Central DCS Shift Tutorial

advertisement
D
C
entral
S
Central DCS Tutorial
-Shutdown editionMade by :
Etiennette Auffray
Andrea Barisone
Last Revision : June 27, 2013
1
Central DCS Team
D
C
entral
S
Central DCS Expert Team:
Frank Glege (71688, 163919)
Robert Gomez-Reino Garrido (71654, 162366)
Lorenzo Masetti (165820)
Giovanni Polese (165807)
DCS expert on Call : 162229
Central DCS Operation:
Central DCS desk : 75140
Etiennette Auffray >> Shift organisation, Tutorial, Twiki : (75844, 163646)
Andrea Barisone >> Tutorial, Twiki
Central DCS shift requirements:
• CERN ID card and access to P5 and USC ( request done by EDH)
• All safety trainings up-to-date, including the Biocell training. For more information,
please visit: http://cms-safety.web.cern.ch ;
• At least the token.
2
D
C
entral
S
CMS Slice View
3
DCS Workstation : Screens
D
C
entral
S
Cooling Panel
Racks Panel
Sensors 4 CMS Panel
DSS Screens
Main DCS Panel
Cavern Access
GTPM Panel
DCS alarm Panel
Subdetectors Panel
4
Cavern Access : Screens
D
C
entral
S
Cavern Access Displays
WP Display
Intercom
Experimental
Cavern Doors
Telephone
Speaker for the
UXC and USC
Cavern
5
D
C
entral
S
DSS Screens
UXC 55
USC 55
6
DCS Mobile Phone
D
C
entral
S
DCS Mobile Phone
7
Central DCS General Guideline
D
C
entral
S
 As a general guideline all variables controlled and
monitored by central DCS should be GREEN
 If not green, a corresponding alarm will be raised and
will appear in the central DCS Alarm Screen;
 Therefore it is very important to monitor the alarm
screen during your shift and have prompt action in case
of any alarm;
 In the next transparencies, the central DCS shifter
tasks will be visited one by one, keeping in mind this
general guideline.
8
Main DCS Tasks
D
C
entral
S
1. What to do when a DCS alarm occur during the Shift
(Concerned Screen : DCS Alarm Panel )
3. What to do when a DSS alarm occur during the Shift
(Concerned Screen : DSS Alarm Panels)
4. Monitoring Operation:
 Services (Racks and Cooling)
5. Underground Cavern Access Management
6. DCS Elog : (When and How use it)
9
DCS Alarm Screen
D
C
entral
S
This screen should be :
 Checked regularly
 Empty
Each time an important problem occurs (subdetectors, services, etc…) an alarm
(together with an audible alert) should appear on this screen
10
DCS Alarm Screen
Below you find a row where there are several
information regarding the alarm : select and
right click on it and a pop up window will appear
D
C
entral
S
On the first line of the page
you can see which
subdetector is affected by
the problem : the alarm will
continue blinking until
handled by the DCS shifter
Read Instructions to correctly
handle the alert :
In case you don’t know how to
solve it call the responsible
If there is no instruction send an
email to us
11
DCS Alarm Screen
SUBDETECTORS MAIN LINE:
Colors meaning list :
LIGHT BLUE : No errors
RED: Fatal alert
ORANGE: Error
YELLOW: Warning
GREY: Alert acknowledgeable
D
C
entral
S
Time stamp (when shifter
has clicked on Alarm Help)
Direction box :
CAME :
The condition which triggered the
alarm is still present
WENT :
The condition which triggered the
alarm has disappeared
12
D
C
entral
S
Monitor Services
13
Service Screens (Rack Panel )
D
C
entral
S
Racks summary
Racks Cooling
Station.
Rack Power Status per
underground area
S1-S4 = Service Cavern
X0-X5 = Exp. Cavern
If you click
on 1 rack you
get details
on it
Take actions
on racks.
Follow the
instructions
Color code:
Grey – Not used
Green – OK
-----------------------Blue – OFF ->
Red – ERROR ->
requires intervention!
14
Service Screens (Rack Panel )
D
C
entral
S
Rack details
15
TOP PART OF THE SCHEME
entral
Service Screens
(Cooling)
Cooling
Panel
D CS
Outside
working hours
hours:(8h30/17h30) no matter which
During working
TOP
PART
of the screen:
doubt
or change
of color: CMS cooling support, 163021
ORANGE, write on DCS e-log, RED - Call CCC 72201
BOTTOM PART of the screen (flow & tank levels) :
ORANGE : 17h30/24h00 call 165000 24h00/7h00 ignore,
RED, call 165000
Color code:
Green – OK
-------------------------Yellow – warning
Orange – Error
Red – FATAL ERROR
Blinking Values
requires intervention!
