Colibri™ TTC: Hand-Held Health Physics Communication ALARA* Platform Dr. Radu Vasilache Canberra Packard CE GmbH Andreea Olteanu Canberra Packard SRL Michel Rotty Canberra Semiconductor, Olen SRRp 2010 Annual conference 1 CSP – smart probe based systems for workplace monitoring 2 CSP Canberra Smart Probes Monitors for CSP family CSP –COM communication modules Review & Applications R.A. Vasilache et al. – Colibri STTC SMART PROBES SCALE Canberra smart probes (CSP) Probe is 100% independent from Meter SMARTNESS LEVEL All user parameters are set inside probe (alarm set points) digital smart or « intelligent » probes Probe is 90% independent from Meter All user parameters, are set in read-out Meter analogue smart probes Probe is dependant of Meter Probe remains Cable & Meter dependent Dumb/conventional probes Another age… 3 R.A. Vasilache et al. – Colibri STTC Digital Smart or Intelligent Probes Serial link Digital PROBE readout SMARTNESS LEVEL CABLE 4 Detector Preamplifier Probe ID Cal coefficients Data logging HVPS (historical data) Amplifier Discriminator Signal processing R.A. Vasilache et al. – Colibri STTC probe ID defines readout unit Alarm set points Canberra Smart Probes (CSP) Serial link SMARTNESS LEVEL CABLE Detector Preamplifier Probe ID Cal coefficients HVPS Amplifier Discriminator Signal processing It’s a monitor! additional: Alarms setpoints are stored inside the probe Stores 1000 data points 5 R.A. Vasilache et al. – Colibri STTC Canberra What is a Canberra SMART probe? High Voltage Power Supply in Probe! Hot plug on meter without powering down instrument Measurement starts immediately without any necessary setup Measurement is not cable quality dependent! Calibration data in probe memory Each probe is independent from meter Each probe is separately calibrated Meter remains available during probe calibration process Probe includes HVPS, Amplifier, discriminator(s) & signal processing Calibration data and ID Alarm set-points (10 for each unit to display) and default/last selection Data Logging (up to 1000 points in probe memory!) independant 6 CSP probe will function on it’s own can be connected directly to PC or other interface R.A. Vasilache et al. – Colibri STTC CSP Monitors Avior, Radiagem 2000, Colibri, or CSP-S & CSP-DLL 7 Tele-STTC SABG-15+ SA/SB/SAB/SABG-100 SA/SB-20 STTC SN-S SG-1R SPAB-15 SX-2R SG-2R SG-1R & SG-2R : Search Gamma Search probe SX-2R X-Ray Search probe STTC wide range SASBSABG100 Contamination SA-20 :contamination Contamination probe SPAB 15 :SABPIPS detector probe SN-S :::SB-20 Neutron probe SABG-15+ Tele STTC :measurement probe 1” β or 2”aor NaI scintillation probe window scintillation Gamma doserate 0.3µSv/h – 10Sv/h probe 100cm² active area ZnS (A) thin plastic (B)probe scintillation No to crosstalk !(cps) 15cm² Pancake GM neutron detection thin Pole version of STTC 2 energy) With discriminator discriminator (high – low low With (high Time To Count single GM Display: c/s, Bq Bq /cm 20cm² active area With energy discriminator (aenergy) -highE, b -lowE, a+b eq or eq– general purpose abgHe3 lightweight (1.3kg), tube fiber Extremely light (2lbs) carbon 2 in cps, Sv /hplastic equivalent dose rate bothE) also for contamination applications ZnS (A)or or thin scintillation (B) probe Display: c/s, Bq eq eq or Bq eq/cm improved ergonomy Pressure Phoswichresistant (AB) ZnS and thin plastic scintillator With energy discriminator (a -highE, b -lowE, a+b bothE) Phoswich (ABG) ZnS and thick plastic scintillator 8 R.A. Vasilache et al. – Colibri STTC With energy discriminator (a -highE, bg -lowE, a+bg bothE) « Monitors » for CSP probes Detector cable Detector cable Radiagem 2000 SG 2R SG 1R SX 2R Radiagem, Personal Portable Dose Rate and Survey Meter SA/SB 20 SABG-15+ SA/SB/SAB/SABG 100 15 Internal dose rateSPAB GM detector Colibri, Personal Portable Dose Rate and Enhanced Survey STTC CSPS: CSP connected direcly on PCUSB 0.3µSv Meter Detector– 100mSv/h SN-S cable Avior : Desktop READ OUT unit Fastresponse (new algorithm) Calibration via PCdetector Internal dose rate TTC No internal detector Connect