CMV Mini VRF SYSTEM R410a, 50Hz Contents I. Brief Introduction II. Advantages III. Indoor units IV. Controllers CHIGO New Generation DC Inverter VRF System I. Brief Introduction 01. Product Line Up 02. Outdoor units 03. Indoor Units Line up 04. Nomenclature CHIGO New Generation DC Inverter VRF System Brief Introduction 01. Product Line Up Air-cooled scroll chiller VRF LCAC R410a,50HZ 380V-415V/3Ph;220V-240V/1ph CHIGO New Generation DC Inverter VRF System Brief Introduction 02. Outdoor Units 4 models All outdoor units have same size 10KW /12.5KW/14KW/16KW Each outdoor unit can connect more than one indoor unit, MAXIMUM 8 units can be connected. CHIGO New Generation DC Inverter VRF System 02. Outdoor Units Specifications CMV-V100W/ZR1-B CMV-V125W/ZR1-B CMV-V140W/ZR1-B CMV-V160W/ZR1-B Cooling mode Capacity 10KW 12.5KW 14KW 16KW Input 2.69KW 3.38KW 3.98KW 4.58KW Heating mode Capacity 11.5KW 14KW 16KW 18.5KW Input 2.91KW 3.66KW 4.3KW 5.13KW 7 8 Size W*H*D mm 900*1328*345 Noise level dB(A) 45 ~ 58 Max connected indoor unit quantity 6 6 380V-415V/3PH/50HZ ; 220V-240V/1PH/50HZ CHIGO New Generation DC Inverter VRF System Brief Introduction 03. Indoor Units Line Up 4-way cassette 4-way cassette Wall-mounted (compact type) Low ESP ducted unit Medium ESP ducted unit High ESP ducted unit Floor Ceiling Fresh air processor Cap. (kW) 2.2 2.8 ● ● ● ● ● ● ● 3.2 ● 3.6 ● ● ● ● 4.5 ● ● ● ● ● 5.6 ● ● ● ● 7.1 ● ● ● 8.0 ● ● ● ● ● ● ● 9.0 ● ● ● ● 10.0 ● ● ● 11.2 ● 12.0 ● 12.5 ● 14.0 ● 15.0 16.0 ● ● ● ● ● ● ● ● CHIGO New Generation DC Inverter VRF System Brief Introduction 04. How To Read The Model Name CMV - V 100 W / Z R1 Design code B: 2nd generation Refrigerant type R1: R410a Power supply Z: 380-415V/3PH/50Hz Omit:220-240V/1PH/50Hz Outdoor unit Capacity (*100W) Compressor code V: Inverter Chigo VRF system CHIGO New Generation DC Inverter VRF System Brief Introduction 04. How To Read The Model Name CMV - V 125 TB / H R1 - Design code B: 2nd generation Refrigerant type R1: R410a Function code H: Heat pump Indoor unit code Q: 4-way cassette G: Wall-mounted TA: Low ESP ducted TB: Medium ESP ducted TH: High ESP ducted LD: Floor ceiling Capacity (*100W) Compressor code V: Inverter Chigo VRF system CHIGO New Generation DC Inverter VRF System II. Advantages 01. High efficiency 02. Benefit for users 03. Benefits For Installers 04. Doctor Kit CHIGO New Generation DC Inverter VRF System CHIGO New Generation DC Inverter VRF System High Efficiency 01. High Efficiency DC Inverter Compressor Twin-rotor DC inverter compressor • Rotating speed can be down to 20RPS • Has very good efficiency in part load condition High efficiency High reliability Low vibration Low noise Long life CHIGO New Generation DC Inverter VRF System High Efficiency 01. High Efficiency DC Inverter Compressor High Efficiency, Low Noise: Optimized the efficiency and noise during operation with the latest technology. Environmental Protection: Developed the compressor with alternative refrigerant which can protect environment. Low Vibration: Reduced the vibration during compressor start and operation by using 2CYL Structure, simplified the match of air-conditioning. CHIGO New Generation DC Inverter VRF System High Efficiency 02. High Efficiency DC Motor High efficiency DC fan motor Low noise and high efficiency because of high-density wire winding engineering Brushless with built-in sensor AC motor •Low efficiency •Big noise •Not adjustable CHIGO New Generation DC Inverter VRF System High Efficiency 03. DC Motor Stepless Control DC fan motor can be stepless controlled by outdoor PCB according to system's operating temperature and frequency. And it is able to reduce the energy consumption and maintain the system in the best performance. Revolution (rpm) DC motor stepless adjustment AC motor 2-speed adjustment 1400 Energy wasted Low performance 1200 700 200 Load 0% 50% 100% 130% CHIGO New Generation DC Inverter VRF System High Efficiency 04. 