PVSYST V6.20 18/03/14 Page 1/4 Grid-Connected System: Simulation parameters Project : Grid-Connected Project at Almere Almere Country Latitude Legal Time Albedo Almere 52.4°N Longitude Time zone UT+1 Altitude 0.20 Synthetic - Meteonorm 6.1 Geographical Site Situation Time defined as Meteo data: The Netherlands 5.2°E 1m L A I R T t s y s V P Simulation variant : system 2 - Silevo v2 Simulation date 11/03/14 10h52 Simulation parameters Tilt Collector Plane Orientation Models used Transposition 40° Azimuth Perez Diffuse 0° Erbs, Meteonorm Free Horizon Horizon Near Shadings No Shadings PV Arrays Characteristics (2 kinds of array defined) PV module Not Specified Model Manufacturer TriexTM U-Series 295W Silevo, Inc Sub-array "Sub-array #1" Total number of PV modules Array global power Array operating characteristics (50°C) In series Nb. modules Nominal (STC) U mpp 8 modules 8 2360 Wp 422 V In parallel Unit Nom. Power At operating cond. I mpp 1 strings 295 Wp 2206 Wp (50°C) 5.2 A Sub-array "Sub-array #2" Total number of PV modules Array global power Array operating characteristics (50°C) In series Nb. modules Nominal (STC) U mpp 8 modules 8 2360 Wp 422 V In parallel Unit Nom. Power At operating cond. I mpp 1 strings 295 Wp 2206 Wp (50°C) 5.2 A Arrays global power Nominal (STC) Module area 5 kWp 27.0 m² Total Inverter Model Manufacturer Operating Voltage Total 16 modules Sunny Tripower 5000 TL-20 SMA 245-800 V Unit Nom. Power 5.00 kW AC Sub-array "Sub-array #1" Sub-array "Sub-array #2" Nb. of inverters Nb. of inverters 1 * MPPT 0.52 1 * MPPT 0.48 Total Power Total Power 2.6 kW AC 2.4 kW AC Total Nb. of inverters 1 Total Power 5 kW AC PV Array loss factors Array Soiling Losses Thermal Loss factor Wiring Ohmic Loss PVsyst Evaluation mode Uc (const) 20.0 W/m²K Array#1 Array#2 Global 1742 mOhm 1742 mOhm Loss Fraction Uv (wind) 1.0 % 0.0 W/m²K / m/s Loss Fraction Loss Fraction Loss Fraction 2.0 % at STC 2.0 % at STC 2.0 % at STC PVSYST V6.20 18/03/14 Page 2/4 Grid-Connected System: Simulation parameters (continued) Module Quality Loss Module Mismatch Losses Incidence effect, ASHRAE parametrization System loss factors Wiring Ohmic Loss User's needs : PVsyst Evaluation mode IAM = 1 - bo (1/cos i - 1) Loss Fraction Loss Fraction bo Param. 1.5 % 1.0 % at MPP 0.04 L A I R T t s y s V P Wires Unlimited load (grid) 47 m 3x2 mm² Loss Fraction 2.0 % at STC PVSYST V6.20 18/03/14 Page 3/4 Grid-Connected System: Main results Project : Grid-Connected Project at Almere Simulation variant : system 2 - Silevo v2 System type tilt Model Nb. of modules Model Unlimited load (grid) Main system parameters PV Field Orientation PV modules PV Array Inverter User's needs Grid-Connected 40° azimuth TriexTM U-Series 295W Pnom 16 Pnom total Sunny Tripower 5000 TL-20 Pnom L A I R T t s y s V P Main simulation results System Production Produced Energy Performance Ratio PR Specific prod. 4458 kWh/year 84.2 % Normalized productions (per installed kWp): Nominal power 4720 Wp 6 945 kWh/kWp/year Performance Ratio PR 1.0 PR : Performance Ratio (Yf / Yr) : 0.842 Lc : Collection Loss (PV-array losses) 0.35 kWh/kWp/day Ls : System Loss (inverter, ...) 0.14 kWh/kWp/day Yf : Produced useful energy (inverter output) 2.59 kWh/kWp/day 5 0° 295 Wp 4720 Wp 5.00 kW ac 4 Performance Ratio PR Normalized Energy [kWh/kWp/day] 0.8 3 0.6 0.4 2 0.2 1 0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov 0.0 Dec Jan Feb Mar Apr May Jun Jul Aug Sep system 2 - Silevo v2 Balances and main results GlobHor T Amb GlobInc GlobEff EArray E_Grid EffArrR kWh/m² °C kWh/m² kWh/m² kWh kWh % % January 19.2 2.88 33.4 32.2 143.4 133.9 15.87 14.81 February March April May June July August September October November December 36.0 68.3 108.1 145.5 146.7 144.7 127.9 84.0 50.9 23.5 14.6 3.90 6.17 9.26 13.14 15.67 17.08 17.79 14.75 10.60 6.56 3.41 56.1 91.1 121.5 146.4 140.0 141.9 140.0 105.2 77.1 42.6 26.4 54.2 88.1 117.1 141.1 134.6 136.6 135.1 101.6 74.5 41.2 25.4 241.7 387.2 513.2 608.3 575.8 586.4 576.3 438.5 326.2 181.6 112.3 228.5 368.0 490.3 579.4 547.6 559.0 549.7 418.4 309.9 169.8 103.6 15.94 15.73 15.63 15.36 15.22 15.29 15.23 15.42 15.66 15.75 15.77 15.07 14.95 14.93 14.64 14.47 14.58 14.53 14.71 14.87 14.73 14.54 Year 969.5 10.14 1121.6 1081.7 4690.8 4458.1 15.47 14.70 Legends: PVsyst Evaluation mode GlobHor T Amb GlobInc GlobEff Horizontal global irradiation Ambient Temperature Global incident in coll. plane Effective Global, corr. for IAM and shadings EArray E_Grid EffArrR EffSysR EffSysR Effective energy at the output of the array Energy injected into grid Effic. Eout array / rough area Effic. Eout system / rough area Oct Nov Dec PVSYST V6.20 18/03/14 Page 4/4 Grid-Connected System: Loss diagram Project : Grid-Connected Project at Almere Simulation variant : system 2 - Silevo v2 Main system parameters PV Field Orientation PV modules PV Array Inverter User's needs System type tilt Model Nb. of modules Model Unlimited load (grid) Grid-Connected 40° azimuth TriexTM U-Series 295W Pnom 16 Pnom total Sunny Tripower 5000 TL-20 Pnom L A I R T t s y s V P 0° 295 Wp 4720 Wp 5.00 kW ac Loss diagram over the whole year 969 kWh/m² Horizontal global irradiation +15.7% Global incident in coll. plane -2.6% -1.0% 1082 kWh/m² * 27 m² coll. Effective irradiance on collectors efficiency at STC = 17.51% PV conversion 5121 kWh Array nominal energy (at STC effic.) -2.6% -2.6% PV loss due to temperature Module quality loss -1.0% Module array mismatch loss -1.0% Ohmic wiring loss Array virtual energy at MPP -3.7% Inverter Loss during operation (efficiency) 0.0% -0.4% 0.0% 0.0% Inverter Loss over nominal inv. power Inverter Loss due to power threshold Inverter Loss over nominal inv. voltage Inverter Loss due to voltage threshold Available Energy at Inverter Output -0.9% AC ohmic loss 4500 kWh 4458 kWh PV loss due to irradiance level -1.5% 4691 kWh PVsyst Evaluation mode IAM factor on global Soiling loss factor Energy injected into grid