Lecture 1
The Evolution of Automation in Industry
In this session, you will be introduced to:
1
History of Industry Revolutions
2
Objective of Industrial Automation
3
Common actuation methods in Industrial
Automation
4
Use of Pneumatics in Industrial
Automation
5
Definition of Pneumatics
6
Use of Pneumatics in Industrial Automation
7
Area of Use and Applications of Pneumatics
2
History of Industry Revolutions
Before the 1st Industry revolution
◎
Prior to 1st Industry Revolution, most people
produce their good at home.
◎
This phase was commonly known as Agrarian or
Handicraft economy.
◎
Raw materials and final products were
transacted in their residence. People plan their
schedule and resources.
◎
The concept of machines was not common.
3
History of Industry Revolutions
Summary of 1st Industry revolution
◎
The first Industry revolution started
approximately mid of 1700s to 1800s.
◎
Discovery of Steam Powered Engine is one of
the key drivers in this Industry Revolution.
◎
Development of machines become more
common.
◎
Human productivity is improved.
4
History of Industry Revolutions
Summary of 2nd Industry revolution
◎
The first Industry revolution started
approximately mid of 1800s to mid of 1900s.
◎
Discovery of Electricity is one of the key drivers
in this Industry Revolution.
◎
The concept of Mass Production become
common. Henry Ford Assembly line is one of the
well known example.
◎
Products can be manufactured at a significantly
faster and lower cost.
5
History of Industry Revolutions
Summary of 3rd Industry revolution
◎
The first Industry revolution started
approximately mid of 1900s.
◎
Deployment of computers into manufacturing is
one of the key drivers in this Industry
Revolution.
◎
The concept of Automation become common.
Most of the production work can be automated.
◎
Introduction of Robots has also replaced human
intervention.
6
History of Industry Revolutions
Summary of 4th Industry revolution
◎
We are currently in the midst of the 4th Industry
Revolution.
◎
Networking technologies between robots and
machines is one of the key drivers.
◎
Networking of all systems leads to a Cyber
Physical System.
◎
Management, supervisory and field staff can
collaborate at much higher efficiency.
7
History of Industry Revolutions
Mid 18th
Century
Mid 19th
Century
Late 20th
Century
Now
…
8
“
What do you think cause
each Industry Revolution
to happen?
Revealing at the last lecture of the semester…
9
Objective of Industrial Automation
Usage of technologies to
◎
Effective and Efficient use of energy
◎
Enable efficient repetition of tasks under well
defined parameters with minimum supervision
◎
Enhance communication in workflow
◎
Ensure standardisation of work practice
10
Objective of Industrial Automation
Improving
◎
Productivity by either supplementing,
complementing or replacing human intervention
◎
Quality of end products through process
standardisation
◎
Error reduction through human fatigue or lapses
◎
Safety by mitigation or replacement of
hazardous work
◎
Flexibility in switching to other tasks
11
“
How can we cope with the
jobs replaced by Industrial
Automation?
Revealing at the last lecture of the semester…
12
Common actuation methods in Industrial Automation
1. Pneumatics
2. Hydraulics
3. Electrical
4. Manual
Or hybrid of any of the above.
13
Common Actuation methods in Industrial Automation
Characteristics
Pneumatic
Hydraulic
Electric
Complexity
Simple system composition
Moderately complex system composition
Control systems and motion components can
work together in multiple complex
configurations
Peak Power
High
Very high
High
Control
Simple valves
Simple valves
Flexibility of motion control capabilities with
electronic controller
Position
Accuracy
Very difficult to achieve position accuracy
Mid-stroke positioning requires additional
components and user support
Positioning capabilities and velocity control
allow for synchronization
Speed
Very high
Moderate
Moderate
Load Ratings
High
Very high
Can be high depending on the speed and
positioning desired
Lifetime
Moderate
Long
Long
Acceleration
Very high
Very high
Moderate
Shock Loads
Able to handle shock loads
Explosion-proof, shock-proof, and sparkproof
Limited ability to handle shock loads
Environmental
High noise levels
Hydraulic fluid leaks and disposal
Minimal
Utilities
Compressor. power, pipes
Pump, power, pipes
Power only option
Efficiency
Low
Low
High
Reliability
Excellent
Good
Good
Maintenance
High user-maintenance
High user-maintenance
Little to no maintenance
Low
High
High
Operating Cost
Moderate
High
Low
Maintenance Cost
Low
High
Low
Purchase Cost
Covered mainly in this module
14
Credit to Timotion
Definition of Pneumatics
Is the science which deals with the study of
air, its properties and applications at
pressure higher (Compressed air) or lower
(Vacuum) than atmosphere.
o
Greek word “pneuma” means breath
o
Pneumatic - use of compressed air in drive and
control engineering
o
Electro-pneumatics
- integration
of pneumatic
electrical
technologies
and
o
Where signals are transmitted over great
distances in a control system, the time
between signal transmission and signal
reception is minimized using electricity as the
15
transmission medium
Use of Pneumatics in Industrial Automation.
The principle of pneumatics works as the
following:
1. Compressing air from the environment and
storing the pressurized air into a tank
(commonly known as the receiver).
2. Channelling the pressurized air through
pipes and valves to achieve the required
motion and action.
3. Compressor continues to pump in the air
to maintain the required pressure in the
system.
16
Use of Pneumatics in Industrial Automation.
◎
Air is readily available medium available
in unlimited quantities almost
everywhere.
◎
Using air as a medium, pneumatics does
not face the risk of fire or explosion in
flammable environment.
◎
Compressed air can be transported easily
through pipes.
◎
Releasing compressed air to the
environment can be done without any
further processing.
◎
Pneumatic system components are
relatively inexpensive.
17
Use of Pneumatics in Industrial Automation.
◎
Compressing air is an expensive
process.
○
◎
Compressed air will not provide an
uniform and constant piston speed.
○
◎
However, this high cost is usually attenuated by
lower wages, installation, and maintenance
costs as compared to other actuation methods
The reduction is speed and pressure is more
apparent over longer distances and larger
systems.
Releasing compressed air back to the
environment can be loud and high pitched
(above 110 decibels).
○ The noise is usually mitigated by the use of
pneumatic silencers
18
Use of Pneumatics in Industrial Automation.
Positive
Negative
o
Availability
o
Preparation
o
Transport
o
Compressible
o
Storage
o
o
Temperature
Force
requirement
o
Explosion proof
o
Exhaust air
o
Cleanliness
o
Costs
o
Components
o
Speed
o
Adjustable
o
Overload safe
* Refer to detailed notes for further
explanation
19
“
Are you able to think of any other
advantages of Pneumatic
components?
20
A brief history of Pneumatics components
One of the earliest known application of pneumatics: Fireplace
bellow
1
21
A brief history of Pneumatics components
One of the earliest known air compressor: Kolbenluftpumpe
2
22
A brief history of Pneumatics components
The current generation of Air Compressor
3
23
Area of Use and Applications of Pneumatics
◎ Compressed air can be found in
almost all fields of engineering
•
•
•
•
•
•
•
Rail transport: Train doors
Aeroplanes:
Landing Wheels
Vehicles: Bus doors
Mining: Cutting tools and equipment
Construction: loading and unloading
equipment
Medical technology: Packing of
medication
Defence: Repair tools
24
Area of Use and Applications of Pneumatics
◎ Application Areas
o Generations of linear motion
o Clamping tools, feed units, lifting and lowering,
etc.
o Generations of rotary motion
o Screw drivers, grinders, drills, etc.
o Applications in control
o Sequence controls, monitoring, counting, etc.
25
“
Additional reading materials
26
Additional Details on Positive Characteristics of
Compressed Air
Cleanliness:
Un-lubricated exhaust air is clean. Any un-lubricated air which escapes
through leaking pipes or components does not cause contamination. This is
an important point when considering the food, wood and textile industries.
Components:
The operating components are of simple construction and are therefore
relatively inexpensive.
Speed:
Compressed air is a very fast working medium. This enables high working
speeds to be attained.
Adjustable:
With compressed air components, speeds and forces are indefinitely
variable.
Overload Safe:
Pneumatic tools and operating components can be loaded to the point of
stopping and are therefore overload safe
27
Additional Details on Negativity Characteristics of
Compressed Air
Availability:
Air is available practically everywhere in unlimited quantities.
Transport:
Air can be easily transported in pipelines, even over large
distances.
Storage:
A compressor need not be in continuous operation. Compressed air can
be stored in a reservoir and removed as required. In addition, the
reservoir can be transportable.
Explosion proof:
Compressed air offers minimal risk of explosion or fire, hence no
expensive protection against explosion is required
28
Lecture 2
Air treatment and distribution for Pneumatic
Systems
In this session, you will be introduced to:
1
Atmospheric air to compressed air
2
Identification of Compressed Air
Contamination
3
Compressed Air Preparation
4
Main types of Compressor
7
Functions of an Air Filter
5
Methods of Reducing Moisture Content in
Air
8
Functions of an Air Regulator
6
Functions of an Air Receiver
9
Compressed Air distribution
2
Atmospheric air to Compressed Air
◎
◎
◎
Composition of atmospheric air is about 78% Nitrogen,
21% Oxygen and 0.9% Argon. The remaining 0.1%
consists of Carbon Dioxide, Water vapour and other
gases.
The quantity and composition of dust particles affects
the efficiency of the pneumatic system.
Compressed air needs to be treated so that it can be
effectively used in a pneumatics system.
◎ Clean compressed air can enhance the integrity
and longevity of the component in the systems.
Wat
er
Vap
or
Oil
78% N,
21% O,
0.9% Ne,
Others
Dust
3
How to identify Compressed Air Contamination and Its
Sources
https://www.youtube.com/watch?v=saHXJWoNkxE
4
How to identify Contamination in Compressed Air
◎
Contamination in the form of dirt or rust particles,
excess lubricant and humidity often lead to
disturbances in pneumatic equipment and damage to
pneumatic components.
o Rapid wear of seals and moving parts in the cylinders
and valves.
o Oiled-up valves
Contaminated
silencers
◎ oWater
(moisture)
is introduced to the air network with
the air drawn in by the compressor
o The amount depends primarily on the relative humidity which in
turn is dependent on the air temperature and the weather
conditions.
o Water produces a hardening of seals, corrosion and the washing-out
of the original lubrication of cylinders
o Oil and water may cause seals and diaphragms to swell.
5
Compressed Air Preparation
◎ The equipment used in the
generation and preparation of
air
include:
o
o
o
o
o
o
o
Air compressor
Air receiver
Air dryer
Air filter
Air lubricator
Pressure regulator
Distribution and drainage points
6
Main Types of Compressor
Types of Compressor
Reciprocating
Piston
Compressor
Rotary screw
Compressor
7
Centrifugal
Compressor
Main Types of Compressor
Rotary screw type
compressor
* Refer to detailed notes for further
explanation
8
Main Types of Compressor
Reciprocating Piston Compressor
* Refer to detailed notes for further
explanation
9
Main Types of Compressor
Centrifugal air compressor
* Refer to detailed notes for further
explanation
10
Methods of Reducing Moisture Content in Air
◎ Compressed air should be dried using the necessary air
drying equipment to reduce the moisture contents to a level
which suits the application and the elements used
◎ Three auxiliary methods of reducing the moisture content in
the air:
o Absorption drying
o Adsorption drying
o Low temperature drying
11
Methods of Reducing Moisture Content in Air
Pn eum ati cs
Ai r out
Ai r in
Re frigerant
Fest o Did act ic
Re frigerati ng mac hine
He at e xcha nger
Air drying , lo w tem perat ure
Separator
Re frigerati ng uni t
Pn eum ati cs
Fest o Did act ic
He at e xcha nger
Ai r out
Ai r in
Re frigerati ng uni t
Re frigerant
Separato r
Re frigerati ng mac hine
Air drying , lo w tem perat ure
P
n
eu
m
at
i
cs
F
est
H
e
R
e
f
r ig
e
r a
t
i
n
g
u
n
i
a
t
e
x
c
h
a
n
g e
r
A
i
r o u
t
A
i
r in
o
D id
act
ic
t
R
e
R
e
f
r ig
e
r a
n t
f
r ig
e
r a
t
i
n
g
m
a
c
h
in e
* Refer to detailed notes for further explanation
S
e
p a
r a
t
o r
A ir
dr y i ng
,
lo
w
te m
pe r
a t
12
ur e
Methods of Reducing Moisture Content in Air
Ai r out
Ai r in
Fest o Did act ic
Air drying , lo w tem perat ure
Separato r
Re frigerati ng mac hine
Re frigerant
Re frigerati ng uni t
Ai r in
He at e xcha nger
Pn eum ati cs
13
Re frigerant
Ai r out
Fest o Did act ic
C
C
o
o n
n
d
de
e
n
n
s
sa
a
te
t
e d
d
rr
a
a
in
in
A
A
ir
ir
dr
dr
y
y
i ng
i ng
:: A
A
bs
bsor
or pti
pti o
on
n
Re frigerati ng mac hine
C
C
o
o
n
n
d
d
e
e
n
n
s
s
aa
te
t
e
M
o
is
M
o
t is
air
t a
in
ir li
e
n
t let
He at e xcha nger
ic
F
F
lu
lu
x
x
Pn eum ati cs
Air drying , lo w tem perat ure
Fe
F
s
e
t
s
o
t o
D id
D id
ac
a
t c
ic
t
D
D
rr
y
y
a
a
ir
ir
o
o
u
u
t
tle
le
t
t
Separator
cs
Re frigerati ng uni t
P
n eP
u
n
m
e
a
u
t
m
i c
a
s
ti
A ir
dr y i ng :
A ds or pti o n
D
r y a ir
14
Air drying , lo w tem perat ure
H
o t a ir
o D id act
Fest o Did act ic
F
est
Ai r in
f
il
Ai r out
Oil
Re frigerant
valv e
Re frigerati ng mac hine
S
h u
t
- o
f
f
He at e xcha nger
cs
Separator
A
d so r
b er
1
Re frigerati ng uni t
P
n eu
m ati
Pn eum ati cs
Ai r in
Ai r out
Fest o Did act ic
Re frigerati ng mac hine
Re frigerant
He at e xcha nger
Air drying , lo w tem perat ure
Separator
Re frigerati ng uni t
Pn eum ati cs
Methods of Reducing Moisture Content in Air
M
o
is t air
t
er
A
d so r
b er
2
ic
H
e at
er
Functions of an Air Receiver
Pressure relief valve
Pressure
gauge
Temperature
gauge
Shut off
valve
gauge
Compressor
Air receiver
15
Water drain
Functions of an Air Receiver
◎
Provides constant air pressure in a
pneumatic system, regardless of
varying or fluctuating consumption
o Enables briefly-occurring consumption peaks
to be balanced out, which cannot be made up
by the compressor.
◎
Acts as an emergency supply to the
system in cases of power failure.
o Reservoir can be fitted either downstream of the compressor, to act as
an air chamber, or selectively at points where consumption is high.
