Agenda BPL in SMARTGRID and AMI = Working Reality of one communication platform Basic parameters and features BPL AMI Architecture in CEZ Field Test Results Risks and future possibilities www.corinex.com 1 G.Hn Markets Focus Purpose Promote G.hn Technology and Ensure Interoperability of Products Based on the G.hn Spec Board of Directors Board of Directors Contributions Certification & Interoperability Smart Grid Utilities Home Grid is the commercial companion group for G.hn Worldwide industry representation Corinex is Chair of the AMI Working Group for this impressive new standard with mandate to: 1. Develop Clean Tech product standards for devices with G.hn technology. These standards will be used to access Clean Tech properties of the technology; 2. Lab testing and certification process to verify those properties; 3. Establish methods of calculation of the carbon offsets for devices having Clean Tech properties ©2009 All Rights Reserved Promoters Contributors UNH 2 2 Features: Full Corinex BPL Architecture Benefits Corinex BPL Solution Supports All Needs of AMI and SmartGrid Applications ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Simple meter interoperability Integrated ripple control system – broadcasting in all cluster within a minute Proven communication performance (AMI, SmartGrid, EV) The industry lowest cost/performance ratio compared to all communication technologies Unmatched performance (up to 40Mbps) and reliability Self adapt and auto-healing mechanism Interoperable solution for multi-meter vendor support Real-time event reporting and meter profile reading Leadership in open standard (G.hn) solution Security encryption support Advanced data integrity and validation (in meter and HES) Real-time demand load management (within seconds) Remote firmware upgrade (open for future needs) www.corinex.com 3 Meter Interoperability Corinex Technology is Meter Agnostic and has four components. Solution Components Net Perform L&G meter Grid Apps Smart Grid Connect Grid Intel ZPA meter Net Admin Mikroelektronika meter www.corinex.com Corinex Metering software in Smart Communication Module Corinex Wide Band PLC Gateway 4 Integrated Ripple Control System Corinex- BPL specific features ■ ■ ■ ■ ■ ■ The module has a broadcast address The module is able to accept a broadcast (e.g. a telegram for everybody- only right ones react) Reaction for telegram if address part is OK is: change of tariff/output, change of virtual output change of limiter, change of disconnector, etc. Similar actions as above enabled in TOU Above actions are enabled by unicast and single address command A possibility to operate so called “virtual relay- e.g. home automation” (nice to have) 5 BPL Network Architecture in CEZ deployment The BPL network on low voltage is connected to the CEZ 3G WAN for backhaul to central servers Collection Engine 234 Meters In TU_0848 DB Access Router WAN Corinex + Landis BPL Meter in MDU Buildings Transformer Station Via 3G Router Corinex + Landis BPL Meter in Residential Houses Transformer Station Via 3G Router Corinex AMI LV Network In TU_0848 Reading Conditions: • Time Out 20s per read • Max 5 Retry per Read CEZ has measured the performance of meter reading to ensure it meets/exceeds the requirements for their smart grid applications www.corinex.com 6 Broadband Implementation available for MDM The deployment in Vrchlabí was chosen to trial the broadband technology for smart grid applications Example -Trafo TU 848 AMM Topology CEZ is piloting new broadband over powerline technology to the meter, which achieved high bandwidth and reliability for smart grid applications 7 www.corinex.com 7 Pardubice Deployment Pardubice 2012 PA_0619 Deployment without Repeaters – Q1 2012 Average meter reading success rate of 99.705% without repeaters Deployment Approach in 3 steps: PA_0637 PA_0087 1108 single phase meters 112 three phase meters 1220 total meters 1. Planning and Hardware Installation - Completed by CEZ without assistance from Corinex. 2. Network Optimization - Accomplished by Corinex in less than 2 days: • Only 1.6% meters not reporting • Consider this step closed and will return after the CEZ 60% test 3. Clean up and 100% connectivity – Connected the remaining 1-2% in February BPL has superior connectivity and performance to any other PLC deployments www.corinex.com 8 8 Deployment without repeaters Pardubice Substations Red_Substation 3 Corinex Gateways at the Substation ● 0 Repeater Gateways in the field ● 352 meters ● The most remote meter: 390 m ● Yellow_Substation 3 Corinex Gateways at the Substation ● 0 Repeater Gateways in the field ● 451 meters ● The most remote meter: 470 m ● Blue_Substation 3 Corinex Gateways at the Substation ● 0 Repeater Gateways in the field ● 348 meters ● The most remote meter: 310 m ● Approx. 500 m All 1151 meters have connectivity with the NOC! BPL to the meter: known and unknown PROVEN ■ BPL technology has an unparalleled reading performance in areas where tested ■ Easy to deploy ■ Cost comparable with narrow band solution in absolute terms, and hundreds times lower in price per Mb ■ Technology is supported by strongest silicon vendors (TI, Marvell, Intel). ■ In various market segments: EV, SmartGrid, to the meter. OPEN ■ It is a new technology. One needs to better understand what it cannot do. ■ Solution can be further enhanced, benefiting from the speed and reliability of the technology – it is not fully exploited yet. ■ To lower the risk it would be beneficial to expand number of meter vendors adopting the technology (currently five in Europe) ■ To be able to scale up to 1 million meters + it would be good to have a concentrator – it is on the roadmap and will be introduced in September 2012. It will enable solution for up to 30 mil meters. ■ Vulnerable to the limited knowledge about its actual cost and performance www.corinex.com 11 Thank You Corinex Communications Corp. #1200 – 570 Granville Street Vancouver BC, Canada V6C 3P1 Tel: 604 - 692 - 0520 Fax: 604 - 694 - 0061 E-mail: saleslead@corinex.com www.corinex.com Corinex Communications a.s. Ambrova 6821 01 Bratislava 37 Slovak Republic, Europe Tel.: +421 - 2 - 59 - 212 - 000 Fax: +421 - 2 - 59 - 212 - 222 E-mail: allglobal@corinex.com Corinex Communications Corp. B-2910, Jiahe Huaqiang Building, 3006 Shennan RD, Futian District, Shenzhen, China Postal Code: 518031 Tel: +86-755-8367 7675 12