The Evaporcool System is a proprietary
evaporative cooling system that works
with virtually any air-cooled HVAC unit.
The EvaporCool System
•
•
•
•
•
•
•
•
•
Reduces Energy Usage
Reduces Demand Charges
Reduces Overall Maintenance
Increases Tonnage Capability
Reduces Head Pressure
Increases System Reliability
Protects Coils from Debris and Damage
Extends the Life of HVAC equipment
Minimal Maintenance. No Moving Parts!
The Evaporcool System
uses multiple proprietary
technologies.
A Simple Principle
Hot outside air is cooled as it passes
through the EZ-Frame, before it reaches
the condenser coils.
This allows the system to operate as
though it were cooler outside than it
actually is.
On recent 100 degree days (73 wet
bulb), in a humid Southeastern U.S.
climate, the leaving air temperature of
the EvaporCool system entering the
condenser is 79.2 degrees!
EZ-Frame
The EZ-Frame™ framing system (patentpending) provides a unique mechanism
for protecting condensing coils, and
creates an environment in which air
temperature is lowered as it enters the air
conditioning unit.
The system is designed so that absolutely
no water transfers to the condenser coils.
Panels are attached by rare earth super
magnets for ease of unit access.
Removable Panel Screen
The easy to remove screens offer easy
access for cleaning and replacing media.
Magnets
SmartSpray
TM
The SmartSprayTM control box is the brain
of the EvaporcoolTM System. It monitors
the external environment and the HVAC
equipment in order to determine the
optimal amount of water to evaporate
into the air.
It also eliminates the need for a
recirculation system for excess water.
Now available with Performance
Monitoring System with BACnet
interface
Microprocessor
Sensors
Performance Monitoring System
• Remote Monitoring & Alerting
• Cloud-Based Monitoring & Control
• Sensor Data Logging and Analysis
• Real-time Failure Mode Detection
• Energy Savings Dashboard
• Service Dashboard Toolbox
Performance Sensors:
• Compressor Current
• (Wattage Calculated)
• Water Pressure
• Condenser Liquid Line Temp
• Outside Ambient Temp
• Relative Humidity
• Entering Condenser Air Temp
Optional Sensors:
• Water Flow
• True Power
Sample Installations
Air-Cooled Chillers
Houston, TX
Sample Installations
RTU
Atlanta, GA
Sample Installations
RTU - High Efficiency DX-Style
El Dorado Hills, CA
Sample Installations
Remote Condensing Units
Horizontal EZ-Frame Installation
Memphis, TN
Sample Installations
Refrigeration Units
El Dorado Hills, CA
Customer Case Studies
The following case studies demonstrate energy savings.
TESTING PROCEDURES
All data is sorted according to the Cooling Degree Days…
Definition: COOLING DEGREE DAY (“CDD”)
A unit used to relate the day's temperature to the energy demands of air conditioning. One cooling
degree day occurs for each degree the daily mean temperature is above 65° Fahrenheit.
Examples:
Min
Max
Mean
Day 1
60°
80°
70°
- 65°
Day 2
70°
90°
80°
- 65°
Day 3
75°
105°
90°
- 65°
CDD
5
15
25
TESTING PROCEDURES
Step 1: Baseline Testing
Prior to installation of the Evaporcool System, a data logger* is installed on the subject HVAC
equipment to collect all applicable real-time energy consumption and unit performance information.
The duration of this test depends upon the weather at the location, but will typically last at least 2-3
weeks.
Step 2: Installation of the Evaporcool System
Step 3: Comparison Testing
After application of the Evaporcool System, real-time energy consumption and unit performance data
is collected. The duration of this test typically mirrors the duration of the baseline testing, but is also
highly dependent on the weather.
Step 4: Data Analysis
Once complete, all data is collected and analyzed by our in-house engineering department. We sort
all data by Cooling Degree Day, as provided by the National Oceanic and Atmospheric Administration.
The average kWh consumed during the baseline testing period is then compared that consumed
after installation of the Evaporcool System.
*All data was collected using either an Amprobe Data Logger (Model DM-II Pro) or a Satec Event & Data Logger (Model #EDL172XR or EDL174).
CASE STUDY #1
Unit Description:
Location:
Customer:
Date of Testing:
50 Ton Air Cooled Chiller
Marysville, CA
Beale Air Force Base
Summer of 2013
CASE STUDY #1
Summary of Results
Savings = 14,000 kWh
% kWh Savings = 22% kWh
% kW Demand Savings 20%
CASE STUDY #2
Unit Description:
Location:
Customer:
Date of Testing:
40 Ton Packaged Condensing Unit
Cypress, TX (Houston Area)
Large Telecom Company
Summer of 2008
CASE STUDY #2
Summary of Results
500
450
425
393
400
339
350
kWh
300
308
283
250
239
338
319
332
250
200
150
100
50
0
14
16
17
19
20
Cooling Degree Day (CDD)
Without EvaporcoolTM
21
With EvaporcoolTM
% Savings
14
16
17
19
20
21
22
19.5%
29.5%
31.1%
21.5%
19.3%
20.3%
19.1%
402
395
363
352
CDD
22
Percent savings on case study is based on entire unit including condenser fans.
