QUESTION 4
4.1
Answer:
1. Sequential operation: Sequential circuits ensure that actuators operate in the
correct predetermined order, allowing complex automated operations to be performed
reliably.
2. Improved safety and productivity: Sequential control reduces operator intervention and prevents incorrect actuator operation, resulting in safer and more efficient
production.
4.2
(a) Displacement-step diagram
The required sequence is:
Figure 1: displacement
(b) Pneumatic components required
1. Three double-acting pneumatic cylinders.
2. Three 5/2 directional control valves.
3. One 3/2 normally closed push-button valve.
4. 3/2 roller-operated limit valves.
1
5. Flow-control valves for speed regulation.
6. Air compressor.
7. FRL unit.
8. Pneumatic tubing and fittings.
(c) Working pneumatic circuit
The circuit must produce the following sequence:
A+ → A− B + → C + → B − → C −
(d) Method of reducing the impact speed of Cylinder 3
Answer:
The impact speed of Cylinder 3 can be reduced by installing a one-way flow-control
(throttle-check) valve at the cylinder port to restrict the exhaust airflow and control
the cylinder extension speed.
2