TECHNOLOGICAL UNIVERSITY (TAUNGGYI) DEPARTMENT OF CIVIL ENGINEERING STUDY ON THE EFFECTS OF VERTICAL GEOMETRIC IRREGULARITY ON RC BUILDING AT DIFFERENT SEISMIC LOCATIONS BY MA THAE THAE SU WIN M.E. THESIS OCTOBER, 2022 TAUNGGYI TECHNOLOGICAL UNIVERSITY (TAUNGGYI) DEPARTMENT OF CIVIL ENGINEERING STUDY ON THE EFFECTS OF VERTICAL GEOMETRIC IRREGULARITY ON RC BUILDING AT DIFFERENT SEISMIC LOCATIONS BY MA THAE THAE SU WIN M.E. THESIS OCTOBER, 2022 TAUNGGYI TECHNOLOGICAL UNIVERSITY (PANGLONG) DEPARTMENT OF CIVIL ENGINEERING We certify that we have examined, and recommend to the University Steering Committee for Post Graduate Studies for acceptance of the Master thesis entitled “STUDY ON THE EFFECTS OF VERTICAL GEOMETRIC IRREGULARITY ON RC BUILDING AT DIFFERENT SEISMIC LOCATIONS” submitted by Ma Thae Thae Su Win, Roll No. ME.C 1 (December, 2019) to the Department of Civil Engineering as the requirements for the degree of Master Engineering (Civil Engineering). Board of Examiners: 1. Daw Su Su Htwe M.E (CWRE), MTU Associate Professor and Head Department of Civil Engineering Technological University (Taunggyi) 2. …………………………........ (Chairman) Daw Phyoe Hnin Thu Htun M.E (Civil), TU (Thanlyin) Deputy Director Department of Advance Science and Technology …………………………........ Ministry of Science and Technology 3. (Supervisor) U San Lwin M.E (Civil), MTU Head (Engineer) Estate Engineering Department Technological University (Taunggyi) …………………………........ (Co-supervisor) 4. Dr. Kyaw Moe Aung M.E (Civil) YTU; Ph.D (Civil) MTU Professor Department of Civil Engineering Technological University (Kyaukse) ……………………………….. (External Examiner) i ACKNOWLEDGEMENTS First and foremost, the author would like to bring her gratitude to Dr. Khin Htike Htike Lwin, Rector of Technological University (Taunggyi) who gives invaluable permission to submit the thesis for the degree of Master of Engineering. The author is extremely thankful and pay her gratitude to the Chairman of the Board of Examiners, Daw Su Su Htwe, Associate Professor and Head of the Department of Civil Engineering of Technological University (Taunggyi), for her valuable management, support and guidance. The author would like to express her deepest thank to her supervisor, Daw Phyoe Hnin Thu Htun, Deputy Director, Department of Advance Science and Technology, Ministry of Science and Technology for her support, valuable suggestions, encouragement, kind supervision at every stage in her research work and editing this study. It is honour to work under her supervision. The author is deeply grateful to her co-supervisor U San Lwin, Associate Professor of the Estate Engineering Department of Technological University (Taunggyi), for his enthusiastic instruction, advice and encouragement for successful completion of this thesis. The author’s acknowledgement is also extended to the respectful member of the Board of Examiner, Daw Kay Thi Win, Associate Professor of the Department of Civil Engineering of Technological University (Taunggyi), for her kindly support and helpful suggestions. The author is extremely grateful to all teachers of the Department of Civil Engineering of Technological University (Taunggyi), for their support and suggestions throughout this thesis. The author is deeply grateful to her beloved parents for their noble support, encouragement and lovely kindness to attain her destination without any trouble. Finally, the author is deeply grateful to all the persons who have helped towards the successful completion of this study. ii ABSTRACT Earthquakes have been happened more frequently in Myanmar recently, the risk from them is worrisome. Therefore, earthquake load plays in main role in the design of RC building, the seismic design for these irregular buildings has to be carefully considered to lessen the earthquake risks. The purpose of this study is to compare the structural behaviours of vertical geometric irregularity of the same structural sizes under four different seismic locations: Bago, Taunggyi, Nay Pyi Taw and Yangon using ETABS 2016 software. And then, the optimum member sizes at each seismic location are investigated. In this study, the 15-storied RC building with vertical geometric irregularity at all locations is modelled and analysed with dynamic analysis (response spectrum analysis) in the ETABS 2016 software and the stability checks are made. The considerations of loading requirements are based on MNBC 2020 and ASCE 7 - 05 and code requirements for the structural elements are according to ACI 318-08. Concrete compressive strength (fc′) is used 4000 psi and reinforcing yield strength (fy) is used 60000 psi. In comparing the structural behaviours of the structure at different seismic location, the member sizes are of the same sizes as each other and the buildings are checked for storey drift, P-Δ effect, overturning moment, torsional irregularity and soft storey by using response spectrum analysis. Stability checks for all the buildings are satisfied. The comparison among the buildings of different seismic location is carried out based on structural behaviours such as storey drift, storey shear, storey displacement and the behaviour of structural members at setback. According to the study, the behaviour of the structure largely depends on the seismic parameters of the locations. According to the comparison of the structural behaviours, it is obvious that the building at Bago experienced larger storey drift, storey shear, storey displacement, shear forces and bending moment than the buildings at all other locations in this study where the seismic parameters are smaller. According to the results, members at setback suffer from the seismic effects more than other members. iii TABLE OF CONTENTS Page ACKNOWLEDGEMENTS i ABSTRACT ii TABLE OF CNTENTS iii LIST OF FIGURES vii LIST OF TABLES ix LIST OF SYMBOLS xii CHAPTER 1 2 TITLE INTRODUCTION 1 1.1. General 1 1.2. Objectives of the Study 2 1.3. Scopes of the Study 2 1.4. Implementation Programme 3 1.5. Outlines of the Study 4 LITERATURE REVIEW 5 2.1. General 5 2.2. Introduction 5 2.3. Response of High-rise RC Building During Earthquake 6 2.4. Seismology of Myanmar 8 2.5. Member Considerations 8 2.6. Loads and Forces 10 2.6.1. Dead Loads 10 2.6.2. Live Loads 10 2.6.3. Wind Load 11 2.6.4. Earthquake Forces 11 2.7. 2.6.4.1. Seismic Base Shear 12 2.6.4.2. Calculation of Seismic Response Coefficient 12 Structural analysis 13 2.7.1. Static Analysis 13 2.7.2. Dynamic Analysis 14 2.7.2.1. Time History Analysis 14 iv 2.7.2.2. Response Spectrum Analysis 2.8. 2.9. 15 Types of Lateral Load Resisting Systems 16 2.8.1. Shear Walls 16 2.8.2. Moment Resisting Frame 18 2.8.3. Braced Frame 20 Seismic Force-Resisting Systems 21 2.9.1. Bearing Wall Systems 21 2.9.2. Building Frame Systems 22 2.9.3. Moment Resisting Frame Systems 22 2.9.4. Dual Systems 23 2.9.5. Shear Wall-Frame Interactive with Ordinary Reinforced Concrete Moment Frames and Ordinary Reinforced Concrete Shear Walls 2.10. 24 Irregularities in Structures 24 2.10.1. Plan (Horizontal) Structural Irregularities 24 2.10.1.1. Torsional irregularity 25 2.10.1.2. Re-entrant corner irregularity 26 2.10.1.3. Diaphragm discontinuity irregularity 27 2.10.1.4. Out-of-plane offsets irregularity 28 2.10.1.5. Nonparallel systems irregularity 28 2.10.2. Vertical Irregularity 28 2.10.2.1. Stiffness irregularity – soft storey 29 2.10.2.2. Weight irregularity 29 2.10.2.3. Vertical geometric irregularity 30 2.10.2.4. In-plane discontinuity in vertical lateral-force resisting elements 2.11. 30 2.10.2.5. Weak storey 31 Stability Checking of Superstructure 32 2.11.1. Storey Drift 32 2.11.2. P-Δ effect 33 2.11.3. Overturning Moment 34 2.11.4. Torsional Irregularities 35 2.11.5. Stiffness Irregularity -Soft Storey 36 2.11.6. Sliding 37 v 2.12. 3 38 3.1. General 38 3.2. Configuration of Proposed Structure 38 3.3 Material Properties 38 3.4. Loading Considerations 39 3.4.1. Dead load 39 3.4.2. Live Load 39 3.4.3. Wind Load 39 3.4.4. Earthquake Load 40 Determination of Load Combinations 40 COMPARISON OF ANALYSIS RESULTS 42 4.1. General 42 4.2. Sizes of Structural Members 42 4.2.1. Sizes of Beams and Column 42 4.2.2. Thicknesses of Shear Wall and Slab 43 Stability Checking According to MNBC-2020 44 4.3.1. Checking for Storey Drift 44 4.3.2. Checking for P-Δ Effect 45 4.3.3. Checking for Overturning Moment 47 4.3.4. Checking for Torsional Irregularity 48 4.3.5. Checking for Soft Storey 50 4.3.6. Checking for Sliding 53 4.4. Time Period 54 4.5. Comparison of Results for Storey Drift 55 4.6 Comparison of Results for Storey Shear 58 4.7. Comparison of Results for Storey Displacement 60 4.8. Comparison of Results for Overturning Moment 63 4.9. Comparison of Storey Stiffness 66 410. Comparison of Structural Behaviour of Structural Member at 4.3. Setback 5 37 PREPARATION OF DESIGN DATA FOR PROPOSED BUILDING 3.5 4 Natural Time Period of the Building 69 DISCUSSIONS, CONCLUSION AND RECOMMENDATIONS 77 5.1. Discussions 77 5.2. Conclusion 78 vi 5.3. Recommendations 78 REFERENCES 80 APPENDICES 81 APPENDIX A 85 APPENDIX B 78 APPENDIX C 113 LIST OF PUBLICATIONS 116 vii LIST OF FIGURES Figure Page 1.1 Flow Chart for Implementation Programme 3 2.1 Weak Beam-Strong Column Behaviour 9 2.2. Reinforced Concrete Shear Wall 17 2.3. Shear Wall Frame 17 2.4. Moment Resisting Frame 18 2.5. Braced Frame 21 2.6. Eccentricities and Torsional Deformations 25 2.7. Storey Drift 26 2.8. Re-entrant Corner Irregularity 26 2.9. Diaphragm Discontinuity Irregularity 27 2.10. Diaphragm Discontinuity 27 2.11. Out-of-plane Offsets Irregularity 28 2.12. Nonparallel Systems Irregularity 28 2.13. Stiffness Irregularity – Soft Storey 29 2.14. Weight Irregularity 30 2.15. Vertical Geometric Irregularity 30 2.16. In-plane Discontinuity in Vertical Lateral-Force-Resisting Elements 31 2.17. Weak Storey 31 2.18. Checking for Torsional Irregularity 35 4.1. Comparison of Storey Drift in X-direction 56 4.2. Comparison of Storey Drift in Y-direction 57 4.3. Comparison of Storey Shear in X-direction 59 4.4. Comparison of Storey Shear in Y-direction 60 4.5. Comparison of Storey Displacement in X-direction 62 4.6. Comparison of Storey Displacement in Y-direction 63 viii 4.7. Comparison of Overturning Moment in X-direction 65 4.8. Comparison of Overturning Moment in Y-direction 66 4.9. Comparison of Storey Stiffness in X-direction 68 4.10. Comparison of Storey Stiffness in Y-direction 69 4.11. Shear Force Diagram of Elevation B and C at Bago Seismic Location 71 4.12. Bending Moment Diagram of Elevation B and C at Bago Seismic Location 72 Shear Force Diagram of Elevation B and C at Nay Pyi Taw Seismic Location 72 Bending Moment Diagram of Elevation B and C at Nay Pyi Taw Seismic Location 73 4.13. 4.14. 4.15. Shear Force Diagram of Elevation B and C Taunggyi Seismic Location 73 4.16. Bending Moment Diagram of Elevation B and C at Taunggyi Seismic Location 74 4.17. Shear Force Diagram of Elevation B and C at Yangon Seismic Location 74 4.18. Bending Moment Diagram of Elevation B and C at Yangon Seismic Location 75 C.1. 3D View of the Structure 113 C.2. Architectural Plan of Car Parking Floor (Ground Floor) 113 C.3. Architectural Plan of Shopping Area Floor (1st to 4th Floor) 114 C.4. Architectural Plan of Office Area Floor (5th to 9th Floor) 114 C.5. Architectural Plan of Residential Floor (10th to 14th Floor) 115 ix LIST OF TABLES Table Page 3.1. Seismic Parameters and Factors for Proposed Locations 40 4.1. Column Sizes 42 4.2. Beam Sizes 43 4.3. Checking for Storey Drift in X-direction 44 4.4. Checking for Storey Drift in Y-direction 45 4.5. Checking for P-Δ Effect in X-direction 45 4.6. Checking for P-Δ Effect in Y-direction 46 4.7. Checking for Overturning Moment in X-direction 47 4.8. Checking for Overturning Moment in X-direction 48 4.9. Checking for Torsional Irregularity in X-direction 49 4.10. Checking for Torsional Irregularity in Y-direction 49 4.11. Checking for Soft Storey in X-direction (Case I) 50 4.12. Checking for Soft Storey in Y-direction (Case I) 51 4.13. Checking for Soft Storey in X-direction (Case II) 51 4.14. Checking for Soft Storey in Y-direction (Case II) 52 4.15. Checking for Sliding in X-direction 53 4.16. Checking for Sliding in Y-direction 54 4.17. Time Period of the Structure 54 4.18. Analysis Results of Storey Drift in X-direction 55 4.19. Analysis Results of Storey Drift in Y-direction 55 4.20. Analysis Results of Storey Shear in X-direction 58 4.21. Analysis Results of Storey Shear in Y-direction 58 4.22. Analysis Results of Storey Displacement in X-direction 61 4.23. Analysis Results of Storey Displacement in Y-direction 61 4.24. Analysis Results of Overturning Moment in X-direction 63 4.25. Analysis Results of Overturning Moment in Y-direction 64 4.26. Comparison of Storey Stiffness in X-direction 67 x 4.27. Comparison of Storey Stiffness in Y-direction 67 4.28. Analysis Results for Beam Shear Forces at B96 and B11 70 4.29. Analysis Results for Beam Bending Moment at B96 and B11 70 A.1. 