Education Central Engage, Apply, Retain Emerson 4” Series Thermostats Homeowner Support Hotline: 800-284-2925 Note: This module covers common elements. Refer to Specification Sheet or Installation Instructions for detailed information. Education You Can Build On Emerson 4” Thermostats Selecting the Right Thermostat for the Job Model Number Applications Programming Options Power Source ✓ 7+5+1+1, 5+2, Ø 4, Ø B,H 1F85-0422 1/1 2/2 2/2 ✓ ✓ ✓ 5+1+1, 5+2, Ø 4, Ø B,H 1F80-0471 1/1 1/1 ✓ ✓ ✓ 5+1+1, 5+2, Ø 4, Ø B,H 1F83-0471 1/1 2/2 3/2 ✓ ✓ ✓ Ø Ø B,H 1F83-0422 1/1 2/2 2/2 ✓ ✓ ✓ Ø Ø B,H 1F86-0471 1/1 1/1 ✓ ✓ ✓ Ø Ø B,H Humidity Control ✓ Heat Pump 1/1 2/2 3/2 ✓ Multi-Stage 1F85-0477 Single Stage Millivolt Compatible Single Stage (SS) Multi-Stage (MS) Heat Pump (HP1 or HP2) Universal (All) Stages Heat / Cool by System 3-Wire Zone Value Model Gas/Oil/Electric Application Coverage by System Program Hardwire Program Days Periods Battery or per Week per Day Power Assist Universal Single Stage / Heat Pump Universal Single Stage / Heat Pump 4” Series Thermostats Agenda • Applications • Wiring • Configuration • Programming Featured Products In This Module – 1F85-0477 • Multi Stage, Programmable – 1F86-0471 • Single Stage/ Non-Programmable Look at the Box for Detailed Information Staging by System Type Programming Options Applications Terminal Identification Part Number 4” Series Thermostat Overview • Single Stage or Universal 2 Heat/2 Cool • Easy-to-Read 4-Square-Inch Blue Display • Comfort Alert™ Compressor Protection • Keypad lockout • Adjustable Setpoint Temperature Limits • Battery Power Monitor • Choice of Programmable or Non-Programmable • +/-1 Degree Accuracy- For Optimum Comfort and Equipment Life 4” Series Specification Sheets Contain Detailed Information 4” Series Applications Application Conventional or Heat Pump with No Aux Stages Programming Type 0 1F86-0471 5+1+1, 5+2, 0 1F80-0471 0 1F83-0422 5+1+1, 5+2, 0 1F85-0422 0 1F83-0471 7, 5+1+1, 5+2, 0 1F85-0477 1/1 2/2 Universal 3/2 4” Series Terminal Designations 4" Series Terminal Description Programming Stages W W/E W2 Y Y2 O/B G RH and RC C L 6 1st Stage Heat (SS1) 1st. Stage Heat (MS2) or Aux Heat 1st Stage (HP) 2nd Stage Heat (MS2) or Aux Heat 2nd Stage (HP2) 1st Stage Compressor (SS, MS2 or HP) 2nd Stage Compressor (MS2 or HP2) Reversing Valve Combined Fan Relay 24 VAC Hot (TH) Separate 24 VAC Common (TR) Wire Diagnostics Wet Heat 3 Wire Zone Valve Note: Conventional Universal CONV or HP/No Aux * Conventional or Heat Pump/With Aux 1F850422 1F83-0422 1F85-0477 1F83-0471 5+1+1. 7, 5+1+1, 0 0 5+2, 0 5+2, 0 2/2 3/2 1F80-0471 1F86-0471 5+1+1. 5+2, 0 0 1/1 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● * Requires Field Wiring from Y to W for Heat Pump Batteries • Two “AA” alkaline batteries are installed in your thermostat with a battery tag to prevent power drainage. Prior to use, open the battery door and remove the battery tag. To open, pull the battery door as shown by the arrow and lift open • Thermostat can be powered by system AC power or Battery. If is displayed, the thermostat is battery powered. If is not displayed, thermostat is system powered with optional battery back-up • When “Change ” is displayed, install fresh “AA” alkaline batteries immediately. • NOTE: When less than two months of battery life remain, the set point temperature will offset by 10 degrees (10 degrees cooler in Heat mode / 10 degrees warmer in Cool mode). If offset occurs, the normal setpoint can be manually reset with UP or DOWN button . Another offset will occur within two days if batteries are not replaced. 