`YGFC` FAN COIL UNITS NEW PRODUCTS

advertisement
‘YGFC’ FAN COIL UNITS
NEW PRODUCTS - 2006
YGFC FAN COIL UNIT
• FACTORY LOCATED IN GUANGZHOU, CHINA
– CAPACITY = 300,000 UNITS/YEAR = 1,000 UNIT/DAY!
• CERTIFICATION
– ISO 9001:2000, GB/T 19002:2000 CERTIFIED FACTORY
– GB/T 19232:2003 CERTIFIED TEST LAB (ONLY 2 IN
CHINA)
FEATURES
YGFC FAN COIL UNIT
– CE (TUV) CERTIFIED
– CONFIGURATION: CONCEALED, CABINET, HORIZONTAL,
VERTICAL
– COIL: 2 CHOICES, CONVENTIONAL OR DISTRICT COOLING
– 10 SIZES (70-600 L/S, 1-15KW COOLING)
– DRAIN PAN: DIE-FORMED, ANTI-RUST PAINTED, INSULATED
– MOTORS: DIRECT DRIVE, THERMAL PROTECTION, BALL
BEARING
• TESTING
– COIL PRESSURE TESTED AT 2400 KPA
– MOTOR TESTED FOR EARTH LEAK AND CURRENT
YGFC FAN COIL UNIT
• SPECIFICATION
– 3 OR 4 ROW COIL, WORKING PRESSURE 1600kPa
– FILTER: 6mm NYLON
– 1mm GALV.STEEL CASING FOR ADDED NOISE
REDUCTION
– INSULATED PAINTED DRAIN PAN
– 10mm COATED FIBREGLASS INSULATED FAN DECK &
COIL SECTION
YGFC FAN COIL UNIT
• OPTIONS
– CASING: FULLY POWDER COATED
– FILTER: 25 MM ALUMINUM
– FINS: HYDROPHILIC, EPOXY COAT, COPPER
– STAINLESS STEEL DRAIN PAN
– MOTORS: IP 23 AS STANDARD, 42 & 54 AS OPTION
– 6mm CLOSED CELL INSULATED RETURN PLENUM,
ELECTRIC HEATER
YGFC FAN COIL UNIT
• ADVANTAGES
– CHOOSE FROM 10 MODEL SIZES TO MATCH ROOM
NEED
– LOW HEIGHT (250MM) SUITABLE FOR TOWER
BLOCKS
– WHISPER-QUIET OPERATION
– RESISTANCE TO CORROSION
– ADAPTABILITY TO STANDARD OR DISTRICT
COOLING APPLICATION
YGFC FAN COIL UNIT
• ADVANTAGES
– EASE OF MAINTENANCE
– LOW RISK OF LEAKS FROM DRAIN PAN AND COIL
CONNECTIONS
– LOW RISK OF BEARING WEAR
– LONGER MOTOR LIFE – LONGER UNIT LIFE!
– ECONOMICAL LIFE CYCLE
DISTRICT COOLING
• Definition
– Produce chilled water at a central plant
– Distribute to buildings for AC needs
– Charge subscribers based on actual usage
• Benefits
– Diversity  reduced capacity, reduced cost
– Large size  $/Ton, 11kV, eff systems & eqpt, life
– Containment  maintenance (AC vs WC), noise
– Cogeneration and use of waste energy
DISTRICT COOLING
• WHERE
– City Centers: large buildings & loads, premium space
– Airports: large buildings & loads, continuous operation
– Industrial Centers: many process loads, reliability
• DESIGN
– Low flow (1.5 gpm/ton)  high ΔT, small pipes & pumps
– Low supply chilled water temperature  smaller AS
– Check for laminar flow in FCU  poor cooling
– Reynolds number > 4000
– Ensure appropriate ΔT on airside of heat exchanger
YGFC FAN COIL UNIT
• POINTS TO NOTE!
– THIS IS A ‘HIGH VOLUME’ PRODUCT - SIMPLE
SPECIFICATION ALLOWS LOW COST & SPEEDS UP LEAD
TIMES
– TARGET LOW END SPEC. PROJECTS, AND SALES TO
DISTRIBUTORS AND END USERS
– LESS RANGE OF OPTIONS & SQ’S WHEN COMPARED TO
‘EUROPEAN’ FCU’S
– FCU CASING NOT THE MOST ATTRACTIVE!
– ARE YOU ABLE TO ORDER & HOLD STOCK UNITS??
YGFC FAN COIL UNIT
• POINTS TO NOTE!
– THERMOSTATS & CONTROLS AVAILABLE FROM ASIA
PACIFIC ARE NOT CE CERTIFIED
– VALVES ARE NOT FACTORY FITTED
– FILTER REMOVAL ON CEILING CONCEALED UNIT IS
DIFFICULT AS IT REQUIRES SCREW REMOVAL
– EUROVENT CERTIFICATION WILL BE MADE LATE 2006
YGFC SOFTWARE
YORK DESIGNED,
INDEPENDENT OF YORKWORKS
YGFC SOFTWARE
- GENERATES TECHNICAL
SCHEDULES…
- GENERATES
WORKS
ORDER
YGFC SOFTWARE
•ALSO GENERATES…
-OPTIMUM FCU
CONTAINERISATION
FOR SHIPPING
-CATALOGUE DATA
SHEETS & TECHNICAL
SPECIFICATIONS
-PRICE SUMMARY
WHO TO CONTACT….
TECHNICAL
James Long (james.long@yorkna.com.cn),
DOCUMENTATION
Alan Hinton (alan.hinton@uk.york.com)
PRICING
Alan Hinton (alan.hinton@uk.york.com)
SQ’S & SQ
PRICING
James Long (james.long@yorkna.com.cn), c.c. to
Alan Hinton (alan.hinton@uk.york.com)
ORDERS
Jackey Que (jackey.que@yorkna.com.cn), c.c to
James Long (james.long@yorkna.com.cn)
SHIPPING
Erica Wang (erica.wang@yorkna.com.cn)
WARRANTY
Ding yue (ding.yue@yorkna.com.cn), c.c to Kevin
Lau (kevin.lau@yorkna.com.cn)
SOFTWARE
Alan Hinton (alan.hinton@uk.york.com)
Download