◎
Large surface area of the receiver cools
the
air
o
A portion
of the moisture in the air is separated directly from the
receiver as water.
o Important to drain the condensate regularly
16
Pn eum ati cs
He at e xcha nger
Fest o Did act ic
Pn eum ati cs
Ai r out
17
Compressed air filter
Fest o Did act ic
He at e xcha nger
Ai r in
Pn eum ati cs
Ai r out
He at e xcha nger
Ai r in
Re frigerati ng uni t
Fest o Did act ic
Ai r out
Ai r in
Re frigerati ng uni t
Re frigerati ng uni t
Re frigerant
Re frigerant
Re frigerati ng mac hine
Re frigerant
Re frigerati ng mac hine
Air drying , lo w tem perat ure
Air drying , lo w tem perat ure
Separato r
Separato r
Re frigerati ng mac hine
Separato r
Air drying , lo w tem perat ure
◎
Pneumatics
Festo Didactic
Used to remove solid and liquid
impurities
Functions of an Air Filter
Functions of an Air Filter
◎
Used to remove solid and liquid
impurities
18
Pn eum ati cs
He at e xcha nger
19
Air lu b ric ato r
Pn eum ati cs
Fest o Did act ic
Ai r out
He at e xcha nger
Fest o Did act ic
Ai r out
Ai r in
Ai r in
Re frigerati ng uni t
Re frigerati ng uni t
Re frigerant
Re frigerant
Re frigerati ng mac hine
Separator
Re frigerati ng mac hine
Separator
Air drying , lo w tem perat ure
Air drying , lo w tem perat ure
◎
Pneum at i c s
Fe st oD id a ct ic
Used to lubricate control devices and
actuators
Functions of Air Lubricator
Functions of Air Lubricator
◎
Used to lubricate control devices and
actuators
20
Principle of Pressure
Converted units
N/m2
Pa
Equal
N/m2
psi
bar
atm
Divide by
6895
Divide by
1 X 10 5
Divide by
101325
Divide by
14.5
Divide by
14.7
Equal
Pa
Base
unit
psi
Multiply by
6895
bar
Multiply by
1 X 10 5
Multiply by
14.5
atm
Multiply by
101325
Multiply by
14.7
Divide by
1.013
Multiply by
1.013
21
Principle of Pressure
Pressure = Force / Area
◎ Unit of Pressure
o Newtons per meter square ( N/m2 )
o Pascal (Pa)
o Pounds per Square inch ( psi)
o Bar (bar)
o Standard Atmosphere (atm)
22
Definitions of Gauge Pressure & Absolute
Pressure
kPa (bar/psi)
+pg
Gauge Pressure range
Fluctuating
atmospheric
pressure
Absolute
vacuum
0
pab
Absolute
pressure
Pat approx. 1
bar
-p
v Vacuum
range
Air Pressure relationship
23
Functions of Air Pressure Regulator
◎
Used to keep the pressure in the equipment constant
◎
A regulator can reduce, but not increase the working
Pneum
at i c sat i c s
Fe st oFe
D st
id oa D
ct id
c a ct ic
Pneum
pressure
Air drying , lo w tem perat ure
Separator
Re frigerati ng mac hine
Re frigerant
Re frigerati ng uni t
Ai r in
He at e xcha nger
Pn eum ati cs
Air Air
su psu
p ly:
susresure
p p Ply:rePsre
re gurelagutolar to r
withwith
v e nv tehnotle
h o le
24
Ai r out
Fest o Did act ic
Functions of Air Pressure Regulator
◎
Used to keep the pressure in the equipment constant
◎
A regulator can reduce, but not increase the working
pressure
25
Functions of an Air Service Unit
◎
Combination of the three elements: Air Filter, Air Pressure Regulator
and Air Lubricator
Pneumati cs
Fest o Didact ic
Compressed air service unit
26
Functions of an Air Service Unit
◎
Combination of the three elements: Air Filter, Air Pressure Regulator
and Air Lubricator
27
Functions of an Air Service Unit
P
n eum ati
Sup
cs
Fest o D id act ic
ply
Air r e
c eiv
er and
'T' junc
t ion
C
ompr e
ss
or
Se rv
i ce
e
q uipme nt
W
a ter
Filter
se
par a
t o
r
2
Pr e
ss
ur e
r
egula
t or
L
ubr ic
ator
1
3
Sy m b ol s
of e ne r gy
a nd s u ppl y
c om p one nt s :
Sup pl y
a nd s e r v i ce
e qu i pm e nt
P
n
eu
m
at
i
cs
F
est
P
r e
s s
ur e
A
ir
s e
rv
i
Sy m b
o
D id
act
ic
s
our c
e
c
e
u n it
ol s
of
e ne r gy
a nd
s u ppl y
c om p
C om bi n e
d
s y
m
bol s
one nt
s :
Pn eum ati cs
Fest o D id act ic
Sup ply
Air r ec eiver and
'T' junct ion
Compr es sor
Servi ce eq uipment
W
ater s epar at or
Filter
2
Pr es sur e
regulat or
Lubr icator
1
3
Sy mb ols of e ne r gy a nd s u pply c omp one nt s :
Fest o D id act ic
Sup ply a nd s e r v ice e qu ipme nt
Pn eum ati cs
Pr es sur e sour ce
Air s ervi ce unit
Sy mb ols of e ne r gy a nd s u pply c omp one nt s :
Combin ed s ym bols
28
Compressed Air Distribution
◎
◎
Despite the best water separation in
the pressure generating system,
pressure drops, and external cooling
may produce condensate in the pipe
system. In order to discharge this
condensate, the pipes should be
inclined 1 - 2%
The condensate can then be
discharged from the system via
water separators at the lowest point
Pneum atics
Festo D idactic
Interm ediate reservoir
Reservoir within a pneum atic system
Air reservoir
Service unit
1-2% gradient
Consum ing
devices
Com pressor
C ondensate
collector tank
Com pressed air supply: Delivery
29
“
Additional reading materials
30
Recap Questions
List the various type of air compressor
for generating compressed air
o Reciprocating piston compressors
o Rotary screw compressors
o Centrifugal compressors
Name the functions of an air receiver used in a
pneumatic system
o Provides constant air pressure in a pneumatic system,
regardless of varying or fluctuating consumption
o Acts as an emergency supply to the system in cases of power
failure
o Large surface area of the receiver cools the air
31
Recap Questions
List the type of damage to pneumatic
components caused by contaminants
o Rapid wear of seals and moving parts in
the cylinders and valves
o Oiled-up valves
o Contaminated silencers
List remedial measures to reduce contamination in
pneumatic
o
Filtering ofcomponents
the air at the compressor intake
o Use of an oil-free compressor
o Compressed air should be dried using the necessary air-drying
equipment
32
Recap Questions
◎
Name the methods of reducing the
moisture content in compressed air
o Low temperature drying
o Adsorption drying
o Absorption drying
◎
Why air pipes are usually installed with a gradient
downwards?
o To allow condensate from the compressed air to easily flow to
water separators at the lowest point and be discharged from the
system
Draw the pneumatic symbol for the air service unit
Pn eum ati cs
Fest o Did act ic
Pres sure source
Air s ervi ce unit
Symb ols of ener gy and su pply comp onent s:
Combin ed sym bols
33
Additional Details on Drying Methods
◎
Low temperature drying
◎
o This method cools the air to its dew point temperature (2
to 5 deg C) to condense water vapour contained in the
compressed air.
o Before the compressed air is output into the network, the
air is heateddrying
back to ambient temperature.
Adsorption
◎
o This method uses drying materials which remove water vapour from the
air
[Adsorb: water deposited on the surface of solids].
o The drying agent (almost entirely of silicon dioxide) is a granular material
of sharp-edged shape or in bead form.
o In practice, two tanks are used; when the gel in one tank is saturated, the
air flow is switched
Absorption
dryingto the dry, second tank and the first tank is
regenerated by hot-air drying.
o This is a purely chemical process.
o The moisture in the compressed air forms a compound with the drying
agent in the tank.
o It is then discharged in the form of a fluid at the base of the tank.
34
Additional Details on Types of Compressor
Preparation:
Compressed air needs good preparation.
Dirt and humidity may be present causing the wearing of pneumatic
components.
Compressible:
It is not possible to achieve uniform and constant piston speeds with
compressed air.
Force Requirement:
Compressed air is economical only up to a certain force requirement. Under
the normally prevailing working pressure of 700 kPa (7 bar/101.5 psi) and
dependent on the travel and speed, the limit is between 20000 and 30000
N.
Exhaust Air:
The exhaust air is loud. This problem has now, however, been largely
solved due to the development of sound absorption material.
Overload Safe:
Compressed air is a relatively expensive means of conveying power. The
high energy costs are however partially compensated by inexpensive
components and higher performance
35
Lecture 3
Introduction To Pneumatic Component and
Symbolic Representations, Part 1
In this session, you will be introduced to:
1
Types of pneumatic cylinder
2
Calculations for sizing of cylinders
3
Specifying & describing directional control valves
4
Different types of pneumatic valves, its design characteristics and symbolic
representation
5 Energy & supply components and their symbols
6
Distribution of compressed air
2
History of Pneumatics: Pneumatic Tubes
https://www.youtube.com/watch?v=sd58w0CXQrM
3
Pneumatic Cylinders
◎ Single Acting Cylinder
○
Compressed air exerts a force in one
direction
○
Force in the other direction comes from
a spring or an external force
◎ Features
○
Air required for only one direction of
movement
○
Limited stroke (max about 150mm)
○
High speed return (no load on return)
4
Types of Single Acting Cylinders
Symbol of Normally
Retracted
Single Acting Cylinder
Symbol of Normally
Extended
Single Acting Cylinder
5
Pneumatic Cylinders
◎ Double Acting Cylinder
◎ Force is exerted in both
directions by compressed air
◎ Features
○
Forward forces exist in both
directions
○
Work can be done on both advance
and
○
Return stroke
○
In principle , the stroke length is
unlimited
6
Double-Acting Cylinders
Symbol of Double-Acting
Cylinder
7
Other Pneumatic Cylinders
Bellows Cylinder
○ These have no moving parts and maintenance
free
○ Stroke is limited
8
Air Springs – Air Bellows – Bellows Cylinders – Bellows Actuator
https://www.youtube.com/watch?v=qM-dNITnU3o
9
Other Pneumatic Cylinders
Cylinder with Piston Rod Brake
○ A mechanical brake can be used to stop a piston in a stable
intermediate position.
○ Used for security reasons, whenever a cylinder has to be held in a
stable position.
10
Other Pneumatic Cylinders
Double Acting Cylinder with Double
Piston Rod
○ Used when equal forces are required in both
directions.
11
Other Pneumatic Cylinders
Pn eum ati cs
Pn eum ati cs
Fest o Did act ic
Fest o Did act ic
Semi - rotary actu ator
Semi - rotary actuator
Rotary Drives or Actuators
○ Devices which transform pneumatic energy into mechanical rotary
movement
12
Pneumatic Actuators Rotary
https://www.youtube.com/watch?v=dizRZSw-QLQ
13
New Pneumatic Inventions
14
Calculations for Sizing of a Cylinder
Example
Question 1
A double-acting cylinder of 50mm diameter is
to be selected for an application. A working
pressure of 6 Bar is used to actuate the
cylinder.
A 10% frictional resistance is to be taken into
account during the operation of the cylinder.
Calculate the theoretical piston force exerted by the cylinder
during the extend and return stroke.
Show all workings and formulas used and leave your final
answer to two decimal places in Newton (N).
15
Calculations for Sizing of a Cylinder
Solution
◎ Convert 6 bars to Pa (or N/m2)
Pressure [P] = 6 bar
= 600 kPa
= 6 x 105
N/m2
16
Calculations for Sizing of a Cylinder
Solution
◎
Calculations for extend stroke
Formula: Pressure = Force/Area
Force = Area. Pressure
Theoretical piston forward force = Aout . P
Fout
= 1.963 x 10-3 x 6 x 105
= 1177.8 N
Frictional force [Ff] = 10% (assumed)
Effective piston forward force
= Aout . P
D = 50 mm
= 0.05 m
Aout
= 3.142 D2/4
= 1.963 x 10-3 m2
= 1.963 x 10-3 x 6 x 105 x (100-10)
%
17
Calculations for Sizing of a Cylinder
Solution
◎
Calculations for retract stroke
Formula: Pressure = Force/Area
Force = Area. Pressure
Theoretical piston return force = Ain. P
= 1.85 x 10 x 6 x 10
-3
= 1110 N
Frictional force [Ff] = 10% (assumed)
Effective piston return force
= Ain . P
Fin
5
d = 12 mm = 0.012m
Ain3.142(D2/4 - d2/4)
=
= 1.963 x 10-3 - 1.13 x 10-4 m2
= 1.85 x 10-3 m2
= 1.85 x 10-3 x 6 x 105 x (100 –
10) %
18
Calculations for Sizing of a Cylinder
Example Question 2
A working pressure of 5 Bar is used to
actuate a double-acting cylinder.
Calculate the diameter of the piston and cylinder rod if the
piston force exerted by the cylinder during the extended stroke is
1000 N and retracted force is 800N.
19
Calculations for Sizing of a Cylinder
Solution
Pressure [P] = 5 bar
= 5 x 105
N/m2
Piston forward force = Aout . P
Piston
1000 = (Л x D2 / 4 ) x (5 x 105)
D2 = 0.002546479089
D
= 0.05046265 m
= 50.46 mm
Cylinder Rod
The diameter of the piston needs to be minimum of 50.46mm to achieve a forward force of
1000N .
20
Calculations for Sizing of a Cylinder
Solution
Pressure [P] = 5 bar
= 5 x 105
N/m2
Piston forward force = Aout . P
Piston
1000 = (Л x D2 / 4 ) x (5 x 105)
D2 = 0.002546479089
D
= 0.05046265 m
= 50.46 mm
Cylinder Rod
The diameter of the piston needs to be minimum of 50.46mm to achieve a forward force of
1000N .
21
Calculations for Sizing of a Cylinder
Solution
Pressure [P] = 5 bar
= 5 x 105
N/m2
Piston forward force = Aout . P
Piston
1000 = (Л x D2 / 4 ) x (5 x 105)
D2 = 0.002546479089
D
= 0.05046265 m
= 50.46 mm
Cylinder Rod
The diameter of the piston needs to be minimum of 50.46mm to achieve a forward force of
1000N .
22
Calculations for Sizing of a Cylinder
Solution
Pressure [P] = 5 bar
= 5 x 105
N/m2
Piston retracted force = Ain . P
Piston
800 = (Л x {D2 - d2 }/ 4 ) x (5 x 105)
800 = (Л x {0.05046265 2 - d2 }/ 4 ) x
d2 = 0.000509248
(5 x 105)
d
= 0.022566 m
= 22.57 mm
Cylinder Rod
The diameter of the piston needs to be maximum of 22.57 mm to be able to achieve a retract force of
800N .