BOTTOM PART OF THE SCHEME
Copper circuit leak
Warning: 1 l/h > 60 min
Alarm: 4 l/h >30 min or 8
l/h >1 min
Aluminum circuit leak
Warning: 1 l/h > 60 min
Alarm: 4 l/h >30 min
min or 8 l/h >1 min
Rack circuit leak
Warning: 2 l/h > 60 min
Alarm: 6 l/h >30 min
min or 8 l/h >1 min
Service Screens (Cooling)
D
C
entral
S
Blinking values
• If a value is blinking:
 you should verify at http://dipg.cern.ch/dipg if there are invalid CMS
cooling values. In case the bullet corresponding to CMS Cooling is red, it is
very likely to be a problem on the CCC side.
 You should call the CCC (72201) to inform them there is a problem with their
publications and point to them what you see from the link above.
 If there are no invalid values in the link above, call the central DCS expert
and inform about the problem.
 The interface from above is slow, so you should wait about 10 minutes to
make sure it is updating, before reporting the problem.
17
DSS :Detector Safety System
Front End
warning light :
should be always
green. If not, call
Alain Meynet,
between 7:00
and 22:00. If red
during the night,
call Alain Meynet
in following the
morning.
If there is a DSS Alarm with Siren and
light, the DCS shifter should
immediately call the Technical
coordination number 165000
DSS Alive. Should
blink.
User should
always be set to
‘user’. If not, click
on Logout. The
panel will restart
automatically.
Stop Siren button: stops the siren in
the DSS hardware panel when there is
an alarm. Only works from the DSS
USC55 panel!
D
C
entral
S
Right-click on the
alarm and select
‘Show’ to obtain
more
information. If
the alarm’s
“Triggered” state
is red, it cannot
be
acknowledged.
To acknowledge
an alarm:
1. click on the
ALARM
column, on
the DSS
ALARMS list;
2. Then click on
the ACTIONS
column of
the DSS
ACTIONS list.
DSS :Detector Safety System
D
C
entral
S
In case of alarms:
 read the alarm description and contact
the responsible person
(e.g. Magnet,
subdetectors, etc.);
In case the alarm description is not clear:
 during working hours: call DSS expert,
Alain Meynet: 163146;
 out of working hours: call Christoph
Schaefer: 160202 or Wolfram Zeuner:
162541 and at last 165000 (in case the
other numbers failed).
Check the DSS display is Alive:
 These buttons should blink. If not, restart
the panel (instructions in the DSS binder).
If restart does not work, call : 162082
19
DSS :Detector Safety System
D
C
entral
S
DSS Hardware
Piquet: 162082
20
Underground Cavern Access
D
C
entral
S
 Every person going underground (Service and Experimental caverns)
is required to fill in the paper version of the 'Access to Experimental
and Service Caverns' list that can be found in a binder by the Shift
Leader's desk;
 The central DCS shifter has to check that the person fills this form
when he/she goes into the cavern and when he/she returns;
 The person has to have a mobile phone;
 If after some time the person is not back in the control room, call
him/her to check everything is ok.
You can find detailed information on underground access in the cDCS twiki:
https://twiki.cern.ch/twiki/pub/CMS/OnlineWBCentralDCSInstructions/DCScavernAccess1.3.pdf
21
Cavern Access : Screens
D
C
entral
S
Cavern Access Displays
WP Display
Intercom
Experimental
Cavern Doors
Telephone
Speaker for the
UXC and USC
Cavern
22
Underground Cavern Access
1.
D
C
entral
S
Each person that wants to access the experimental cavern has to be properly registered in a WP;
2)
The Access management software
Work Packages (WP) is reachable
from the CMS Online Page
( clicking on ACT ) or directly from
this url :
http://cmsonline.cern.ch/portal/
page/portal/CMS%20online%20s
ystem/ACT
Underground Cavern Access
3) Once inside DCS Shifter has to select : “Document Database “
D
C
entral
S
Underground Cavern Access
4.
D
C
entral
S
go up on the left side of the page and select “Shifter Page”)
4
25
Underground Cavern Access
5.
6.
7.
8.
D
C
entral
S
Enter the name of the person willing to enter of the cavern
The list of assigned WP will appear
Select the WP to see its status.
To start the WP Select in the menu status : Ongoing
5
8
6, 7
26
Underground Cavern Access
9.
D
C
entral
S
Turn the dosimeter ON; (Push the black
button three times : once for each
message will pop up on its little screen
(CHANGE >> ENTER >> 1mv) : then a red
light will flash few seconds and also you
will hear a “bip”)
10. Select the dosimeter number in the
‘Operational Dosimeter’ field;
11. Read the initial dose from the dosimeter
and fill it in the appropriate field of the Shift
Operation page;
12. Click ‘Ok’ to grant access to the person;
Point 10 to 13
13. By the return of the dosimeter, fill in the
final dose and click ‘Ok’;
14. Turn the dosimeter OFF (simply push the
black button on top of the dosimeter, the
word “CHANGE” will appear, keep on
holding the black button until the word
“GO OFF” shows up. Then immediately
release the black button. If one waits for
too long to release the black button, the
27
dosimeter will not switch off).