0.2s (Ss) and 1.0s (S1) Special Maximum Considered Earthquake Ground Motion Accelerations at 2% Probability in 50 Years with 5% Critical Damping, Site Class B 82 A.2. Basic Wind Speed (3 sec Gust Wind Speed in mph) 83 B.1. Checking for Storey Drift in X-direction for Nay Pyi Taw 85 B.2. Checking for Storey Drift in Y-direction for Nay Pyi Taw 85 B.3. Checking for Storey Drift in X-direction for Taunggyi 86 B.4. Checking for Storey Drift in Y-direction for Taunggyi 87 B.5. Checking for Storey Drift in X-direction for Yangon 87 B.6. 88 Checking for Storey Drift in Y-direction for Yangon B.7. Checking for P-Δ Effect in X-direction for Nay Pyi Taw 89 B.8. Checking for P-Δ Effect in Y-direction for Nay Pyi Taw 89 B.9. Checking for P-Δ Effect in X-direction for Taunggyi 90 B.10. Checking for P-Δ Effect in Y-direction for Taunggyi 90 B.11. Checking for P-Δ Effect in X-direction for Yangon 91 B.12. Checking for P-Δ Effect in Y-direction for Yangon 92 B.13. Checking for Overturning Moment in X-direction for Nay Pyi Taw 92 B.14. Checking for Overturning Moment in Y-direction for Nay Pyi Taw 93 B.15. Checking for Overturning Moment in X-direction for Taunggyi 94 B.16. Checking for Overturning Moment in Y-direction for Taunggyi 94 B.17. Checking for Overturning Moment in X-direction for Yangon 95 B.18. Checking for Overturning Moment in Y-direction for Yangon 96 B.19. Checking for Torsional Irregularity in X-direction for Nay Pyi Taw 96 B.20. Checking for Torsional Irregularity in Y-direction for Nay Pyi Taw 97 B.21. Checking for Torsional Irregularity in X-direction for Taunggyi 98 B.22. Checking for Torsional Irregularity in Y-direction for Taunggyi 98 B.23. Checking for Torsional Irregularity in X-direction for Yangon 99 B.24. Checking for Torsional Irregularity in Y-direction for Yangon 100 B.25. Checking for Soft Storey in X-direction for Nay Pyi Taw (Case I) 100 B.26. Checking for Soft Storey in Y-direction for Nay Pyi Taw (Case I) 101 B.27. Checking for Soft Storey in X-direction for Taunggyi (Case I) 101 xi B.28. Checking for Soft Storey in Y-direction for Taunggyi (Case I) 102 B.29. Checking for Soft Storey in X-direction for Yangon (Case I) 103 B.30. Checking for Soft Storey in Y-direction for Yangon (Case I) 103 B.31. Checking for Soft Storey in X-direction for Nay Pyi Taw (Case II) 104 B.32. Checking for Soft Storey in Y-direction for Nay Pyi Taw (Case II) 105 B.33. Checking for Soft Storey in X-direction for Taunggyi (Case II) 105 B.34. Checking for Soft Storey in Y-direction for Taunggyi (Case II) 106 B.35. Checking for Soft Storey in X-direction for Yangon (Case II) 106 B.36. Checking for Soft Storey in Y-direction for Yangon (Case II) 107 B.37. Checking for Sliding in X-direction for Nay Pyi Taw 108 B.38. Checking for Sliding in Y-direction for Nay Pyi Taw 108 B.39. Checking for Sliding in X-direction for Taunggyi 109 B.40. Checking for Sliding in Y-direction for Taunggyi 110 B.41. Checking for Sliding in X-direction for Yangon 110 B.42. Checking for Sliding in Y-direction for Yangon 111 xii LIST OF SYMBOLS Symbol Description Cd Deflection Amplification Factor Cs Seismic Response Coefficient Ct Building Period Coefficient DL Dead Load EQX Earthquake Load in X-Direction EQY Earthquake Load in Y-Direction fc ' Specified Compressive Strength of Concrete fy Specified Yield Strength of Reinforcement Fa Short-Period Site Coefficient Fi Portion of Seismic Base Shear V Induced at Level i hsx The Storey Height Below Level x hi, hx The Height from the Base to Level i and Level x hn The Height in ft Above the Base to The Highest Level of the Structure I The Importance Factor LL Live Load Mr Resisting Moment Mx, My Overturning Moment of the Structure in X-direction and Ydirection Px The Total Vertical Design Load R Response Modification Coefficient S1 The Spectral Response Acceleration Parameter at a Period of 1s Ss The Spectral Response Acceleration Parameter at Short Periods Sa The Design Spectral Response Acceleration SD1 The Design Spectral Response Acceleration Parameter at 1-s Periods xiii SDS The Design Spectral Response Acceleration Parameter at Short Periods Range SPECX Specified Response Spectrum Case Load in X-direction SPECY Specified Response Spectrum Case Load in Y-direction T The Fundamental Period of the Structure Ta Approximate Fundamental Period TL Long-Period Transition Period Vx Seismic Design Shear in Storey x W Effective Seismic Weight WX Wind Load in X-Direction WY Wind Load in Y-Direction x Approximate Period Parameter Δ Design Storey Drift Δall Allowable Storey Drift δx Deflection of Level x at the Centre of the Mass at and above Level x δxe Deflection of Level x at the Centre of the Mass at and above Level x Determined by an Elastic Analysis δmax Maximum Displacement at Level x δmin Minimum Displacement at Level x δavg The Average of the Displacements at the Extreme Points of the Structure at Level x θ The Stability Coefficient CHAPTER 1 INTRODUCTION 1.1. General Nowadays, different floors of structures are utilized for various purposes as the space and land available for the construction of buildings are insufficient. To fulfill the demand, high-rise buildings with irregularity are being widely constructed in this developing country, Myanmar, according to economic and social demand. These irregular buildings will be more popular in the future. The seismic response of the irregular building may be significantly different from that of regular building. Structures may possess combination of irregularities and consideration of irregularity may not result in accurate prediction of seismic response even for single irregularity. The choice of type, degree and location of irregularities in the design of structures is important as it helps in improving the utility, performance as well as aesthetics of structure. An earthquake is perceptible shaking of the earth surface that can be violent enough to destroy many properties and kill thousands of people. Earthquake is also considered as the most unpredictable and devastating of all other natural disasters. Earthquakes happen more frequently in Myanmar recently, the risk from them is worrisome. So, earthquake load plays in main role in the design of RC building, the seismic design for these irregular buildings has to be carefully considered to lessen the earthquake risks. Recent earthquake occurrences in world demonstrate that buildings with irregularity are most likely to suffer from earthquake damages. Failures arise due to irregularities in mass, stiffness and geometry of structure. So, the behaviour of a high-rises RC building during strong earthquake motion also depends on structural configuration. In order it is essential to identify the seismic response of the structure even in low seismic locations to reduce the seismic damages in buildings. So, the analysis and design of a building with irregularity in seismic zone turn into a matter of concern. When a building is subjected to dynamic loads, inertia forces are developed and 2 gets concentrated at the center of mass of the structure. The center of mass of irregular structures do not coincide with the center of stiffness as the regular structures do. So, the eccentricity develops in the structures. Eccentricity occurred due to irregularity may induce torsion in the structure which may result in damage of structure. Design codes prohibit construction or recommend special seismic design of irregular buildings depending on the level of irregularity and site hazard. When the irregular buildings are constructed in high seismic locations, the analysis and design become more complicated. There are many methods to analyze the Such analysis and design are being performed using computer-aided analysis and design software such as ETABS, SAP 2000 and Tekla, etc., in order to be analyzed more easier for high-rise complicated design in accordance with design codes. 1.2. Objectives of the Study The main objectives of the study are as follows: 1. To analyze the vertical geometric irregular high-rise RC building as per MNBC 2020. 2. To compare the structural behaviours such as storey drift, base shear and storey displacement, storey stiffness and the forces and bending moment of structural members at setback. 3. To investigate the differences between the responses of vertical geometric irregular RC building in accordance with different seismic locations. 1.3. Scopes of the Study The scopes of this study are the following: 1. In this study, the proposed buildings are 15-storied reinforced concrete buildings with vertical geometric irregularities. 2. The horizontal dimension of the proposed buildings in 5th Storey is more than 130% of that in the 6th Storey. 3. They are situated in Bago, Nay Pyi Taw, Taunggyi and Yangon. 4. Only superstructures of proposed buildings are considered and dynamic analysis (response spectrum analysis) is used for checking the stability of the structures. 5. The structural behaviours of the buildings at different locations are compared when the models are of the same member sizes for all locations. 3 6. The suitable optimum sizes for Nay Pyi Taw, Taunggyi and Yangon are investigated. 7. Modelling and structural analysis of buildings are carried out with ETABS 2016 software. 8. Loading considerations are based on ASCE 7 - 05 and MNBC 2020 and building code requirements for structural elements are according to ACI 318-08. 1.4. Implementation Programme The following flow chart is the implementation programme of the study. Literature Review Modeling 15-Storeyed Reinforced Building using ETABS 2016 Software Bago Nay Pyi Taw Taunggyi Yangon Dynamic Analysis (Response Spectrum Analysis) Studying Behaviours of Structures Checking for Stability of the Structure Comparing Structural Behaviours - Storey Drift - P-delta Effect - Overturning Moment - Torsional Irregularity - Soft Storey - Sliding - Storey Drift - Storey Shear - Storey Displacement - Overturning Moment - Behaviours of Structural Member at Setback Discussion, Conclusion and Recommendation Figure 1.1. Flow Chart for Implementation Programme 4 1.5. Outlines of the Study This study includes five chapters. The first chapter presents general and overview of the study. The second chapter describes the background theory of the irregular buildings. The third chapter composes the preparation of design data which are loading condition, selection of design codes and determination of load combinations for proposed buildings using ETABS software. The fourth chapter describes analysis results, the effects of the structural behaviours and their comparison. Finally, the discussions, conclusions and recommendations based on this study are presented in the last chapter. CHAPTER 2 BACKGROUND THEORY 2.1. General In this chapter, brief of literature review of previous study on related topic is described and provided theory and necessary background for this study are described. Firstly, the responses of high-rise buildings during seismic an earthquake are described. Next, considered load in seismic analysis, analysis method and the background theory of irregular structures expressed. Finally, stability consideration of the superstructure is described. 2.2. Introduction In general, RC structures designed for gravity load may not be able to safely sustain the effect of horizontal earthquake shaking. Therefore, it is necessary to ensure adequacy of the RC structures against horizontal earthquake shaking. And also, as the population is growing day by day, the high-rise RC buildings are very much needed to meet the requirements of the population growth. Hence, these high-rise RC structures must adequately resist against earthquake. For this reason, the analysis and design of structures are becoming important issues in preliminary stage of high-rise RC construction. The performance of RC building affected by the earthquake shaking depends on its configuration. It has been found that regular structures perform better during earthquakes. Nowadays, irregular high-rise buildings are being constructed according to the population growth and due to the purpose of the structures. Non-uniform load distribution is resulted in various members of an irregular structure. A discontinuity in the load transmission path results in the failure of the structure. The behaviour of a high-rise RC building during an earthquake is a vibration problem. The seismic motions of the ground do not damage a building by impact as does a wrecker’s ball, or by externally applied pressure such as wind, but rather by internally generated inertial forces caused by vibration of the building mass. The 6 seismic motions of the ground cause the structure to vibrate and the amplitude and distribution of dynamic deformations and their duration are of concern to the engineer. The chief objective of earthquake design is that the building should not be a hazard to life and limb in the event of a strong shaking. During moderate ground shaking that has a significant probability of occurrence during the life of the structure, the vibrations may be in the elastic range with no damaging amplitude, but during strong ground shaking, members may undergo plastic strain and there may be some cracking. Moreover, in