23
“
Additional reading materials
24
Recap Questions
◎
List the main features of single-acting
cylinder
o Air required for only one direction of movement
o Limited stroke (max about 150mm)
o High speed return (no load on return)
◎
Draw the symbol of a Normally Retracted and Normally Extended
single-acting cylinder
25
Recap Questions
◎
List the main features of single-acting
cylinder
o Air required for only one direction of movement
o Limited stroke (max about 150mm)
o High speed return (no load on return)
◎
Draw the symbol of a Normally Retracted and Normally Extended
single-acting cylinder
26
Recap Questions
◎
List the main features of single-acting
cylinder
o Air required for only one direction of movement
o Limited stroke (max about 150mm)
o High speed return (no load on return)
◎
Draw the symbol of a Normally Retracted and Normally Extended
single-acting cylinder
27
Recap Questions
◎
List the main features of double-acting
cylinder
o Forward forces exist in both directions
o Work can be done on both advance and return stroke
o In principle, the stroke length is unlimited
◎
Draw the symbol of a double-acting cylinder
28
Directional Control Valves
◎
Control start, stop and direction of flow of the
compressed air
Pn eum ati cs
Fest o Did act ic
Pn eum ati cs
Fest o Did act ic
2
3
1
3
2
4
1
1
2
3
4 / 2 w ay valve, disc seat , u nactuat ed
3 / 2 w ay valve, ball seat , unactuat ed
29
4
2
1
3
Directional Control Valves
◎
Symbol
Development
30
Directional Control Valves
◎
Symbol
Development
31
Directional Control Valves
◎
Symbol
Development
32
Specification of a Directional Control Valve
◎ Number of ports
◎ Number of switching positions
◎ Type of initial position
◎ Type of actuation & return
* Refer to detailed notes for descriptions
of other valve symbols
33
Describing Methods of Actuation/ Return
34
Describing Methods of Actuation/ Return
35
Some Examples of Valve Symbols
01
Quick exhaust
valve
02
03
4/3 directional control
valve, closed mid-position,
centered by springs, with
double solenoid actuation
36
4/2 directional control
valve, normally open,
double air actuation
Some Examples of Valve Symbols
01
Quick exhaust
valve
02
03
4/3 directional control
valve, closed mid-position,
centered by springs, with
double solenoid actuation
37
4/2 directional control
valve, normally open,
double air actuation
Some Examples of Valve Symbols
04
05
06
5/2 directional control
3/2 directional control
valve, normally open, with valve, normally open, roller
double solenoid actuation actuated, spring return
38
3/2 directional control
valve, normally close, air
piloted spring return
Some Examples of Valve Symbols
07
4/2 directional control
valve, normally open,
pedal with detent
08
09
5/3 directional control
valve, spring-centered,
closed mid-position, air
piloted
39
3/2 directional control
valve, normally open,
actuated by a plunger
Lecture 4
Introduction To Pneumatic Component and
Symbolic Representations, Part 2
In this session, you will be introduced to:
Different types of pneumatic valves,
its design characteristics and symbolic
representation
Diagrammatic representation of
2
pneumatic circuit diagrams
1
2
Non-Return Valves
◎
◎
◎
Are devices which preferentially stop
the flow in one direction and permit
flow in the opposite direction.
The pressure on the downstream side
acts against the restrictive
component, thereby assisting the
sealing effect of the valve
They are constructed with or without
springs
Check valve
Spring
Loaded
Check Valve
3
Check valves
Pn eum ati cs
◎
◎
Can stop the flow completely in one
direction, and the air flows in the
opposite direction with as low as a
pressure loss as possible.
Blocking of the one direction can be
effected by cones, balls, plates or
diaphragms.
Pn eum ati cs
Fest o Did act ic
Fest o Did act ic
Non - retu rn valve
Pn eumati cs
Fest o Did act ic
Pn eumati cs
Non - retu rn valve
Fest o Did act ic
Non - retu rn valve
Non - retu rn valve
4
How flow control valves work
https://www.youtube.com/watch?v=iFlPta8valk
5
How Ball, Gate, Solenoid, Butterfly, Check and Relief valves
work?
https://www.youtube.com/watch?v=X14nww4wuAk
6
Shuttle Valve (OR Valve)
Pn eumati cs
Fest o Did act ic
◎
A
X
Y
A
X
Y
Shu ttle valve
Pn eum ati cs
X
A
Shu ttle valve
Y
X
A
Y
Fest o Did act ic
It has two inlets X and Y and one outlet
A.
◎ If compressed air is applied to inlet X,
the ball seals off inlet Y and the air
flows from X to A; alternatively, the air
flows from Y to A and inlet X is closed
◎ oWhen the air is reversed, i.e.
A cylinder or valve is exhausted, the ball
Pn eum ati cs
Fest o Did act ic
A
X
Y
A
X
Y
Shu ttle valve
remains in its previously assumed
position because of the pressure
conditions
7
Shuttle Valve (OR Valve)
Pn eumati cs
◎
A
X
Y
A
Pn eum ati cs
X
X
Y
A
Shu ttle valve
Y
X
A
Y
Fest o Did act ic
◎
It is also called an OR component; it
separates signals emitted from signal
valves in different positions and
prevents the air from being diverted
through a second signal wave
If a cylinder or control valve is to be
actuated from two or several positions,
shuttle valve must be used
Fest o Did act ic
Shu ttle valve
Pn eum ati cs
Fest o Did act ic
A
X
Y
A
X
Y
Shu ttle valve
8
Two-Pressure Valve (AND Valve)
◎
◎
◎
Pn eum ati cs
Fest o Did act ic
A
X
Y
A
It has two inlets and one outlet.
Compressed air flows through the valve
only if signals are applied to both
inlets; one input signal blocks the flow.
If signals are applied to both X and Y,
the signal which is last applied passes
to the outlet
X
Y
Two pressure valve
Pneumati cs
Festo Didactic
A
X
Y
A
X
Y
Two pressure valve
9
Two-Pressure Valve (AND Valve)
◎
◎
Pn eum ati cs
Fest o Did act ic
A
X
Y
A
If the input signals are of different
pressures, the larger of the two
pressures closes the valve and the
smaller air pressure is transferred to
the outlet as an output signal.
The two pressure valve is used mainly
for interlocking controls, check
functions and logic operations.
X
Y
Two pressure valve
Pneumati cs
Festo Didactic
A
X
Y
A
X
Y
Two pressure valve
10
Flow Control Valve
◎
Throttle relief valve (speed regulating
valve, one-way flow control valve)
○
◎
Air flow is throttled in one direction
only
○
A check valve blocks the flow of air in
one direction, and the air can flow only
through the regulated cross-section
○
In the opposite direction, the air can
flow freely through the opened check
valve
Used for speed regulation of
pneumatic cylinders
○
Supply air throttling
○
Exhaust air throttling
Pn eumati cs
Fest o Did act ic
Pn eum ati cs
Fest o Did act ic
One w ay f low con trol valve
One way flow con trol valve
11
Supply Air Throttling
◎
◎
◎
For supply air throttling, one-way flow
control valves are installed so that the
air entering the cylinder is
throttled.
The exhaust air can escape freely
through the check valve of the throttle
valve on the
outlet side of the
cylinder.
Supply air throttling can be used for
single-acting and small volume
cylinders
12
Exhaust Air Throttling
◎
◎
◎
The supply air flows freely to the
cylinder and the exhaust air is throttled
The piston is loaded between two
cushions of air
○ First cushion effect is supply
pressure to the cylinder
○ and second cushion is the
exhausting air being restricted at
the one way flow control valve
orifice
○ This leads to improvement of feed
behaviour.
Exhaust air throttling should be used for
double acting cylinders
13
“
Additional reading materials
14
Recap Questions
Name a pneumatic component where a
01 spring-loaded check valve is used
o
Manifold
Name a pneumatic component where a
02
check valve is used
o Throttle valve
If a cylinder or control valve is to be actuated from two or
03 several sources, what pneumatic component can be used
o
Shuttle valve
04 When is the two pressure valve is used?
o For interlocking controls, check functions and logic operations
15
Recap Questions
Explain the main difference between
05 supply and exhaust air throttling
o
For supply air throttling, one-way flow
control (or throttle) valve is installed so
that the air entering the cylinder is
throttled.
o With exhaust air throttling, the supply
air flows freely to the cylinder and
the types of cylinder that should be used with
06 Name
exhaust air is throttled.
supply air throttling
o Single-acting and small volume cylinders
07
Name the types of cylinder that should be used with
exhaust air throttling
o Double acting cylinders
16
Recap Questions
Given
A 5/2 way push-button activated and
spring-returned directional control
valve.
Draw
A pneumatic circuit to control the
cylinder with exhaust air throttling on
its forward stroke.
17
Designating The Elements
Two types of designation:
o Using Digits
o Using Letters
Designation Using Digits:
This system is advisable for complex controls and particularly in
such cases where possibility the designation is composed of the
group no. and serial numbering within the group cannot be
considered because of overlapping
18
Designating The Elements
o
Classification of groups:
o Group 0
o Group 1. , 2., 3.
: All energy supply elements
: Designation of the individual control chain
(per cylinder, normally one group
no.)
o
System for serial numbering:
o .0
o .1
o .2, .4 (even no.)
cylinder
o .3, .5 (odd no.)
o .01, .02
element and working
valves
: Working elements
: Control elements
: Influence on advance movement of
: Influence on return movement of cylinder
: Elements between control
element e.g. throttle
19
Port Designation with DIN ISO 5599-3
20
Designating The Element Using Digits
1.0
1.3
1.0
1
1.1
1.
4
1.2
1.6
0.
1
21
1.3
Designating The Elements Using Letters
◎
◎
◎
This type of designation is used
especially where circuit diagrams are
being developed methodically
Usually involves calculations and
listings which can be performed more
easily and more clearly when using
letters
o
Working elements
capital
letters
o
Signal elements/limit
switches
small
letters
Limit switches or signal elements are not assigned to the
group which they influence but to the cylinder which acts on
them
22
Designating The Elements Using Letters
ao
a1
A
◎
A,B,C,…
○ Designation of working elements
◎
ao , bo , co , ...
○
◎
a1, b1 , c1 ,...
○
◎
Designation of the limit switches which are actuated in the rear end
positions of cylinders A, B, C, etc.
Designation of the limit switches which are actuated in the extended
rod position of cylinders A, B, C, etc.
It is possible to have a combination of digits and letters when designation
elements
23
Recap Questions
01
If the port of directional control valve
bears the character ‘P’ or the numeral
1, what is the purpose of the port? 2
4
o Used as an air pressure port
5
02
1 3
If the port od a directional control valve bears the character ‘R’
or ‘S’ or numeral 3 or 5, what is the purpose of the port?
o Used as an exhaust port
24
Recap Questions
Draw
The pneumatic symbol for a 3/2-way,
solenoid actuated, normally close,
spring-returned valve
OR
1CR
PB
Fully define
1CR1
SOL 1
The valve represented by its pneumatics symbol
3/2 way, normally open, rolleractuated, spring-returned directional
control valve
25
Lecture 5
Introduction To Characteristics And
Applications Of Electro-mechanical Control
Components
In this session, you will be introduced to:
1
Electro-pneumatic control and its
2
applications
Working principles, applications and symbolic
representation of:
3
Electrical signal input devices
4
Contactless signal
emitters
5
Electromagnetic relays
6
Solenoid valves
2
Advantages of Electro-Pneumatics
Electro-pneumatic control systems have the following
advantages over pneumatic control systems
Higher reliability (fewer moving parts subject to wear)
Lower planning and commissioning effort, particularly for
complex controls
Lower installation effort, particularly when modern
components such as valve terminals are used
Simpler exchange of information between several controllers
3
Automation
https://www.youtube.com/watch?v=iw2t4rCXSiE
4
Signal Flow and Components of an Electro-Pneumatic Control System
The directional control
valves from the interface
between the signal
control section and the
pneumatic power section
in electro-pneumatic
control system
5
Electrical / Pneumatic Parts of Electro-Pneumatic System
Pneumatic Circuit
Electrical Circuit
Electro-pneumatic control systems are not shown in any single
overall circuit diagram, but in TWO separate circuit diagrams:
0 Pneumatic
1 Part
0 Electrical
Part
6 2
Limit Switches
◎ The limit switch is actuated when
a machine part or a work-piece is
in a certain position.
Normally, actuation is affected by
a cam or cylinder piston.
7
Limit Switches
◎
Normally
open
Normally open, held
closed
Symbol for Limit Switches
Normally
closed
Normally closed, held
open
8
Double
circuit
Contactless Signal Emitters
Reed
Switches
9
o
Commonly used to sense the
position of pneumatic cylinder
piston rods
o
Small size and short switching
time
o
Actuated by a magnetic field
o
Long service life &
maintenance-free
o
Must not be used in
environments subject to strong
magnetic fields
Contactless Signal Emitters
Proximity Sensors
10
o
Electronic limit switches
(sensors) which operate without
contact
o
Switch upon approach without
noise, impact or reaction,
without contact wear and
without actuating force.
o
Inductive, capacitive, optical
type
Contactless Signal Emitters
THREE different types of optical proximity switch are
differentiated
0 One-way light
1 barrier
11
Contactless Signal Emitters
THREE different types of optical proximity switch are
differentiated
0 Reflective light
2 barrier
12
Contactless Signal Emitters
THREE different types of optical proximity switch are
differentiated
0 Diffuse reflective
3 optical sensor
13
Electro-Magnetic Relays
14
Electro-Magnetic Relays
◎
Circuit symbols for Electro-Magnetic
relay
1CR
1CR1
NO
1CR2
NC
15
Advantages of Relay
o
Easily adapted to various operating
voltages
o
Several independent circuits can be
switched
o
o
There is electrical isolation between the
control
circuit
and the
main
circuit.
