Highlights of the new STEP 7 Version
Automation and Drives
Introduction
SIMATIC Software
STEP 7 V5.4
The new STEP 7 V5.4 will enter the market in April 2006, replacing STEP 7 V5.3 that has been shipping
since 02.2004
With STEP 7 V5.4 we have some new functions as
 Access protection on projects: Protected projects can be
opened by authorized users only.
SIMATIC Logon has to be installed on the programmer.
 SIMATIC Manager: Format for Date and Time can be
selected
 CAx-Data Export/Import for CAx Systems with XML format
(e.g. for CAD- or CAE-Systems)
 HW-Konfig: Read or write of data for the identification of
a module
 PROFINET IO: IRT Extensions
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 2
Automation and Drives
Access Protection
SIMATIC Software
STEP 7 V5.4
If SIMATIC Logon is installed, the Access Protection can be
activated for every project.
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 3
Automation and Drives
Access Protection
SIMATIC Software
STEP 7 V5.4
Login for the Administrator
The Admin creates a project password for this project
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 4
Automation and Drives
Access Protection
SIMATIC Software
STEP 7 V5.4
The users for the different roles in this project can be selected
via drag and drop.
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 5
Automation and Drives
Access Protection
SIMATIC Software
STEP 7 V5.4
SIMATIC Logon installed: When opening a protected project,
the user gets the logon dialog
SIMATIC Logon not installed: The user can open the
STEP 7 V5.4 project by using the project password
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 6
Automation and Drives
Access Protection : Change Log
SIMATIC Software
STEP 7 V5.4
Change Log for a Project with SIMATIC Logon
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 7
Automation and Drives
Access Protection : Change Log
SIMATIC Software
STEP 7 V5.4
Change Log for a Station with SIMATIC Logon
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 8
Automation and Drives
SIMATIC Manager
SIMATIC Software
STEP 7 V5.4
Format for Date and Time can be selected
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 9
Automation and Drives
SIMATIC Manager
SIMATIC Software
STEP 7 V5.4
FW-Download for redundant Slaves (e.g. IM 153-2)
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 10
Automation and Drives
CAx-Data Export / Import
SIMATIC Software
STEP 7 V5.4
CAx-Data Export for CAx Systems
(e.g. CAD- or CAE-Systems) in XML format
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 11
Automation and Drives
Hardware Configuration
SIMATIC Software
STEP 7 V5.4
Identification data for the module
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 12
Automation and Drives
Hardware Configuration
SIMATIC Software
STEP 7 V5.4
Write identification data to PROFIBUS DP Modules in redundant Mode
(via “Accessible Nodes").
The interface module (IM) has to support this feature.
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 13
Automation and Drives
Insert copy of IO-Devices
SIMATIC Software
STEP 7 V5.4
Insert copy of IO-Devices into another Station with
better IP address handling
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 14
Automation and Drives
Optical components for PROFIBUS DP
SIMATIC Software
STEP 7 V5.4
The OLM for an optical ring in a configuration can now be
selected and specified
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 15
Automation and Drives
PROFINET IO
SIMATIC Software
STEP 7 V5.4
IRT Topology Editor - Offline
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 16
Automation and Drives
PROFINET IO
SIMATIC Software
STEP 7 V5.4
IRT Topology Editor - Offline
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 17
Automation and Drives
PROFINET IO
SIMATIC Software
STEP 7 V5.4
Offline / Online Comparison
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 18
Automation and Drives
PROFINET IO
SIMATIC Software
STEP 7 V5.4
Offline / Online Comparison
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 19
Automation and Drives
PROFINET IO
SIMATIC Software
STEP 7 V5.4
Hardware Configuration for CP1616
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 20
Automation and Drives
Versioning
SIMATIC Software
STEP 7 V5.4
Archive projects with the Option package SIMATIC Version Trail
SIMATIC Industrial Software STEP 7 V5.4 – Highlights
A&D AS FA PS 20-March-06 , 21
Download