MRI is an acronym for Magnetic Resonance Imaging. It entails the process of
magnetically aligning the hydrogen atoms in a patient and using radio frequencies to
disrupt them and measure variations. This process is useful in detecting cancerous
cells, inflammation, herniated discs in the spine, and other tissue abnormalities. First
implemented in 1977 by Dr Raymond Damadian, the process built on top of
understanding of NMR – an acronym for Nuclear Magnetic Resonance. NMR,
discovered in the 1940s by Felix Bloch and Edward Purcell individually, is the process in
which nuclei placed in a magnetic field absorb and emit radiofrequencies. Dr Raymond
Damadian used the understanding of NMR to theorize that a machine could use this
principle to detect cancer in the body.
An MRI machine consists of many parts that can be summarized into five
categories: the magnet, the gradient coils, the radio frequency transmitter, the radio
frequency receiver coils, and the computer. The magnet most commonly used is a
⃗ =
superconducting electromagnet that produces a magnetic field with a magnitude of 𝐵
1.5𝑇 𝑡𝑜 3 𝑇. The magnet is cooled to 4.2 Kelvin by a liquid helium cryogenic system. The
gradient coils purpose is to warp the magnetic field into a mappable x, y, and z
coordinate plane, where the x and y coordinates describe the patient laying horizontally
inside the machine, and the z axis representing the depth of their presence top to
bottom. The gradient coils then disrupt the alignment of the protons within the hydrogen
atoms within the various tissues of the body, and the gradient coils repeatedly alternate
on and off, realigning the protons. This process is necessary to generate a readable
map and give direction for imaging.
The radio frequency transmitter then pulsates electromagnetic radiation – radio
waves to be exact – to disrupt the alignment of the hydrogen atoms, changing their
magnetization vector. They then quickly realign and emit energy that can be detected.
The radio frequency receiver coils then detect the energy emitted by the realigned
atoms and sends a signal to the computer. The computer compiles all of the data
received in the x, y, and z plane of the tissues being scanned, and produces an image
that can be analyzed for abnormalities.
The first applicable equation for the machine describes the resonate frequency in
megahertz of the magnetic moment of the hydrogen protons in which they rotate. It is
⃗ | This equation states that the resonate frequency is
given by the following: 𝑓0 = 𝛾 |𝐵
equal to the gyromagnetic ratio of hydrogen (42.58 MHz/T) which is a constant;
multiplied by the magnetic field of the superconducting electromagnet, which varies
from 1.5T to 3T based on the machine used.
The second applicable equation for the machine describes the polarization – the
equilibrium magnetization of the protons within the hydrogen atoms within the tissue
being scanned. This equation is calculated before the machine is ran to determine the
quality of the image that can be generated. It is not calculated for each patient, rather it
is a part of the engineering process. Other types of atoms can be analyzed as well,
such as sodium atoms in the brain to detect severity of recent strokes. The formula is
⃗)=
given as follows: 𝑀0 (𝑅
⃗ )𝛾2 ℎ2 𝐵0 (𝑅
⃗)
𝜌(𝑅
4𝜅𝑇
where 𝑀0 is the net magnetic moment times
distance vector giving volume, equal to the spin density of hydrogen (𝜌) times distance
vector, times the gyromagnetic ratio (𝛾 42.58 MHz for hydrogen) squared, times planks
constant (ℎ 6.626𝑥10−34 j/s), times the magnitude of the magnetic field times distance
vector, all divided by 4 times the Boltzman constant (𝜅 1.381𝑥10−23j/k joules per kelvin,)
times T (Temperature of the magnet in Kelvin, 4.2 Kelvin.)
The third applicable equation describes the relaxation of the protons in the
hydrogen atoms within the tissues being scanned. Recall that once they are relaxed,
they release energy absorbed from the electromagnetic radiation and can be measured.
−
𝑡
𝑡
This formula is as follows: 𝑀𝑥𝑦 (𝑡) = 𝑀0 𝑒 𝑇2 as well as 𝑀𝑧 = 𝑀0 (1 − 𝑒 −𝑇1 ). These
formulas describe the exponential rate in which the protons relax in relation to time
divided by T (tissue relaxation constant; 40 ms to 4000 ms depending on tissue
hydrogen density. Bones are less dense, muscles more so.)
An interesting fact about the MRI process – the human body emits heat which
interferes with the imaging, producing a significant amount of noise that must be
cancelled out and ignored. In fact, only 6 out of approximately 1 million protons are
accurately imaged.