earthquake-resistant design, it is not sufficient to make a member “strong”. It must also have a reserve of ductility. [9] 2.3. Response of High-rise RC Building During Earthquake In general, high-rise RC buildings respond to seismic motion somewhat differently than low-rise buildings. As experienced by structures, earthquakes consist of random horizontal and vertical movements of the earth’s surface. As the ground moves, inertia tends to keep structures in place, resulting in the imposition of displacements and forces. The distortion wave travels along the height of the structure. The continued shaking of the base causes the building to undergo a complex series of oscillations. The purpose of seismic design is to proportion and detail the structures so that they can withstand the displacements and forces induced by the ground motion. Experience has shown that the horizontal components of ground motion are the most destructive. Although peak ground acceleration is an important design parameter, the frequency characteristics and duration of an earthquake are also important; the closer the frequency of the earthquake motion is to the natural frequency of a structure and the longer the duration of the earthquake, the greater the potential for damage. Earthquake response depends strongly on the geometric properties of a structure, especially height. High-rise buildings respond more strongly to long-period (lowfrequency) ground motion, while low-rise buildings respond more strongly to shortperiod (high-frequency) ground motion. The seismic response of short, stiff buildings is dominated by the first or fundamental mode of response; most of the building mass vibrates in that mode. The higher a structure, the more susceptible it is to the effects of higher mode of vibration, which are generally additive to the effects of the lower modes and tend to have greatest influence on the upper storeys. Under any circumstances, the longer the duration of an 7 earthquake, the greater the potential for damage. [10] The magnitude of the horizontal inertia forces induced by earthquakes depends on the building mass, ground acceleration, and the nature of the structure. For a hypothetical rigid building founded on infinitely stiff foundation, the inertia force is given by the product of a given ground acceleration and the building mass. Since all structures deform, the deformation absorbs some energy; the force tends to less than the product of mass and ground acceleration. A high-rise RC structure tends to be more flexible than a low-rise building, and would experience accelerations much less than a low-rise building. And the magnitude of lateral force in a high-rise RC structure is influenced to a great extent by the type of response of the structure itself. Response in Elevation: The building as a vertical cantilever – when subjected to lateral forces only, a building will act as a vertical cantilever. The resulting total horizontal force and the overturning moment will be transmitted at the level of the foundations. Once the lateral forces, such as may act at each level of the building, are known, the storey shear forces, as well as the magnitude of overturning moments at any level can readily be derived from usual equilibrium relationship. [7] Response in Plan: Centers of mass and rigidity – The position of the resultant force in the horizontal plane will depend on the plan distribution of vertical elements and it must also be considered. As a consequence, two important concepts must be defined. These will enable the effects of building configurations on the response of structural systems to lateral forces to be better appreciated. As for center of mass, accelerationinduced inertia forces will be generated at each floor level during an earthquake, where the mass of an entire Storey may be assumed to be concentrated. Hence, the location of force at a particular level will be determined by the center of the accelerated mass at that level. In regular buildings, the positions of the centers of floor masses will differ very little from level to level. However, irregular mass distribution over the height of a building may result in variations in centers of masses which will need to be evaluated. If, as result of lateral forces, one floor of the building translates horizontally as a rigid body relative to the floor below, a constant interstorey displacement will be imposed on all frames and walls in that Storey. Therefore, the induced forces in these elastic frames and walls will be proportional to the respective stiffnesses. The resultant total force induced by the translational displacements will pass through the center of rigidity. This point, defined as the center of rigidity or center of stiffness, locates the position of 8 a storey shear force, which will cause only relative floor translations. The position of the center of rigidity may be different in each Storey. It is relevant to storey shear forces applied in any direction a horizontal plane. [7] Displacements due to storey twist can result in total element interstorey displacements that may difficult to accommodate. For this reason, the designer should attempt to minimize the magnitude of storey torsion. To achieve this, the distance between the center of rigidity and the center of mass should be minimized. [7] 2.4. Seismology of Myanmar Myanmar, located on the eastern margin of the ongoing Indo-Eurasian collision system, has experienced a complex tectonic history. The region is characterized by the southward extrusion of the Shan-Thai plateau to the east and the highly oblique subduction of the India plate to the west. A large portion of the plate conversion is partitioned onto the nearly N-S-oriented Sagaing Fault (SF) running through the country. Due to the active tectonics in the region, Myanmar is threatened by a high level of seismic hazard. In addition, the economic (Yangon) and political (Naypyidaw) centres of the country are located along a seismic gap of the SF, which could rupture in a damaging earthquake in the near future. However, the earthquakes and velocity structure in the region are poorly known due to the lack of regional seismic observations. 2.5. Member Considerations Members designed for seismic loading must perform in a ductile fashion and dissipate energy in a manner that does not compromise the strength of the structure. Both the overall design and the structural details must be considered to meet this goal. The principal method of ensuring ductility in members subject to shear and bending is to provide confinement for the concrete. This is accomplished through the use of closed hoops or spiral reinforcement, which enclose the core of beams and columns. [10] For a frame undergoing lateral displacement, the flexural capacity of the members at a joint should be such that the columns are stronger than the beams. In this way, hinges will form in the beams rather than the columns, minimizing the portion of the structure affected by nonlinear behaviour and maintaining the overall vertical load capacity. For this reason, the “weak beam-strong column” approach is used to design reinforced concrete frames subject to seismic loading. The behaviour of weak beamstrong column is illustrated in Figure. 2.1. [6] 9 The member must be checked for adequacy under the shear in addition to shear resulting from dead and live gravity loads. Transverse reinforcement is added, as required. For members with inadequate shear capacity, the response will be dominated by the formation of diagonal cracks, rather than ductile hinges, resulting in a substantial reduction in the energy dissipation capacity of the member. [6] If short members are used in a frame, the members may be unintentionally strong in flexure compared to their shear capacity. An example would be columns in a structure with deep spandrel beams or with “nonstructural” walls with openings that expose a portion of the columns to the full lateral load. As a result, the exposed region, called a captive column, responds by undergoing a shear failure. [6] The lateral displacement of a frame places beam-column joints under high shear stresses because of the change from positive to negative bending in the flexural member from one side of the joint to the other. The joint must be able to withstand the high shear stresses and allow for a change in bar stress from tension to compression between the faces of the joint. Such a transfer of shear and bond is often made difficult by congestion of reinforcement through the joint. Thus, designers must ensure that joints not only have adequate strength but are also constructable. Two-way systems without beams are especially vulnerable because of low ductility at the slab-column intersection. [6] Reinforced Concrete Column Reinforced Concrete Beam Steel Frame Floor Figure. 2.1. Weak Beam-Strong Column Behaviour 10 2.6. Loads and Forces Loads results from the effect of gravity such as dead loads, live loads and wind load, earthquakes or restraints against deformations are considered in the seismic analysis. 2.6.1. Dead Loads Dead loads result from the weight of the structure and all other permanently attached materials. Average or typical values for superimposed materials and loads are readily obtained from manuals. The characteristic feature of dead loads is that they are permeant. Codes prescribe certain variable loads, such as movable partition walls, to be considered as permanent. For the sake of safety, dead loads are customarily overestimated. This fact should be considered in seismic design, whenever gravity load effects enhance strength when combined with effects of seismic forces, such as may occur when estimating moment capacity of columns. [7] 2.6.2. Live Loads Live loads result from expected usage. They may be movable and their intensity may vary. Maximum intensities specified by codes are based on probabilistic estimates. In most cases, they are simulated by uniformly distributed loads placed over the entire area of the floor. However, for certain areas with special use, point loads may also be specified. [7] The probability of an area being subjected to the maximum specified intensity of live load diminishes as the size of the loaded floor area increases. Floors used for offices are typical examples. While an element of floor slab must be designed to sustain the full intensity of the live load, a beam or a column, receiving live load from a considerable tributary floor area, may be assumed to receive live loads with smaller intensity. [7] Dead and live loads need also be considered when an estimate is made for the equivalent mass of a building. For the purpose of estimating seismic accelerationinduced horizontal inertia forces, it is sufficient to assume that the mass of the floor system, including finishes, partitions, beams, and columns one-half storey above and below a floor, and with a fraction of the live load acting over the entire floor of a storey, is concentrated at the floor level of the structural model (i.e., at the center of the mass). In assessing inertia forces, some codes ignore some types of live loads, while others 11 specify that a certain fraction, typically one-third of the code-specified intensity, be converted into an equivalent mass. [7] 2.6.3. Wind Load Wind load is the load placed by the wind speed and its air density onto a building. Every building or structure and every portion shall be designed and constructed to resist wind effects determined in accordance with the requirements of the region. The response of structures to wind depends on the characteristics of the wind. Wind impact is horizontal loading in the building. For high rise buildings, wind may contribute to deflection. Wind effect on structure is usually consider for the building. [2] Wind exerts dynamic and static effect on a building and the major types of loads due to wind can be classified into shear, moment and deflection. Static wind effect primarily causes elastic bending and twisting of the structure. For tall, long span and slender structures, a dynamic analysis of the structure is essential. Wind gust cause fluctuating forces on the structure which induce large dynamic motions, including oscillations. [2] Besides depending on wind speed and building height, wind forces vary with the shape of the building. The wind exerts a pressure on the windward surface of a rectangular building because the movement of the air particles is stopped by this face. The air particles, forced from their original direction, go around the building in order to continue their flow and get together again behind the building. Wind forces occur on the exterior envelope of the building and are a function of its height, local ground surface roughness (hills, trees, and other buildings). Their magnitude is directly proportional to square of the wind velocity. The weight of the building, unlike earthquake design, no effect on win forces, but is helpful in resisting uplift. Unless the structure has large openings, all wind forces are applied to the building exterior. This is in contrast to earthquake forces where both exterior and interior elements are loaded proportionally to their weight. Wind pressures act inward only on the windward face and outward on the most sides and roof surfaces. 