180˚ Sine Wave Control The perfect combination of 180˚ Sine wave rotor frequency drive control technology and excellent IPM inverters, reduces the reactive loss of motordriven, increases motor efficiency by 12%. Conventional control waveform Increase efficiency by 12% 180˚ Sine Wave vector Control CHIGO New Generation DC Inverter VRF System High Efficiency 05. CCT Inner-grooved Tube CCT (Continuous Cooling Transformation) innergrooved copper tube has high inner-grooved fins break the refrigerant flow boundary layer to enhance refrigerant disturbance to increase heatexchanging efficiency. Coefficient of heat transfer, kW/(m2·K) thermometric conductivity. Its CCT Inner-grooved Tube 6 Conventional Tube 5 4 100 200 300 400 Refrigerant mass flow, kg/(m2·K) CHIGO New Generation DC Inverter VRF System High Efficiency 06. High Performance Heat Exchanger Has low air resistance and great heat transfer coefficient Frosting improved, frost on the heat-exchanger will be well-distributed, Coefficient of heat transfer kW/(m2·K) easy for defrosting. Cross Flow Fins 300 Conventional Fins 200 100 0 2 4 Face velocity, m/s CHIGO New Generation DC Inverter VRF System CHIGO New Generation DC Inverter VRF System Benefits For Users 01. Excellent In Efficiency Thanks to DC devices(compressor and motor), piping optimization design and new control logic, system's EER and COP are observably increase. 5 4 3.97 3.73 3.70 3.84 3.54 3.72 3.503.61 3.62 3.78 3 Cooling EER Heating COP 2 1 0 10KW 12.5KW 14KW 16KW Average CHIGO New Generation DC Inverter VRF System Benefits For Users 02. Outstanding Comfort Ability Precisely room temperature control by adopting large pulse EXV. Indoor temperature fluctuation can be maintain within 0.5 ˚C, offers outstanding comfort ability. Room Temperature Mini VRF 25oC Conventional fixed speed system ±0.5˚C Time CHIGO New Generation DC Inverter VRF System Benefits For Users 02. Fast cooling and heating Every rooms meet set point most quickly and comfortably by optimized refrigerant control. Normally running Some indoor unit get to set point Stop @ Set point Stop @ Set point CHIGO New Generation DC Inverter VRF System Benefits For Users 03. Wide Outdoor Operation Range. Because global warming is -5˚C getting worse, Max. cooling operating temperature is increased to 50˚C, -10˚C Cooling range 0 ˚C 10 ˚C 20 ˚C 30 ˚C 50˚C 40 ˚C 50 ˚C Heating operating temperature is down to -20˚C. In the cold winter, system can heat the room continuously. -20˚C -20˚C Heating range -10˚C 0˚C 10 ˚C 30˚C 20 ˚C 30˚C CHIGO New Generation DC Inverter VRF System Benefits For Users 05. Intelligent Defrosting Program Program starts only when unit needs to. Whereas conventional unit's defrosting timing & duration is fixed, causing fluctuations in temperature and personal comfort. Heating Capacity output Conventional unit's defrosting timing & duration is fixed Time Intelligent defrosting program starts according to heat exchanging efficiency & capacity change due to the frost. Less temperature fluctuations, people feel more comfortable. CHIGO New Generation DC Inverter VRF System Benefits For Users 06. Fan Reversal Protection In standby, if the outdoor fan motor is rotating in opposite direction at a high speed by the wind or other natural factors, the unit can’t start so as to keep the fan motor from broken down. It will start when the fan motor speed slow down. CHIGO New Generation DC Inverter VRF System Benefits For Users 07. Flexible For All Kinds Of Rooms 8 types & 55 models of indoor units, suitable for all kinds of rooms. CHIGO New Generation DC Inverter VRF System CHIGO New Generation DC Inverter VRF System Benefits For Installers 01. Long Pipe & Height Difference. The total pipe length: 125 m The longest pipe length: 50 m