laplace04a__ - Laplace Instruments Ltd

advertisement
Home
EMC Compliance
systems
Emissions
EN series
Def Stan
FCC
As/Nz
and
EMC Pre-Compliance
systems
Immunity
IEC61000-4-series
and
RF monitors
and meters
Harmonics & Flicker
Safety at work
IEC61000-3-2
IEC61000-3-3
ICNIRP
All from the Experts at Laplace Instruments Ltd
Selector
Make emissions measurements to check emission compliance?
Test for susceptibility/immunity?
Or both?
Test for Harmonics & Flicker compliance?
Looking for ancillaries such as reference sources, antennas, LISNs etc…..?
See the overview and selector chart
EMC Compliance Testing – the essential guide
Emissions
RFG- core
system
RF100 probes
IEC61000-4-3
Radiated RF
IEC61000-4-2,4,5,11 IEC61000-4-6
LF effects
Conducted RF
SA1020 pre-amp
RF1000 (1GHz)
or RF2000 (2GHz)
or RF3000 (3GHz)
Synthesiser
Radiated
All EMC emission
standards
Appliance?
EN55014
LISN or PLIP
RF Absorbing
clamp
Luminaire?
EN55015
If emissions
Broadband?
EUT size………
Large and small
OATS
Anechoic
chamber
ERS Emissions
Reference Sources
LETIS
or
RFIC-46
RF200
RF230
antenna
Small?
Test cell Lc300/2 or Lc600
30MHz – 3GHz
Filtered
feeds
CDNs
AC1000 clean
Power source
ECOMPACT4
Integrated test
system
Information
CDNs
Laplace product
ESD
Incl PC software
Clamps
Camera
& lighting
Loops
Anechoic
chamber
IEC61000-3-2
IEC61000-3-3
AC2000 analyser
RF11xx, RF12xx or RF13xx
Power Amplifiers
RF300 large
Loop antenna
All other EMC
standards
RF200, RF230 or CTS011
miniature antenna
RF600 and RF700
Ambient filters
Harmonics & Flicker
Routemap
SA1000 (1GHz) or
SA3000 (3GHz)
analyser
Conducted
RF800 or RF910
or RF915
Pre-selector
Susceptibility (immunity)
Key
Incl. in CLIENTS
LETIS
RFP-04CE Field probe
+fibre link option
HARMONICS & FLICKER
H&F
Compliant with:
IEC61000-3-2
IEC61000-3-3
AC2000A
AC1000A
Clean power source.
Provides up to 1kW (4A) of pure sine
mains power.
Output harmonic content: <0.1% THD
Harmonic & Flicker analyser.
Features:
Automatic testing
Automatic calculation of ‘variable’ limits
Self contained instrument
PC interface included
Emissions…………
Emission selector
Emissions analyser
Radiated – test cell
Radiated – Antenna
Radiated – Large Loop Antenna
Radiated – Reference sources
Radiated – Pre-amplifier
Radiated – Near field probes
or
?
Conducted
Conducted emissions
Conducted selector
Analyser and software
LISNs
Voltage probes
EMC analysers and software
SA1000-a
High performance EMC analysers…….
SA1002…………9KHz – 1GHz
SA3000…………9KHz – 3GHz
Compliant detectors (Pk, QP and Average)
Pre-loaded limits in software.
All results in Windows environment.
Easy to use…. USB interface to any PC
Input connects to any Laplace antenna or transducer.
See also the RF910 and RF915 pre-selectors.
Conducted
Pre-selector
Radiated
Antennas
LISNs
Test Cell
Voltage probes
Reference sources
Test cells
Cells
It does not get any easier
than this………..
* Quick
* Compact
* Convenient
Radiated Emissions to 3GHz
Radiated Immunity to 3GHz
Select
Emissions
or
Immunity
Two sizes:…….
Lc300/2: up to 30cm cube EUT, benchtop model
Lc600:
up to 60cm cube EUT, floor standing
Both provide IEC61000-4-3 testing to over 10V/m
More details……
Access door open
to EUT area
Lc300/2-outer
System configured with:
•SA1000 emissions analyser
•RF2000 synthesiser
•RF1100 power amplifier
•LETIS
•RF1200 power amplifier
More details……
Lc300/2
Lc300/2
Lc300/2-filter
Filter connection plate to
External services
Access door open to internal filter connections.
Aperture (hidden) provides access to EUT volume
More details……
Advantages of test cells
•Eliminate ambient
•Known calibration
•Compact size
•Ease of use
•Located in your own lab.
•Convenience
•Not dependant on the weather!