Not
much
affected
by the
temperature
of their surroundings
(still operate reliably at 40 – 80 deg C)
o
Relatively high resistance between contacts in the off-state [open]
16
Disadvantages of Relay
o
Working surface wear of contacts through
arcing or oxidation
o
Large space requirement compared to
transistors
o
The contacts are affected by
contamination [dust]
o
Nose is created during the switching
operation
o
Limited switching speed of 3 ms – 17 ms
17
Time-Delay Relays
◎
Similar to a control relay except that provision is made for an adjustable delay
switching action
Time Delay On De-Energization
(TDODE)
Time Delay On Energization
(TDOE)
1
0
1
1
TR
COIL
0
1
TD
NO
TD
NO
0
1
0
1
0
TR
COIL
NC
0
TR
NO
Timed contact
NC
TR
NC
Timed contact
18
NO
Timed contact
NC
Timed contact
Solenoid Valves
◎
It consists of pneumatic valve and an electrical
signal switching part (solenoid head)
◎
Solenoid coils are attached to the valves to
actuate them
◎
It is basically the same as the valves used
conventionally but difference is that the valve is
actuated by a solenoid
19
Solenoid Valves
◎
Physical Unit
20
Solenoid Valves
◎
Different Symbols
21
“
Additional reading materials
22
Recap Questions
01
List the advantages of electropneumatic control systems over
pneumatic control systems
o
o
Higher reliability
Lower planning and commissioning
effort
o Low installation effort
o Simpler exchange of information
Which
component
the interface between the signal
between
several forms
controllers
02
control section and pneumatic power section in electropneumatic control system
o
Directional control valve
23
Recap Questions
Draw
The symbol of a limit switch with normally
open condition
24
Recap Questions
04 Name the main features of a reed
switch
o Small size and short switching time
o Actuated by a magnetic field
o Long service life & maintenance-free
05 What environment would affect the
usage of reed switches?
o Environment subject to strong magnetic
fields
06 Name the different types of optical proximity
switch
o One-way light barrier
o Reflective light barrier
o Diffuse reflective optical sensor
25
Recap Questions
07 Name the parts of the control relay
[1
]
[2
]
[3
]
[5
]
[1] = Return spring
[2] = Relay coil
[3] = Armature
[4
]
[6
]
[4] = Coil core
[5] = Insulation
[6] = Contact
26
Recap Questions
08 List the advantages of control relays
o
o
o
o
o
Easily adapted to various operating
voltages
Several independent circuits can be
switched
There
is electrical
between theof their surroundings (still
Not much
affectedisolation
by the temperature
control
and
circuit
operatecircuit
reliably
at the
40 –main
80 deg
C)
Relatively high resistance between contacts in the off- state [open]
27
Recap Questions
09 List the disadvantages of control relays
o
o
o
o
o
Working surface wear of contacts through
arcing or oxidation
Large space requirement compared to
transistors
The contacts are affected by
contamination [dust]
Noise is created during the switching
operation
Limited switching speed of 3 ms – 17 ms
28
Lecture 6
Introduction To The Basic Design Concept Of
Electro-Pneumatic Circuits
In this session, you will be introduced to:
1
Functions of an Electro-Magnetic
2
Relay
Ladder Diagrams
3
Guidelines on drawing ladder diagram
4
Graphical Symbols for some commonly used ElectroMechanical Devices
5
Samples of Basic Electro-Pneumatics Control Circuits
6
Control Circuits with Time Response
2
Functions of Electro-Magnetic Relay
Amplificati
on
Non-Equal Supply
Voltage
Multiplication of Output
Contact
Logic
Operation
Memorization Latching
Circuit
3
What is Ladder Logic?
https://www.youtube.com/watch?v=qal48NCUvkA
4
Functions of Electro-Magnetic
Relay
Amplification
5
Functions of Electro-Magnetic
Relay
Non-Equal Supply Voltage
6
Functions of Electro-Magnetic
Relay
Multiplication of Output Contacts
7
Functions of Electro-Magnetic
Relay
Logic Operation “AND” and “OR”
“AND”
“OR”
8
Functions of Electro-Magnetic
Relay
Memorization Latching Circuit
1PB
2PB
9
Control Relay Ladder Diagram
◎
Schematic Diagram representing an
Electrical Control Circuit in Electrical
Sequence.
Drawn with two vertical lines which
represent electrical leads with the
control circuit voltage applied
between them
◎
◎
Horizontal Lines (or rungs) appear on
the diagram as various components
are added
1PB
2PB
1CR
2CR
1CR1
1SOL
2CR1
2SOL
Commonly called Ladder Diagram
because of its appearance
10
Control Relay Ladder Diagram
◎
The current directions on the Ladder
Diagram would go from left to right
◎
Actuating coils are shown on the right
hand side
◎
All contacts are drawn between the
coils and the left vertical line
◎
Contacts and switches are shown in
their normal or de-energized positions
1PB
2PB
1CR
2CR
1CR1
1SOL
2CR1
2SOL
11
Graphical Symbols of Electro-Pneumatic Devices
TDOE
TR
1CR
TDODE
1CR1
NO
1CR2
NO
Timed contact
TR
NC
Timed contact
NC
NO
Timed contact
NC
Timed contact
12
Graphical Symbols of Electro-Pneumatic
Devices
◎
Symbol for Limit Switches
Normally
open
Normally
closed
Normally open, held
closed
Normally closed, held
open
13
Control of Single-Acting & Double-Acting Cylinder
◎
The following diagrams shows 3 Pneumatic Circuits
14
Control of Single-Acting & Double-Acting Cylinder
◎
Both solutions can activate the 1SOL. Which one will be
preferred?
Solution 1
24v
1PB
1 SOL
Solution 2
0v
OR
24v
1PB
0v
1CR
1 CR1
1 SOL
15
Control of Single-Acting & Double-Acting Cylinder
24v
1PB
0v
1CR
1 CR1
1 SOL
Solution 2 should be applied:
0
1
When the switching capacity of
signaling deice 1 PB is not sufficient
to switch coil 1SOL
16
Control of Single-Acting & Double-Acting Cylinder
24v
1PB
0v
1CR
220v
0v
1 CR1
1 SOL
Solution 2 should be applied:
0
2
If further processing is required with
a different voltage (220V)
17
Control of Single-Acting & Double-Acting Cylinder
24v
1PB
0v
1CR
1 CR1
X CRx
1 SOL
Solution 2 should be applied:
0 When combinations and interlocks are
3 needed
18
Parallel (OR Logic) & Series (AND Logic) Circuits
◎
The 2 pneumatic circuits can be activated by 2 different
modes.
◎
OR logic, either 1PB or 2PB can activate 1 SOL
24v
OR logic
0v
1 PB
1CR
2 PB
1 CR1
19
1 SOL
Parallel (OR Logic) & Series (AND Logic) Circuits
◎
The 2 pneumatic circuits can be activated by 2 different
modes.
◎
OR logic, either 1PB or 2PB can activate 1 SOL
20
Automatic Return of Cylinder Initiated by Limit Switch
21
Oscillating Motion of Double-Acting Cylinder
22
Latching Circuit (Electrical Memory)
◎
Latching circuits are required in electro-pneumatic control
systems when there is a need to store (memorize) electrical
signals
1PB [ON]
1PB [ON]
CR
CR1
2PB [OFF]
cct 1
CR
2PB [OFF]
CR1
cct 2
cct 2
Dominant-ON
DominantOFF
23
cct 1
Control of Cylinder with Latching Action
1 PB
1 CR
1CR1
cct 1
2 PB
cct 2
1CR2
1 SOL
cct 3
24
Time-Dependent Control System with Latching Circuit
(Energizing Delay)
◎
In the Pneumatic Diagram shown below, Cylinder A must
retract after a stipulated time delay when it is fully
extended
25
Time-Dependent Control System with Latching Circuit
(Energizing Delay)
Time Delay On Energization (TDOE)
26
Time-Dependent Control System with Latching Circuit
(De-Energizing Delay)
◎
In the Pneumatic Diagram shown below, Cylinder A must
retract after a stipulated time delay when it is fully
extended
27
Time-Dependent Control System with Latching Circuit
(Energizing Delay)
Time Delay On De-Energization (TDODE)
28
“
Additional reading materials
29
Recap Questions
01
Name the functions of an ElectroMagnetic Control Relay
o
Amplification
o
Non-Equal Supply Voltage
o
Multiplication of Output Contacts
o
Logic Operation
o
Memorization Latching Circuit
Draw
The symbol of a TDODE (Time Delay On De-Energization)
timer relay and its Normally Open (NO) timed contact
TR
30
Recap Questions
Draw
The timing diagram for a Normally Close
(NC) timed contact of a TDODE timer relay
which is set to 4 seconds delay
31
Recap Questions
04
You are given a normally close pushbutton (1PB) and a control relay (1CR)
Draw
an Electrical Ladder Diagram to control
the extension of the cylinder rod indirectly
via the control relay when the push-button
is activated.
32
Recap Questions
05
Briefly describe situations where the
indirect method above must be applied
instead of actuating solenoid coil 1SOL
directly
o
o
When the switching capacity of signalling
device
1PB
is not sufficient
to switch
If further
processing
is required
with acoil
different
1SOL
voltage
o
When combinations and interlock are needed
33
Recap Questions
06
Given two push buttons (1PB and 2PB)
and an Electro-Magnetic Control Relay
(CR).
Draw
the Electrical Ladder Diagram to illustrate
DOMINANT-ON latching of the control
relay.
34
Lecture 7
Method Of Representing Sequences of Motion
and Switching Conditions
In this session, you will be introduced to:
1
Positional Sketch
2
Chronological Order
3
Tabular Form
4
Abbreviated Notation of
Motion
7
Displacement-Time Diagram
5
Motion Diagram
8
Control Diagram
6
Displacement- Step Diagram
2
High Speed Overwrapping Machine – Box Packing Machine –
ARCOPACK
https://www.youtube.com/watch?v=l-_-JoJVlzQ
3
The Need for Representing
Sequences of Motion
◎ To allow sequences of motion and
switching conditions of the various
elements in control systems to be
detected rapidly and reliably
◎ To replace or supplement the verbal
of control system
◎ description
To improve communication
between specialists from the fields of
mechanical engineering, electrical engineering and electronics
4
Methods of Representing Sequences of Motion
◎ Methods of Representing
Sequences of Motion can be
descriptive or graphical form:
o
o
o
o
o
Positional Sketch
Chronological Order
Tabular Form
Abbreviated Notation of Motion
Motion Diagram
o Displacement- Step Diagram
o Displacement- Time Diagram
o Control Diagram
o Function Chat
5
Positional Sketch
shows the relationship between the
actuators and the machine fixture. The
actuators are shown in the correct
orientation. The Positional Sketch is not
normally to scale and should not be too
detailed
Description of Application
o
Metal Sheets are bent with the bending
tool.
The sheet is inserted manually;
o When the start button has been pressed,
Cylinder A clamps the workpiece;
o Cylinder B bends the part and travels
back;
o Cylinder C makes the final bend
Bending Device Application
o When Cylinder C has returned to its final
rear position, Cylinder A releases the part
6
Chronological Order
7
Tabular Order
8
Abbreviated Notation of Motion
◎
◎
Abbreviated Notation is another possibility of representing
motion sequences
The signal for advancing is designated using a ‘+’ and the signal
for retracting using ‘-’
The sequence
B- A-
A+
B+
The sequence
B-
Isi.toCylinder
be readAas
follows:
advances,
A+
B+
AIs to be read as:
i. Cylinder A advances,
ii. Cylinder B advances,
ii. Cylinder B advances and Cylinder A
retracts
iii.Cylinder B retracts,
iv. Cylinder A retracts.
iii.Cylinder B retracts,
equential movements are written consecutivelySimultaneous movements are written vertically
9
MOTION DIAGRAM:
Displacement-Step
Diagram
◎ Displacement is entered as a function of
steps
(a step is a change in conditions of any
◎
The
individual movement steps are numbered consecutively
component)
from left to right
◎ If several working elements are present in a control system, they
are represented in the same way and drawn one below other
10
MOTION DIAGRAM: Displacement-Step Diagram
◎
The diagram illustrates how the various movements follow on from
each other
A+ B+ B- C+ C- A-
11
MOTION DIAGRAM:
Displacement-Time
Diagram
◎ In contrast to the Displacement and Step
Diagram,
the time t is drawn linearly here and
represents
the time relationship between the
individual
components in the sequence
12
MOTION DIAGRAM: Displacement-Step Diagram
◎
This form of representation highlights the different lengths of time needed for
individual steps.
A+ (5s) B+ (1s) B- (1s) C+ (3s) C- (3s) A- (5s)
13
Control Diagrams
◎ Switching conditions of Signal Input
Elements and signal processing
elements are entered as a function of
steps
Drawn in conjunction with Motion
◎ When
both the Motion Diagram and Control Diagram
Diagram
are combined, they are referred to as a Faction Diagram
14
Control Diagrams
1
An Engineer is supposed to design a final product with
a J shape.
He came out with the following design.
Upon depressing a Start Button (S7), Cylinder A will
extend to clamp a 5mm thick rectangular Aluminum
Bar.
When the Aluminum Bar is clamped, Cylinder B will
extend to provide a first bend.
When the first bend is completed, Cylinder C will
then extend to provide a second bend.
After the completion of the second bending action,
A+
the cylinders will retract in the reverse order in which
they were extended.
The extension and retraction of the cylinders are
detected by limit switches S1 to S6 as shown in the
diagram.
15
Sequence:
B+
C+
C-
B-
A-
Control Diagrams
Sequence:
A+ B+
C+
C-
B-
A-
16
“
Additional reading materials
17
Recap Questions
01
Name the needs for representing
sequences of motion of actuators
o
o
o
To allow sequences of motion and
switching conditions of the various
elements in control systems to be detected
rapidly
and reliably
To replace
or supplement the verbal description of a control system
To improve communications between specialists from the fields of
mechanical engineering, electrical engineering and electronics
18
Recap Questions
02 What is the purpose of a 3-D Positional
Sketch?
o
3-D Positional Sketch shows the
relationship between the actuators and the
In abbreviated
notional of motion,
machine fixture
03 what does the ‘+’ and ‘-’ symbol
represents?
o
Signal for advancing is designated using a ‘+’ and the signal for
retracting using a ‘-’
How are sequential and concurrent movement represented in
05
abbreviated notation of motion?
o
o
Sequential movements are written consecutively
Simultaneous movements are written vertically
19
Recap Questions
06 What is a Displacement-Step Diagram?
o
o
Displacement of Cylinder is entered as
function of step
It illustrates how the various cylinder
movements follow on from each other
07 What is a Displacement-Time Diagram?
o
Displacement of Cylinder is entered as a Function of Time to
represent the time relationship between the individual
components in the sequence
o It highlights the different lengths of time needed for individual
is a Control Diagram?
steps
08 What
o
In Control Diagram, switching conditions of signal input
elements and signal processing elements are entered as a
function of steps.
20
Lecture 8
Demonstration of development of electro- …
pneumatic circuit using a practical example
In this session, you will be introduced to:
1 Multiple actuators circuit development
2
Multiple cylinders design using
Grouping method
3
Multiple cylinders design using
Stepping Sequence method
2
Multiple Actuators Circuit Development
Circuits employing a number of double
solenoid valves, a common problem is
that sequence of actions within the circuit
can generate overlapping signals on
opposing sides of solenoid valves.
SOL 1
Overlapping signals.
Solenoids of the opposing sides of a
valve are generated at the same
time.
SOL 2
3
Multiple Actuators Circuit Development
Limit switch
Require inclusion of relay, or limit switch
contact configurations that make or break
current paths at the appropriate point in
the sequence of actions within the circuit
SOL 1
24V
SOL 2
0V (GND)
Electrical ladder
diagram
START
Limit switch
XCR
XCR1
Only one contact will be
activated at one time,
therefore there will not
be any signals overlap.
XCR2
SOL 1
SOL 2
4
Multiple Actuators Circuit Development
Alternative methods of signals cut
off
Idle return rollers
Memory cutoff
circuits
Timers
TR
1PB [ON]
Signal cutoff contact
2PB [OFF]
CR
NO
Timed contact
cct 1
NC
Timed contact
CR1
cct 2
5
Multiple Cylinders Design using Grouping Method
Signal Overlap
In design of circuits involving a
number of cylinders, it is
frequently found that circuitry is
complicated by presence of
unwanted signals (signals from
early part of circuit are present
later in the sequence and oppose
new signals)
SOL 2
SOL 1
?