distributor to last indoor unit: <25m Length from first indoor <15m units: 15 m <50m Height difference between indoor <30m Height deference: 30 m 25 m CHIGO New Generation DC Inverter VRF System Benefits For Installers 02. Space saving installation Multiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible. Compare to one-drive-one type, the outdoor unit can be installed in various places to realize the space-saving installation. CHIGO New Generation DC Inverter VRF System Benefits For Installers 03. Addressing Methods Automatically addressing: system will distribute address to indoor unit automatically Automatic addressing will reduce artificial faults and manual works. CHIGO New Generation DC Inverter VRF System Benefits For Installers 04. Automatic Addressing Automatic addressing will reduce artificial faults and manual works. • 54% system failure were caused by communication faults. • 65% communication faults were caused by address problems. • Most of the address problems were: address setting forgotten, wrong settings, address repeat. Failure chart Communication faults Others 65% ⇨ Address faults was awarded to the most hated fault after had 54% investigated 120 Others Addressing problems VRF after-sale engineers in 2011. CHIGO New Generation DC Inverter VRF System Benefits For Installers 05. LED Display On PCB LED display on the PCB, it can show system's operation status and error codes. CHIGO New Generation DC Inverter VRF System Benefits For Installers 06. Mode Restriction 5 kinds of mode restriction • First start indoor units priority mode • Cooling (or heating) priority mode • Cooling only (or heating only) mode Mode restriction function can be selected on the outdoor PCB. CHIGO New Generation DC Inverter VRF System Benefits For Installers 7. Oil Control Technology Core oil control technology makes system safety & reliable. Intelligent oil return program Oil level control Oil even pipe Oil separator Separation efficiency 92% CHIGO New Generation DC Inverter VRF System Benefits For Installers 8. 3-phase Power Protector (Optional Device) Protect the outdoor unit from instable voltage. CHIGO New Generation DC Inverter VRF System CHIGO New Generation DC Inverter VRF System Doctor Kit 01. Easy To Use Doctor Kit includes: 1 CD software and RS485-USB converter, easy to install Graphical interfaces, easy to use CHIGO New Generation DC Inverter VRF System Doctor Kit 02. Data Monitoring We can use computer to inquiry outdoor unit's operating status, error codes when connecting to Doctor Kit. Compressors, sensors, valves operating parameter can be real-time monitored. System operating parameter curve can be real-time displayed. CHIGO New Generation DC Inverter VRF System Doctor Kit 04. Troubleshooting Built-in with troubleshooting instruction, user can follow the instruction to solve the problem when error happens. User can also print out the instruction and take it to site to solve the problem step by step. CHIGO New Generation DC Inverter VRF System Doctor Kit 05. Automatic Data Backup Automatic Data Backup: all operating data will be saved on hard disk automatically. Data file can be exported easily by software. When system failure, user can send the data file to Chigo, Chigo's engineer will check and guide you to solve the problem. 10 hours data = 1MB CHIGO New Generation DC Inverter VRF System Doctor Kit 06. Charged Refrigerant Volume Calculator Input the liquid pipe diameter and length, software will calculate the additional refrigerant charged volume. Charged volume can be saved for future reference. Discharge pressure can be monitored when charging refrigerant. CHIGO New Generation DC Inverter VRF System Ⅲ. Indoor Units 01. 4-way cassette 02. Wall-mounted 03. Floor ceiling 04. Low ESP Ducted type 05. Medium ESP Ducted type 06. High ESP Ducted type 07. Full fresh air processor CHIGO New Generation DC Inverter VRF System Indoor Units 01. 