost (4*CPU(8-way), chassis, blade, etc) Lower performance(4*CPU(8-way), lose two QPI lines,30% drop) 45 New CPU platform to choose(E7 V3 will release at Q4 2014 or Q1 2015) Q&A-3 1. Why performance will be lower from using 4 CPU in 8socket architecture CPU1 CPU4 CPU1 CPU4 CPU5 CPU8 CPU2 CPU3 CPU2 CPU3 CPU6 CPU7 Lack two QPI lines if use as 4 socket in 8 socket architecture 4 socket 8 socket 25~30% CPU performance 46 Q&A-4 1. What is the roadmap of Intel? SAP HANA can not make two different generations of CPU running on the same system 2010 2011 2012 Intel® Microarchitecture Codename Nehalem 2013 Intel® Microarchitecture Codename Sandy Bridge Tylersburg 2014 2015 Intel® Microarchitecture Codename Haswell Romley 2016+ Intel® Microarchitecture Codename skylake Grantly Purely Nehalem Westmere Sandy Bridge Ivy Bridge Haswell Broad well Skylake 45nm 32nm 32nm 22nm 22nm 14nm 14nm New Microarchitecture TOCK New Process Technology TICK New Microarchitecture TOCK 47 New Process Technology TICK New Microarchitecture TOCK New Process Technology TICK New Microarchitecture TOCK Future 11nm New Process Technology TICK Q&A-5 1. Why new version CPU is popular? There are 50%~100% performance improvement from new version to old version. So do you want to buy the old one when new version is released? http://www.intel.com/content/www/us/en/benchmarks/server/xeon-e7-summary.html 48