6
Multiple Cylinders Design using Grouping Method
Grouping method makes use of relays for signal cut-off which
provides a convenient solution to the problem.
Actions/Sequences
in Group 1
Actions/Sequences
in Group 2
Cutting off the power
to Group 1
through a relay
Cutting off the power
to Group 2
through a relay
Actions in Group
XXX
Cutting off the power
to Group XXX
through a relay
7
Multiple Cylinders Design using Grouping Method
Electric current to various limit switches and
solenoid are no longer derived from the main
supply, but through a pair of contacts of one of
the relays in such a way that the limit switches
are only "live" while they are performing their
required task.
24V
0V (GND)
Electrical ladder
diagram
Limit switch
XCR
XCR1
SOL 1
8
Multiple Cylinders Design using Grouping Method
At other times, and particularly during those
times when presence of a signal would prevent
cylinder reversal, limit switches are without
electric current or "dead"
24V
0V (GND)
Electrical ladder
diagram
Limit switch
XCR
XCR1
SOL 1
9
Illustration of Grouping Method
From Laboratory Exercise EP4
Two clips are to be riveted together on a semi-automatic
press.
Components and rivet are positioned by hand and then
removed by hand on completion of the riveting
operation.
10
Illustration of Grouping Method
From Laboratory Exercise EP4
The automated part of the working cycle consists of the
holding and clamping of the components (cylinder A) and
also the riveting (cylinder B) and the cycle should be
performed ending at the starting position after operating
a start button
11
Illustration of Grouping Method
Pneumatic Circuit
A
SOL 1
1LS
SOL 2
B
2LS
SOL 3
3LS
4LS
SOL 4
12
Illustration of Grouping Method
Abbreviated representation of motion and actuation signals
1PB
2LS
4LS
A+ B+ B-
3LS
1LS
A-
+
13
Illustration of Grouping Method
Displacement-step diagram
2LS
1
Cylinder A
0
1
1PB
1LS
4LS
Cylinder B
3LS
0
+
14
Control diagram
Illustration of Grouping Method
1
1LS
0
1
1PB + 1LS starts
A+
2LS starts B+
4LS starts B3LS starts A-
2LS
0
1
3LS
0
1
4LS
0
1
1PB
0
Step 1: A+
15
Control diagram
Illustration of Grouping Method
1
1LS
0
1
1PB + 1LS starts
A+
2LS starts B+
4LS starts B3LS starts A-
2LS
0
1
3LS
0
1
4LS
0
1
1PB
0
Step 2: B+
16
Control diagram
Illustration of Grouping Method
1
1LS
0
1
1PB + 1LS starts
A+
2LS starts B+
4LS starts B3LS starts A-
2LS
0
1
3LS
0
1
4LS
0
1
1PB
0
Step 3: B-
17
Control diagram
Illustration of Grouping Method
1
1LS
0
1
1PB + 1LS starts
A+
2LS starts B+
4LS starts B3LS starts A-
2LS
0
1
3LS
0
1
4LS
0
1
1PB
0
Step 4: A-
18
Illustration of Grouping Method
Each group can consist actions/sequences of more than 1
cylinder
|
|
A+
B+
Group 1
…
| …
…
…
Group 2
19
Illustration of Grouping Method
In each group there should only be actions/sequences from
1 cylinder, whether ‘+’ or ‘-’
|
A+
B+
Group 1
|
B-
A-
|
Group 2
20
Illustration of Grouping Method
Each group should expand to cover as much cylinder
actions/sequences as possible without violating the previous
rules
|
A+
B+
Group 1
|
B-
A-
|
Group 2
21
Identification of Signal Overlap using Control digram
Control diagram
1
1LS
0
1
1PB + 1LS starts
A+
2LS starts B+
4LS starts B3LS starts A-
2LS
0
1
3LS
0
1
1LS and 3LS are signals that
activates opposing signals
4LS
activating Cylinder A. They
0
should be in different
1
groups.
1PB
0
Step 1: A+
Step 4: A-
22
Identification of Signal Overlap using Control digram
Control diagram
1
1LS
0
1
1PB + 1LS starts
A+
2LS starts B+
4LS starts B3LS starts A-
2LS
0
1
3LS
0
1
2LS and 4LS are signals that
activates opposing signals
4LS
activating Cylinder B. They
0
should be in different
1
groups.
1PB
0
Step 2: B+
Step 3:B-
23
Identification of Signal Overlap using Control digram
Control diagram
1
1LS
0
1
1PB + 1LS starts
A+
2LS starts B+
4LS starts B3LS starts AArrange the groups in a way
that there is no signal
overlaps in one group.
2LS
0
1
3LS
0
1
4LS
0
1
1PB
0
Step 1: A+
Step 2: B+
Group 1
Step 3:B-
Step 4: A-
Group 2
24
Subdivision of actions/sequences into groups
◎
The actions/sequences in each group
is subdivided and actuated by
different contacts
24V
Electrical ladder diagram
0V (GND)
1PB
1CR
◎
Only 1 group will be activated at any
time.
1 PB
not
activated
1CR2
Group 1 ‘dead'
1CR3
Group 2 ‘live'
25
Subdivision of actions/sequences into groups
◎
The groups interlocked, or switched,
depending on the inputs to the relay
coil.
24V
Electrical ladder diagram
0V (GND)
1PB
1CR
1 PB
activated
1CR2
Group 1 ‘live'
1CR3
Group 2 ‘dead'
26
Subdivision of actions/sequences into groups
◎
The inputs to start of the first step is
1PB and 1LS
Electrical ladder diagram
0V (GND)
24V
1PB
1LS
1PB + 1LS
◎
Activation of solenoid 1 extends
cylinder A
1CR
1CR2
SOL 1
Sol 1 activates A+
1CR3
27
Subdivision of actions/sequences into groups
◎
A latch is required to retain the power
to the coil once 1LS is ‘opened’ when
the cylinder is extended after a short
while
Electrical ladder diagram
0V (GND)
24V
1PB
1LS
1CR
1CR1
Latch
◎
The latch also allows the operator to
release 1PB anytime before first
action is completed
1CR2
SOL 1
Sol 1 activates A+
1CR3
28
Subdivision of actions/sequences into groups
◎
The second sequence B+ needs to
wait for the first sequence A+ to be
completed.
Electrical ladder diagram
0V (GND)
24V
1PB
◎
◎
Completion of first sequence (or
actuation signal of second sequence)
is 2LS
Activation of solenoid 3 extends
cylinder B
1LS
1CR
1CR1
1CR2
SOL 1
Sol 1 activated A+
2LS
SOL 3
Sol 3 activates B +
1CR3
29
Subdivision of actions/sequences into groups
◎
Group 2 actions/sequences will be
activated once all Group 1
actions/sequences are completed
Electrical ladder diagram
0V (GND)
24V
1PB
◎
4LS is the input to switch from Group
1 to Group 2. (Refer to Abbreviated
Representation of Motion and
Actuating Signals)
1LS
4LS
1CR
1CR1
1CR2
SOL 1
Sol 1 activated A+
2LS
◎
4LS also denotes the end of 2nd
sequence and start of 3rd sequence
4LS cuts off Group 1
and activates Group 2
SOL 3
Sol 3 activated B +
1CR3
30
Subdivision of actions/sequences into groups
◎
Activation of solenoid 4 retracts
cylinder B
Electrical ladder diagram
0V (GND)
24V
1PB
1LS
4LS
1CR
1CR1
1CR2
SOL 1
Sol 1 activated A+
2LS
1CR3
SOL 3
Sol 3 activated B +
SOL 4
Sol 4 activates B -
31
Subdivision of actions/sequences into groups
◎
Completion of third sequence (or
actuation signal of fourth sequence) is
3LS
Electrical ladder diagram
0V (GND)
24V
1PB
1LS
4LS
1CR
1CR1
1CR2
SOL 1
Sol 1 activated A+
2LS
1CR3
SOL 3
Sol 3 activated B +
SOL 4
Sol 4 activated B -
3LS
SOL 2
Sol 2 activates A -
32
Subdivision of actions/sequences into groups
◎
The whole cycle repeats again when
the operator activates 1PB.
Electrical ladder diagram
0V (GND)
24V
1PB
1LS
4LS
1CR
1CR1
1CR2
SOL 1
2LS
1CR3
SOL 3
SOL 4
3LS
SOL 2
33
Cascade method/Stepping Sequence method
◎
Alternative method of sequencing can be done by
Cascade method
Electrical ladder diagram
24V
1PB 4CR2
1LS
0V (GND)
2CR2
1CR
1CR1
1CR3
1CR4
3CR2
2LS
2CR1
2CR3
4LS
2C
R
2CR4
3CR
3CR4
3LS
SOL 3
4CR2
3CR1
3CR3
SOL 1
SOL 4
1CR2
4CR
4CR4
SOL 2
4CR1
2PB
34
Cascade method/Stepping Sequence method
◎
Upon depressing of 1PB, 1CR will be activated
Electrical ladder diagram
24V
1PB 4CR2
1LS
0V (GND)
2CR2
1CR
Latch
Standby the
next step
1CR1
1CR3
1CR4
3CR2
2LS
2CR1
2CR3
4LS
2C
R
2CR4
3CR
3CR4
3CR3
3LS
A+
SOL 3
4CR2
3CR1
Cut off the
previous step
SOL 1
SOL 4
1CR2
4CR
4CR4
SOL 2
4CR1
2PB
35
Cascade method/Stepping Sequence method
◎
Latch will continue to energize 1CR through the latch when cylinder A is
still extending
Electrical ladder diagram
24V
1PB 4CR2
1LS
0V (GND)
2CR2
1CR
Latch
1CR1
1CR3
1CR4
3CR2
2LS
2CR1
2CR3
4LS
2C
R
2CR4
3CR
3CR4
3LS
A+
SOL 3
4CR2
3CR1
3CR3
SOL 1
SOL 4
1CR2
4CR
4CR4
SOL 2
4CR1
2PB
36
Cascade method/Stepping Sequence method
◎
The second relay takes over the sequence in a similar method to the first
sequence Electrical ladder diagram
24V
1PB 4CR2
1LS
0V (GND)
2CR2
Cut off the
previous step
1CR
1CR1
1CR3
Latch
2LS
2C
R
2CR1
2CR3
Standby the
next step
1CR4
3CR2
4LS
2CR4
3CR
3LS
SOL 3
A+
B+
4CR2
3CR4
3CR1
3CR3
SOL 1
SOL 4
1CR2
4CR
4CR4
SOL 2
4CR1
2PB
37
Cascade method/Stepping Sequence method
◎
The third relay takes over the sequence in a similar method to the first and
second sequence
Electrical ladder diagram
24V
1PB 4CR2
1LS
0V (GND)
2CR2
1CR
1CR1
1CR3
1CR4
2LS
3CR2
2C
R
2CR1
2CR3
Latch
4LS
Cut off the
previous step
2CR4
3CR
3LS
SOL 3
A+
B+
4CR2
3CR4
3CR1
3CR3
SOL 1
SOL 4
B-
1CR2
4CR
4CR4
SOL 2
4CR1
2PB
Standby the
next step
38
Cascade method/Stepping Sequence method
◎
The fourth relay takes over the sequence in a similar method to the previous
sequencesElectrical ladder diagram
24V
Standby the
next step
1PB
4CR2
1LS
0V (GND)
2CR2
1CR
1CR1
1CR3
1CR4
3CR2
2LS
2C
R
2CR1
2CR3
4LS
4CR2
3CR
2CR4
Cut off the
previous step
3CR4
3CR1
3CR3
Latch
3LS
SOL 3
SOL 4
A+
B+
B-
1CR2
4CR
4CR1
SOL 1
4CR4
SOL 2
A-
2PB
39
Cascade method/Stepping Sequence method
◎
2PB is a cold start to reset the whole sequence in power outages or
breakdowns.
Electrical ladder diagram
24V
1PB
4CR2
1LS
0V (GND)
2CR2
1CR
1CR1
1CR3
1CR4
3CR2
2LS
2C
R
2CR1
2CR3
4LS
2CR4
3CR
3LS
B+
3CR4
SOL 4
B-
1CR2
4CR
4CR1
SOL 3
A+
4CR2
3CR1
3CR3
SOL 1
4CR4
SOL 2
A-
2PB
40
Cascade method
◎
Summary of Cascade/Stepping sequence
At each
sequence,
a relay will
Prepare the next relay for next step
Cut off the relay of the previous step
A+
B+
Latch itself
Provide output contact
B-
A-
41
Recap Questions
Name the various signal cut-off methods
used to overcome overlapping signals
Idle return rollers
Timers
Memory cut-off circuits
Name the 2 types of memory cut-off
circuit
Grouping method
Stepping Sequence or Cascade Method
Lecture 9
Introduction to Programmable Logic
Controller
In this session, you will be introduced to:
1 Know the needs and historical development of PLCs
2
3
4
5
Define what is a Programmable Logic Controller (PLC)
and its advantages over relay systems
Applications of a PLC
Identify main parts of a PLC and describe their functions
How does a PLC work?
2
The need for PLCs
Hardwired panels were very time consuming to wire, debug and change.
3
The need for PLCs
In 1968, Hydramatic Division of
General Motors Corporation
identified the following requirements
for computer controllers to replace
hardwired panels
4
The need for PLCs
PLCs are solid state devices
5
The need for PLCs
Input and Output devices can be easily modified
Outputs
Inputs
PLC Device
6
The need for PLCs
Easily programmed and maintained by plant electricians
7
The need for PLCs
Able to function in an industrial environment
8
Historical Development of PLCs
1968
• Programmable concept developed.
1969
• Hardware CPU controller, with logic
instructions, 1 K of memory and 128 I/O
points.
1974
• Use of several (multi) processors within a
PLC - timers and counters; arithmetic
operations; 12 K of memory and 1024 I/O
points.
1976
• Remote input/output systems introduced.
9
Historical Development of PLCs
1977
• Microprocessors - based PLC introduced.
1980
• Intelligent I/O modules developed
• Enhanced communications facilities
• Enhanced software features (e.g. documentation)
• Use of personal microcomputers as programming aids.
1983
• Low - cost small PLC’s introduced.
1985
• Networking of all levels of PLC, computer and machine using SCADA
software
10
Current day PLC
◎
Smaller in size, more powerful and
added features.
Courtesy of wikimedia commons
11
Definition of a PLC
◎
A Programmable Logic Controller
(PLC) is a solid-state device
designed to perform logic
functions previously accomplished
by electro-mechanical relays
12
Definition of a PLC
A PLC is a digital operated
electronic apparatus that uses a
programmable memory for the
internal storage of instructions for
implementing specific functions,
such as logic, sequencing, timing,
counting, and arithmetic, to control
machines or processes through
digital or analog input or output
modules
13
Advantages of PLCs over Relay Control System
Less and simpler wiring
•Eliminates much of the hard wiring that was associated with conventional relay control
circuits.
Increased Reliability
•Once a program has been written and tested it can be downloaded to other PLCs.
High Flexibility
•Original equipment manufacturers (OEMs) can provide system updates for a process by
simply sending out a new program.
