‘YGFC’ FAN COIL UNITS NEW PRODUCTS - 2006 YGFC FAN COIL UNIT • FACTORY LOCATED IN GUANGZHOU, CHINA – CAPACITY = 300,000 UNITS/YEAR = 1,000 UNIT/DAY! • CERTIFICATION – ISO 9001:2000, GB/T 19002:2000 CERTIFIED FACTORY – GB/T 19232:2003 CERTIFIED TEST LAB (ONLY 2 IN CHINA) FEATURES YGFC FAN COIL UNIT – CE (TUV) CERTIFIED – CONFIGURATION: CONCEALED, CABINET, HORIZONTAL, VERTICAL – COIL: 2 CHOICES, CONVENTIONAL OR DISTRICT COOLING – 10 SIZES (70-600 L/S, 1-15KW COOLING) – DRAIN PAN: DIE-FORMED, ANTI-RUST PAINTED, INSULATED – MOTORS: DIRECT DRIVE, THERMAL PROTECTION, BALL BEARING • TESTING – COIL PRESSURE TESTED AT 2400 KPA – MOTOR TESTED FOR EARTH LEAK AND CURRENT YGFC FAN COIL UNIT • SPECIFICATION – 3 OR 4 ROW COIL, WORKING PRESSURE 1600kPa – FILTER: 6mm NYLON – 1mm GALV.STEEL CASING FOR ADDED NOISE REDUCTION – INSULATED PAINTED DRAIN PAN – 10mm COATED FIBREGLASS INSULATED FAN DECK & COIL SECTION YGFC FAN COIL UNIT • OPTIONS – CASING: FULLY POWDER COATED – FILTER: 25 MM ALUMINUM – FINS: HYDROPHILIC, EPOXY COAT, COPPER – STAINLESS STEEL DRAIN PAN – MOTORS: IP 23 AS STANDARD, 42 & 54 AS OPTION – 6mm CLOSED CELL INSULATED RETURN PLENUM, ELECTRIC HEATER YGFC FAN COIL UNIT • ADVANTAGES – CHOOSE FROM 10 MODEL SIZES TO MATCH ROOM NEED – LOW HEIGHT (250MM) SUITABLE FOR TOWER BLOCKS – WHISPER-QUIET OPERATION – RESISTANCE TO CORROSION – ADAPTABILITY TO STANDARD OR DISTRICT COOLING APPLICATION YGFC FAN COIL UNIT • ADVANTAGES – EASE OF MAINTENANCE – LOW RISK OF LEAKS FROM DRAIN PAN AND COIL CONNECTIONS – LOW RISK OF BEARING WEAR – LONGER MOTOR LIFE – LONGER UNIT LIFE! – ECONOMICAL LIFE CYCLE DISTRICT COOLING • Definition – Produce chilled water at a central plant – Distribute to buildings for AC needs – Charge subscribers based on actual usage • Benefits – Diversity reduced capacity, reduced cost – Large size $/Ton, 11kV, eff systems & eqpt, life – Containment maintenance (AC vs WC), noise – Cogeneration and use of waste energy DISTRICT COOLING • WHERE – City Centers: large buildings & loads, premium space – Airports: large buildings & loads, continuous operation – Industrial Centers: many process loads, reliability • DESIGN – Low flow (1.5 gpm/ton) high ΔT, small pipes & pumps – Low supply chilled water temperature smaller AS – Check for laminar flow in FCU poor cooling – Reynolds number > 4000 – Ensure appropriate ΔT on airside of heat exchanger YGFC FAN COIL UNIT • POINTS TO NOTE! – THIS IS A ‘HIGH VOLUME’ PRODUCT - SIMPLE SPECIFICATION ALLOWS LOW COST & SPEEDS UP LEAD TIMES – TARGET LOW END SPEC. PROJECTS, AND SALES TO DISTRIBUTORS AND END USERS – LESS RANGE OF OPTIONS & SQ’S WHEN COMPARED TO ‘EUROPEAN’ FCU’S – FCU CASING NOT THE MOST ATTRACTIVE! – ARE YOU ABLE TO ORDER & HOLD STOCK UNITS?? YGFC FAN COIL UNIT • POINTS TO NOTE! – THERMOSTATS & CONTROLS AVAILABLE FROM ASIA PACIFIC ARE NOT CE CERTIFIED – VALVES ARE NOT FACTORY FITTED – FILTER REMOVAL ON CEILING CONCEALED UNIT IS DIFFICULT AS IT REQUIRES SCREW REMOVAL – EUROVENT CERTIFICATION WILL BE MADE LATE 2006 YGFC SOFTWARE YORK DESIGNED, INDEPENDENT OF YORKWORKS YGFC SOFTWARE - GENERATES TECHNICAL SCHEDULES… - GENERATES WORKS ORDER YGFC SOFTWARE •ALSO GENERATES… -OPTIMUM FCU CONTAINERISATION FOR SHIPPING -CATALOGUE DATA SHEETS & TECHNICAL SPECIFICATIONS -PRICE SUMMARY WHO TO CONTACT…. TECHNICAL James Long (james.long@yorkna.com.cn), DOCUMENTATION Alan Hinton (alan.hinton@uk.york.com) PRICING Alan Hinton (alan.hinton@uk.york.com) SQ’S & SQ PRICING James Long (james.long@yorkna.com.cn), c.c. to Alan Hinton (alan.hinton@uk.york.com) ORDERS Jackey Que (jackey.que@yorkna.com.cn), c.c to James Long (james.long@yorkna.com.cn) SHIPPING Erica Wang (erica.wang@yorkna.com.cn) WARRANTY Ding yue (ding.yue@yorkna.com.cn), c.c to Kevin Lau (kevin.lau@yorkna.com.cn) SOFTWARE Alan Hinton (alan.hinton@uk.york.com)