2.6.4. Earthquake Forces When earthquake occur, a building has been undergone dynamic motion. This is because the building is subjected to inertia forces that act in opposite direction to the acceleration of earthquake excitations. These inertia forces are called seismic load and 12 are usually deal with by assuming forces external to the building. Seismic load happens at contact surfaces of a structure either with the ground, or with adjacent structures or with gravity waves from tsunami. Every structure and portions which include non-structural elements shall be designed and constructed to resist the effects of seismic ground motions. The seismic motion that reaches a structure on the surface of the earth is influenced by the local soil condition. Tall buildings tend to experience greater structural damage when they located on soils having a long period of motion because of the resonance effect that develops between the structure and the underlying soils. The earthquake load estimation includes two steps: determination of design base shear and distribution of total base shear over the height of the structure. 2.6.4.1. Seismic Base Shear The seismic base shear, V, in a given direction shall be determined in accordance with the following equation. [5] V=CsW Equation 2.1 where, Cs = the seismic response coefficient W = the effective seismic weight 2.6.4.2. Calculation of Seismic Response Coefficient The seismic response coefficient, Cs, shall be determined in accordance with the following equation. [5] Cs = SDS R (I) Equation 2.2 The value of Cs computed in accordance with Equation 2.2 need not exceed the following: Cs = SD1 R T(I) for T≤ TL Equation 2.3 Cs = SD1 TL R T2 ( I ) for T > TL Equation 2.4 Cs shall not be less than 13 Cs = 0.044 SDS I ≥ 0.01 Equation 2.5 In addition, for structures located where S1 is equal to or greater than 0.6g, Cs shall not be less than Cs = 0.5S1 R (I) Equation 2.6 Where, SDS = the design spectral response acceleration parameter in the short period range R = the response modification factor I = the occupancy importance factor determined SD1 = the design spectral response acceleration parameter at a period of 1.0 s T = the fundamental period of the structure TL = long-period transition period S1 = the mapped maximum considered earthquake spectral response acceleration parameter 2.7. Structural analysis Structural analysis is the prediction of the response of structures to specified arbitrary external loads. During the preliminary structural design stage, a structure’s potential external load is estimated, and the size of the structure’s interconnected members are determined based on the estimated loads. Structural analysis establishes the relationship between a structural member’s expected external load and the structure’s corresponding developed internal stresses and displacements that occur within the member when in service. This is necessary to ensure that the structural members satisfy the safety and the serviceability requirements of the local building code and specifications of the area where the structure is located. There are two ways to approach for seismic analysis and design of structure. They are static analysis procedure and dynamic analysis procedure. 2.7.1. Static Analysis A static structural analysis determines the displacements, stresses, strains, and forces in structures or components caused by loads that do not induce significant inertia and damping effects. Steady loading and response conditions are assumed; that is, the 14 loads and the structure’s response are assumed to vary slowly with respect to time. The types of loading that can be applied in a static analysis are more static loading conditions which does not change over the time and location. According to UBC-97 static lateral force procedure may generally be used for the following structures: 1. Regular structures under 240 feet (73 152 mm) in height. 2. Irregular structures not more than five stories or 65 feet (19 812 mm) in height. [2] 2.7.2. Dynamic Analysis Determining the behaviour of a structure during an earthquake is basically a vibration problem. The seismic motions of the ground cause the structure to vibrate and the amplitude of vibration of this dynamic deformation and tis duration are of concern to the engineer. Using dynamic analysis, calculations can be made of the earthquakeinduced vibrations of the structures, and these will indicate the general nature and amplitude of the deformation that can be expected during the earthquake. The actual earthquake design criteria must be based on a number of considerations, such as the probability of occurrence of strong ground shaking, the characteristics of the ground motion, the nature of the structural deformation, the behaviour of the building materials when subjected to oscillatory strains, the nature of the building damage that may be sustained, and the cost of repairing the damages compared to the cost of providing additional earthquake resistance. According to UBC-97, the dynamic lateral-force procedure shall generally be used for all other structures, including the following: 1. Structures 240 feet (73 152 mm) or more in height. 2. Structures having a stiffness, weight or geometric vertical irregularity. Generally, there are two choices available for applying the dynamic earthquake loads, namely, the time history or the response spectrum method. 2.7.2.1. Time history analysis Time history analysis is an analysis of the dynamic response of a structure at each increment of time when the base is subjected to a specific ground motion time history. The time history method requires prescription of a specific ground motion 15 record which requires prediction of the future critical ground motion that can occur at a given site. The difficulties associated with prescribing appropriate earthquake motions are numerous because of the highly indeterminant nature of estimating future seismic ground motions that may occur at a site during the useful life of a structure. Time history analysis shall be performed with pairs of appropriate horizontal ground-motion time history components that shall be selected and scaled from not less than three recorded events. Appropriate time histories shall have magnitude, fault distances and source mechanisms that are consistent with those that control the designbasis earthquake (or maximum capable earthquake). Where three appropriate recorded ground-motion time history pairs are not available, appropriate simulated ground motion time history pairs may be used to make up the total number required. For each pair of horizontal ground motion components, the square root of the sum of the squares (SRSS) of the 5 percent-damped site- specific spectrum of the scaled horizontal components shall be constructed. The motions shall be scaled such that the average value of the SRSS spectra does not fall below 1.4 times the 5 percent-damped spectrum of the design-basis earthquake for periods 0.2T second to 1.5T seconds. Each pair of time histories shall be applied simultaneously to the model considering torsional effects. The parameter of interest shall be calculated for each time history analysis. If three time-history analyses are performed, then the maximum response of the parameter of interest of shall be used for design. If seven or more time-history analyses are performed, then the average value of the response parameter of interest may be used for design. 2.7.2.2. Response spectrum analysis Response spectrum analysis is an elastic dynamic analysis of a structure utilizing the peak dynamic response of all modes having a significant contribution to total structural response. Peak modal responses are calculated using the ordinates of the appropriate response spectrum curve which correspond to the modal periods. Maximum modal contributions are combined in a statistical manner to obtain an approximate total structural response. In order to perform the seismic analysis and design of a structure to be built at a particular location, the actual time history record is required. However, it is not possible to have such records at each and every location. Further, the seismic analysis 16 of structures cannot be carried out simply based on the peak value of the ground acceleration as the response of the structure depend upon the frequency content of ground motion and its own dynamic properties. To overcome the above difficulties, earthquake response spectrum is the most popular tool in the seismic analysis of structures. There are computational advantages in using the response spectrum method of seismic analysis for prediction of displacements and member forces in structural systems. The method involves the calculation of only the maximum values of the displacements and member forces in each mode of vibration using smooth design spectra that are the average of several earthquake motions. The method, based on response spectrum, is generally cost effective and therefore is the most widely used approach for representing dynamic earthquake loading. 2.8. Types of Lateral Load Resisting Systems Lateral load resisting systems are the structural elements which resist seismic, wind and gravity loads. There are many types of lateral load resisting systems. However, most of the systems can be broken down to three fundamental ones which all other systems are a combination of. They are 1. shear walls 2. moment resisting frames and 3. braced frames 2.8.1. Shear Walls Shear walls are often defined as vertical elements of the horizontal load resisting system. Walls of steel or timber frames with a board fastened to it are included in the definition. Masonry shear walls are also used, with solid walls and grouted cavity masonry with reinforcements encased. However, considering high-rise building shear walls are more associated with reinforced concrete walls. The reinforced concrete shear wall used in high rise buildings and shear wall frame are as shown in Figure. 2.2 and Figure 2.3. Shear walls generally start at foundation and are continuous throughout the building height. The walls provide large strength and stiffness to buildings in the direction of their orientation, mostly due to its large cross-sectional area that provide great moment of inertia, which significantly reduces lateral sway of the building. The reason to make big elements of reinforced concrete instead of other materials, e.g., steel 17 which would give even more stiffness, is its much cheaper cost. The location of the shear walls is different depending on the buildings intent to be either an office or a residential building. The need for shear walls in residential buildings occurs mostly between apartments because of higher demands for sound and fire resistance resulting in a web of smaller bearing walls. In office buildings, there is a huge requirement for flexible floor plans and for a large number of elevators and stairwells which makes it more sufficient to concentrate shear walls around them. A box-type structure of shear walls rigidly connected has greater stiffness by acting as a tube. [8] Figure. 2.2. Reinforced Concrete Shear Wall Shear Wall Figure. 2.3. Shear Wall Frame 18 To stabilize a building against lateral loads from different directions, a simple rule for the amount and placement of shear walls is that there should be at least three of them and they may not intersect at the same point of be only parallel to each other. For building up to 20 stories, the use of structural walls is often a matter of choice. For buildings over 30 stories, structural walls may become imperative from the point of view of economy and control of lateral deflection. [8] 2.8.2. Moment Resisting Frame Moment resisting frame, as shown in Figure 2.4., also called moment frames or rigid frame is made by rigid connections between horizontal and vertical members. Steel, reinforced concrete and steel-concrete composite rigid frames are used. In earlier high-rise buildings, while concrete was under development, steel frames were predominated. The combination of steel and concrete has evolved in recent times, which offer the ability to quickly build the framework of steel and then incasing concrete into the frame to increase its stiffness and weight. The higher weight and stiffness improve the damping and the axial strength. [8] Figure. 