Advantages specific to LaplaCell
Cellnotes
•Smallest size
•Better field uniformity
GTEM field
- poor uniformity
LaplaCell field
- far better uniformity
•Impedance matched for better results
•Free space impedance is 377ohm (Ideal)
•GTEM cells are 50ohm systems
•Laplacell features impedance conversion to 200ohm
•Much closer to ideal
•Complies with IEC61000-4-20
•Latest standard for the calibration of cells
•Built-in field sensor
•Save cost and complexity
Test chamber option
Integrated system for immunity testing to IEC61000-4-3 in test chamber
RF200 and
RF230 antennas
Test chamber
Field sensor (RFP-04CE)
With RS232 fibre optic interface (PCLK)
Chamber
Optional EUT
monitoring
Fibre optic cable
(FOLK)
EUT
Antenna
Synthesiser/
signal
genny
Power
amplifier
RF1000, RF2000 or RF3000 with
–RH option (External sensor)
RF11xx
RF12xx
or
RF1300
System
controller
System
software
Switch
Unit
LETIS
Pre-selector units
RF910
RF910 and RF915
As specified by CISPR16
and recommended for conducted
emission measurements if the EUT
produces broadband noise.
RF1000 or RF2000
These pre-selectors effectively pre-filter
the incoming signal such that the
analyser input is not overloaded
by broadband energy.
Not required if EUT produces
narrowband noise.
RF910 covers band B (150KHz – 30MHz)
RF915 covers bands A and B (9KHz – 30MHz)
Photo shows RF910 below SA1000 and PC
Emissions Reference Sources
ERS
These sources can be used to simply check
an established site prior to measurements,
or
To calibrate an unknown site.
Note that the dominant source of measurement
uncertainty for radiated emissions is the test site!
ERS
1GHz reference source
EMC3.5
3.5GHz reference source.
Fully traceable to NPL
Extremely compact
Only 12 x 7 x 14cm
2MHz spacing
Provides auto site
calibration when used
with SA1002 or
SA3000
10 or 50MHz spacing
Remote control option
Antennas
A range of antennas to
cover most requirements.
Antennas
ARA Active receive antenna
Compact, but same sensitivity as
larger antenna
RF300 Large loop antenna
(Van Leen Loop)
To CISPR15
CTS011
RF200
Broadband antenna
30MHz – 1GHz
Standard EMC antenna
For use on OATS or in
test chambers
Very small! About the size of your hand.
For use in confined spaces
RF meters and detectors
TDM-200
RF power density meter.
Trifield
Internal antenna
Ideal for RF signal strength field surveys.
0.5MHz to 3GHz
TBM-100 Broadband meter
An Electric field meter, Gaussmeter and
RF field strength meter all in one small unit.
Monitor and measure the field from AC power
lines, video displays, ovens, LANs and mobile
phones
Gaussmeter: 40Hz –500Hz
Electric field meter: 40Hz – 100KHz
RF field meter: 100KHz – 2.5GHz
T-MA-P
Personal RF hazard warning detector
Provides an audible warning if the RF field is
close to the ICNIRP recommended limits
Essential for all who work close to RF
transmittersand cell base stations
LISNs and Voltage Probes
LISN
LISN - Line Impedance Stabilisation Network
Commercial range complies with CISPR16
Def Stan, Mil Spec and CISPR25 versions also available
Up to 4 lines
Up to 100A/phase
Commercial range includes transient limiters
PLIP Voltage probe
As specified by CISPR16
For use when LISN is not appropriate.
Includes opto-isolation and high voltage,
fused connecting clips
Immunity testing
Immunity selector
IEC61000-4-2
ESD
ONYX16 simulator
IEC61000-4-3
Radiated RF
LaplaCell and ancillaries
IEC61000-4-4
EFT
ECOMPACT4
IEC61000-4-5
Surge
ECOMPACT4
IEC61000-4-6
Conducted RF
RFIC46 system + CDNs
IEC61000-4-8
Power Mag. Field
ECOMPACT4 (option)
IEC61000-4-9
Pulsed Mag. Field
ECOMPACT4 (option)
IEC61000-4-11
Dips and Interrupts
ECOMPACT4
LaplaCell
systems
RFIC
systems
ECOMPACT4
Standard system
RF Immunity test
RFI test-a
IEC61000-4-3 requires EUT to be
immersed in strong modulated RF fields
over the range 80MHz – 1GHz, or higher!
The specified techniques are fully incorporated into
The Laplace test system comprising a LaplaCell,
system controller and power amplifier.
See CLIENTS for total automated solutions.