4” Series Application Selection Switches • • SS/HP Switch Gas or Heat Pump Applications – Gas or Electric furnace applications W terminal is Heat • Ensure SS/HP switch is in the SS position – Single Stage Heat Pumps (no auxiliary heat) O/B terminal is Heat • Ensure SS/HP switch is in the HP position GAS/ELEC Switch Fan Operation – GAS position lets the equipment operate the fan on a call for heat – ELEC position lets the thermostat operate the fan on a call for heat—you will use this position for heat pumps or electric furnaces. SS/HP switch These switches are on the back of the thermostat and must be configured correctly for the application GAS/ELEC switch 4” Series Wiring Hydronic • Hydronic Applications – W terminal opens the hydronic valve identified as 4 on the valve – O/B terminal closes the hydronic valve identified as 6 on the valve – RH terminal is the hot side of the 24 VAC identified as 5 on the valve • Ensure SS/HP switch is in the SS position W This configuration is designated by #6 terminal on other thermostats 4” Series Wiring Gas • Gas Applications – For Single Stage wire the red terminals – For Multi-Stage wire the same, but add the second stage (green Y2 and W2) Ensure MS2 is selected in the configuration menu 4” Series Wiring Heat Pump • Heat Pump Applications – For Single Stage heat pumps where Y terminal is 1st stage compressor and W/E terminal is first stage aux heat, W2 is second stage aux heat. • Ensure HP1 is selected in the configuration menu If you only have one wire for aux/emergency heat install jumper W/E W2 4” Series Navigation Day of Week Actual Room Temperature Desired Temperature Temperature or Config Adjustment Buttons Time of Day Battery Status = Full Charge = Half Capacity = Replace Batteries Hold Button Auto Sched Button Heat/Cool/Off Fan Auto/On or Button Run Sched Button Run, Schedule or Menu Button 4” Series Entering System Configuration Most technical service calls are the result of improper system configuration 1. System must be in HEAT or A/C Mode 2. Press and hold the MENU button for five seconds 4” Series Configuration Menu Denotes Critical to the Application 1F80 and 1F86 Single Stage Menu # HP 1 1 2 2 3 3 SS Displayed Press Δ or to Select (Default) From Listed Options Comments (O) On b On 1 P (2) P 3, P 0 Selectable Programs Per Week 2 (OFF) CS On CS Select Cool Savings on or off (3) 6, 5, 4, 2, 1 3 (On) E (OFF) E Selects Energy Management Recovery (EMR) on or off 5 4 FA, SL Adjustable Anticipation Heat (SS/HP switch is at the SS position) 6 5 (ME) CR Heat (FA) CR Cool (FA) CR Heat Pump (OFF) CL SL Adjustable Anticipation Cool (SS/HP switch is at the SS position) SL Adjustable Anticipation (Heat Pump) (only when SS/HP switch is at the HP position) Compressor Lockout Time Heat Cool Off, Heat Off, Cool Off, Auto Off OFF L 4 4 7 5 8 6 6 9 7 7 Auto Heat Cool Off 10 8 8 (On) L 11 9 9 0 12 10 10 F 13 11 11 (OFF) Change Filter Change Filter 200 h 14 12 12 On CL Reversing Valve Output (SS/HP switch must be in HP position) Selects Cool Savings value 1 (low) to 6 (high) System Mode Configuration Selects Display Light on or off 1 HI, 2 HI, 3 HI, 4 HI, Adjustable Ambient Temperature Display 1 LO, 2 LO, 3 LO, 4 LO C Selects Fahrenheit/Celsius Temperature Display On Change Filter Selects Filter Change-out Indicator 25 h to 1975 h in 25-hour increment When on, selects time in 25 hour increments 25-hour increment Returns to Normal Operation 4” Series Configuration Menu Denotes Critical to the Application 1F83 and 1F85 Multi Stage or Heat Pump Menu # 1F85 1F83 HP MS/SS Press Δ or to Select From Displayed (Default) Listed Options Comments 1 1 ● ● (OFF) Lk L 2 2 ● ● (000) Lk 001 to 999 Selects Keypad lockout combination number 3 3 ● ● (MS 2) HP 1, SS 1 4 4 ● (GAS) ELE Selects Multi-Stage (MS 2 No Heat Pump), Heat Pump 1 (HP 1, 1 compressor), or Single Stage (SS 1) Select Gas or Electric heat (ELE) GAS ● Selects Keypad Lockout. 5 5 ● ● (0) CS 1, 2, 4, 5, 6 6 — ● ● (On) E OFF 7 6 ● SL, FA Adjustable Anticipation: Selects heating cycle rate for MS or SS 8 7 ● ● SL, FA Adjustable Anticipation: Selects the cycle rate for cooling 9 8 ● ● SL, FA Adjustable Anticipation Selects the cycle rate for Heat Pump 10 9 ● 11 10 ● ● (ME) CR Heat (ME) CR Cool (ME) CR Heat Pump (FA) CR Emer (OFF) CL 12 11 ● ● 13 12 ● ● Heat-AutoCool-Off (On) dL SL CL On Selects Cool SavingsValue Value 0 Disables Feature Selects Energy Management Recovery (EMR) On or OFF. Selects the cycle rate for Emergency mode and Auxiliary stage Compressor Lockout Time Auto-Off, Cool- Selects