Storwize V7000 IP Replication solution explained

advertisement
Storwize V7000 IP Replication solution explained
Storwize V7000
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
2U

Control enclosure: dual controllers and up to twelve 3.5” or twenty-four 2.5” drives in just 2U

Eight 8Gb FC ports plus four 1Gb iSCSI ports per controller pair initially (10Gb iSCSI and FCoE post-GA)

Expansion enclosure: drives only

Up to nine expansion enclosures attach to one control enclosure
Built-in Software inherited from SVC and DS8000 RAID
Manageability

RAID 0, 1, 5, 6, 10

New User interface (easy-to-use, web based)

Storage Virtualization
(internal disks and external arrays)

Integrated SAN-wide Management
(Tivoli Storage Productivity Center)

Non-disruptive Data Migration

Integrated IBM server and storage mgmt (Systems
Director Storage Control)
Efficiency

Thin Provisioning

Easy Tier
(dynamic data movement across SSD/HDD)
Replication

Application integrated
(Oracle, DB2, SAP, Domino, Exchange, SQL Server)

Efficient use of space
(thin provisioned, incremental, deduplicated)

DR automation (failover/fail back, site switching)

IP or Fibre Channel
2
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
Solutions at a Glance
Productivity Center
Application
server
Primary
data
TSM Admin Center
Local
FlashCopy
Versions
iSCSI/FC
FC Mirroring
(Sync or Async)
FlashCopy
Manager
Instant
Restore
Or
FastBack
agent
.
.
.
IP Replication
(Copy)
(SAS/NL-SAS)
Application
data
External
Virtualization
Storage Manager 6
FastBack
agent
ProtecTIER
deduplication
gateway
Backup path
Restore path
3
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Replication Features
Overview
 IP Replication
– Application-integrated capabilities for clients needing
instant recovery with cost-optimized disaster
recovery options
4
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Application server
Application
server
Primary
data
iSCSI/FC
– Windows or Linux
servers
● Often times VMWare
guests
– Having file systems
– Running mail
applications like MS
Exchange or Lotus
Domino
– Running database
applications like MS
SQL Server, DB2, or
Oracle
5
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
Application
server
Primary
data
iSCSI/FC
FastBack
agent
 Implementing
Storwize V7000 IP
Replication
– Add TSM FastBack
agents to each
application host
6
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
Application
FastBack
server
server
iSCSI/FC
FastBack
agent
Primary
data
 Implementing
Storwize V7000 IP
Replication
– Add TSM FastBack
agents to each
application host
– Add a TSM FastBack
server machine
(Windows, likely a new
VMWare guest)
7
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing Storwize
V7000 IP Replication
Application
FastBack
server
server
Primary
data
Local
snapshot
Versions
iSCSI/FC
FastBack
agent
.
.
.
– Consistent volume snapshots
can be made of
● file systems
● supported apps
● any application through a
customization interface
– Snapshot are incremental
and can be stored on thin
provisioned volumes
– Local snapshots have the
added benefit of being
deduplicated.
– Although FastBack snapshots
are software-based and do
not use Storwize V7000
FlashCopy, plan for needed
space as you would for
FlashCopy
8
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
Application
FastBack
server
server
Primary
data
Local
snapshot
Versions
iSCSI/FC
FastBack
agent
.
.
.
Primary
data
 Implementing
Storwize V7000 IP
Replication
– Because Fastback
snapshots are SWbased…
– FastBack agents can
be used to snapshot
data not stored on the
Storwize V7000…
– With the snapshot
targets being stored on
the Storwize V7000
FastBack
agent
9
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
FastBack
server
Primary
data
Local
snapshot
Versions
iSCSI/FC
FastBack
agent
.
.
.
FastBack DR
Hub
 Implementing
Storwize V7000 IP
Replication
– At the remote site, a
FastBack DR Hub is
implemented on
another Windows
machine (often a
VMWare guest)
Primary
data
FastBack
agent
10
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing
Storwize V7000 IP
Replication
IP Replication
(Copy)
Primary
data
Local
snapshot
Versions
Replicated
snapshot
Versions
.
.
.
.
.
.
iSCSI/FC
FastBack
agent
Primary
data
FastBack
agent
– Local snapshots are
replicated (copied) by
the local FastBack
server to the remote
FastBack DR Hub over
IP.
– Replicated snapshots
remain incremental and
can also be stored on
thin provisioned
volumes.
11
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing Storwize
V7000 IP Replication
IP Replication
(Copy)
Primary
data
Local
snapshot
Versions
Replicated
snapshot
Versions
iSCSI/FC
FastBack
agent
.
.
.
Primary
data
.
.
.
– In the event of a failure,
there are two recovery
options.
● For individual file
recovery, FastBack Mount
allows a snapshot to be
directly mounted read-only
by a host server to copy
individual files back to the
Primary volume.
FastBack
agent
12
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing Storwize
V7000 IP Replication
IP Replication
(Copy)
Primary
data
Local
snapshot
Versions
Replicated
snapshot
Versions
iSCSI/FC
FastBack
agent
.
.
.
Primary
data
.
.
.
– In the event of a failure,
there are two recovery
options.
● For individual file
recovery, FastBack Mount
allows a snapshot to be
directly mounted read-only
by a host server to copy
individual files back to the
Primary volume.
FastBack
agent
13