Note that these systems work equally well with test
chambers (FAC or SAC or stirred mode).
EUT Feedback
USB
Any standard PC
RF1000, RF2000 or RF3000
RF1100 and/or RF1200 or RF1300
RF Power
RF level feedback
Pre-amp & near field probes
RF100 & SA1020
RF100 near field probe set
Essential tool for the location of emission
sources and identification of emission
frequencies.
SA1020 Pre-amplifier
20dB gain, flat characteristic from
9KHz to over 1GHz.
Internal PP3 battery provides 30
hour run time.
IEC61000-4-6
Compact Immunity
Test System
Model RFIC46
CIT-10
Includes:
Function generator
Signal Generator
RF Millivoltmeter
RF power amplifier
EUT monitoring
Feedback monitoring
Wide range of
optional ‘Versatile’ and ‘Enhanced’
CDNs
available
•PC Controlled via USB
•Windows software included
•100KHz – 300MHz (Exceeds requirements of
the standard
•25W power amplifier… more than enough for
most applications
•Totally integrated system… very quick
and easy to use.
CLIENTS
Combined Low cost Immunity and EmissioNs Test Systems.
CLIENTS
System shown will provide automated
measurements of emissions and
RFI testing up to 2GHz.
The LETIS (Laplace EMC Test Integration System)
provides all necessary interconnections and
switching under software control.
Any standard PC
SA1002
or
SA3000
Emissions analyser
RF2000
Immunity controller
RF1100
30-1000MHz P.A.
LETIS
System integrator
RF1200
0.8-2GHz P.A.
RF Power Amplifiers
Power amps
A range of RF power amplifers
for use with test cells
RF1100
RF1170
RF1200
RF1240
RF1300
25W 30MHz to 1GHz
70W 30MHz to 1GHz
12W, 0.8GHz to 2GHz
40W, 0.8GHz to 2GHz
10W, 0.8GHz to 3GHz
These amplifiers will provide well
in excess of the required fields
for IEC61000-4-3 industrial standards
inside the LaplaCells
Immunity test controllers
Synthesiser
RF1000, 30MHz – 1GHz
RF2000, 30MHz – 2.2GHz
RF3000, 30MHz – 3GHz
Functions:
•Signal generation and control
•Field strength level control
•EUT monitoring
•Windows interface via USB
•Flexible test setup
•Full recording and display of results
•Serial interface for remote sensor
These controllers will provide all
control and interface requirements
for sophisticated immunity testing
to IEC61000-4-3.
LETIS
Laplace EMC Test Integration System.
Letis
RS232
LETIS acts as a PC controlled
switching unit to automatically
route the signals between the cell,
the power amplifiers and the
system controller.
Avoids mistakes, saves time and
allows long term unattended
operation.
Control
USB
To PC
To Cell
USB
RF
Laplace Instruments Ltd
EMISSIONS
Auto
1
2
Power
IMMUNITY
Range 1
RF1100 connections
To RF2000
Manual
Range
select
To emissions
analyser
LETIS - Laplace EMC Test Integration System
RF connection
to cell
Range 2
RF1200 connections
Made in UK
EMC analysers and software
SA1000-b
High performance EMC analysers…….
SA1002…………9KHz – 1GHz
SA3000…………9KHz – 3GHz
Compliant detectors (Pk, QP and Average)
Pre-loaded limits in software.
All results in Windows environment.
Easy to use…. Serial interface to any PC.
Input connects to any Laplace antenna or transducer.
See also the RF910 and RF915 pre-selectors.
Conducted
Radiated
Pre-selector
Antennas
LISNs
Test cell
Voltage probes
Reference sources
RF Immunity test
RFI test-b
IEC61000-4-3 requires EUT to be
immersed in strong modulated RF fields
over the range 80MHz – 1GHz.
The specified techniques are fully incorporated into
The Laplace test system comprising a LaplaCell,
system controller and power amplifier.
See CLIENTS for total automated solutions.
Note that these systems work equally well with test
chambers (FAC or SAC or stirred mode).
EUT Feedback
USB
Any standard PC
RF1000 or RF2000 or RF3000
RF1100 and/or RF1200 or RF1300
RF Power
RF level feedback
About Laplace….
Founded in 1988
Laplace
Specialises in EMC test equipment
NOT linked to any other company
Customer base worldwide
Global distributor network
Over 2000 EMC test systems in operation
Over 50 LaplaCell systems sold.
All main products and software developed
in-house
We ALWAYS support all our customers direct…
regardless of age of system (and all free of
charge!)
Continuous development program… new
hardware and software to match developments
in standards
Join the experts!
Download