Underground Cavern Access
9-14
Button
9.
Dosimeter number
D
C
entral
S
Turn the dosimeter ON; (to do that, push
the black button three times : once for
each message will pop up on its little
screen (CHANGE >> ENTER >> 1mv) : then
a red light will start flashing)
10. Select the dosimeter number in the
‘Operational Dosimeter’ field;
11. Read the initial dose from the dosimeter
and fill it in the appropriate field of the Shift
Operation page;
12. Click ‘Ok’ to grant access to the person;
13. By the return of the dosimeter, fill in the
final dose and click ‘Ok’;
Red flashing light
Dosimeter display
9-14
After an access:
DCS shifter has to make sure the lights in UXC are
switched OFF.
14. Turn the dosimeter OFF (simply push the
black button on top of the dosimeter, the
word “CHANGE” will appear, keep on
holding the black button until the word
“GO OFF” shows up. Then immediately
release the black button. If one waits for
too long to release the black button, the
28
dosimeter will not switch off).
Underground Cavern Access
D
C
entral
S
15. Click on edit button
16. The WP summary page will appear
17. In the list of name click on edit
16
15
17
29
Underground Cavern Access
18.
19.
20.
21.
D
C
entral
S
Insert the name of the person you want to register (previously authorized by the WP leader)
Select his role
save changes
The new name will appear in the name list
19
18
9
21
20
30
Underground Cavern Access
D
C
entral
S
Once the authorized person has received his dosimeter (s)he can finally access to the cavern,
and in the two displays here below the DCS Shifter can check all the cameras pointing at the
different doors in the cavern : When the person reach the entrance (21) there are still few steps
to be execute …
21
Underground Cavern Access
The name will appear here ….
23
22
25
D
C
entral
S
… he needs to pass his badge
over the card reader in the
yellow underground cabinet
(22) : Then on the DCS
screen his name will appear
in the dedicated window (23
and the DCS Shifter has first
to select the line and then
click the button “Give the
Key” (24) in order to let the
drawer in the underground
rack opening (25) and
delivering the access key to
him.
24
Once selected the name the button will became clickable
DCS Elog
D
C
entral
S
DCS ELOG address :
cmsonline > Common > Elog > Subsystems > DCS
 At the beginning the shift: write an elog with the summary
status of all the central DCS systems;
During your shift : Write only a short elog with specific
information when you have any problem with subdetectors,
cooling, racks, etc... with indication on your elog Title of the
problem
At the end of the shift: Write an elog with a summary of all the
relevant events that happened during your shift.
 Shift Instructions are available online at:
https://twiki.cern.ch/twiki/bin/view/CMS/OnlineWBCentralDCSIn
structions
33
Useful Contacts (1)
• Emergency, accident, fire : 74444
•Any technical problem (Siren Alarm): 165000
• Rack Problem :
Rack becomes off or in error :
1. Tracker (Pixel) : 165502
2. Tracker (Strip) : 165503
3. ECAL : 70130 or 165504
4. HCAL : 165505,
5. CSC :165509
6. DT : 165507
7. RPC :165508
During the day you can also call Silverio : 163706
• Cooling Problem :
1. ECAL cooling: 70130/165504
2. One (other the ECAL) of the box is not green :
 During the day : Cooling piquet 163021
 Outside working hours :
• Top part : call CCC 72201
• Bottom part : call 165000 if red
• Screen blinking : Call CCC 72201
D
C
entral
S
Magnet Problem : Call Magnet piquet 162082
• Cryogenic problem : Call Cryogenic piquet 160124
• Gaz Problem : Call Gaz Piquet 162516
• DCS Problem:
• Central DCS :Call DCS expert on call 162229
• Subdetector DCS :
1. Tracker (Pixel) : 165502
2. Tracker (Strip) : 165503
3. ECAL :72606 or 165504
4. HCAL : 165505,
5. CSC :165509
6. DT : 165507
7. RPC :165508
• DSS Problem :
• Alarm :
Alain Meynet during the day 163146
Christoph Schaefer 160202
• Technical Problem : 165000
• Hardware Problem : 162082
Useful Contacts (2)
TS Technical control room (CCC): 72201
IN CASE OF ANY TECHNICAL PROBLEM CALL: 16 5000
Backup: Austin BALL: 160408, Christoph SCHAEFER:160202, Wolfram
ZEUNER: 162541, Martin GASTAL: 163702
DCS expert on call : 16 2229
Backup : Frank : 163919, Bobby : 162366, Lorenzo : 165820
DSS expert on call : 162082
CASTOR: 162875
TOTEM (Green Barrack): 77534
BRM/BCM: 165501
Fireman at P5 (working hours ) : 164812
(still call directly the 74444 in case of DSS alarms)
Online Web Contact List :
https://twiki.cern.ch/twiki/bin/viewauth/CMS/OnlineWBContactList
D
C
entral
S