ProficyiFIX58WhatsNewCustomerPresentation

advertisement
Proficy HMI/SCADA – iFIX
5.8
What’s
New?
GE Intelligent
Platforms
Our
Vision
Our Vision
Connecting the dots….
GE Intelligent Platforms
gets you Connected
power and
digital tools
at the source
Connecte
d
Machines
islands of
information
aggregated
Connecte
d
Data
analytics in
real-time
Connecte
d
Insights
Information
finds you,
mobile access,
collaboration
Connecte
d
People
Connecting the dots to deliver seamless “insight to action”
3
iFIX 5.8
Nov. 2013
iFIX v5.8 enables connecting the
dots
Information finds you,
islands of
information
aggregated
analytics in
real-time
mobile access,
collaboration
Connecte
d
Data
Connecte
d
Insights
Connecte
d
People
Mobile
Desktop/
Web
S2SD
iFIX 5.8
SCADA
Buffer
Workflow
Unified
Webspace
4
iFIX 5.8
Nov. 2013
®
Proficy
Proficy® Continuous Improvement
HMI/SCADA - iFIX The road to Version 5.8
5
Proficy HMI/SCADA – iFIX
5.8 At a Glance
Main Customer Benefits
Reliability & Security
Product Core enhancements that deliver:
Failover Enhancements
•
•
•
•
Enhanced Performance & Scalability
Greater Reliability & Security
RtOI Ready
Newer OS Support
Enhanced Performance & Scalability
Dynamic Resolution Support for iFIX
Graphics
• Support for deploying iFIX Graphics on Wide
Screen monitors, LCD TVs and different aspect
ratio Screens
• Ability to move iFIX graphics from one resolution
to another
Efficient Rendering of iFIX Run time
Graphics
• Reduces the CPU usage of iFIX Graphics
• Reduce CPU usage of Background Graphics
• Speed of Alarm Distribution on Failover
• Maintenance Mode improvements
• Support for I/O Driver Access timeout on
Failover
Security Enhancements
• Encrypted Authentication key for iFIX Network
• Support for 256-bit Encryption for Webspace
Sessions
• Sandboxing feature for Webspace sessions
RtOI Ready
•
•
SCADA publishing to the Model
Support for Read/Write to iFIX from
Workflow
Newer OS Support
®
Proficy
New Operating Systems
iFIX 5.8 Support
7
New Operating Systems Support
*
*
* Currently iFIX will not support Environment Protection for iFIX Graphics in Runtime
while running on Windows 8 and Server 2012.
8
iFIX 5.8
Nov. 2013
®
Proficy
Proficy® Enhanced Performance
HMI/SCADA - iFIX & Scalability
Proficy HMI/SCADA – iFIX
Dynamic Resolution support
Low form factors/resolutions
Non-Standard
Aspect Ratios
Web based Rendering
Wide Screen
Displays
High Definition
Large Displays/TVs
10
iFIX 5.8
Nov. 2013
Proficy HMI/SCADA – iFIX
Efficient Graphic Rendering
Individual Graphic Refresh
Efficient Active Graphic Updates
Multi Graphic
Refresh
Multi Monitor
Graphic Refresh
Efficient
Background/Non Focus
Graphic Updates
CPU Usage per
Workspace Instance
11
iFIX 5.8
Nov. 2013
®
Proficy
Proficy® 5.8 Customer Benefits
HMI/SCADA - iFIX Reliability & Security
Proficy HMI/SCADA – iFIX
Failover Enhancements
Alarm Distribution Performance
on Failover
No lag on New Alarm notifications
Primary
Backup
Maintenance Mode Cross Sync
User Interaction synchronization from Backup
to Primary before exiting Maintenance Mode
Database Manager will always connect to
Primary SCADA
I/O Driver initiation on Failover
Maintain Alarm statuses on Failover
through I/O driver warm start on
new Active SCADA
13
iFIX 5.8
Nov. 2013
Proficy HMI/SCADA – iFIX
Security Enhancements
Password Encryption for
Trusted Client-Server networks
• 256 bit AES encryption Support
• Sandboxing support with capability to
whitelist applications for Webspace
sessions to prevent unauthorized
access
14
iFIX 5.8
Nov. 2013
®
Proficy
Proficy®
5.8 Embedded
HMI/SCADA - iFIX
15
Proficy HMI/SCADA – iFIX
Embedded
iFIX 5.8 Dynamic Resolution support
allows for cleaner deployments
Powered by Historian for SCADA
S2SD
•
•
1500 tags/ 60 day Trend storage
Trend storage to Historian distributor
SCADA
Buffer
7
supported
16
iFIX 5.8
Nov. 2013
®
Proficy
Proficy®
RtOI Ready
HMI/SCADA - iFIX
What is RtOI?