Lower Costs
•Originally PLCs were designed to replace relay control logic. The cost savings using PLCs
have been so significant that relay control is becoming obsolete, except for power
applications.
14
Advantages of PLCs over Relay Control System
Communications Capability
• A PLC can communicate with other controllers or computer
equipment
Faster Response Time
• PLCs operate in real-time which means that an event taking place
in the field will result in an operation or output taking place.
Easier To Troubleshoot
• PLCs have resident diagnostic and override functions allowing
users to easily trace and correct software and hardware problems.
15
Comparisons of PLC and Microprocessor
PLC
Higher speed and better performance
Ladder Program
PLC is a infinitely expandable input/output
logic controller usually programmed with a
external PC program
They are easy to program and troubleshoot.
Microprocessor
Low power CPU
With registers
Machine Language
A microcontroller is also a logic controller but
used in dedicated systems which are
programmed once and for all, the program for
which will not be accessed by the user, and
whose program will not need to be altered
frequently.
16
Standard functions of PLCs
The PLC can be considered to be a box full of hundreds or thousands of
separate relays, counters, timers and data storage locations.
These internal functions are not physical input or output; they are simulated
and can be considered software counters, timers, etc.
Internal relays (IR) are simulated through bit locations in registers.
17
Size of PLCs
Types of PLCs
Small
Medium
Large
Number of I/O
Up to 128
Up to 2048
Up to 8192
Memory size
Approx 2K Bytes
Approx 32K Bytes
Approx 750K Bytes
Application
•
Simple to Advanced
Machine control
•
Used in Process
Control
Individual Production
or Plant control
•
Used to replace logics
of wired relays,
counters, timers, etc.
•
Modular
Network of remote I/O
•
Allows many plug-in
modules
Used in sophisticated
processes like SCADA
and DCS.
•
Communication
module facilities,
input/outputs are
provided by adding
additional I/O cards
•
•
Compact and
Lightweight.
Usually Monolithic
18
Common PLC Manufacturers
19
Main parts of PLCs
Input/Output modules
Central Processing Unit
Programming
device
Input devices
Output devices
Programmable device
Input
module
Processor/
Memory
Power
supply
Output
module
Block diagram of a PLC
CPU
20
Input module of PLCs
Forms the interface by which
input field devices are connected
to the controller
Functions of input module
Reliable signal detection
Voltage adjustment of control
voltage to logic voltage
Protection of sensitive
electronics from external
voltages
Screening of signals
21
Output module of PLCs
Forms the interface by which
output field devices are
connected to the controller
Functions of output module
Voltage adjustment of logic
voltage to control voltage
Protection of sensitive
electronics from spurious
voltages from the controller
Power amplification sufficient
for the actuation of major
final control elements
Short-circuit and overload
protection of output modules
22
Centrol Processing Unit of PLCs
Controls and supervises all operations within the PLC by
carrying out programmed instructions stored in the memory.
Houses processor-memory modules & communications
circuitry and power supply
Power supply may be located inside CPU enclosure or
may be a separate unit mounted next to the enclosure .
Processor-Memory module contains microprocessor,
memory chips, circuits that store and retrieve information
from memory, and communications circuits required for
the programming device .
23
Centrol Processing Unit of PLCs
Memory can be placed into two categories:
Volatile
◉ will lose its stored information if all operating power is
lost or removed
◉ is easily altered and quite suitable for most
applications when supported by battery backup
Nonvolatile
◉ has the ability to retain stored information when
power is removed accidentally or unintentionally
◉ is generally unalterable
24
Programming of PLCs
Provides the primary means by
which the user can communicate
with the circuits of the controller
Allows the user to enter, change,
or monitor a PLC program
Examples are hand-held
programmers or PC with
appropriate software
25
Scanning cycle of PLCs
While the PLC is running, a
scanning process includes the
following 3 phases, which are
repeated continuously as
individual cycles of operation:
PHASE 1
Read Inputs
Scan
PHASE 2
Program
Execution
PHASE 3
Output
Scan
26
Scanning cycle of PLCs
◎
PHASE 1 – Input Status scan
• A PLC scan cycle begins with
the CPU reading the status of
its inputs.
PHASE 1
Read Inputs
Scan
PHASE 2
Program
Execution
PHASE 3
Output
Scan
27
Scanning cycle of PLCs
◎
PHASE 2 – Program Execution
• The application program is
executed using the status of
the inputs.
PHASE 1
Read Inputs
Scan
PHASE 2
Program
Execution
PHASE 3
Output
Scan
28
Scan time of PLCs
◎
PHASE 3 – Output Status Scan
• Once the program is executed,
an output status scan is then
performed, whereby the stored
output values are sent to
actuators and other field
output devices. The cycle ends
by updating the outputs.
As soon as Phase 3 is completed,
the entire cycle begins again with
Phase 1 input scan.
PHASE 1
Read Inputs
Scan
PHASE 2
Program
Execution
PHASE 3
Output
Scan
29
Scanning cycle of PLCs
The time it takes to implement a scan cycle is called SCAN TIME. The scan
time composed of the program scan time, which is the time required for
solving the control program, and the I/O update time, or time required to
read inputs and update outputs.
The program scan time generally depends on the amount of memory taken
by the control program and type of instructions used in the program. The
time to make a single scan can vary from 0.1 ms to 50 ms.
30
PLC Communications
Common uses of PLC communications ports
Changing resident PLC programs uploading/downloading from a supervisory controller .
(Laptop or desktop computer)
Forcing I/O points and memory elements from a remote
terminal.
Linking a PLC into a control hierarchy containing several
sizes of PLC and computer.
Monitoring data and alarms, etc. via printers or
Operator Interface Units (OIUs).
31
Recap Questions
Name the advantages of PLCs over Relay Control System
Less and simpler wiring
Increased reliability
High flexibility
Lower costs
Communications capability
Faster response time
Easier to troubleshoot
List the main parts of a PLC
I/O (Input/Output) modules
CPU (Central Processing Unit)
Programmable device
Recap Questions
Name the functions of the input module of a PLC
Reliable signal detection
Voltage adjustment of control voltage to logic voltage
Protection of sensitive electronics from external
voltages
Screening of signals
Name the functions of the output module of a PLC
Voltage adjustment of logic voltage to control voltage
Protection of sensitive electronics from spurious
voltages from the controller
Power amplification sufficient for the actuation of major
final control elements
Short-circuit and overload protection of output modules
Recap Questions
Name the phases of the scan cycle of the PLC
PHASE 1 – Input Status scan
PHASE 2 – Program Execution
PHASE 3 – Output Status Scan
What is the scan time of the PLC?
Scan time is composed of:
•
Program scan time - time required for solving the
control program
•
I/O update time - time required to read inputs and
update outputs
What factors can affect the program scan time of the PLC?
Amount of memory taken by the control program
Type of instructions used in the program
Lecture 10
Programmable Logic Controller (PLC)
operations
In this session, you will be introduced to:
1 Principles of operations of a PLC
2
3
4
5
Convert the fundamental relay ladder diagram to PLC
logic ladder diagrams
Types of PLC programming languages
Draw basic PLC logic ladder programs and covert it to
Boolean Mnemonic language
Guidelines for drawing PLC ladder diagram
2
PLC example
Mixer Process control
A mixer motor automatically
stirs the liquid in a vat when
the temperature and pressure
reach preset values
In addition, direct manual
operation of the motor is
provided by means of a
separate push-button station
The process is monitored with
temperature and pressure
sensor switches that close
their respective contacts
when conditions reach their
preset values
3
PLC example
Mixer Process control
◎
Motor starter coil is energized
when both the pressure and
temperature switches are
closed or when the manual
pushbutton is pressed
Electrical ladder diagram
120V
Pressure Temperature
switch
switch
Motor
starter
coil
0V (GND)
Overload
relay
M
Manual pushbutton
4
I/O assignment or Allocation List
Input Allocation list
Mixer Process control
Designation
Address
Pressure Sensor
INPUT0_0
Temperature Sensor
INPUT0_1
Pushbutton
INPUT0_2
◎
Each input and output
device is given an address.
◎
This lets the PLC know
where they are physically
connected
Output Allocation list
Designation
Address
Motor starter coil
OUTPUT0_0
5
PLC example
Mixer Process control
PLC I/O Module Connections
Same input field devices are
used & wired to input module
according to the
manufacturer’s labelling
scheme
6
PLC example
Mixer Process control
PLC I/O Module Connections
◎
Same output field device is
used and wired to the output
module according to the
manufacturer’s labelling
scheme
7
PLC example
Mixer Process control
Modifying The Operation
Contacts INPUT0_0, INPUT01, INPUT02 and
OUTPUT0_0 are identified with the pressure
switch, temperature switch, manual push button,
and motor starter coil, respectively.
001
Input0_0
Input0_1
Output0_0
Input0_2
The format used is similar to that of the hardwired relay circuit
8
PLC example
Mixer Process control
Modifying The Operation
Assume that our original process control circuit
for the mixing operation must be modified such
that the manual push-button control should be
permitted to operate at any pressure but not
unless the specified temperature setting has
been reached
If a relay system were used, it would require
some rewiring of the system, as shown, to
achieve the desired change.
Electrical ladder diagram
120V
Pressure Temperature
switch
switch
Motor
starter
coil
0V (GND)
Overload
relay
M
Manual pushbutton
9
PLC example
Mixer Process control
Modifying the PLC Program
As mentioned, one of the important features of
a PLC is the ease with which the program can
be changed.
If a PLC is used, no rewiring is necessary!
The inputs and outputs are still the same.
All that is required is to change the PLC
program!
001
Input0_0
Input0_1
Output0_0
Input0_2
10
IEC 61131 Standard of PLCs
The great variety of PLC concepts has led to an
incompatibility between the different PLC
platforms and manufacturers
The result was a great effort to be made for
training, hard- and software investments
A standard is needed to standardize the
multiple languages, sets of instructions and
different concepts existing in the field of
automation systems
IEC 61131 standardizes the programming
languages, the interfaces between PLC and
programming system, the sets of instructions
and the handling and structuring of projects
11
IEC 61131 Standard of PLCs
Part 1:
• General information.
Part 2:
• Equipment requirements and tests
Part 3
• Programming languages
Part 4
• User guidelines
Part 5
• Communications
Part 6
• Functional safety
Part 7
• Fuzzy logic programming
Part 8
• Guidelines for the application and implementation of programming languages
Part 9
• Single-drop digital communication interface for small sensors and actuators
Part 10
• XML exchange formats for programs according to IEC 61131-3
12
Benefits of IEC 61131 Standard
Uniform standardized programming languages
Manufacturer independent programming
Open interfaces in programming systems
Systems can be compared easily
Portability of programs on different hardware
Shorter retraining and familiarization times
Fewer errors as a result of standard function blocks
Clear interface definitions
International acceptance
13
IEC 61131-3 Standard (Programming Languages)
IEC 61131-3 defines syntax of 5 programming languages
which can be differentiated by physical appearance into
2 textual languages and 3 graphical languages
Textual languages:
◉ Instruction List (IL)
◉ Structured Text (ST)
Graphical languages:
◉ Ladder Diagram (LD)
◉ Sequential Function Chart (SFC)
◉ Function Block Diagram (FBD)
14
IEC 61131-3 Standard (Programming Languages)
Textual languages
Instruction List (IL)
Structured Text (ST)
15
IEC 61131-3 Standard (Programming Languages)
Graphical
languages
Ladder Diagram (LD)
Sequential Function Chart
(SFC)
Functional Block Diagram
(FBD)
16
Ladder Diagram and Boolean Mnemonic Language
Electrical ladder diagram
0V (GND)
24V
1LS
2LS
SOL 1
Boolean logic
Q0_0 = I0_1 . I0_2
PLC ladder diagram
I0_1
I0_2
Q0_0
()
Structured Text
LD
I0_1
AND
I0_2
ST
Q0_0
17
Ladder Diagram and Boolean Mnemonic Language
PLC ladder diagram
Electrical ladder diagram
0V (GND)
24V
3LS
4LS
I0_3
SOL 2
Q0_1
()
I0_4
Boolean logic
Q0_1 = I0_3 +
I0_4
Structured Text
LD
I0_3
OR
I0_4
ST
Q0_1
18
Ladder Diagram and Boolean Mnemonic Language
Electrical ladder diagram
24V
5LS
6LS
1CR1
Boolean logic
Q0_2 = (I0_5 + I0_6) . IR0
PLC ladder diagram
0V (GND)
I0_5
IR0
Q0_2
()
SOL 3
I0_6
Structured Text
LD
I0_5
OR
I0_6
AND
IR0
ST
Q0_2
19
Ladder Diagram and Boolean Mnemonic Language
24V
Electrical ladder diagram
1PB
1CR1
0V (GND)
PLC ladder diagram
I0_1
2CR1
IR1
Q0_3
()
1CR
I0_2
7LS
IR0
Boolean logic
Q0_3 = [(I0_1 . IR0) + I0_2] . IR1
Structured Text
LD
I0_1
AND
IR0
OR
I0_2
ANDN
IR1
ST
Q0_3
20
Ladder Diagram and Boolean Mnemonic Language
Boolean logic
Q0_4 = (I0_7 + I1_0) . (IR0 +
IR1)
PLC ladder diagram
Electrical ladder diagram
0V (GND)
24V
10LS
11LS
1CR2
2CR2
I0_7
SOL 4
I1_0
IR0
IR1
Q0_4
()
Structured Text
LD
I0_7
OR
I1_0
ST
VAR1
LD
IR0
OR
IR1
AND
VAR1
ST
Q0_4
21
22
Review Questions
What impact does the incompatibility between different PLC
platforms and manufacturers resulted in?
A great effort to be made for training, hard- and software
investments
What is the IEC 61131 Standard of PLCs?
IEC 61131 standardizes programming languages, interfaces
between PLC and programming system, sets of instructions
and handling and structuring of projects
Name the types of programming languages in IEC 61131-3
Standard
Textual languages
Graphical languages
Instruction List (IL)
Structured Text (ST)
Ladder Diagram (LD)
Sequential Function Chart (SFC)
Function Block Diagram (FBD)
Recap Questions
List the benefits of having the IEC 61131 Standard of PLCs
Uniform standardized programming languages
Manufacturer independent programming
Open interfaces in programming systems
Systems can be compared easily
Portability of programs on different hardware
Shorter retraining and familiarization times
Fewer errors as a result of standard function blocks
Clear interface definitions
International acceptance
Lecture 11
Familiarization With The Operation And Basic
Programming Of Timer & Counter Instructions
In this session, you will be introduced to:
1 Representations of contacts and coils in PLC logic ladder diagram
2
Familiarization with the operation and basic programming of Latch instruction
3
Familiarization with the operation and basic programming of Timer instruction
4 Familiarization with the operation and basic programming of Counter instruction
2
Contact & Coil Instructions
Normally-open contact
○ If the status bit is 1 (on), then the instruction is TRUE
○ If the status bit is 0 (off), then the instruction is
FALSE
Normally-closed contact
○ If the status bit is 1 (on), then the instruction is
FALSE
○ If the status bit is 0 (off), then the instruction is TRUE
Output coil
○ The status bit of the addressed Output Coil
instruction is set to 1 (on) when the rung is TRUE
○ The status bit of the addressed Output Coil
instruction is set to 0 (off) when the rung is FALSE
()
3
Latch instruction
Latching circuit
Set and Reset instructions can be
represented as the PLC ladder diagram
PLC ladder diagram
SET
RESET
Q0_0
()
Q0_0
Hold in
Feedback contact
4
Latch instruction
Latching circuit
Latching can also be executed using Set Coil (-(S)--) and Reset Coil (--(R)--) instructions
5
Timer instruction
It is an instruction that waits a set amount of time before doing something
2 things are required before using timers:
What will enable the timer (e.g. an input connected to I0_0 )
How long we want to delay before we react (e.g. waiting for 5 s before turning on the
solenoid)
6
Types of timer instruction
On-delay timer
"Delays turning on"
Most common timer
Off-delay timer
"Delays turning off"
Less common than the on-delay type
Retentive or accumulating timer
Needs 2 inputs (start & reset)
Holds or retains the current elapsed time when the sensor turns off in mid-stream
7
Timer ON-Delay (TON)
Paramete
r
Data
types
Description
IN
BOOL
If a rising edge is detected, the
on-delay timing is started.
