Home EMC Compliance systems Emissions EN series Def Stan FCC As/Nz and EMC Pre-Compliance systems Immunity IEC61000-4-series and RF monitors and meters Harmonics & Flicker Safety at work IEC61000-3-2 IEC61000-3-3 ICNIRP All from the Experts at Laplace Instruments Ltd Selector Make emissions measurements to check emission compliance? Test for susceptibility/immunity? Or both? Test for Harmonics & Flicker compliance? Looking for ancillaries such as reference sources, antennas, LISNs etc…..? See the overview and selector chart EMC Compliance Testing – the essential guide Emissions RFG- core system RF100 probes IEC61000-4-3 Radiated RF IEC61000-4-2,4,5,11 IEC61000-4-6 LF effects Conducted RF SA1020 pre-amp RF1000 (1GHz) or RF2000 (2GHz) or RF3000 (3GHz) Synthesiser Radiated All EMC emission standards Appliance? EN55014 LISN or PLIP RF Absorbing clamp Luminaire? EN55015 If emissions Broadband? EUT size……… Large and small OATS Anechoic chamber ERS Emissions Reference Sources LETIS or RFIC-46 RF200 RF230 antenna Small? Test cell Lc300/2 or Lc600 30MHz – 3GHz Filtered feeds CDNs AC1000 clean Power source ECOMPACT4 Integrated test system Information CDNs Laplace product ESD Incl PC software Clamps Camera & lighting Loops Anechoic chamber IEC61000-3-2 IEC61000-3-3 AC2000 analyser RF11xx, RF12xx or RF13xx Power Amplifiers RF300 large Loop antenna All other EMC standards RF200, RF230 or CTS011 miniature antenna RF600 and RF700 Ambient filters Harmonics & Flicker Routemap SA1000 (1GHz) or SA3000 (3GHz) analyser Conducted RF800 or RF910 or RF915 Pre-selector Susceptibility (immunity) Key Incl. in CLIENTS LETIS RFP-04CE Field probe +fibre link option HARMONICS & FLICKER H&F Compliant with: IEC61000-3-2 IEC61000-3-3 AC2000A AC1000A Clean power source. Provides up to 1kW (4A) of pure sine mains power. Output harmonic content: <0.1% THD Harmonic & Flicker analyser. Features: Automatic testing Automatic calculation of ‘variable’ limits Self contained instrument PC interface included Emissions………… Emission selector Emissions analyser Radiated – test cell Radiated – Antenna Radiated – Large Loop Antenna Radiated – Reference sources Radiated – Pre-amplifier Radiated – Near field probes or ? Conducted Conducted emissions Conducted selector Analyser and software LISNs Voltage probes EMC analysers and software SA1000-a High performance EMC analysers……. SA1002…………9KHz – 1GHz SA3000…………9KHz – 3GHz Compliant detectors (Pk, QP and Average) Pre-loaded limits in software. All results in Windows environment. Easy to use…. USB interface to any PC Input connects to any Laplace antenna or transducer. See also the RF910 and RF915 pre-selectors. Conducted Pre-selector Radiated Antennas LISNs Test Cell Voltage probes Reference sources Test cells Cells It does not get any easier than this……….. * Quick * Compact * Convenient Radiated Emissions to 3GHz Radiated Immunity to 3GHz Select Emissions or Immunity Two sizes:……. Lc300/2: up to 30cm cube EUT, benchtop model Lc600: up to 60cm cube EUT, floor standing Both provide IEC61000-4-3 testing to over 10V/m More details…… Access door open to EUT area Lc300/2-outer System configured with: •SA1000 emissions analyser •RF2000 synthesiser •RF1100 power amplifier •LETIS •RF1200 power amplifier More details…… Lc300/2 Lc300/2 Lc300/2-filter Filter connection plate to External services Access door open to internal filter connections. Aperture (hidden) provides access to EUT volume More details…… Advantages of test cells •Eliminate ambient •Known calibration •Compact size •Ease of use •Located in your own lab. •Convenience •Not dependant on the weather! Advantages specific to LaplaCell Cellnotes •Smallest size •Better field uniformity GTEM field - poor uniformity LaplaCell field - far better uniformity •Impedance matched for better results •Free space impedance is 377ohm (Ideal) •GTEM cells are 50ohm systems •Laplacell features impedance conversion to 200ohm •Much closer to ideal •Complies with IEC61000-4-20 •Latest standard for the calibration of cells •Built-in field sensor •Save cost and complexity Test chamber option Integrated system for immunity testing to IEC61000-4-3 in test chamber RF200 and RF230 antennas Test chamber Field sensor (RFP-04CE) With RS232 fibre optic interface (PCLK) Chamber Optional EUT monitoring Fibre optic cable (FOLK) EUT Antenna Synthesiser/ signal genny Power amplifier RF1000, RF2000 or RF3000 with –RH option (External sensor) RF11xx RF12xx or RF1300 System controller System software Switch Unit LETIS Pre-selector units RF910 RF910 and RF915 As specified by CISPR16 and recommended for conducted emission measurements if the EUT produces broadband noise. RF1000 or RF2000 These pre-selectors effectively pre-filter the incoming signal such that the analyser input is not overloaded by broadband energy. Not required if EUT produces narrowband noise. RF910 covers band B (150KHz – 30MHz) RF915 covers bands A and B (9KHz – 30MHz) Photo shows RF910 below SA1000 and PC Emissions Reference Sources ERS These sources can be used to simply check an established site prior to measurements, or To calibrate an unknown site. Note that the dominant source of measurement uncertainty for radiated emissions is the test site! ERS 1GHz reference source EMC3.5 3.5GHz reference source. Fully traceable to NPL Extremely compact Only 12 x 7 x 14cm 2MHz spacing Provides auto site calibration when used with SA1002 or SA3000 10 or 50MHz spacing Remote control option Antennas A range of antennas to cover most requirements. Antennas ARA Active receive antenna Compact, but same sensitivity as larger antenna RF300 Large loop antenna (Van Leen Loop) To CISPR15 CTS011 RF200 Broadband antenna 30MHz – 1GHz Standard EMC antenna For use on OATS or in test chambers Very small! About the size of your hand. For use in confined spaces RF meters and detectors TDM-200 RF power density meter. Trifield Internal antenna Ideal for RF signal strength field surveys. 0.5MHz to 3GHz TBM-100 Broadband meter An Electric field meter, Gaussmeter and RF field strength meter all in one small unit. Monitor and measure the field from AC power lines, video displays, ovens, LANs and mobile phones Gaussmeter: 40Hz –500Hz Electric field meter: 40Hz – 100KHz RF field meter: 100KHz – 2.5GHz T-MA-P Personal RF hazard warning detector Provides an audible warning if the RF field is close to the ICNIRP recommended limits Essential for all who work close to RF transmittersand cell base stations LISNs and Voltage Probes LISN LISN - Line Impedance Stabilisation Network Commercial range complies with CISPR16 Def Stan, Mil Spec and CISPR25 versions also available Up to 4 lines Up to 100A/phase Commercial range includes transient limiters PLIP Voltage probe As specified by CISPR16 For use when LISN is not appropriate. Includes opto-isolation and high voltage, fused connecting clips Immunity testing Immunity selector IEC61000-4-2 ESD ONYX16 simulator IEC61000-4-3 Radiated RF LaplaCell and ancillaries IEC61000-4-4 EFT ECOMPACT4 IEC61000-4-5 Surge ECOMPACT4 IEC61000-4-6 Conducted RF RFIC46 system + CDNs IEC61000-4-8 Power Mag. Field ECOMPACT4 (option) IEC61000-4-9 Pulsed Mag. Field ECOMPACT4 (option) IEC61000-4-11 Dips and Interrupts ECOMPACT4 LaplaCell systems RFIC systems ECOMPACT4 Standard system RF Immunity test RFI test-a IEC61000-4-3 requires EUT to be immersed in strong modulated RF fields over the range 80MHz – 1GHz, or higher! The specified techniques are fully incorporated into The Laplace test system comprising a LaplaCell, system controller and power amplifier. See CLIENTS for total automated solutions. Note that these systems work equally well with test chambers (FAC or SAC or stirred mode). EUT Feedback USB Any standard PC RF1000, RF2000 or RF3000 RF1100 and/or RF1200 or RF1300 RF Power RF level feedback Pre-amp & near field probes RF100 & SA1020 RF100 