CASE STUDY #3
Unit Description:
Location:
Customer:
Date of Testing:
20 Ton Carrier 50EWQ24
Sylmar, CA
Verizon Wired
Summer of 2012
CASE STUDY #3
Summary of Results
Summary Report
Savings = 16585.6 kWh
% Savings = 22.54% kWh
Demand Savings = 5.6 kW
Saving/ Ton = 0.28 kWh/ton
% Demand Savings = 20.28%
14000
12,528.24
12000
10,611.50
9987.2597
9,305.90
KWH
10000
8000
7,055.82 7,083.59
8459.2754
7,583.61
7418.4745
6,361.35
6045.5031
5624.7538
5646.8985
6000
4,277.94
3410.2838
3410.2838
2,527.87
2015.1677
4000
4,222.38
3365.9944
1,583.39
2000
0
1262.2479
444.46
354.3152
106
101
96
91
86
81
76
71
Bin Temperature ⁰F
Without Evaporcool™
With Evaporcool™
66
61
56
51
Additional Savings
The previous case studies only demonstrate savings from kWh reduction
… but the Evaporcool System provides many additional benefits…
Additional financial benefits include:
1. Peak Demand Reduction;
2. Maintenance Savings;
3. Reduced Equipment Failure;
4. Increased Equipment Life;
5. Available Tax Benefits; or
6. Potential for Utility Rebates.
Product Testing
In 2008, the Evaporcool System was tested at
Underwriters Laboratories Inc.’s 16,000 square foot
state-of-the-art testing facility in Plano, TX.
The testing was performed on a 7.5 ton DX style Air
Conditioning System at 95oF, 98oF and 105oF.
The results verified performance
REDUCED MAINTENANCE
Cleaner coils means more efficient operation.
“A … dirty condenser coil can
increase compressor energy
consumption by 30%.”
- Federal Emergency Management Program Fact Sheet
“If the coil is dirty …. this raises
your electricity cost for air
conditioning and may shorten the
life of the outdoor condensing
unit.”
- Saturn Research Management
REDUCED MAINTENANCE
The Evaporcool System protects coils from dirt and
debris, so your coils stay clean longer.
BEFORE
AFTER
REDUCED MAINTENANCE
Properly cleaning condenser coils requires:
•
•
•
•
Hours of labor spent taking equipment apart and pressure washing coils.
Taking the unit “off-line” for this period.
Using caustic chemicals on your facilities and handling chemical runoff.
Immediately after cleaning, the unit begins to collect dirt once again.
With Evaporcool®:
• Coils are professionally cleaned upon installation, and immediately sealed
off from outside air.
• Dirt and debris are prevented from entering the system.
• Our customers can go years without cleaning coils.
REDUCED MAINTENANCE
Evaporcool® Maintenance is fast & easy…
Maintenance Guide
Maintenance Guide
Page 1
Page 2
Routine Maintenance:
At the end of the Cooling Season:
Step 1: Brush debris off screen
and media pad. If dirty, brush
or rinse with hose.
Step 1: Unplug quick-connect
fittings.
Step 2: Clear system with
compressed air.
DATA CENTER TESTIMONIAL
Unit Description:
Location:
Customer:
Facility Use:
Date of Install:
5 Liebert Units (70 Tons)
El Dorado Hills, CA
Large Health Insurance Provider
Data Center
Summer of 2009
DATA CENTER TESTIMONIAL
The Problem:
Critical data center with insufficient HVAC capacity.
The Solution:
Mechanical contractor installed Evaporcool Systems.
The Results:
“…our LAN room has had a 7 to 8 degree lower temperature.”
“…there was a calculated 16 ton addition to our cooling capacity
to our LAN room….” – Facility Engineer
WATER
The Evaporcool System uses the precise amount of
water needed to optimize cooling… and no more.
Minimal Water Use
50 Ton Rooftop Unit
(Atlanta, GA)
Max Water Consumption:
Note that these water flow consumption rates
are in gallons per HOUR, not GPM and are the
average of water consumption over a year.
Water Pressure
40 PSI
60 PSI
4 gallons / hour
5 gallons / hour
Water Conservation
•
The National Renewable Energy Lab (NREL) reports: “U.S. electricity production
consumes over 20 gallons of water per KWH created.