PT
TIME
preset time interval for the delay
Q
BOOL
TRUE if IN = TRUE and ET >= PT
FALSE if IN = FALSE and ET < PT
ET
TIME
elapsed time interval
8
Timer ON-Delay (TON)
Timing Diagram of TON Behaviour Over
Time
◎
The function block TON (timer on-delay) is used to
generate switch-on signal delays.
◎
After the start via a 1-signal at input IN, output Q
does not assume value 1 until the time specified
at input PT has expired, and retains this until input
signal IN returns to 0.
◎
If the duration of the input signal IN is shorter than
the specified time PT, the value of the output
remains at 0
9
Timer OFF-Delay (TOF)
Paramete
r
Data
types
Description
IN
BOOL
If a falling edge is detected, the
off-delay timing is started.
PT
TIME
preset time interval for the delay
Q
BOOL
TRUE if IN = TRUE and ET < PT
FALSE if IN = FALSE and ET >= PT
ET
TIME
elapsed time interval
10
Timer OFF-Delay (TOF)
Timing Diagram of TOF Behaviour Over
Time
◎
TOF (timer off-delay) is the name of the function
block for a Switch-off signal delay.
◎
The timer is started via a 1-signal at input IN. At
the same time, the output signal Q assumes the
value 1.
◎
After the input signal IN has reverted to the value
0, the output remains at 1 for the duration PT and
does not return to the value 0 until this has
expired.
11
Basic Timer Applications
OUTPUT 0_0 will only turn on if INPUT 0_0 is held
on for at least 15s.
◎
OUTPUT 0_0 will turn off immediately when INPUT
0_0 is released.
INPUT0_0
OUTPUT0_0
15 s
12
Extending Timers
One timer might not be sufficient to count the whole duration. In
such cases a second timer is required.
Examples of time
specification:
•
T#2h15m
•
t20s
•
T#10M25S
•
t#3h_40m_20
s
Permissible unit
of time :
d
= Day
h
= Hour
m
= Minute
s
= Second
ms
=
Millisecond
INPUT0_0
1800 s
OUTPUT0_0
13
Counter Instructions
A counter is intended to do one simple thing: count
Applications:
○ The number of bottles passing along a conveyor
○ The number of revolutions of a shaft
○ The number of faults in a machine
3 things are required:
○ Where the pulses are coming from (e.g. a sensor connected to input X0)
○ How many pulses do we want to count before we react. (e.g. 5 toys before we box
them)
○ When/how will we reset the counter so that it can count again
14
Counter Instruction
Video
◎
How mechanical counters work (3m 43s)
◎
https://www.youtube.com/watch?v=rjWfIiaOFR4
15
Types of counter Instruction
Up-counters (CTU)
○
They only count up 1,2,3...
Down-counters (CTD)
○
They only count down 9,8,7,...
Up-down counters (CTUD)
○
They count up and/or down 1,2,3,4,3,2,3,4,5,...
High-speed counters
○
Real additional module connected to PLC
○
Counter frequency in excess of 50 Hz, i.e. more than 50 events are counted per
second
○
Are not dependent on scan time
16
UP-Counter (CTU)
This counter function block counts upParamete
Description
r
Data
types
CU
BOOL
If a rising edge is detected, CV is
increased by one
RESET
BOOL
If TRUE, the counter is initialized
with 0
If FALSE, counting is enabled
PV
INT
preset value
Q
BOOL
TRUE if CV = PV
CV
INT
counter result
17
UP-Counter (CTD)
This counter function block counts down
Paramete
Description
r
Data
types
CD
BOOL
If a rising edge is detected, CV
decrements by one.
LOAD
BOOL
If TRUE the counter is initialized
with PV.
If FALSE counting is enabled.
PV
INT
preset value
Q
BOOL
TRUE if CV = PV
CV
INT
counter result
18
UP-Counter (CTUD)
Paramete
r
Data
types
Description
BOOL
If a rising edge is detected, CV is
increased by one.
CD
BOOL
If a rising edge is detected, CV
decrements by one.
RESET
BOOL
If TRUE the counter is initialized
with 0.
If FALSE counting is enabled.
LOAD
BOOL
If TRUE the counter is initialized
with PV.
If FALSE counting is enabled.
PV
INT
preset value
QU
BOOL
TRUE if CV = PV
QD
BOOL
TRUE if CV = 0
CV
INT
counter result
This counter function block can count both
CU
up and down
19
Counter Instruction
OUTPUT 0_0 will only turn on after registering 10
counts of INPUT 0_0
Input0_0
…...
10 counts
Input0_1
Output0_0
20
Extending counts beyond one counter
In some cases, one counter is not sufficient to
register the number of counts.
21
Extending counts beyond one counter
In some cases, one counter is not sufficient to
register the number of counts.
CTU_1 reset by Input0_1 OR IR1 OR IR2
CTU_1
100 counts
100 counts
CTU_2
200 counts
Output0_0
20000 counts
22
Extending time delay with counter
A timer and counter can be designed to be used together.
23
Extending time delay with counter
Output0_0 will turn on after 10 x 5s = 50s
Input0_0
Input0_1
5s
5s
TON_1 / IR1
Output0_0 /
IR2
……...
10 counts
24
Review Questions
Given the PLC ladder diagram below, draw the timing diagram for Output0_0
(Answer on next slide)
Recap Questions
Given the PLC ladder diagram below, draw the timing diagram for Output0_0
(Answer)
Input0_0
Output0_0
0s
5s
10s
15s
20s
Lecture 12
Familiarization With The Operation And Basic Programming Of
R_TRIG / F_TRIG & Shift Register Instructions
In this session, you will be introduced to:
1 Familiarization with the operation and basic programming of
R_TRIG / F_TRIG instructions
2
Familiarization with the operation and basic programming of Shift Register
instruction
2
Signal edge detection
◎
Signals reaching the inputs via sensors are evaluated as 0
or 1 signals by the CPU of the PLC, whereby the duration
of signal statuses 0 and 1 is determined by the sensor. For
instance: A 1-signal applies for as long as a push button is
pressed, otherwise a 0-signal is received.
◎
In many cases, however, it is not the signal itself which
matters, but the exact instant, during which the signal
changes. This type of signal change is termed Edge
Rising edges mark the instants, in which a signal level changes
from 0 to 1.
Falling edges mark the exact instants, when a signal level
changes from 1 to 0.
◎
◎
3
Latch instruction
Function of R_TRIG
○
R_TRIG (rising) is used for the detection of
rising edges.
○
Its output Q has the value 1 from one
execution of the function block to the next, if
its input CLK (Clock for pulse) changes from
0 to 1.
4
Latch instruction
Function of F_TRIG
○
F_TRIG (falling) is used for the detection of
falling edges.
○
Its output Q has the value 1 from one
execution of the function block to the next, if
its input CLK (Clock for pulse) changes from
1 to 0.
5
Function of R_TRIG / F_TRIG
Explanation:
◎
Q0_0 goes ON for only one scan when the
leading edge of I0_0 is detected.
◎
Q0_1 goes ON for only one scan when the
trailing edge of I0_1 is detected
I0_0
X0
I0_1
X1
Q0_0
Y0
Q0_1
Y1
6
Rising Edge Detection (R_TRIG) Application
When the sensor S1 detects a roller
passing through, it will send a signal to the
control to dissipate oil for 10s. Design a
program that can control this function.
Sensor S1 is connected to INPUT 0_0 and
the oil dispenser is connected to OUTOUT
0_0.
S
1
7
Rising Edge Detection (R_TRIG) Application
Program
8
Rising Edge Detection (R_TRIG) Application
Sequence 1: INPUT 0_0 is activated when it detects the
roller. It will trigger a rising edge response.
S
1
S1
0
1
9
Rising Edge Detection (R_TRIG) Application
Sequence 2: The R_Trig1 will create a short pulse through R_TRIG1.Q. It will activate IR0 in
Rung 1.
10
Rising Edge Detection (R_TRIG) Application
Sequence 3.1 : IR0 in rung 2 will be activated.
11
Rising Edge Detection (R_TRIG) Application
Sequence 3.2: Output0_0 will be activated.
12
Rising Edge Detection (R_TRIG) Application
Sequence 3.4: Since R_TRIG1.Q will only be turned on for a short pulse, it will stop activating
IR0.
13
Rising Edge Detection (R_TRIG) Application
Sequence 3.5: OUTPUT0_0 will also turn on a TON timer which will count for 10s.
Sequence 3.1 to 3.5 occurs momentarily (at the same time).
14
Rising Edge Detection (R_TRIG) Application
Sequence 4.2: Normally closed contact T1 will be activated. The contact will be opened.
15
Rising Edge Detection (R_TRIG) Application
Sequence 4.3: The opened contact will cut off supply to
OUTPUT0_0.
S
1
S1
0
1
16
Rising Edge Detection (R_TRIG) Application
Sequence 4.4: There be no supply to coil T1. Contact T1 will
therefore be deactivated and remain in closed position.
Sequence 4.1 to 4.4 occurs momentarily (at the same time).
S
1
S1
0
1
17
Rising Edge Detection (F_TRIG) Application
◎
An ultrasonic switch S1 is employed to detect the presence
of an approaching vehicle. A through-beam sensor S2
detects the passing of a vehicle via the interruption of the
light beam. In response to these input signals, the control
circuit controls the output that drives the motor of the door
for opening and closing. Output0_0 is connected to SOL1
which raises the gate and OUTPUT0_1 is connected to SOL2
which lowers the gate. The upper and lower limit switch is
connected to INPUT0_2 and INPUT0_3 respectively.
S1
S2
18
Rising Edge Detection (R_TRIG) Application
◎
Sequence 1.1: As the lorry approaches the gate, it
activates sensor S1. Sensor S1 will turn on INPUT0_0.
INPUT0_3 will be activated since it detects the lower limit
of the gate.
S1
S1
S1
0
1
19
Rising Edge Detection (R_TRIG) Application
◎
Sequence 1.2: INPUT0_2 will not be activated as the
gate has not reached its upper limit. It will turn activate
OUTPUT0_0 which will turn on SOL1 to raise the gate.
S1
S1
S1
0
1
20
Rising Edge Detection (R_TRIG) Application
◎
Sequence 1.3: OUTPUT0_0 will latch, memorize itself
S1
S1
S1
0
1
21
Rising Edge Detection (R_TRIG) Application
◎
Sequence 1.4: Sensor S2 connects to INPUT0_2. It will
be activated once the lorry passes through. Sequence 1.1
to 1.4 occurs momentarily, almost at the same time.
S1
0
1
S2
S2
22
Rising Edge Detection (R_TRIG) Application
◎
Sequence 2: Once the gate reaches the upper limit, it will
activate INPUT0_2. Since INPUT0_2 is normally closed, it
will open upon activated. This will turn off OUTPUT0_0. The
gate will stop raising
S1
S2
1
S2
23
Rising Edge Detection (R_TRIG) Application
◎
Sequence 3.1: Once the lorry passes through the gate,
there will be a falling edge signal in S2. This will turn on
F_TRIG1.Q for a short pulse.
S1
S2
1
0
S2
S2
24
Rising Edge Detection (R_TRIG) Application
◎
Sequence 3.1: Once the lorry passes through the gate,
there will be a falling edge signal in S2. This will turn on
F_TRIG1.Q for a short pulse.
S1
S2
0
S2
25
Rising Edge Detection (R_TRIG) Application
◎
Sequence 3.3: Input rung of IR1 will be activated
S1
S2
26
Rising Edge Detection (R_TRIG) Application
◎
Sequence 3.4: INPUT0_3 is to detect the lower limit of the
gate. Since the gate is at the upper limit, it will not be
activated. OUTPUT0_1 will be activated. It will turn on SOL2
which will lower the gate
S1
S2
27
Rising Edge Detection (R_TRIG) Application
◎
Sequence 3.5: OUTPUT0_1 latch, memorizes itself
S1
S2
28
Rising Edge Detection (R_TRIG) Application
◎
Sequence 3.6: Once the gate starts to lower. It will not
activate INPUT0_2 anymore. Sequence 3.1 to 3.6 occurs
almost momentarily, at the same time
S1
S2
29
Rising Edge Detection (R_TRIG) Application
◎
Sequence 4: The gate lowers until it hits the lower limit
switch which will cut off supply to OUTPUT0_1
S1
S2
30
31
Recap Questions
Explain the function of the R_TRIG instruction
R_TRIG instruction is used for the detection of rising edges. Its
output Q has the value 1 if its input CLK changes from 0 to 1
Explain the function of the F_TRIG instruction
F_TRIG instruction is used for the detection of falling edges. Its
output Q has the value 1 if its input CLK changes from 1 to 0
What is the Shift Register instruction commonly used for?
Shift Register instruction is used to store the status of an event
that has previously happened, and make use of the stored status
to activate other events
Lecture 13
Demonstration Of Development And Implementation Of A PLC
Ladder Program Using An Example Of An Electro-pneumatic System
In this session, you will be introduced to:
1 Systematic Approach to Designing Control System using PLC
2
Guidelines for PLC selection
3
Designing of PLC ladder
2
Systematic Approach to Designing Control System
Phase Model of PLC software generation:
•
Specification: Description of the task
•
Design: Description of the solution
•
Realisation: Implementation of the solution
•
Integration/commissioning: Incorporating into
environment and testing the solution
3
Guidelines For PLC Selection
Define system requirements:
○ Understand the control process
○
Determine size and type of I/Os
◉
◉
○
This specifies the number of I/O devices that can be connected to
the controller. There should be sufficient I/O ports to meet present
requirements with enough spares to provide for moderate future
expansion.
Each output port should be capable of supplying sufficient voltage
and current to drive the output peripheral connected to it.