2.4. Moment Resisting Frame The lateral deformation of rigid frame depends mostly on shear sway but also on column shortening. Its resisting of lateral loads includes primarily by the flexural stiffness and strength of members and joints. Number of stories, Storey height and 19 column spacing has proportional influence on the frame’s strength and stiffness. Larger bending moment appears in the lower levels with its maximum in the connections. As building stories increase, so does the bending moment both in beams and columns. Columns usually get bigger from top to bottom with respect to increasing gravity load. They can therefore withstand the increased moment while the beams are subjected to the same gravitational loads but needs to be resized to manage the increased moment. Why the bending moment increases in columns with increasing number of stories is easy to understand while moment increasing in beams is a little bit harder. By applying only one wind-load on the top of the building, it is simpler to understand the principle of the developed force and the transmission through the building’s elements. As the force is applied at a distance from the ground, there will be a moment that by the equation of equilibrium results as vertical reaction forces in the supports, as tension and compression. There will also be horizontal reaction forces that prevent the lateral movement of the building. [8] Vertical and horizontal reaction forces give axial and shear loads at respective column at the supports. Without any beams in between these forces would transmit to the top unchanged. In the nodes the axial and shear forces would shift to shear and axial forces in the beam. As shear forces at the beam-ends act in different directions as the rotation of the beam would appear, there will be a moment to prevent it. The moment will be the highest at the connections and has a contra flexure point in the middle of the beam. The floor-beams at each Storey will act as the beam on the top. The axial forces in columns will be reduced proportionally between the stories caused of shorter lever arm. As the reducing is the same between the stories, all beams will be exposed for the same shear forces and therefore develop the same moment distribution and size. By adding one wind load at the time on each floor, from the top down, the moment in the beam below the applied floor will increase progressively. When the number of stories exceeds of about 30, huge dimensions of frame beams and complex connections are required that usage of a moment resisting frame gets uneconomical. The prime advantage of this system is the flexibility regarding windows and doors which is very good. That is one of the reasons why the moment frame is not 20 abandoned, instead quite the opposite, often used combined with other systems in highrise buildings. [8] 2.8.3. Braced Frame Bracing is another way to take care of horizontal loads. The simplest method is to place a diagonal brace, nodes are designed as leads. The transfer of horizontal loads down to one of the supports takes place in the brace’s direction in the form of either axial tension or compression depending on the direction of the horizontal load. This means that the axial stiffness of the frame members is what is resisting lateral loads. When subjected to a horizontal load, in an X-brace, one of the diagonals will be subjected to compression while the other is in tension. The braced frame is shown in Figure. 2.5. [8] There are many different types of bracing. While the most common and one of the most effective is the X-bracing, this takes a lot of spacing in the structure which makes little room left for openings. V, K, diagonal and knee bracing are other types that are often used. These provide better room for openings but are less effective against horizontal loads. There are also eccentrically braced systems that provide different shapes and openings. They have good ductility for resisting seismic forces but provide less stiffness than the concentric braced frame. [8] Braced frames or vertical trusses are often used in the core of high-rise buildings where it can be enclosed to form cells that are effective in resisting torsional forces. When subjected to a lateral load, the truss shows a cantilever parabolic sway. In itself the braced frame is not economical if the building size is above 20 to 30 floors but combined with another system, such as the moment frame, it can become more effective. While using a completely braced frame system in a high-rise building the stability is very good. This system has a few major drawbacks however. The weight of the building when completely braced becomes massive, with a lot of different pieces to fit together. Another drawback is the limitations in terms of space for windows and doors, the bracing means the openings have to fit in accordingly which also means that the ability to form an architectural expression would be less. [8] Other type of ways using the bracing can be to just have one part of the building with a vertical truss and the outer connections as leads. This provides the same sway as before, but it will deflect more and earlier. [8] 21 Figure. 2.5. Braced Frame 2.9. Seismic Force-Resisting Systems According to MNBC 2020, there are eight types of seismic force resisting systems: 1. Bearing wall systems 2. Building frame systems 3. Moment resisting frame systems 4. Dual systems with special moment frames capable of resisting at least 25% of prescribed seismic forces 5. Dual systems with intermediate moment frames capable of resisting at least 25% of prescribed seismic forces 6. Shear wall - frame interactive system with ordinary reinforced concrete moment frames and ordinary reinforced concrete shear walls 7. Cantilevered column systems detailed to conform to the requirements 8. Steel systems not specifically detailed for seismic resistance, excluding cantilever column systems. [5] 2.9.1. Bearing Wall Systems The bearing wall system is a structural system without an essential complete space frame that provides supports for the gravity loads. Bearing walls provide support 22 for all or most of the gravity loads. Resistance to lateral force is provided by the same bearing walls acting as shear walls. Ordinary reinforced concrete shear walls are permitted to be in structures assigned SDC B and C. For structures assigned to SDC C, ordinary or special reinforced concrete shear walls are to be utilized. Special reinforced concrete shear walls are walls conforming to the requirements ACI for special reinforced concrete structural walls. Special reinforced concrete structural walls are required for structures with bearing wall systems assigned to SDC D, E, or F. In such cases, the height of the building is limited to 160 ft for SDC D and E, and 100 ft for SDC F. [10] 2.9.2. Building Frame Systems A building frame system is a structural system with an essentially complete space frame that supports the gravity loads. Resistance to lateral force is provided by shear walls. No interaction between the shear walls and frames is considered in the lateral load analysis; all of the lateral forces are allocated to the walls. [10] For structures assigned to SDC B, the following types of concrete shear walls may be utilized without any limitations: ordinary plain, detailed plain and ordinary reinforced. Ordinary reinforced shear walls are allowed to be used in SDC C. [10Nyi] Special reinforced concrete shear walls are required for structures with building frame systems assigned to SDC B, C, D, E and F. In such cases, the height of the building is limited to 160 ft for SDC D and E and 100 ft for SDC F. [10] Although the walls are designed to carry all of the seismic forces, the beamcolumn frames must be designed to resist the effect caused by the lateral deflections, since they are connected to the walls at every level. Members not designated to be part of the seismic-force-resisting system must be capable of maintaining support of the gravity loads when subjected to the expected deformations caused by the seismic forces. 2.9.3. Moment Resisting Frame Systems A moment resisting frame system is a structural system with an essentially complete space frame providing support for gravity loads. Lateral forces are resisted primarily by flexural action of the frame members. The entire space frame or selected portion of the space frame may be designated as the seismic-force-resisting system; the members of the seismic-force-resisting system must be designed and detailed 23 accordingly, based on the SDC. [10] For structures assigned to SDC B, an ordinary reinforced concrete moment resisting frame is permitted. No special detailing of the frame members in accordance with intermediate moment frames or special moment frames are to be utilized for structures assigned to SDC B. members of the seismic-force-resisting system of intermediate moment resisting frames are to be detailed in accordance with ACI code dealing with requirements for intermediate moment frames. This is for structures assigned to SDC C. [10] Special moment resisting frames are required for structures assigned to SDC D, E and F. The special design and detailing requirements in ACI code must be satisfied for members of the special seismic-force-resisting system. [10] 2.9.4. Dual Systems A dual system is a structural system with the following essential features: 1. An essentially complete space frame provides support for gravity loads. 2. Resistance to lateral forces is provided by moment-resisting-frames capable of resisting at least 25 percent of the design base shear and the rest by shear walls or braced frames. 3. The two subsystems (moment-resisting frames and shear walls) are designed to resist the design base shear in proportion to their relative rigidities. The ASCE 7-05 separately recognizes dual systems in which the dual system is with special moment frames and dual systems in which the dual system is with intermediate moment frames. [10] For buildings assigned to SDC D, E, or F, a dual system with special moment frames and special reinforced concrete shear walls can be utilized without any height limitations. A dual system with an intermediate moment frames and special reinforced concrete shear walls may also be used; however, in SDC D, a building is then limited in height to 160 ft and in SDC E or F, the height limit is 100 ft. [10] For buildings assigned to SDC C, dual system with special or intermediate moment frames with special or ordinary reinforced concrete shear walls can be used without any limitations. Ordinary reinforced concrete shear walls are not permitted in dual system either with special or intermediate moment frame. [10] 24 2.9.5. Shear Wall-Frame Interactive with Ordinary Reinforced Concrete Moment Frames and Ordinary Reinforced Concrete Shear Walls In areas of low seismicity, utilizing a shear wall-frame interactive system is more logical. In this system, the shear walls and frames resist the lateral forces in proportion to their rigidities, considering interaction between the two sub systems at all levels. It is important to note that a shear wall frame interactive system is only allowed in structures assigned to SDC B. [5] 2.10. Irregularities in Structures The configuration of a structure also has a major effect on its response to an earthquake. Structures with a discontinuity in stiffness or geometry can be subjected to undesirably high displacements or forces. There are various types of irregularities in the buildings depending upon their location and scope, but mainly, they are divided into two groups – plan (horizontal) structural irregularities and vertical structural irregularities. Location and size of structural elements have significant effect on torsional coupling which results in damage of structures. Irregular structures have certain physical discontinuities either in plan or in elevation or both which affect the performance of the structure subjected to lateral loads. Irregularities in the distribution of mass, stiffness and geometry along the height of any building are grouped as vertical irregularities. Horizontal irregularities can be attributed to the presence of discontinuities in plan. Different structural irregularities affect the seismic response of structures in different ways. For example, the discontinuance of shear wall, infill walls or even cladding at a particular storey level will have the result of concentrating the displacement in the open or “soft” storey. The high displacement will, in turn, require a large amount of ductility if the structure is not to fail. 2.10.1. Plan (Horizontal) Structural Irregularities According to MNBC 2020, there are five types of plan structural irregularities: 1. (a) Torsional irregularity (b) Extreme Torsional irregularity 2. Re-entrant Corner 3. Diaphragm Discontinuity 4. Out-of-Plane Offsets 5. Nonparallel System 25 2.10.1.1. Torsional irregularity Ideally, a building subjected to earthquakes should be symmetrical or, at least, the distance between the centre of mass (the point through which the seismic forces act on a given floor) and the centre of resistance should be minimized. If there is an eccentricity, the building will undergo torsional deformations. The column at A in Figure. 2.6. (a) will then experience larger shears than the column B. The location of the centre of resistance is affected by the presence of both structural and nonstructural elements. The computed relative deflection of the top and the bottom of a storey is referred to as the storey drift, δmax. A category 1a torsional irregularity exists when the maximum storey drift computed including accidental torsion, at one end of a storey transverse to an axis, is more than 1.2 times the average of the storey drifts at the two ends of the structure in the same storey as shown in Equation 2.7. This definition applies only to buildings with rigid or semirigid diaphragms. The positions of storey drift are shown in Figure 2.7. [10] Δ2 > 1.2 ( Δ1 +Δ2 ) (Δ1 , Δ2 from Figure 2.7) 2 Equation 2.7 Center of mass Center of Resistance Eccentricity (a) Eccentricity of Earthquake Force (b) (c) (d) Figure 2.6. Eccentricities and Torsional Deformations A category 1b torsional irregularity exists when the ratio of maximum storey drift, computed including accidental torsion, to average of the elastic computed drifts 26 at the two ends exceeds 1.4 (extreme torsional irregularity) as shown in Equation 2.8. Irregular buildings should have significant torsional resistances and stiffnesses. Because the individual walls in Figure. 2.6. (b) are farther from the centre of resistance than those in Figure. 2.6. (c), they provide more torsional resistance. The plan in Figure. 2.6. (d) is particularly unsuitable. It has a large eccentricity and very little torsional resistance. [10] Δ1 +Δ2 Δ2 > 1.4 ( ) (Δ1 , Δ2 from Figure 2.7) 2 Δ2 Equation 2.8 Δ1 Figure 2.7. Storey Drift 2.10.1.2. Re-entrant corner irregularity If the plan has re-entrant corners and the floor system projects beyond the reentrant corner by more than 15 percent of the plan dimension of the building in the same direction, the building is said to have a re-entrant corner irregularity. For the building in Figure. 2.8, one solution is to separate the two wings by a joint that is wide enough so that the wings can vibrate separately without banging together. If this is not practical, the region joining the two parts must be strengthened to resist the tendency to pull apart. [10] a b Re-entrant d c Figure 2.8. Re-entrant Corner Irregularity Projection b > 0.15 a and Projection d > 0.15 c 27 2.10.1.3. Diaphragm discontinuity irregularity Figure. 2.9 shows a plan of a floor diaphragm transmitting seismic forces to shear walls at each end of a building. The diaphragm acts as a wide flat beam that develops tension and compression on its edges. Abrupt discontinuities or changes in the diaphragms, such as a notch in a flange, may lead to damage. [10] If there are diaphragms with abrupt discontinuities or variations in stiffness, including those having cutout or open areas comprising more than 50 percent of the gross enclosed diaphragm area, or changes in effective diaphragm stiffness of more than 50 percent from one storey to the next, the building is said to have a diaphragm discontinuity irregularity. The loss of cross-sectional area for the discontinuity shown in Figure. 2.10. is much smaller than 50 percent and would not qualify as a diaphragm irregularity. [10] Opening b a Figure. 2.9. Diaphragm Discontinuity Irregularity Area of opening > 0.50 ab (or) Changers in effective diaphragm stiffness from one storey to the next > 50% Tension Seismic Force Shear Wall Compression Figure. 2.10. Diaphragm Discontinuity 28 2.10.1.4. Out-of-plane offsets irregularity If there are discontinuities in a lateral force-resistance path, such as out-of-plane offset of vertical elements, out-of-plane offsets irregularity is defined to exists. [10] Walls Figure. 2.11. Out-of-plane Offsets Irregularity 2.10.1.5. Nonparallel systems irregularity If the vertical lateral force resisting elements are not parallel to or symmetric about the major orthogonal axes of the seismic force-resisting system, nonparallel systems irregularity is defined to exist. [10] Not a line symmetric Figure. 2.12. Nonparallel Systems Irregularity 2.10.2. Vertical Irregularity Vertical irregularities are abrupt changes in the geometry, strength, or stiffness of a structure from floor to floor. According to MNBC 2020, there are five types of vertical structural irregularities: [10] 1. (a) Stiffness irregularity – soft storey, (b) Stiffness irregularity – extreme soft storey 29 2. Weight irregularity, 3. Vertical geometric irregularity 4. In-plane discontinuity in vertical lateral-force resisting elements 5. (a) Weak storey. (b) Extreme weak storey 2.10.2.1. Stiffness irregularity – soft storey A category 1a soft storey is one in which the lateral stiffness is less than 70 percent of that in the storey above or less than 80 percent of the average stiffness of the three storeys above. This becomes an extreme soft-storey irregularity (category 1b) if the lateral stiffnesses is less than 60 percent of that in the storey above or less than 70 percent of the average stiffness of the three storeys above. The soft storey created by terminating or greatly reducing the stiffness of the shear walls of the ground storey, shown in Figure. 2.13, concentrates lateral deformation at this level. [10] Stiff Resisting Elements Figure. 2.13. Stiffness Irregularity – Soft Storey Soft storey stiffness < 70% of storey stiffness above (or) Soft storey stiffness < 80% of average stiffness of three storey above (Extreme soft storey) Soft storey stiffness < 60% of storey stiffness above (or) Soft storey stiffness < 70% of average stiffness of three storey above 2.10.2.2. Weight irregularity A weight irregularity exists where the effective mass of any storey exceeds 150 30 percent of the effective mass of an adjacent storey as shown in Figure.2.14. A roof that is lighter than the floor below need not to be considered. [10] Heavy Mass Figure. 2.14. Weight Irregularity Storey mass > 150% of adjacent storey mass 2.10.2.3. Vertical geometric irregularity This type of irregularity occurs when the horizontal dimension of the lateralforce-resisting system in any storey is more than 130 percent of that in an adjacent storey. The vertical geometric irregularity is shown in Figure 2.15. [10] Figure. 2.15. Vertical Geometric Irregularity Horizontal dimension of a lateral-force-resisting system in storey > 130% of that in an adjacent storey 2.10.2.4. In-plane discontinuity in vertical lateral-force-resisting elements An in-plane discontinuity is considered to exists where an in-plane offset of the lateral-force-resisting elements is greater than the length of those elements, as shown 31 in Figure. 2.16, or there exists a reduction in stiffness of the resisting element in the storey below. [10] Figure. 2.16. In-plane Discontinuity in Vertical Lateral-Force-Resisting Elements In-plane offset of lateral-force-resisting elements > lengths of those elements or reduction in stiffness of resisting elements in storey below 2.10.2.5. Weak storey A weak storey exists if the storey lateral strength of a storey is less than 80 percent that of the storey above. The lateral storey strength of a storey is the total strength of all lateral-force-resisting elements in the storey sharing the storey shear for the direction under consideration. A building with weak storey is shown in Figure. 2.17. An extreme weak storey exists if the storey lateral strength of a storey is less than 65 percent of that of the storey above. [10] Stiff Resisting Elements Weak Storey Figure. 2.17. Weak Storey 32 Weak storey strength < 80% of storey strength above Storey strength = total strength of seismic-force-resisting elements sharing storey shear for direction under consideration 2.11. Stability Checking of Superstructure After analyzing the structure, the stability of the structure should be checked. The stability checking for superstructure includes the following checking. 1. Storey Drift, 2. P-Δ Effect, 3. Overturning Moment, 4. Torsional Irregularities, 5. Stiffness Irregularity- Soft Storey, and 6. Sliding 2.11.1. Storey Drift Storey dirft is the horizontal deflection at the top of the storey relative to the bottom of the storey. The storey drift ratio is the storey drift divided by the storey height. The design storey drift (Δ) shall be computed as the difference of the deflections at the centers of mass at the top and bottom of the storey under consideration. The deflections of Level x at the center of the mass (δx) (in. or mm) shall be determined in accordance with the following equation: δx = Cd δx I Equation 2.9 Where, Cd = the deflection amplification factor δxe = the deflections determined by an elastic analysis I = the importance factor The design storey drift (Δ) shall not exceed the allowable Storey drift (Δa) as obtained by 0.020 times the storey height of the structure for any storey. For structures with significant torsional deflections, the maximum drift shall include torsional effects. For structures assigned to Seismic Design Category C, D, E, or F having horizontal irregularity Types 1a or 1b, the design storey drift, Δ, shall be computed as the largest difference of the deflections along any of the edges of the structure at the top and bottom of the storey under consideration. [5] 33 2.11.2. P-Δ effect An increase in the mass, internally generated inertial forces caused by vibration of the building mass, has two undesirable effects on the earthquake design. First, it results in an increase in the force, and second, it can cause buckling of vertical elements such as columns and walls when the mass pushing down exerts its force on a member bent or moved out of plumb by the lateral forces. This phenomenon is known as p-Δ effect. The greater the vertical force, the greater the movement due to p-Δ. P-Δ effect is the secondary effect on shears and moments of structural members due to the action of the vertical loads induced by horizontal displacement of the structure resulting from various loading conditions. [5] P-delta effects on storey shears and moments, the resulting member forces and moments, and the storey drifts induced by these effects are not required to be considered where the stability coefficient (θ) as determined by the following equation is equal to or less than 0.10: θ= Px ∆ Vx hsx Cd Equation 2.10 where, Px = the total vertical design load at and above Level x (kip or kN); where computing Px, no individual load factor need exceed 1.0 Δ = the design storey drift occurring simultaneously with Vx (in. or mm) Vx = the seismic shear force acting between Levels x and x −1 (kip or kN) hsx = the storey height below Level x (in. or mm) Cd = the deflection amplification factor in Table 3.4.7 The stability coefficient (θ) shall not exceed θmax determined as follows: θmax = Where, β 0.5 ≤ 0.25 βCd Equation 2.11 = the ratio of shear demand to shear capacity for the storey between Levels x and x−1. This ratio is permitted to be conservatively taken as 1.0. Where the stability coefficient (θ) is greater than 0.10 but less than or equal to max, the incremental factor related to P-delta effects on displacements and member forces shall be determined by rational analysis. Alternatively, it is permitted to multiply displacements and member forces by 1.0/(1− θ). [5] 34 Where θ is greater than θmax, the structure is potentially unstable and shall be redesigned. Where the P-delta effect is included in an automated analysis, Equation 2.11 shall still be satisfied, however, the value of θ computed from Equation 2.10 using the results of the P-delta analysis is permitted to be divided by (1 + θ) before checking Equation 2.11. [5] 2.11.3. Overturning Moment Overturning moment is quite literally the force that is attempting to overturn the structure. These moments are distributed to the various elements of vertical lateral under consideration designed to resist overturning effects caused by the seismic forces. At any level, the overturning moments to be resisted shall be using those seismic forces (Ft and Fx) that act on levels above the level under consideration. Overturning effects on every element shall be carried down to the foundation. The overturning moment Mx at level x is given by the following equation: [2] n Mx = ∑ Fi (hi − hx )+Ft (hin − hx ) Equation 2.12 i=x = (Bottom Shear × Storey Height) + Top Moment Where, Mx = overturning moment Ft = 0.07 × T × V = portion of V located at the top of the structure Fi = portion of V located at or assigned to level i T = period of the structure V = base shear R = response modification factor hi, hn, hx = height from the base to level i, n or x The safety factor is that the ratio of the resisting moment to overturning moment must be greater than 1.5. Factor of safety = Resisting Moment Overturning Moment 35 Resisting Moment = 0.9 × Total dead load × Center mass rigidity = 0.9 × Pd.l × Direction CM F.S > 1.5 2.11.4. Torsional Irregularities Damage of buildings observed in past earthquakes indicated that one major cause may be the torsional vibration induced by the ground motion. Torsional irregularities shall be considered when the maximum storey displacements caused by lateral load and accidental torsion at one end of structure transverse to an axis is more than 1.2 times the average of the storey displacement of the two ends of the structure. The presence of torsional irregularties implies seismic forces may be amplified due to eccentricity of seismic force. Torsional irregularity can be calculated from the following equation: δmax < 1.2 δavg Equation 2.13 Where, δmax = the maximum displacement at level x (in. or mm) δavg = the average of the displacements at extreme points of structure at level x Structures assigned to Seismic Design Category C, D, E, or F, where Type 1a or 1b torsional irregularity exists shall have the effects accounted for by multiplying Mta at each level by a torsional amplification factor (Ax) and determined from the following equation: δA δB Figure. 2.18. Checking for Torsional Irregularity [20MNBC] 36 2 δmax Ax = ( ) ≤ 3 1.2δavg Equation 2.14 Where, δmax = the maximum displacement at Level x (in. or mm) computed assuming Ax = 1 δavg = the average of the displacements at the extreme points of structure at Level x computed assuming (Ax = 1) = (δA+ δB)/2 (δA and δB from Figure. 2.18) 2.11.5. Stiffness Irregularity -Soft Storey The definition of soft storey in the code compares values of the lateral stiffness of individual stories. 1. The storey stiffness is less than 70 percent of that of the storey above. 2. The storey stiffness is less than 80 percent of the average stiffness of the three stories above. [2] If the stiffness of the storey is met at least one of the above two criteria, the structure is considered to have a soft storey and a dynamic analysis is required according to UBC-97. Generally, it is not practical to use stiffness properties unless these can be easily determined. There are many structural configurations where the evaluation of storey stiffness is complex and is often not an available output from computer programs. Floor level displacements and corresponding storey drift ratios are directly available from computer programs. To compare displacements rather than stiffness, it is necessary to use the reciprocal of the limiting percentage ratios of 70 and 80 percent as they apply to storey stiffness, or reverse their applicability to the storey and stories above. The storey drift ratio is the storey drift divided by the storey height. These will be used for the required comparisons, since these better represent the changes in the slope of the mode shape when there are significant differences in interstorey heights. In terms of the calculated storey drift ratios, the soft storey occurs when one of the following conditions exists: 1. When 70% of Δs1/h1 exceeds (Δs2-Δs1)/h2 2. When 80% of Δs1 /h1 exceeds 1 ∆s2 -∆s1 ∆s3 -∆s2 ∆s4 -∆s3 + + [ ] 3 h2 h3 h4 37 2.11.6. Sliding The term sliding friction refers to the resistance created by two objects sliding against each other. The factor of safety for sliding is founded by dividing the sliding resistance value by sliding causing force value and the value less than 1.5 is satisfied. Factor of safety = Resisting force due to friction Sliding force F.S > 1.5 Where, Resistance force due to friction = 0.9 × Total dead load × frictional coefficient Frictional coefficient = 0.25 Sliding Force = Base Shear 2.12. Natural Time Period of a Building The natural time period of a building is simply a time taken by it to undergo one complete cycle of oscillation. The natural period is one of the properties or building which is controlled by mass and stiffness. According to MNBC 2020, the approximate fundamental period (Ta), in s, shall be determined by the following equation: [5] Ta = Ct hnx Equation 2.15 Where, Ta = approximate fundamental period Ct = building period coefficient hn = the height in ft above the base to the highest level of the structure x = approximate period parameter CHAPTER 3 PREPARATION OF DESIGN DATA FOR PROPOSED BUILDING 3.1. General In this study, a 15-storied RC building is considered with vertical geometric irregularity at four different seismic locations: Bago, Nay Pyi Taw, Taunggyi and Yangon. Only superstructure is considered for analysis using Etabs 2016 software. The length of the structure below 6th floor is 134 ft and reduced to 94 ft above 6th floor. All structural members are designed according to ACI 318-08 and load considerations are according to MNBC-2020. The framing system of proposed building is moment resisting frame system with shear wall. When comparing the structural behaviours of the buildings, all models are considered the same frame system, load combinations and material properties. 3.2. Configuration of the Proposed Structure The proposed structure is considered as the vertical geometric irregular structure. The horizontal dimension of the proposed structure below 5th floor is 134 ft. Above 5th floor, the structure is reduced one bay – 20 ft in length – on two opposite sides of the structure; total length of 40 ft and the horizontal distance becomes 94 ft. This horizontal distance remains the same from that level to roof level. The setback forms at 5 th floor as the horizontal dimension reduced in the upper level. The elevation of setback lies 70 ft above ground level. The horizontal distance of the lower level of 5th floor is about 143% larger than that of upper adjacent floor. According to MNBC 2020, if the horizontal dimension of the seismic force–resisting system in any storey is more than 130% of that in an adjacent storey, then the vertical geometric irregularity exists in the structure. 3.3. Material Properties Material properties used for proposed buildings are as follows: Weight per unit volume of concrete = 150 pcf 39 Concrete compressive strength (f’c) = 4000 psi Yield strength of steel (fy) = 60000 psi Poisson’s ratio = 0.2 Modulus of Elasticity of concrete = 3.605 × 106 psi Coefficient of thermal expansion = 5.5 x 10-6 in/in per °F 3.4. Loading Considerations Loads are a primary consideration in any building design. The type and magnitude of design loads affect critical decisions such as material selection, construction details, and architectural configuration and it is essential to apply design loads realistically. In this study, dead load, live load, wind load and earthquake loads are considered according to MNBC 2020. 3.4.1 Dead load The following data are used for dead load in structural analysis and design. 3.4.2 1. Unit weight of concrete = 150 pcf 2. 4 ½” thick brick wall weight = 50 psf 3. 9” thick brick wall weight = 100 psf 4. Superimposed dead load on floor slab = 20 psf Live Load The following data are used for live load in structural analysis. 1. Live load on Car parking and landing = 100 psf 2. Live load on Shopping area floor = 75 psf 3. Live load on Office area floor = 50 psf 4. Live load on Residential floor and roof = 40 psf 5. Load on lift = 4480 lb 6. Water Load = 250 psf 3.4.3 Wind Load The following data are used for wind load in structural analysis. 1. Exposure type = Type B 2. Overall height = 198 ft 3. Effective height = 188 ft 4. Windward coefficient = 0.8 40 5. Leeward coefficient = 0.5 6. Important factor = 1 7. Basic wind speed for Bago = 80 mph 8. Basic wind speed for Nay Pyi Taw = 70 mph 9. Basic wind speed for Taunggyi = 70 mph 10. Basic wind speed for Yangon = 100 mph 3.4.4 Earthquake Load The required data for calculation of the earthquake loading are as follows: Soil profile type = SD Important Factor = 1 Table. 3.1. Seismic Parameters and Factors for Proposed Locations Location Ss Response Deflection Modification Amplification Factor Factor S1 Frame Type Bago 2.4 1.2 Special Moment Resisting Frame 8 5.5 Nay Pyi Taw 1.5 0.9 Special Moment Resisting Frame 8 5.5 Taunggyi 0.8 0.4 Intermediate Moment Resisting Frame 5 4.5 Yangon 0.7 0.2 Intermediate Moment Resisting Frame 5 4.5 3.4. Determination of Load Combinations The twenty-six numbers of load combinations are used in this study. 1. 1.4 DL 2. 1.2 DL + 1.6 LL 3. 1.2 DL + 1LL + 1.6 WX 4. 1.2 DL + 1LL – 1.6 WX 5. 1.2 DL + 1LL + 1.6 WY 6. 1.2 DL + 1LL – 1.6 WY 41 7. 1.2 DL + 0.8 WX 8. 1.2 DL – 0.8 WX 9. 1.2 DL + 0.8 WY 10. 1.2 DL – 0.8 WY 11. 0.9 DL + 1.6 WX 12. 0.9 DL – 1.6 WX 13. 0.9 DL + 1.6 WY 14. 0.9 DL – 1.6 WY 15. 1.2 DL + 1LL + 1EQX 16. 1.2 DL + 1LL – 1EQX 17. 1.2 DL + 1LL + 1EQY 18. 1.2 DL + 1LL – 1EQY 19. 0.9 DL + 1EQX 20. 0.9 DL – 1EQX 21. 0.9 DL + 1EQY 22. 0.9 DL – 1EQY 23. 1.2 DL + 1LL + 1SPECX 24. 1.2 DL + 1LL + 1SPECY 25. 0.9 DL + 1SPECX 26. 0.9 DL + 1SPECY CHAPTER 4 COMPARISON OF ANALYSIS RESULTS 4.1. General This chapter includes the analysis output results that obtained from analyzing the proposed 15-storied vertical geometric irregular reinforced concrete buildings at Bago, Nay Pyi Taw, Taunggyi and Yangon seismic locations by using ETABS 2016 software. The stability checking of superstructure such as storey drift P-Δ effect overturning moment torsional irregularity, soft storey and sliding are checked by response spectrum analysis under different seismic locations in this chapter. The comparison of the structural behaviours including storey drift, storey displacement, storey shear, overturning moment and the behaviours of structural members are discussed and presented in this chapter. 4.2. Sizes of Structural Members The structural members are analyzed according to moment resisting frame system and 26 numbers of load combinations are considered. The sizes of beams and columns used for comparison of the structural behaviour at different seismic locations are the same as each other for all locations. The structural members for all locations are as follows: 4.2.1. Sizes of Beams and Column The sizes of beams and columns used in 15-storied vertical geometric irregular reinforced concrete building under Bago, Nay Pyi Taw, Taunggyi and Yangon seismic locations are shown in Table 4.1 and Table 4.2, respectively. Table 4.1. Column Sizes Floor GF to 4F Column Sizes C 20″× 20″, C 24″× 24″, C 26″× 26″, C 28″× 28″, C 30″× 30″, C 32″× 32″ 43 Table 4.1. Column Sizes (Continued) Floor Column Sizes 5F to 8F C 20″× 20″, C 24″× 24″, C 26″× 26″, C 28″× 28″, C 30″× 30″, 9F to 12F C 22″× 22″, C 24″× 24″, C 26″× 26″, C 28″× 28″ 13F to RF C 20″× 20″, C 22″× 22″, C 24″× 24″, C 26″× 26″ RF-1 C 20″× 20″, C 22″× 22″ Table 4.2. Beam Sizes Main Beam Floor Exterior Interior GF B 16″×24″ B B 16″×20″ 14″×24″ 1F B 16″×24″ B 22″×24″ 2F B 14″×24″ B 22″×24″ 3F 4F 5F 6F 7F B 14″×24″ B 26″×20″ 9F B 26″×20″ 12F RF - B 16″× 20″ B 26″× 24″ B 12″×18″ B16″× 24″ B 14″× 24″ B 12″× 18″ B 10″×16″ B 10″×10″ B 28″× 24″ B 28″× 24″ B 12″× 20″ B 30″× 24″ - B16″× 20″ B 16″× 20″ - B 22″×24″ B 16″×20″ B 28″× 24″ - - B12″× 18″ 13F 14F Beams under Setback B 26″×20″ B 26″×22″ 11F Landing Beam B 16″× 24″ 8F 10F Secondary Cantilever Beam Beam B 12″× 18″ B 12″× 18″ B 10″×16″ B 12″× 18″ B 10″×10″ RF-1 - - - - 4.2.2. Thicknesses of Shear Wall and Slab The thickness of shear wall used in 15-storied vertical geometric irregular reinforced concrete building at four proposed locations is 14 inches and the thickness of ground floor slab is 7 inches, that of typical floor is 5 inches and that of landing and stairs is 6 inches. 44 4.3. Stability Checking According to MNBC-2020 In this study, the proposed building at Bago, Nay Pyi Taw, Taunggyi and Yangon seismic locations are analyzed with dynamic analysis for stability checking of superstructure. After that, the stability of superstructure such as storey drift, P-Δ effect, overturning moment, torsional irregularity, soft storey and slidingare carried out. 4.3.1. Checking for Storey Drift The checking for storey drift in X-direction and Y-direction at Bago for earthquake load effect are as shown in Table 4.3 and Table 4.4, respectively. The checking for storey drift at Nay Pyi Taw, Taunggyi and Yangon seismic locations are shown in Appendix B. Table 4.3. Checking for Storey Drift in X-direction Storey Level Height , h (ft) Cd Storey Drift Ratio δxe (in) RF-1 8 5.5 0.00115 0.11002 RF 10 5.5 0.00187 14F 10 5.5 13F 10 12F Cd δxe I Allowable Δa Remar k 0.61 1.92 OK 0.22416 1.23 2.4 OK 0.00220 0.26364 1.45 2.4 OK 5.5 0.00246 0.29484 1.62 2.4 OK 10 5.5 0.00255 0.30576 1.68 2.4 OK 11F 10 5.5 0.00257 0.30816 1.69 2.4 OK 10F 12 5.5 0.00282 0.40594 2.23 2.88 OK 9F 12 5.5 0.00299 0.43085 2.37 2.88 OK 8F 12 5.5 0.00296 0.42566 2.34 2.88 OK 7F 12 5.5 0.00286 0.41112 2.26 2.88 OK 6F 12 5.5 0.00285 0.40968 2.25 2.88 OK 5F 14 5.5 0.00287 0.48250 2.65 3.36 OK 4F 14 5.5 0.00297 0.49829 2.74 3.36 OK 3F 14 5.5 0.00290 0.48703 2.68 3.36 OK 2F 14 5.5 0.00280 0.47040 2.59 3.36 OK 1F 14 5.5 0.00253 0.42504 2.34 3.36 OK GF 10 5.5 0.00158 0.18996 1.04 2.4 OK δx = 45 Table 4.4. Checking for Storey Drift in Y-direction Cd δxe Allowable Remark Δa I Storey Height, Level h (ft) Cd Storey Drift Ratio δxe (in) RF-1 8 5.5 0.00111 0.10646 0.59 0.00111 OK RF 10 5.5 0.00163 0.19548 1.08 0.00163 OK 14F 10 5.5 0.00192 0.23088 1.27 0.00192 OK 13F 10 5.5 0.00217 0.26028 1.43 0.00217 OK 12F 10 5.5 0.00227 0.27264 1.50 0.00227 OK 11F 10 5.5 0.00232 0.27816 1.53 0.00232 OK 10F 12 5.5 0.00258 0.37195 2.05 0.00258 OK 9F 12 5.5 0.00278 0.39960 2.20 0.00278 OK 8F 12 5.5 0.00280 0.40320 2.22 0.00280 OK 7F 12 5.5 0.00272 0.39139 2.15 0.00272 OK 6F 12 5.5 0.00264 0.38074 2.09 0.00264 OK 5F 14 5.5 0.00266 0.44705 2.46 0.00266 OK 4F 14 5.5 0.00276 0.46418 2.55 0.00276 OK 3F 14 5.5 0.00279 0.46805 2.57 0.00279 OK 2F 14 5.5 0.00280 0.47006 2.59 0.00280 OK 1F 14 5.5 0.00260 0.43613 2.40 0.00260 OK GF 10 5.5 0.00165 0.19800 1.09 0.00165 