4-way Cassette Standard type: • Capacity: 2.8 kW to 16 kW • Size: 840 × 893mm • Built-in with EXV and water pump • Pumping head 750mm Compact type: • Capacity: 2.2 kW to 4.5 kW • Size: 580*580mm, • Built-in with EXV and water pump • pumping head 700mm CHIGO New Generation DC Inverter VRF System Indoor Units 02. Wall-mounted Capacity: 2.2 kW to 7.1 kW 2 types of unit can be chosen: EXV Built-in type EXV separated type Compact size and low noise CHIGO New Generation DC Inverter VRF System Indoor Units 03. Floor Ceiling Capacity:4.5kW to 16.0kW Flexible installation: • vertical or horizontal Built-in with EXV Comfortable air delivery swing adjustment: • Left and right, • Up and down CHIGO New Generation DC Inverter VRF System Indoor Units 04. Low ESP Ducted Type Capacity 2.2 kW to 7.1 kW External static pressure: 20 Pa Built-in with EXV Low noise, and light weight Slim body, only 180 mm height Air return box and filter is optional CHIGO New Generation DC Inverter VRF System Indoor Units 05. Medium ESP Ducted Type Capacity: 7 kW to 15 kW Air return for rear External static pressure: 70Pa Built-in with EXV Flexible installation, many options Air return method can be site changed Air return from bottom CHIGO New Generation DC Inverter VRF System Indoor Units 06. High ESP Ducted Type Capacity: 7 kW to 15 kW 7.1kW / 8.0kW / 9.0kW External static pressure: 150Pa Built-in with EXV Suitable for long distance air supply 10.0kW / 12.0kW / 15.0kW CHIGO New Generation DC Inverter VRF System Ⅳ. Controllers and Software 01. Wireless remote controller 02. Wired controller 03. Group controller 04. BMS Gateway 05. Centralized control system 06. Doctor Kit 07. CMV selection software CHIGO New Generation DC Inverter VRF System Controllers and software 01. Wireless Remote Controller Indoor unit address inquiry Standard Optional Indoor unit address setting Temperature setting Operation mode setting Fan speed setting Timer function CHIGO New Generation DC Inverter VRF System Controllers and software 02. New Wired Controller Bidirectional communication. Indoor unit's operating parameters (error code, temperature, address) can be inquired and displayed on the controller. Compact design 3'' screen with white background light Timer function Electrical standard dimensions CHIGO New Generation DC Inverter VRF System Controllers and software 03. Group Controller Easy to install. Controller connects to outdoor units only. Able to install group controller after building decoration. 1 Controller can control max. 64 indoor units in different systems. CHIGO New Generation DC Inverter VRF System Controllers and software 03. Group Controller Wireless/wired control restriction Operation mode restriction Timer function Error or protection code display CHIGO New Generation DC Inverter VRF System Controllers and software 04. BMS Gateway BACnet gateway Modbus gateway BMS/BAS System Honeywell Siemens Johnson controls Etc… Mini CMV system Gateways …… CHIGO New Generation DC Inverter VRF System Controllers and software 05. Centralized Control System Billing function Operating report output Schedule management 1024 indoor unit can be connected Control indoor units with fully permissions. CHIGO New Generation DC Inverter VRF System Controllers and software 06. Doctor Kit Operating status, error codes inquiry Compressors, sensors, valves operating parameter real-time monitored and display. Commissioning results can be reported. Built-in with troubleshooting instruction Automatic Data Backup CHIGO New Generation DC Inverter VRF System Controllers and software 07. CMV Selection Software CHIGO New Generation DC Inverter VRF System CHIGO New Generation DC Inverter VRF System latest developments 1st time test of trail production is done. CHIGO New Generation DC Inverter VRF System