Determine type of software features required e.g. ladder diagram,
statement list, grafcet-type programming
4
Guidelines For PLC Selection
○
Estimate memory size and determine type of memory required (RAM,
EPROM, or EEPROM)
◉
The amount of memory required for a particular application is
related to the length of the program and the complexity of the
control system. Simple applications having just a few relays do
not require significant amount of memory. Program length tend to
expand after the system have been used for a while.
◉
It is advantageous to a acquire a controller that has more memory
than is presently needed.
○
Determine if there is a need for special modules e.g. high speed
counters, communication facilities or dedicated process controllers
○
Determine environment in which PLC will have to operate
5
Specification Phase
(Description of Control Task / Positional sketch)
◎
Two clips are to be riveted together on a semi-automatic press.
Components and rivet are positioned by hand and then removed by hand
on completion of the riveting operation. The automated part of the cycle
consists of holding and clamping of the components (cylinder A) and also
riveting (cylinder B), and the cycle should be performed ending at the
starting position after operating a start button.
Figure 1: Positional sketch of
riveting press
6
Design Phase
Pneumatic Circuit
A
SOL 1
a0
B
a1
SOL 2
b0
b1
SOL 3
7
Design Phase
Abbreviated representation of motion and actuation signals
1PB
2LS
3LS
4LS
A+ B+ BIR1
IR2
+
IR3
1LS
AIR4
8
Design Phase
Displacement-step diagram
2LS
1
Cylinder A
0
1
1PB
1LS
4LS
Cylinder B
0
3LS
9
Design Phase
1
1LS
0
1
2LS
0
1
3LS
0
1
4LS
0
1
1PB
0
10
Design Phase
INPUTS
OUTPUTS
Address
Device
Address
Device
Input0_0
S1
Output0_0
1SOL (A+/A-)
Input0_1
a0
Output0_1
2SOL (B+)
Input0_2
a1
Output0_2
3SOL (B-)
Input0_3
b0
Input0_4
b1
11
Realization Phase
12
Video
https://www.youtube.com/watch?v=Qf32qtHfowQ
What are the Most Popular PLC Programming Languages? (9m 30s)
13
Comissionning Phase
Programming into memory
Check for any coding error by means of diagnostic function
Running the system
Ensure I/O wirings are correctly connected according to I/O
assignment
Troubleshooting of system
Check PLC status Indicators
HALT - something has stopped the CPU
RUN - the PLC thinks it is OK (and probably is)
ERROR - a physical problem has occurred with the PLC
Check indicator lights on I/O cards and sensors
14
15
Lecture 14
Human Machine Interface
In this session, you will be introduced to:
1
What is the purpose of a Human Machine Interface
2
Common Hardware Configuration
3
The key elements of an effective Human Machine Interface.
2
Purpose of Human Machine Interface
Optimize Industrial processes by:
1. Centralizing data for user
2. Being the Interaction platform between user and process
3. Coordinating and controlling the industrial processes
3
Purpose of Human Machine Interface
The HMI achieves its purposes by allowing users to:
1. View important information in the form of
◉ Graphs
◉ Charts
◉ Dashboards
2. Manage Alarms
3. Connect with ‘Supervisory Control and Data Acquisition’ and Manufacturing
Execution Systems
4
Purpose of Human Machine Interface
The HMI usually works by receiving feedback from and giving instructions to
PLCs
Enterprise Level: Enterprise Resource Planning
Plant Level: Manufacturing Execution System
Supervisory Level: Supervisory Control and Data Acquisition
Operation Level: Programmable Logic Controller
Human Machine
Interface
Field Level: Sensors and Actuators
5
Purpose of Human Machine Interface
Classification of HMIs
Push Button Replacer
• Centralize all physical inputs into one screen
• Eliminates as much physical devices as possible
Data Handler
• Process and display data into visual representations. Eg. Graphs, time based
charts
Overseer
• Oversee operations
• Provide trending, diagnostic data and management information
6
Common Hardware Configuration
RS232/RS422/RS485 has been a common standards used for communication of
signals between PLC and HMI.
Pin
Description
1
Data Carrier Detect
2
Receive Data
3
Transmit Data
4
Data Terminal Ready
5
Ground
6
Data Set Ready
7
Request to Send
8
Clear to Send
9
Ringing Indicator
7
Common Hardware Configuration
There are slight differences among RS232, RS422, RS485.
RS232 and RS422 are full duplex while RS485 is half duplex.
Other differences include maximum cable length, data transmission speed and
sensitivity
8
Common Hardware Configuration
USB ports has also been introduced in the recent years
A
B
9
Common Hardware Configuration
The latest communication protocol used is RJ45 port
10
Common Hardware Configuration
The current width diagonal width ranges from 3” to 21”
11
Common Hardware Configuration
Capacitive touch screen is currently the common technology for detection of
human input.
12
Is Data Information?
How can we improve it?
Blood test results
Sugar
0
4
6
10
Result
200
Result
5
Salt
hemoglobin
LDL Cholesterol
0
135
Time
145
142
0
17
12
Time
20
Result
150
Result
15
0
100
80
Time
92
HDL Cholesterol
0
50
Time
150
70
Result
57
Triglycerides
0
80
Time
100
112
150
Result
Time
What did we learn from the different
representations?
Data does not equate to information.
Data is raw unorganized facts that needs to be
processed. Information is processed, organized,
structured or presented in a given context so as
to make it useful.
Data
Sugar
5 mmol/L
Information
0
4
6
5
10
What did we learn from the different
representations?
Values in Analog Indicators are better represented.
Analog indicators give a magnitude to the
presentation of the information.
Shows the healthy range.
Data
Sugar
Healthy
Information
0
4
6
5
Shows the diagnosed value as compared to the healthy range.
10
What did we learn from the different
representations?
Show boundary conditions and limits.
Give an indication what are the upper and lower
limits.
Shows the upper and lower limits of the healthy range.
Data
Sugar
Healthy
Information
0
4
6
10
5
Shows the possible upper and lower limits of the analyzed data.
What did we learn from the different
representations?
If possible, give historical trends.
Give an indication if the result is getting better
or worse.
Data
Sugar
Healthy
Information
Result
Time
Color scheme
Proper selection of color schemes can enhance effectiveness in using
the Human Machine interface.
A color chart can be used as a reference.
Color scheme
The choice of the color scheme should depend on the meaning purpose of
the indication.
Vary the color scheme according to the purpose of the indication but do not
use excessive color schemes.
Process 1
completed
Process 1
completed
Start
Start
Stop
DANGER!
DANGER!
Display 1
Stop
Display 2
Which one is a better choice?
Form factor of display
Vary the shapes and size of the display according to the information.
Process 1
completed
Start
Process 1
completed
Stop
Stop
Start
DANGER!
Display 1
Display 2
Which one is a better choice?
Balance of information
Some HMIs are too clustered. Do not pack the screen with:
Excessive color schemes
Improper usage of colors cause discomfort for the end user.
Excessive information
There is limited amount of information the human eye can
process within a specific time.
Unnecessary graphics and interfaces
Extra graphics can be too distracting for the user.
Balance of information
Is there a problem with each of them?
No copyright infringement is intended
Balance of information
Is there a problem with each of them?
No copyright infringement is intended
Balance of information
Is there a problem with each of them?
No copyright infringement is intended
Balance of information
Is there a problem with each of them?
No copyright infringement is intended
Balance of information
If there are too much information, what do you do?
Use tabs
Balance of information
If there are too much information, what do you do?
Use tabs
Process 1
Process 2
Process 3
Process
1
complete
d
Process
2
complete
d
Process
3
complete
d
Start 1
Start 2
Start 3
Process
1
completed
Stop 1
Stop 2
Stop 3
Start 1
Stop 1
Balance of information
If there are too much information, what do you do?
Create drop down bars
Balance of information
Tabs and drop down bars can be used for different groups
of users who needs different group of information
Operator
Technician
Manager
User
Feedbac
k
Operator
Process
1
completed
Start 1
Stop 1
Process
1
completed
Technician
Manager
Start 1
Stop 1
User Acceptance Testing.
After the creation of the HMI:
Find our areas in which errors are made.
Allow end users to provide feedback.
Categorize the feedback constructively.
Guide to a good HMI
Show what the user needs
Keep things simple
Use tabs for multiple windows
Do not overuse colours
Be the user yourself
Translate data into information that is relevant to the user.
There is a limit in the amount of information that can be processed
within a short span of time.
Group information into the categories they are presented.
Too many colours can be distracting.
Find out how the user will like to your HMI.
Common Hardware Configuration
Capacitive touch screen is currently the common technology for detection of
human input.
32
Systematic Approach to Designing Control System
Phase Model of PLC software generation:
•
Specification: Description of the task
•
Design: Description of the solution
•
Realisation: Implementation of the solution
•
Integration/commissioning: Incorporating into
environment and testing the solution
36
Lecture 15
Technological Advancement in Industrie 4.0
In this session, you will be introduced to:
1
The possible impact of Industrie 4.0
2
Other similar technological shifts
3
The paradigm shift of future jobs
2
In this
session,
you will be
introduced
to:
The possible impact of
4th Industrial Revolution.
Other similar
technological shifts.
The paradigm shift of
future jobs.
4th Industrial Revolution
As recapped from the 1st
lecture of the semester. 4th
Industrial revolution is
characterized by machines that
are
More effective and efficient
production and workflow
Lower costs
Connectivity
Supplement tasks that is less
The 4th Industrial revolution in different
countries
How Germany calls it
• Industrie 4.0
How France call it?
• Industrie du futur (Industry of the future)
How China calls it?
• Made in China 2025
How Singapore calls it?
• Smart Nation
Video
What is Industry 4.0? (1m 30s)
https://www.youtube.com/watch?v=RPC7yo99Nxs
Video
Smart Nation - Transforming Singapore Through Technology (1m 30s)
https://www.youtube.com/watch?v=NeCfOzAiYcE&list=PLmGkYf0auQJyhg7DmHJZuXQrCWNw_
qd9D
4th Industrial Revolution
th
Key principles in 4 Industrial
Revolution.
Interoperability
• Ability of systems to connect, work and
transact with other systems without extra
effort from the user.
Information
transparency
• Allows operators to collect immense
amounts of data and information from all
points in the chain.
Technical
assistance
• Shifts from the role of humans from
operators of equipment to strategic
decision makers with flexible capabilities.
Decentralized
decisions
• Cyber-physical subsystems should be able
to independently make decisions and
continue on with their dedicated
functionalities.
4th Industrial Revolution
th
Building Blocks in 4 Industrial
Revolution.
Credit to BCG.
4th Industrial Revolution
Inter-operability
◎ Internet of Things
○
Sensor networks
○
Machine learning
○
Semantics
4th Industrial Revolution
Information Transparency
Digital twin
◉ Simulation of
physical
environment in
virtual world
Digital Shadow
◉ Information trace of
web browsing.
4th Industrial Revolution
Technical Assistance
Robotics
◉
Collaborative Robots
◉
◉
Smart factories
Dark factories
Automation
4th Industrial Revolution
Decentralized decisions
Autonomous machines
◉ Vehicles
◉ Robots
Artificial Intelligence
◉ Deep Learning
◉ Neural Networks
Industrie 4.0 in industry
Manufacturing Execution System
Connects, monitors and
controls complex
manufacturing systems and
data flows on the factory floor.
tracks and gathers
accurate, real time data about
the complete production
lifecycle, beginning with order
release until the product
Industrie 4.0 in industry
Manufacturing Execution System
http
s://medium.com/world-of-iot/92-what-is-the-five-layer-automation-pyramid-d0ccc
Industrie 4.0 in industry
Credit to Toyota Production System:
toyota-europe.com/world-of-toyota/this-is-toyota/toyota-production-system
Industrie 4.0 in industry
Credit to Nike Customize:
https://www.nike.com/sg/nike-by-you
Industrie 4.0 in industry
Example of Manufacturing Execution System in daily lives
•
•
•
Customer
Payment
Ordering
Collection
•
Staff
Order management
• Scheduling
• Inventory Control
Management
Resource management
Industrie 4.0 in industry
Radio Frequency Identification Device
https://www.epc-rfid.info/rfid
Industrie 4.0 in industry
Radio Frequency Identification Device
High speed
Non Contact
• Able to read without line of sight
• Able to read from distance
Handles lots of information.
Robust
Industrie 4.0 in industry
Credits to EE Times:
https://www.eetimes.com/the-state-of-rfid/
Industrie 4.0 in industry
Radio Frequency Identification Device
Library system in Singapore
Library in the 70s – 80s
Library now
Industrie 4.0 in industry
Radio Frequency Identification Device
Library system in Singapore
Searching for your book?
Borrowing your book?
Returning your book?
Industrie 4.0 in industry
Radio Frequency Identification Device
Library system in Singapore
Wireless technology:
RFID
Computer technology:
Internet
Automation technology:
Robotics
Industrie 4.0 in industry
Augmented Reality
Interactive, reality-based display environment that takes the
capabilities of computer generated display, sound, text and
effects to enhance the user's real-world experience.
In a nutshell
• Overlay virtual world, Into real world, with interactive
capability.
Industrie 4.0 in industry
Augmented Reality
How can it be applied in the industry
• Remote maintenance
Industrie 4.0 in industry
Augmented Reality
How can it be applied in the industry
• Training collaboration
Industrie 4.0 in industry
Augmented Reality
How can it be applied in the industry
• Integration with sensor networks
Industrie 4.0 in industry
Augmented Reality
Commonly know Augmented Reality software:
Industrie 4.0 in industry
Augmented Reality
How can it be applied in daily lives:
Industrie 4.0 in industry
Open Platform Communication Unified Architecture (OPC UA)
Early 1990s:
• Started as Object Linking and Embedding (OLE). Allow data to
be plugged into Microsoft applications.
Around 1995:
• First version of OPC released.
Around 2012
• OPC UA was released.
Industrie 4.0 in industry
Open Platform Communication Unified Architecture (OPC UA)
Scalable
• Can support high end and low end servers.
Industrie 4.0 in industry
Open Platform Communication Unified Architecture (OPC UA)
Encrypted
Industrie 4.0 in industry
Open Platform Communication Unified Architecture (OPC UA)
Internet Capable
Industrie 4.0 in industry
Open Platform Communication Unified Architecture (OPC UA)
Inter-operable
Uses of advanced technology
Bus system in Singapore
Single Deck
• 1 bus driver
• 1 bus conductor
• 1 bus inspector
Double Deck
• 1 bus driver
• 1 bus conductor
Double Deck
• 1 bus driver
???
What will the future bus system be?
What caused the change?
How has technology and automation impact
this?
Uses of advanced technology
Bus system in Singapore
Single Deck (or more)
• No bus drivers , control center moitors the fleet
of advanced technology
Uses
Bus system in Singapore
Will this technology affect other sectors?
Other possibilities?
Security
Guards?
Waiters?
Chefs
Future of all jobs
Will we start losing our jobs?
Future of all jobs
Top 10 skills relevant in Industry 4.0
These are the 10 most promising industrial IoT skills.
Credit to World Economic Forum.
Future of all jobs
Advancement in 4th Industry Revolution only replaces
tasks, not jobs.
To keep one valid in this advancement, we got to update
ourselves to be able to take on new tasks
THANK YOU
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )