____________________________________________________________________________________
How to perform a Buckling analysis of a structure
subjected to gravity load?
Description
The Eigenvalue Buckling analysis in workbench takes the results of a Static Structural and calculates the
load multiplier that would cause a structural buckling.
If in the Static Structural Loads and Gravity are applied together (to take into account of the self-weight of
the structure), then the buckling multiplier would “multiply” also the gravity, which is a non-physical situation.
To avoid this issue, an intermediate Static Structural is required. The final workflow (shown in the figure
below) will be:
1. Static Structural analysis #1: with gravity only to evaluate the deformed configuration of the structure
under its own weight;
2. Static Structural analysis #2: after importing the deformed configuration from the analysis #1 the
Load condition for the buckling study is applied;
3. Eigenvalue buckling analysis, linked to the analysis #2, to calculate the Load Multiplier.
Please refer to the attached model for an example.
© 2019 ANSYS, Inc. All rights reserved.