•
Other studies confirm this water usage and state that depending upon the power
plant type, the water usage can range from 10 gallons to 25 gallons of water
consumed per KWH created.
•
The EvaporCool system uses approximately 1.9 gallons of water for each KWH
saved. This saves approximately 90% of water usage while saving electricity
•
Based on national averages, on a 75 ton hvac unit, the EvaporCool system will use
$78 of water in a year, while saving over $7,000 annually in electricity.
•
By reducing electricity demand and consumption, Evaporative Cooling actually
SAVES water on a global scale!”
Kinetico Water Treatment
Kinetico salt/resin ion exhange water treatment
used on many “hard” water sites. Removes the
minerals (calcium and magnesium primarily)
from the water stream. Requires occasional
addition of salt to the tank.
HydroFlow Water Treatment
Uses advanced water treatment technology, the Evaporcool System
operates best in soft water hardness environments.
How Hydropath Technology Works
The difference between Hydropath Technology and other physical water
conditioning technologies is the induced signal and its ability to treat an
entire system continuously. HyrdroFLOW’s water conditioners induce an
electric signal of ±150 kHz into any water pipe on which they are installed
(copper or PVC). The electrical induction is performed by a special transducer
connected to a ring of ferrites. Just as an electrical wire carries a current from
point A to point B, the water inside the pipe acts as a conductor and carries
the induced electric signal throughout the entire water system. The oscillating
sine waves of the induced AC signal cause the positively and negativelycharged ions to form suspended clusters in the water, preventing them from
attaching to surfaces. These clusters “clump” together into a fine, white
powder that collects on the Evaporcool media in small quantities (measured
in parts per million) that occasionally need hosing off the media when any
dust in the air is hosed off. Testing shows that compared to other non
chemical electronic water treatment technologies, Hydropath Technology is
30,000 times more powerful.
HydroFlow Water Treatment
HydroFlowTM System:
• No Salts. No Chemicals. No Magnetic Coils.
• Unit transmits a unique radio frequency
signal that effectively breaks up existing
limescale and prevents future buildup
protecting the entire plumbing system.
• The HydroFlow unit simply clips to the pipe,
is plugged into an outlet and is switched on.
There is no plumbing or electric work
required.
Optional Booster Pump
Booster pump needed if
water pressure at HVAC
unit is less than 60 PSI.
Evaporcool is one of the few products that reduces the energy usage of air cooled HVAC equipment.
Using evaporative cooling to precool the entering condenser air has been around for decades. There
are reasons that Evaporcool is the market leader in this market.
Some system details of the Evaporcool system include:
1. Dramatically reduces the entering condenser air temperature. These systems have had a U.L. testing analysis and
thousands of systems operating successfully. On a humid, 95db/78wb outside design day, the Evaporcool unit will
cool this air to approximately 82 degrees db. Depending upon unit type, this reduces the energy usage by 20-22%
or more.
2. KW demand is reduced
3. Due to the Evaporcool filter media, dirt in the air is prevented from reaching the condenser coil. This saves on
annual condenser coil cleaning labor. It also increases efficiency.
4. Since the units run at a lower condensing temperature, repairs are minimized. The reason air cooled units
typically require considerably more repairs in the heat of the summer is because of the high condensing
temperatures and pressures that normally are experienced.
5. With the reduced condensing temperatures and pressures of the Evaporcool system, equipment life can be
extended.
6. Typical payback periods, only counting the energy savings, are approximately 2 to 4 years. Rebates and
incentives are available in many locations.
7. This is one of the few technologies that increases energy efficiency but at the same time does not negatively
affect the room temperature.
8. Cooling capacity increased approx. 8-12 percent.
The design advantages of the Evaporcool system include:
1. Evaporcool does not spray water onto the condenser coils. It sprays water within the Evaporcool
casing causing the Evaporcool filter media to remain saturated. This cools the air and prevents
moisture from collecting on the condenser coil. In addition, even though no water is sprayed on the
condenser coil, the water is filtered and treated with a water softening system.
2. The condenser coils are filtered from dirt in the air that has to be cleaned regularly and causes
energy inefficiency.
3. The air pressure drop through the media pad is very low (less than 1/10 of an inch) by design
4. Units are attached to the A/C units with rare earth super magnets and quick attach couplings. This
allows the Evaporcool units to be quickly removed if necessary for repairs and maintenance. System is
totally non-invasive.
5. The SmartSpray computerized controller sprays the precise amount of water to minimize water
usage and prevent water draining on the roof. No recirculation system or drain system is required
6. Some of the Evaporcool clients include AT&T (many sites), Verizon, Hewlett Packard,
the University of Tennessee and many other high profile clients.
The website is www.evaporcool.com.
®