RtOI is the experience of anticipating operational
situations and being able to take appropriate
Action - Anywhere, Anytime.
AND
It is enabled by integrating & enhancing the existing tools that
users have:
with new capabilities
like
KPI
Notes
Cause
Tasks
Glance
18
iFIX 5.8
Nov. 2013
Drive to Actionable Knowledge
Where Your Operations Need To Be!
Information
Anytime, Anywhere
•
•
•
•
•
Mobility
Structured and in Context
Geo-Aware
Operational Performance
Integrated Detection
Intelligence In Real Time
•
•
•
•
•
Understanding Health
Alarm by Knowledge
Preventative Detection
System Does Mining
Production Relationships
Information Flow
(The Transparent Organization)
•
•
•
•
Fast and Agile
Collaboration
Work Tasks Management
Business to Operations
RtOI
Optimize and Improve
• Analysis Dashboards
• Historical Queries
• Process Control and
Optimization
19
iFIX 5.8
Nov. 2013
From Data Everywhere to …
Actionable Knowledge Anywhere Anytime
•
•
•
•
•
•
Proficy Agent
•
•
•
•
•
Connectivity
Provisioning
Multi-tenancy
Exception based
Cloud to Site service
delivery
Mobile KPI
Context (Org/Relationships)
Role Based
Proximity Awareness
Mobility
Integrated Analytics
Collaboration (P2P/M2M)
Advanced Alarming
Mobile Notes
HHA
HA
T em perature
L Dev
S Dev
Setpoint
S Dev
L Dev
LA
LLA
Time
High High Alarm
High Alarm
Low Alarm
Low Low Alarm
Small Deviation
Large Deviation
Data Acquisition & Control
Workforce Enablement
Data Management
®
Proficy
RtOI – iFIX Historian for SCADA
Data Management Starts the Journey
21
Proficy Historian for SCADA v5.5
The Proficy Historian Family
What is
your need?
On Node basic
trending (ships
with SCADA)
Trending plus
permanence /
redundancy
Proficy SCADA
aggregation
Centralized
Storage (off
node,
aggregated
data)
Recommended Historian Edition
SCADA Buffer
2500 pt /200 day
trend buffer
S2S Distributor
On Node
Permanent
History
Storage
(varies by iFIX tag
counts)
Proficy Historian
Standard edition
Proficy Historian
Enterprise
edition
Incremental capabilities:
• Permanent storage
• Collector redundancy
• SCADA redundancy
support
• OPC HDA
• Multiple data stores
Incremental capabilities:
• Multi-node/site aggregation
• Historian High Availability
• Calculation collector
• Server to Server
• OPC A&E
• Additional data stores
Historian HD
(hosted by GE IP)
What it Does:
• Long-term storage
• Massive datasets
• Cross functional
integration & querying
• Fleet analytics
• Data thinning
• Cloud backup
23
iFIX 5.8
Nov. 2013
SCADA Buffer – What is it?
The Unified Trending Engine in Proficy Historian for SCADA
SCADA Buffer is included with iFIX
• 2500 Buffered tags for real-time
trending
• 200 Day circular buffer
• Standard collectors
• Historian is the engine driving
advanced SCADA capabilities
•
SCADA
Buffer
+
Historical
Store
Historian Engine
DGR, iSCADA Mobility, etc
PH4S adds on-node permanent
Tags
• Long term storage for KPIs,
compliance, etc.
• Same functionality as normal
24
iFIX 5.8
Proficy Historian tags
Nov. 2013
Server To Server Distributor
PH
iFIX
PH4S
SCADA Buffer
Historian
Tags
S2SD
On Node Only
iFIX
PH4S
SCADA Buffer
S2SD
On Node Only
iFIX
PH4S
SCADA Buffer
S2SD
• Enables “one click” publishing of
data to central historian from local
source
• Used to either historize centrally,
OR to aggregate historized
content for analysis and reporting
• Functionality similar to Server to
Server Collector (centrally
administered), w/o calcs
• Available for use in customercreated apps via API
On Node Only
25
iFIX 5.8
Nov. 2013
What do we get with Proficy iFIX
iFIX Tag Counts
Trend Buffer (200 Days)
Permanent Storage
75
2500 tags
100 tags
150
2500 tags
100 tags
300
2500 tags
100 tags
900
2500 tags
500 tags
Unlimited
2500 tags
1000 tags
• 2 CALs included for Admin and OLEDB
• No options to add more permanent tags or CALs
26
iFIX 5.8
Nov. 2013
Why Proficy Historian for SCADA?