System Mode Configuration Off, Heat-Off dL OFF Selects Display Light On or OFF 4” Series Configuration Menu Denotes Critical to the Application 1F83 and 1F85 Multi Stage or Heat Pump Menu # HP Press Δ or Displayed to Select From (Default) Listed Options 1F85 1F83 14 13 ● ● 0 15 14 ● ● °F 1 thru 4 HI, 1 thru 4 LO °C 16 15 ● ● L (90) Heat L 62 to L 89 Selects Limited HEAT Range 17 16 ● ● L (45) Cool L 46 to L 82 Selects Limited COOL Range 18 — ● ● P3 P0, P2 19 — ● ● OFF 20 — ● ● 21 17 ● 22 18 ● 23 19 ● ● (On) AS Heat (On) AS Cool (On) FA Heat (On) FA Cool (OFF) CA 24 — ● ● (On) dS OFF 25 20 ● ● On 26 21 ● ● 27 22 ● ● (OFF) Change Filter (200 h) Change Filter (o) On Cool MS/SS OFF OFF OFF On 25-1975 h (b) On Heat Comments Adjustable Ambient Temperature Display Selects Fahrenheit/Celsius Temperature Display Defaults for 5-1-1 programming (P3) but non- programmable (PO) or 5-2 programming (P2) is available on most models. Automatic Schedule for heat mode. 1F85 only. NA to Cool only system. Automatic Schedule for cool mode. 1F85 only. NA to Heat only system. Fast Heat option may be disabled by selecting OFF. NA to SS config. NA to Cool only system. Fast Cool option may be disabled by selecting OFF. NA to SS config. NA to Heat only system. Selects active Comfort Alert On or OFF. Selects Automatic daylight Savings Time option On or OFF. 1F85 only Selects Filter Change-out Indicator On or OFF. Change Filter time in 25 hour increments. This menu only appears if On is selected in above. Selects operation of the reversing valve terminal (O/B) output as an O or B terminal. 4” Series Programming Worksheet Technical Service has never spoken to anyone who could not program the thermostat once they filled out the schedule worksheet in the manual and KEPT it. Save a call back and fill it out the form from the homeowners manual with the homeowner. Ensure they have the Homeowner Support Hotline: 800-284-2824 4” Series Set Time, Year, Month and Date 1. 2. 3. 4. 5. Press MENU and then TIME button once. The display will show the hour only. Press and hold either the UP/DOWN button until you reach the correct hour and the AM/PM designation Press Time button once. The display will show the minutes only. Press and hold either the UP/DOWN button until you reach the correct minutes Press TIME again 1. 2. 6. 401 will show the day of the week. Press the UP/DOWN button to change the display to the correct setting. 402 additional presses of TIME will advance the display to show the year, month and date of month. Press the UP/DOWN button to correct settings for each. Press Run to exit the Time mode. UP/ DOWN Time Menu/ Run 4” Configure Program Options • System must be set for Heat or Cool. Press the Menu button for at least 5 seconds. • The display will display step #1 in the configuration menu • Press the UP button to the configuration Menu No • Select the programs per week by pressing UP/DOWN button – “0” for non-programmable – “2” for a 5+2 – “3” for 5+1+1 • Note: Thermostat defaults to 4 programs per day • Press the Run button Model Number Configuration Menu No. Programs per week Programs per day 1F80 02 5+1+1 (3) 5+2 (2) 0 (0) 4 5+1+1, (3) 5+2 (2) 0 (0) 4 1F85 18 4” Series How To Set A Program Press SYSTEM button to HEAT or COOL 1. Press the MENU button and then press SCHEDULE 2. The top of the display will show the day(s) being programmed. The time and temperature (flashing) are also display. “1” will also be display to indicate the period 3. Press UP/DOWN button to change the temperature to your selected temperature 4. Press TIME button, time will flash 5. Press UP/DOWN button to adjust the start time for the period UP/ DOWN 1. The time will change in 15 minute increments 6. After you have set the time and the temperature for the period, press SCHEDULE to advance to the next program period 7. Repeat steps 2 through 8 until all of the program times and temperatures are set for all program periods on that day 8. Press SCHEDULE to the next day and repeat steps 2 through 9 9. Press Run to complete System/ Time Menu/ Schedule/ Run