Refrigeration Lab Notice
Lab notice:
The lab sessions have been arranged on 12/4 and 12/9 in Eng. Building One at R322
Please come to the lab session at your assigned group
Lab report is due one week after the lab session. Please submit it by e-mail via
brianwang13582@gmail.com and cc to cyhuang@pme.nthu.edu.tw
Lab report submission
*********************************************
Everyone should submit his/her lab report individually. No plagiarism is tolerated. If similar
words, sentences, or paragraphs have been identified in the lab report, at least 50% penalty
will be applied to the score.
*********************************************
TA video
A short video of Lab Intro recorded by the TA is available at the following link
https://www.dropbox.com/scl/fi/xhexvich4qsoz229j9xyk/Refrig-LabIntro.mp4?rlkey=3x0wjj297x306xtrzwkob9rcd&dl=0
Attendance policy
1. You must participate full-time in the assigned lab session.
2. The experiment data could be the same for each group in the same lab session.
1
Refrigeration Lab Notice
Experiment content
๏ฌ During the experiment, students will be asked to record experimental data, calculate the
Coefficient of Performance (COP), and create pressure-enthalpy (p-h) diagrams, among
other tasks. Please make sure to read the experiment handout and watch TA video in
advance.
๏ฌ The report should include the followings.
1. Experiment content and experiment goal. (15%)
2. Describe the refrigeration vapor cycle in words or by picture, including four
components, the fluid flow, heat flow and the experiment theory. (30%)
3. Based on the experiment data in appendix, use software TLK Energy and the R134a
property table to draw ๐๐ − โ diagram (all kinds of drawing software is allowed)
(15%)
๏ฌ link: TLK Energy
๏ฎ https://tlk-energy.de/en/phase-diagrams/pressure-enthalpy
4. Explain the definition of COP. (15%)
5.
Describe how do you solve (๐๐, ๐ ๐ , โ and ๐๐) based on the measured data. (25%)
2
Refrigeration Lab Notice
3
Refrigeration Lab Notice
Experimental Procedure:
Open valve V1, and close valves V2 and V3. After the refrigerant condenses in
the condenser, it becomes a liquid. The liquid refrigerant flows directly through
the dryer filter and expansion valve. It then enters the evaporator. (TA demo)
Record the data at the following table.
Temperature (โ)
Pressure (bar)
Compressor refrigerant outlet (1)
Condenser refrigerant outlet (2)
Expansion valve refrigerant outlet (3)
Evaporator refrigerant outlet (4)
Evaporator air inlet (TA)
Evaporator air outlet (TB)
Condenser air inlet (TC)
Condenser air outlet (TD)
Calculate COPR, CarnotใCOPR, idealใCOPR based on the Reversed Carnot Cycle.
where h4 = hg @ P4 and h2 = hf @ P2 and โ2 = โ3
4