Advantages over traditional Data Loggers
• Simple set-up and configuration – single install/one-click
configuration
no need to involve IT to set up or maintain SQL
• Improved ad-hoc Reporting through OLE DB support
• Sub-second collection and microsecond timestamp
resolution for preserving device timestamps
• Advanced SCADA features rely on the PH4S engine for
optimal performance - e.g. iFIX Global Time Control and
historical on animations, scripts, etc. only work with
historian
• Our most powerful solutions and advanced analytics
require historical data… ideally lots of it, more than a
simple logger will easily handle
27
iFIX 5.8
Nov. 2013
Why upgrade from iFIX Classic?
Features
Classic
Historian for SCADA
Read Performance
Slower
Faster
Write Performance
Slower
High speed
Data resolution
1 sec resolution
1 millisecond resolution
Connectivity
ODBC and VB toolkit
OLEDB
Historical Playback
No
Yes
Enhanced Charts
No
Yes
Analytics-ready data
No, requires
transformation and import
to be queries
Yes, plug & play with Plant/Enterprise Historian
and Proficy analytics applications
Configuration and
Management
File-based
Requires management
Manual handling to view
offline older data
One-click configuration
Automated Archiving
Automated retrieval from older archives
Rich tools for backup
Centralization
No native ability
Server to server distributor
(push to central, all or selected)
Data Storage
Requirements
No compression, 40 bytes
per sample
Yes, rich capabilities, 6 bytes per sample plus
compression plus conditional collection…
OPC Time Stamping
No
Yes
Data Types
Analog
iFIX 5.8
Multiple, including Digital Tags, Lab data canNov.
be
2013
imported with CSV/XML and compression applied
28
iFIX v5.8 enables RtOI
islands of
information
aggregated
analytics in
real-time
Connecte
d
Data
Connecte
d
Insights
S2SD
iFIX 5.8
SCADA
Buffer
29
iFIX 5.8
Nov. 2013
®
Proficy
RtOI & iFIX
Actionable Access Unified Webspace
Anywhere
30
Unified Webspace
Single server to render iFIX, CIMPLICITY, Plant Applications
iPAD, Android, browser based iFIX, CIMPLICITY, Plant Applications clients
Unified Proficy Webspace Server
(Enabled for Multi-product clients)
iFIX
CIMPLICIT
Y
Proficy iFIX,
CIMPLICITY,
Plant Applications
Servers
Plant
Applications
31
iFIX 5.8
Nov. 2013
Unified Webspace
Enhances Mobility & Vision
iFIX, CIMPLICITY, Plant Applications
content initiated through Mobile
iFIX, CIMPLICITY, Plant Applications
content initiated through Vision
Proficy Application Server
Enabled with Unified Webspace
32
iFIX 5.8
Nov. 2013
Unified Webspace
Context passing to iFIX Sessions through Vision
Initiate specific Graphics
Through URLs in the Model
33
iFIX 5.8
Nov. 2013
iFIX v5.8 enables RtOI
Information finds you,
mobile access,
collaboration
Connecte
d
People
Mobile
Desktop/
Web
Unified
Webspace
34
iFIX 5.8
Nov. 2013
®
Proficy
RtOI & iFIX
SCADA Decision Support
Workforce Using Workflow
Enablement
35
Proficy HMI/SCADA – iFIX
SCADA Publishing to SOA
Proficy SOA
Data/Reporting
Common Services:
Licensing, Alarm & Event
Management, Installation,
Security, Localization,
Configuration
Workflow
Associate iFIX tags & alarms to an
Equipment Model
Common
Data Model
Directory of
Resources
Application
Development
Foundation
Enable native interaction with
Workflow for eSOPs and Alarm
Responses
Associate Operator SOPs with
SCADA screens to provide
A common User experience
36
iFIX 5.8
Nov. 2013
Consistent Operator action Option
Integrated SOPs
Manual Initiation of a Workflow by
the operator
Triggers the Workflow tasks
co-ordination
Easy integration!
The operator Interacts with
the Workflow task steps
37
iFIX 5.8
Nov. 2013
Consistent Operator action Option
Examples
Intrusion
Smoke Alarms
Flood Alarms
Pump Permissives
Time of Day Pumping
Pump Preferences
Intrusion Alarm
Triggered
Tag Out / Lockout
Off Scan
Maintenance
Did Field Operator
call?
No
Call to 911 Required?
Valve Permissives
Valve on COMM Fail
Yes
Log Notes
Water Quality Data
Checked
Log Notes
Tag Out / Lockout
Off Scan Maintenance
38
iFIX 5.8
Nov. 2013
iFIX v5.8 enables RtOI
Information finds you,
mobile access,
collaboration
Connecte
d
People
Mobile Notes/Tasks
Workflow
Workflow Integration with iFIX
39
iFIX 5.8
Nov. 2013
Thank You
Download