to single external CSP via detector cable Choose alarm 0.3µSv – 10Sv/h (>levels 0.1µSv/h) CSPS / CSP DLL Connect to single CSP via detector cable Either internal doseratemeter, or monitor for external CSP Test measurements Connectable to single external CSP via detector cable Avior 9 probe Ratemeter, Integrated Scaler-Timer mode CSP DLL : CSP connected direcly on PC or Simultaneous internal doseratemeter and monitor for R.A. Vasilache et al. – Colibri STTC Colibri Main Features Large touch screen backed up with keyboard Internal TTC detector 300nSv/h->10Sv/h Simultaneous display : Internal dose rate External (depending on probe) dose rate Combined channel or Seperate Alarm : Visual, sound et vibration Li ion battery. 15h00 Battery life Integrated GPS (option) Bluetooth interface for accessories barcode reader or RFID reader headphones, mapping system CSP-COM BT 10 R.A. Vasilache et al. – Colibri STTC discrimantor Colibri modes of operation Background Calibration Source Scaler Radio isotope display Finder and Timer mode Multiple probe connection Comments Data substraction input logging (can be automatic) Auto datalog with SG-2R probe and Colibri with GPS Colibri file transferred to PC Upload of the file in an external software (SAVGIS, Google Map) 11 R.A. Vasilache et al. – Colibri STTC Application Measurement Traceability Entering user codes grants access to various functions depending on user profile User is identified! GPS : measurement is associated with GPS coordinates Barcode : measurement is associated with barcode reader -> localization Measurement can now be associated to : User : WHO ? Probe that was used to take the measurement : HOW ? Date stamp : Date and Time of measurement : WHEN ? Location (GPS, Barcode, RFID, …) : WHERE ? 12 Measurement can be centralized immediately without paperwork – real time becomes a fact! R.A. Vasilache et al. – Colibri STTC CSP-COM CSP-COM communication modules 13 From CSP Philosophy to Remote Monitoring Different CSP-COM modules for different applications : Wireless : Bluetooth : For cable replacement (compatible with Colibri & CSPS) WiFi : For networking activity through a centralized system RF 915MHz, RF 868MHz For networking activity through a centralized system long range – needs RF base stations Wired for networking application : RS 485 to re-use existing cabling Ethernet for enhanced networking abilities CSP COM modules integrate a rechargeable Li-ion battery, with a 12V power input are plugged on any CSP probe 14 R.A. Vasilache et al. – Colibri STTC « Monitors » Colibri with CSP-COM BT for CSP –COM modules CSP-DLL for CSP-COM modules Internal dose rate TTC detector external CSP probes can be connected One external CSP via detector cable via USB-hub, or networked via WiFi, RF, Up to 7 CSP probes with CSP-COM BT RS485 and Ethernet Simultaneous internal doseratemeter and Applications are … unlimited monitor for those CSP probes in your BT Detector application cable Ethernet WiFi RF RS485 WiFi / RF USB receiver RS485 CSP DLL 15 R.A. Vasilache et al. – Colibri STTC Ethernet CSP as basis for Remote Monitoring Colibri : the transition Network instrument, from wired to wireless Allows remote monitoring in hot areas Allows mapping with its GPS, Barcode reader capabilities 16 R.A. Vasilache et al. – Colibri STTC and RFID CSP-DLL Example 17 R.A. Vasilache et al. – Colibri STTC CSP-COM Benefits CSP COM are modules to improve communication between a CSP monitor and the CSP to : Improve communication distance Centralize measurements in one point Multiplex communications This brings me : Easier manipulation by getting rid of the cable 18 R.A. Vasilache et al. – Colibri STTC CSP HP Products all together Colibri MIP10 Digital Avior CSP DLL (mono & Network) Radiagem CSP Monitors & Survey Meters PNK-R Handle-R Audio-R CSP Pole / Tele STTC CSP COM Modules CSP Accessoires SG 1R SABG 15+ STTC SA/SB 20 SABG 15 SPAB 15 SX 2R SG 2R CSP Probes SA/SB/SAB/SABG 100 SN-S STHF-R Compatible Probes 19 R.A. Vasilache et al. – Colibri STTC Thank you! No questions, right? 20 R.A. Vasilache et al. – Colibri STTC