near field probe set Essential tool for the location of emission sources and identification of emission frequencies. SA1020 Pre-amplifier 20dB gain, flat characteristic from 9KHz to over 1GHz. Internal PP3 battery provides 30 hour run time. IEC61000-4-6 Compact Immunity Test System Model RFIC46 CIT-10 Includes: Function generator Signal Generator RF Millivoltmeter RF power amplifier EUT monitoring Feedback monitoring Wide range of optional ‘Versatile’ and ‘Enhanced’ CDNs available •PC Controlled via USB •Windows software included •100KHz – 300MHz (Exceeds requirements of the standard •25W power amplifier… more than enough for most applications •Totally integrated system… very quick and easy to use. CLIENTS Combined Low cost Immunity and EmissioNs Test Systems. CLIENTS System shown will provide automated measurements of emissions and RFI testing up to 2GHz. The LETIS (Laplace EMC Test Integration System) provides all necessary interconnections and switching under software control. Any standard PC SA1002 or SA3000 Emissions analyser RF2000 Immunity controller RF1100 30-1000MHz P.A. LETIS System integrator RF1200 0.8-2GHz P.A. RF Power Amplifiers Power amps A range of RF power amplifers for use with test cells RF1100 RF1170 RF1200 RF1240 RF1300 25W 30MHz to 1GHz 70W 30MHz to 1GHz 12W, 0.8GHz to 2GHz 40W, 0.8GHz to 2GHz 10W, 0.8GHz to 3GHz These amplifiers will provide well in excess of the required fields for IEC61000-4-3 industrial standards inside the LaplaCells Immunity test controllers Synthesiser RF1000, 30MHz – 1GHz RF2000, 30MHz – 2.2GHz RF3000, 30MHz – 3GHz Functions: •Signal generation and control •Field strength level control •EUT monitoring •Windows interface via USB •Flexible test setup •Full recording and display of results •Serial interface for remote sensor These controllers will provide all control and interface requirements for sophisticated immunity testing to IEC61000-4-3. LETIS Laplace EMC Test Integration System. Letis RS232 LETIS acts as a PC controlled switching unit to automatically route the signals between the cell, the power amplifiers and the system controller. Avoids mistakes, saves time and allows long term unattended operation. Control USB To PC To Cell USB RF Laplace Instruments Ltd EMISSIONS Auto 1 2 Power IMMUNITY Range 1 RF1100 connections To RF2000 Manual Range select To emissions analyser LETIS - Laplace EMC Test Integration System RF connection to cell Range 2 RF1200 connections Made in UK EMC analysers and software SA1000-b High performance EMC analysers……. SA1002…………9KHz – 1GHz SA3000…………9KHz – 3GHz Compliant detectors (Pk, QP and Average) Pre-loaded limits in software. All results in Windows environment. Easy to use…. Serial interface to any PC. Input connects to any Laplace antenna or transducer. See also the RF910 and RF915 pre-selectors. Conducted Radiated Pre-selector Antennas LISNs Test cell Voltage probes Reference sources RF Immunity test RFI test-b IEC61000-4-3 requires EUT to be immersed in strong modulated RF fields over the range 80MHz – 1GHz. The specified techniques are fully incorporated into The Laplace test system comprising a LaplaCell, system controller and power amplifier. See CLIENTS for total automated solutions. Note that these systems work equally well with test chambers (FAC or SAC or stirred mode). EUT Feedback USB Any standard PC RF1000 or RF2000 or RF3000 RF1100 and/or RF1200 or RF1300 RF Power RF level feedback About Laplace…. Founded in 1988 Laplace Specialises in EMC test equipment NOT linked to any other company Customer base worldwide Global distributor network Over 2000 EMC test systems in operation Over 50 LaplaCell systems sold. All main products and software developed in-house We ALWAYS support all our customers direct… regardless of age of system (and all free of charge!) Continuous development program… new hardware and software to match developments in standards Join the experts!