Laboratory Impex Systems Ltd A Brief Update Jeff Sawyer September, 2012 HPIC Los Alamos, NM Laboratory Impex Systems (LIS) • Specialize in the design and manufacture and supply of health physics, radiation protection, and process instrumentation / systems – Stand alone monitors (alpha-beta aerosols, liquids, various gases, dose rate) – Installed systems – Stack sampling and stack monitoring – and stack flow measurement – Software for compliance monitoring • Established in 1976 Continuous Monitoring Stations CMS 2 Area Gamma Monitor SmartCAM Alpha/Beta in Air Monitor Some More News • SmartCAM AB+ passed seismic testing • The Testing was carried out at the Earthquake Engineering Laboratory at Bristol University. • Used a tri-axial vibratory shaker table testing, in accordance with IEEE Std 344-2004, IEEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations. Testing was carried out in three mutually perpendicular test axes in accordance with IEEE Std 344-2004, Para 8.1.5.2 CMS-GAMMA Area Monitor • • • • • • • • • • Backlit LCD with text and graphics One or Two Detectors GM Detectors can be 1,000 meters away Can use UDI – Universal Detector Interface Variety of Detector Types and Ranges Battery Back up RS-485 or Ethernet communications Relays and two analog outputs Stainless Steel Construction Data accessible via standard Web browser GM Detector Ranges • Standard GM Detectors – GDI RANGE (Integrated Electronics, No UDI Required) – GDI-1304 0.01 rem/h – 1,000 rem/h – GDI-1314 1 mrem/h – 300 rem/h – GDI-1324 0.01 mrem/h – 10 rem/h – GDI-1202 0.01 mrem/h – 4 rem/h – GDI-1301 0.01 rad/h – 1,000 rad/h – GDI-1313 0.001 rad/h – 300 rad/h – GDI-1321 0.3 mrad/h – 10 rad/h • Other Detectors and Ranges Available! • UDI used for other detector types Ion Chamber • ICI-1 Ion Chamber Interface – Current to TTL frequency converter • ICD-1 Ion Chamber – Pressurized Chamber – 5 mR/h to 5,000 R/h • 137Cs live-zero source – 4 µCi or 148 kBq • <10 m cable length Hot Cell Monitor HC833 • Simple, panel mount high range monitor • Several different detectors – Up to 1,000 R/h • Analog, log scale • Simple Alarms • Relay Outputs • Stainless steel housing Rack-mount Monitoring Systems • 19” rack mount • Complete dose rate or particulate monitoring solution • Network using RS-485 or Ethernet • Key switch and password protected • Simple LCD text display • Remote light panels and audible annunciation Noble Gas and Radioiodine • Standard Skids • Particulate detector or prefilter • 2-inches of lead shielding • 4π lead shield arrangement • Electronics can mount on skid or remotely • RS-485 or Ethernet • Interface to 9205EMS Data Management System • Various types of vacuum pumps available SmartCAM Continuous Air Monitor Alpha Beta CAM • Alpha spectrum analysis with peak fitting algorithm used in differential spectrum • Temperature and pressure spectrum stabilization (Patented) • Detachable head assembly for remote monitoring • Gamma dose-rate sensor (option) SmartCAM Display • Easy to use, easy to navigate, touch screen display • Continuous Display of – Concentration (i.e. DAC) by Nuclide – Dose (i.e. DAC-h) by Nuclide – Sample Flow – Integrated Sample Volume – Temperature – Dose Rate (optional) – Pressure Recent Design Changes • Upgraded to a more flexible detector cable – Now using a more rugged, easier to use connector • Added ModBus support (allows ProfiBus) • NRTL tested to UL 61010-1/CSA-C22.2 No. 61010-1 Second Edition: Electrical Equipment for Measurement Control and laboratory Use – For more information, see :http://ulstandardsinfonet.ul.com/scopes/scope s.asp?fn=61010-1.html • 47-mm filter in addition to standard cards Stack Monitor for Positrons • Used for compliance monitoring • Direct measurement of positron activity • Simple interface for Daily, Weekly, Monthly, and Annual Releases • Used with air injection pumps Vacuum Pumps • Rotary vane pump – Rebuild “annually” • Air injection pump – No moving parts – Quieter and cooler – Compressed air required – About 80 psi and 1 cfm LIS Cyclotron Installations Seattle Kennewick Minneapolis Rochester Chicago Detroit Hartford East Rutherford Cleveland Columbia St Louis Sacramento Charlottesville Las Vegas Los Angeles Winston Salem San Diego Little Rock Phoenix Lubbock Dallas Boston Philadelphia New Haven Beltsville Baltimore Denver Albuquerque Albany Memphis Birmingham Knoxville Atlanta Augusta Orlando Tampa Fort Lauderdale Alarm and Data Management System – 9205EMS • 9205 – Generic Network Software Package • Supports multiple communications protocols • Real Time Display of Measured Values • Generates and Logs Alarms • Accumulates Stack Discharge (Daily, Weekly, Monthly, Annual) • Database of results (History) • Automated Reports in Word format Stack Flow Measurement • Pitot tube averages flow across duct – Stainless steel – Proper placement important • DP-2001 Differential Pressure – Calibrated for correct pressure range • 4 to 20 mA Signal to CMS-Pet – Standard Ethernet cable used Stack Sampling Systems • • • • • • Shrouded probes (1” and 1.5”) Meet ANSI N13.1-1999 Licensed by Texas A&M NQA-1 Quality Assurance Seismic analysis performed Design capability for new applications • Gas sampling probes • Various mounting flanges used System Use With Air Cannons • Flow rates cannot be accurately measured after the air cannon because of turbulence • Measuring the concentration prior to the air cannon offers better statistics for lower concentrations • Software can add in the additional air allowing it to report proper release concentration results • Monitoring before the air cannon allows proper measurement and reporting of activity releases Questions? • Jeff Sawyer • • • • Sales Manager, North America Cellular: 920-889-2983 jeff.sawyer@labimpex.com www.labimpex.com