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing Storwize
V7000 IP Replication
IP Replication
(Copy)
Primary
data
Local
snapshot
Versions
Replicated
snapshot
Versions
iSCSI/FC
FastBack
agent
.
.
.
Primary
data
.
.
.
– In the event of a failure,
there are two recovery
options.
● For individual file
recovery, FastBack Mount
allows a snapshot to be
directly mounted read-only
by a host server to copy
individual files back to the
Primary volume.
FastBack
agent
14
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing Storwize
V7000 IP Replication
IP Replication
(Copy)
Primary
data
Local
snapshot
Versions
Replicated
snapshot
Versions
iSCSI/FC
FastBack
agent
.
.
.
Primary
data
FastBack
agent
.
.
.
– In the event of a failure,
there are two recovery
options.
● For individual file
recovery, FastBack Mount
allows a snapshot to be
directly mounted read-only
by a host server to copy
individual files back to the
Primary volume.
● For full volume recovery,
snapshots can be instantly
restored to the primary
volume.
15
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing Storwize
V7000 IP Replication
IP Replication
(Copy)
Primary
data
Local
snapshot
Versions
Replicated
snapshot
Versions
iSCSI/FC
FastBack
agent
.
.
.
Primary
data
FastBack
agent
.
.
.
– In the event of a failure,
there are two recovery
options.
● For individual file
recovery, FastBack Mount
allows a snapshot to be
directly mounted read-only
by a host server to copy
individual files back to the
Primary volume.
● For full volume recovery,
snapshots can be instantly
restored to the primary
volume.
16
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing Storwize
V7000 IP Replication
IP Replication
(Copy)
Primary
data
Local
snapshot
Versions
Primary
data
Replicated
snapshot
Versions
iSCSI/FC
FastBack
agent
.
.
.
Primary
data
FastBack
agent
.
.
.
– In the event of a failure,
there are two recovery
options.
● For individual file
recovery, FastBack Mount
allows a snapshot to be
directly mounted read-only
by a host server to copy
individual files back to the
Primary volume.
● For full volume recovery,
snapshots can be instantly
restored to the primary
volume.
17
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing
Storwize V7000 IP
Replication
IP Replication
(Deduplicated Copy)
Primary
data
Local
snapshot
Versions
Replicated
snapshot
Versions
iSCSI/FC
Storage Manager 6
FastBack
agent
.
.
.
Primary
data
FastBack
agent
.
.
.
– In enterprise
environments,
snapshots can also be
replicated to a central
TSM server.
– With a TSM server
target, the network
traffic and replicated
snapshot versions have
the added benefit of
being deduplicated.
18
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing Storwize
V7000 IP Replication
IP Replication
(Deduplicated Copy)
Primary
data
Local
snapshot
Versions
Replicated
snapshot
Versions
iSCSI/FC
Storage Manager 6
FastBack
agent
.
.
.
Primary
data
.
.
.
– In the event of a failure,
the same two recovery
options are available.
● For individual file
recovery, FastBack Mount
allows a snapshot to be
directly mounted read-only
by a host server to copy
individual files back to the
Primary volume.
FastBack
agent
19
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
IP Replication explained
 Implementing Storwize
V7000 IP Replication
IP Replication
(Deduplicated Copy)
Primary
data
Replicated
snapshot
Versions
Local
snapshot
Versions
iSCSI/FC
Storage Manager 6
FastBack
agent
.
.
.
Primary
data
FastBack
agent
iSCSI/FC
Primary
data
.
.
.
– In the event of a failure,
the same two recovery
options are available.
● For individual file
recovery, FastBack Mount
allows a snapshot to be
directly mounted read-only
by a host server to copy
individual files back to the
Primary volume.
● For full volume recovery,
snapshots can be instantly
restored to the primary
volume.
20
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
 Required Software
–5639-VM1 (Base)
●Management GUI
●Thin Provisioning
●Easy Tier
●FlashCopy
 Hardware (MT/Model)
–2076-112
(12-bay LFF control enclosure)
–2076-124
(24-bay SFF control enclosure)
–2076-212
(12-bay LFF expansion enclosure)
–2076-224
(24-bay SFF expansion enclosure)
 Optional Software
– Management
●
●
5608-E14
(TPC for Disk Midrange Edition)
5765-ASM
(Director Storage Control plug-in)
– IP Replication
●
5639-FB1
(FastBack for Storwize V7000)
– FC Replication
●
●
●
5608-AC6 (FlashCopy Manager)
5639-RM1 (Mirroring)
5608-WB2 (TPC for Replication)
– Embracing legacy disk
●
5639-EV1 (External virtualization)
 Optional Services
21
© 2010 IBM Corporation
Smarter Systems for a Smarter Planet
Storwize V7000
 Required Software
–5639-VM1 (Base)
●Management GUI
●Thin Provisioning
●Easy Tier
New AAS PID postponed
●FlashCopy
until 1Q11
Sell traditional FastBack in 4Q10
function
 Hardware•Same
(MT/Model)
–2076-112•Different pricing metric
•Passport
Advantage
(12-bay LFF
control
enclosure)
–2076-124
(24-bay SFF control enclosure)
–2076-212
(12-bay LFF expansion enclosure)
–2076-224
(24-bay SFF expansion enclosure)
 Optional Software
– Management
●
●
5608-E14
(TPC for Disk Midrange Edition)
5765-ASM
(Director Storage Control plug-in)
– IP Replication
●
5639-FB1
(FastBack for Storwize V7000)
– FC Replication
●
●
●
5608-AC6 (FlashCopy Manager)
5639-RM1 (Mirroring)
5608-WB2 (TPC for Replication)
– Embracing legacy disk
●
5639-EV1 (External virtualization)
 Optional Services
22
© 2010 IBM Corporation
Download