OK δx = According to Table 4.3 and Table 4.4, the structure is stable because the Storey drift in X-direction and Y-direction is within the allowable limit 0.02h. 4.3.2. Checking for P-Δ Effect P-Δ effect checking for Bago is shown in Table 4.5 and Table 4.6 for X and Y direction. The checking for P-Δ effect at Nay Pyi Taw, Taunggyi and Yangon seismic locations are shown in Appendix B. Table 4.5. Checking for P-Δ Effect in X-direction Storey P Level (kips) Vx (kip) Cd Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) RF-1 223.4 50.2 5.5 2207.48 0.11002 2.05 0.00093 RF 2256.2 363.7 5.5 20001.19 0.22416 42.15 0.00211 14F 2231.6 699.1 5.5 38448.80 0.26364 49.03 0.00128 46 Table 4.5. Checking for P-Δ Effect in X-direction (Continued) Storey P Level (kips) Vx (kip) Cd Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) 13F 2231.6 960.0 5.5 52802.31 0.29484 54.83 0.00104 12F 2265.9 1172.2 5.5 64470.67 0.30576 57.73 0.00090 11F 2366.9 1353.1 5.5 74419.68 0.30816 60.78 0.00082 10F 2502.5 1516.0 5.5 100056.86 0.40594 84.65 0.00085 9F 2468.8 1640.3 5.5 108261.38 0.43085 88.64 0.00082 8F 2482.9 1742.6 5.5 115014.04 0.42566 88.07 0.00077 7F 2562.2 1839.8 5.5 121429.18 0.41112 87.78 0.00072 6F 2554.1 1941.3 5.5 128128.24 0.40968 87.20 0.00068 5F 3424.9 2089.0 5.5 160855.16 0.48250 137.71 0.00086 4F 3749.9 2250.3 5.5 173271.64 0.49829 155.71 0.00090 3F 3803.8 2409.5 5.5 185533.27 0.48703 154.38 0.00083 2F 3806.0 2552.7 5.5 196560.06 0.47040 149.19 0.00076 1F 3807.0 2661.6 5.5 204945.97 0.42504 134.84 0.00066 GF 4024.0 2704.0 5.5 148721.16 0.18996 63.70 0.00043 Stability Coefficient (θ) Table 4.6. Checking for P-Δ Effect in Y-direction Cd Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) 46.6 5.5 2050.4 0.10646 1.98 0.00097 2256.2 345.5 5.5 19002.0 0.19548 36.75 0.00193 14F 2231.6 675.7 5.5 37161.1 0.23088 42.94 0.00116 13F 2231.6 936.5 5.5 51506.1 0.26028 48.40 0.00094 12F 2265.9 1151.1 5.5 63312.5 0.27264 51.48 0.00081 11F 2366.9 1339.2 5.5 73655.3 0.27816 54.87 0.00074 10F 2502.5 1510.1 5.5 99667.4 0.37195 77.57 0.00078 9F 2468.8 1639.7 5.5 108219.6 0.39960 82.21 0.00076 8F 2482.9 1747.2 5.5 115316.1 0.40320 83.42 0.00072 7F 2562.2 1847.3 5.5 121923.0 0.39139 83.57 0.00069 6F 2554.1 1947.2 5.5 128514.6 0.38074 81.03 0.00063 5F 3424.9 2093.0 5.5 161163.5 0.44705 127.59 0.00079 4F 3749.9 2253.4 5.5 173511.2 0.46418 145.05 0.00084 Storey P Level (kips) Vy (kip) RF-1 223.4 RF 47 Table 4.6. Checking for P-Δ Effect in Y-direction (Continued) Storey P Level (kips) Vy (kip) Cd Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) 3F 3803.8 2410.9 5.5 185643.0 0.46805 148.36 0.00080 2F 3806.0 2555.2 5.5 196753.9 0.47006 149.09 0.00076 1F 3807.0 2663.5 5.5 205090.0 0.43613 138.36 0.00067 GF 4024.0 2704.0 5.5 148718.5 0.19800 66.40 0.00045 According to Table 4.5 and Table 4.6, the proposed building is stable because the stability coefficient of all stories in both X-direction and Y-direction is much less than the allowable limits, 0.1. 4.3.3. Checking for Overturning Moment Overturning moment for the building at Bago in X-direction and Y-direction is checked and described in the following tables. The checking for overturning moment at Nay Pyi Taw, Taunggyi and Yangon seismic locations are shown in Appendix B. Table 4.7. Checking for Overturning Moment in X-direction Storey Level Total D.L (kips) Resisting Moment C.M.M 0.9×P×C.M.M (kip-ft) Vx RF-1 195.6 67.1 11814.5 50.2 401 803 14.72 RF 1675.8 67.0 101057.7 363.7 4021 7657 13.20 14F 3521.9 67.0 212475.1 699.1 10957 17948 11.84 13F 5368.1 67.0 323851.8 960.0 20409 30009 10.79 12F 7248.5 67.0 437294.0 1172.2 31832 43554 10.04 11F 9230.0 67.0 556705.9 1353.1 44879 58410 9.53 10F 11346.5 67.0 684193.3 1516.0 62245 80437 8.51 9F 13346.1 67.0 804767.9 1640.3 80877 100560 8.00 8F 15359.7 67.0 926192.3 1742.6 100420 121331 7.63 7F 17452.7 67.0 1052399.6 1839.8 120676 142754 7.37 6F 19537.6 67.0 1178116.8 1941.3 141605 164901 7.14 5F 22332.7 67.0 1346663.4 2089.0 167015 196261 6.86 4F 25098.9 66.9 1511241.2 2250.3 193798 225302 6.71 3F 27917.9 66.9 1680998.0 2409.5 222220 255953 6.57 Additional Overturning Moment Moment F.S (kip-ft) (kip-ft) 48 Table 4.7. Checking for Overturning Moment in X-direction (Continued) Resisting Storey Total D.L Moment C.M.M Level (kips) 0.9×P×C.M.M (kip-ft) Vx Additional Overturning Moment Moment F.S (kip-ft) (kip-ft) 2F 30739.0 66.9 1850895.9 2552.7 252411 288149 6.42 1F 33561.2 66.9 2020826.5 2661.6 284306 321569 6.28 GF 36269.2 66.8 2180923.6 2704.0 307952 334992 6.51 Table 4.8. Checking for Overturning Moment in X-direction Resisting Storey Total D.L Moment C.M.M Level (kips) 0.9×P×C.M.M (kip-ft) Vx RF-1 195.6 50.2 8831.8 46.6 373 746 11.84 RF 14F 1675.8 3521.9 50.1 50.1 75609.9 158819.5 345.5 675.7 3814 10534 7269 17291 10.40 9.19 13F 5368.1 50.1 241988.2 936.5 19794 29158 8.30 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F GF 7248.5 9230.0 11346.5 13346.1 15359.7 17452.7 19537.6 22332.7 25098.9 27917.9 30739.0 33561.2 36269.2 50.1 50.1 50.1 50.1 50.1 50.1 50.1 50.1 50.6 50.6 50.6 50.6 50.2 326746.8 416036.5 511368.1 601805.4 692596.9 786907.4 880936.0 1006500.2 1143323.2 1271573.5 1399882.5 1528451.0 1639999.1 1151.1 1339.2 1510.1 1639.7 1747.2 1847.3 1947.2 2093.0 2253.4 2410.9 2555.2 2663.5 2704.0 31065 44033 61427 80189 99949 120493 141737 167526 194664 223399 253861 285989 309772 42576 57425 79549 99866 120916 142661 165104 196828 226211 257153 289635 323278 336812 7.67 7.24 6.43 6.03 5.73 5.52 5.34 5.11 5.05 4.94 4.83 4.73 4.87 Additional Overturning Moment Moment F.S (kip-ft) (kip-ft) From Table 4.7 and Table 4.8, the factor of safety is greater than the allowable limit 1.5. So, the structure is stable in both X and Y direction. 4.3.4. Checking for Torsional Irregularity Torsional irregularity of the structure at Bago seismic location is as shown in Table 4.9 and 4.10 for X and Y direction, respectively. The checking for torsional 49 irregularity at Nay Pyi Taw, Taunggyi and Yangon seismic locations are shown in Appendix B. Table 4.9. Checking for Torsional Irregularity in X-direction Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark RF 0.45648 0.45648 0.45648 0.45648 1 OK 14F 0.44182 0.44182 0.44182 0.44182 1 OK 13F 0.42471 0.42471 0.42471 0.42471 1 OK 12F 0.40542 0.40542 0.40542 0.40542 1 OK 11F 0.38502 0.38502 0.38502 0.38502 1 OK 10F 0.36389 0.36389 0.36389 0.36389 1 OK 9F 0.33536 0.33536 0.33536 0.33536 1 OK 8F 0.30445 0.30445 0.30445 0.30445 1 OK 7F 0.27315 0.27315 0.27315 0.27315 1 OK 6F 0.24201 0.24201 0.24201 0.24201 1 OK 5F 0.21008 0.21008 0.21008 0.21008 1 OK 4F 0.17134 0.17134 0.17134 0.17134 1 OK 3F 0.13059 0.13059 0.13059 0.13059 1 OK 2F 0.09034 0.09034 0.09034 0.09034 1 OK 1F 0.05124 0.05124 0.05124 0.05124 1 OK GF 0.01583 0.01583 0.01583 0.01583 1 OK Table 4.10. Checking for Torsional Irregularity in Y-direction Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark RF 0.43231 0.43231 0.43231 0.43231 1 OK 14F 0.41918 0.41918 0.41918 0.41918 1 OK 13F 0.40382 0.40382 0.40382 0.40382 1 OK 12F 0.38642 0.38642 0.38642 0.38642 1 OK 11F 0.3679 0.3679 0.3679 0.3679 1 OK 10F 0.34859 0.34859 0.34859 0.34859 1 OK 9F 0.32221 0.32221 0.32221 0.32221 1 OK 8F 0.29336 0.29336 0.29336 0.29336 1 OK 7F 0.26359 0.26359 0.26359 0.26359 1 OK 50 Table 4.10. Checking for Torsional Irregularity in Y-direction (Continued) Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark 6F 0.23395 0.23395 0.23395 0.23395 1 OK 5F 0.20434 0.20434 0.20434 0.20434 1 OK 4F 0.16854 0.16854 0.16854 0.16854 1 OK 3F 0.13062 0.13062 0.13062 0.13062 1 OK 2F 0.09192 0.09192 0.09192 0.09192 1 OK 1F 0.05283 0.05283 0.05283 0.05283 1 OK GF 0.01650 0.01650 0.01650 0.01650 1 OK Table 4.9 and Table 4.10 show that the ratio of the maximum displacement to average displacement is less than 1.2. Therefore, the stability of the structure is satisfied for torsional irregularity. 4.3.5. Checking for Soft Storey Checking for soft storey in X-direction and Y-direction at Bago seismic location are described in the following tables. The checking for soft storey at Nay Pyi Taw, Taunggyi and Yangon seismic locations are shown in Appendix B. Table 4.11. Checking for Soft Storey in X-direction (Case I) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.00100 0.00110 No 0.00220 0.00154 0.00187 No 10 0.00246 0.00172 0.00220 No 12F 10 0.00255 0.00178 0.00246 No 11F 10 0.00257 0.00180 0.00255 No 10F 12 0.00282 0.00197 0.00257 No 9F 12 0.00299 0.00209 0.00282 No 8F 12 0.00296 0.00207 0.00299 No 7F 12 0.00286 0.00200 0.00296 No 6F 12 0.00285 0.00199 0.00286 No 5F 14 0.00287 0.00201 0.00285 No 4F 14 0.00297 0.00208 0.00287 No Storey Level Height (ft) Storey Drift Ratio RF-1 8 0.00110 0.00080 RF 10 0.00187 14F 10 13F 70% ( 51 Table 4.11. Checking for Soft Storey in X-direction (Case I) (Continued) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.00290 0.00203 0.00297 No 14 0.00280 0.00196 0.00290 No 1F 14 0.00253 0.00177 0.00280 No GF 10 0.00158 0.00111 0.00253 No Δ2 - Δ1 h2 Soft Storey Status Storey Level Height (ft) Storey Drift Ratio 3F 14 2F 70% ( Table 4.12. Checking for Soft Storey in Y-direction (Case I) Δ1 ) h1 Storey Level Height (ft) Storey Drift Ratio RF-1 8 0.00111 0.0008 RF 10 0.00163 0.0011 0.00111 No 14F 10 0.00192 0.0013 0.0016 No 13F 10 0.00217 0.0015 0.0019 No 12F 10 0.00227 0.0016 0.0022 No 11F 10 0.00232 0.0016 0.0023 No 10F 12 0.00258 0.0018 0.0023 No 9F 12 0.00278 0.0019 0.0026 No 8F 12 0.0028 0.0020 0.0028 No 7F 12 0.00272 0.0019 0.0028 No 6F 12 0.00264 0.0019 0.0027 No 5F 14 0.00266 0.0019 0.0026 No 4F 14 0.00276 0.0019 0.0027 No 3F 14 0.00279 0.0020 0.0028 No 2F 14 0.0028 0.0020 0.0028 No 1F 14 0.0026 0.0018 0.0028 No GF 10 0.00165 0.0012 0.0026 No Δ1 +Δ2 +Δ3 3h Soft Storey Status 70% ( Table 4.13. Checking for Soft Storey in X-direction (Case II) Δ1 ) h1 Storey Level Height Storey Drift Ratio RF-1 8 0.00115 0.001 RF 10 0.00187 0.00149 80% ( 52 Table 4.13. Checking for Soft Storey in X-direction (Case II) (Continued) Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.00170 0.00174 No 0.00255 0.00204 0.00217 No 10 0.00257 0.00205 0.00240 No 10F 12 0.00282 0.00226 0.00252 No 9F 12 0.00299 0.00239 0.00265 No 8F 12 0.00296 0.00236 0.00279 No 7F 12 0.00286 0.00228 0.00292 No 6F 12 0.00285 0.00228 0.00293 No 5F 14 0.00287 0.00230 0.00289 No 4F 14 0.00297 0.00237 0.00286 No 3F 14 0.0029 0.00232 0.00289 No 2F 14 0.0028 0.00224 0.00291 No 1F 14 0.00253 0.00202 0.00289 No GF 10 0.00158 0.00127 0.00274 No Δ1 +Δ2 +Δ3 3h Soft Storey Status Height Storey Drift Ratio Δ1 80% ( ) h1 14F 10 0.0022 0.00176 13F 10 0.00246 12F 10 11F Storey Level Table 4.14. Checking for Soft Storey in Y-direction (Case II) Height Storey Drift Ratio Δ1 80% ( ) h1 RF-1 8 0.00111 0.0009 RF 10 0.00163 0.00130 14F 10 0.00192 0.0015 13F 10 0.00217 0.002 0.002 No 12F 10 0.00227 0.0018 0.00191 No 11F 10 0.00232 0.0019 0.00212 No 10F 12 0.00258 0.0021 0.00225 No 9F 12 0.00278 0.0022 0.00239 No 8F 12 0.0028 0.0022 0.00256 No 7F 12 0.00272 0.0022 0.00272 No 6F 12 0.00264 0.0021 0.00276 No 5F 14 0.00266 0.0021 0.00272 No Storey Level 53 Table 4.14. Checking for Soft Storey in Y-direction (Case II) (Continued) Δ1 ) h1 Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.00276 0.0022 0.00267 No 14 0.00279 0.0022 0.00269 No 2F 14 0.0028 0.0022 0.00274 No 1F 14 0.0026 0.0021 0.00278 No GF 10 0.00165 0.0013 0.00273 No Storey Level Height Storey Drift Ratio 4F 14 3F 80% ( From the above tables, the soft storey does not exist in the proposed building. 4.3.6. Checking for Sliding Checking for sliding in X-direction and Y-direction at Bago seismic location are described in Table 4.15 and Table 4.16, respectively. The checking for sliding at Nay Pyi Taw, Taunggyi and Yangon seismic locations are shown in Appendix B. Table 4.15. Checking for Sliding in X-direction Storey Height (ft) Total DL (kips) Vx (kips) Resistance due to friciton Sliding Force S.F Remark RF 10 1675.78 363.66 546.98 363.66 1.50 OK 14F 10 3521.92 699.07 1053.23 699.07 1.51 OK 13F 10 5368.06 960.04 1455.30 960.04 1.52 OK 12F 10 7248.50 1172.19 1782.23 1172.19 1.52 OK 11F 10 9229.97 1353.09 2076.74 1353.09 1.53 OK 10F 12 11346.49 1516.01 2552.96 1516.01 1.68 OK 9F 12 13346.07 1640.32 3002.87 1640.32 1.83 OK 8F 12 15359.74 1742.64 3455.94 1742.64 1.98 OK 7F 12 17452.73 1839.84 3926.86 1839.84 2.13 OK 6F 12 19537.59 1941.34 4395.96 1941.34 2.26 OK 5F 14 22332.73 2089.03 5024.86 2089.03 2.41 OK 4F 14 25098.87 2250.28 5647.25 2250.28 2.51 OK 3F 14 27917.87 2409.52 6281.52 2409.52 2.61 OK 2F 14 30739.02 2552.73 6916.28 2552.73 2.71 OK 1F 14 33561.17 2661.64 7551.26 2661.64 2.84 OK GF 10 36269.17 2704.02 8160.56 2704.02 3.02 OK 54 Table 4.16. Checking for Sliding in Y-direction Storey Height (ft) Total DL (kips) Vx (kips) RF 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F GF 10 10 10 10 10 12 12 12 12 12 14 14 14 14 14 10 1675.78 3521.92 5368.06 7248.50 9229.97 11346.49 13346.07 15359.74 17452.73 19537.59 22332.73 25098.87 27917.87 30739.02 33561.17 36269.17 345.49 675.66 936.47 1151.14 1339.19 1510.11 1639.69 1747.21 1847.32 1947.19 2093.03 2253.39 2410.95 2555.25 2663.51 2703.97 Resistance due to friction 520.88 1021.73 1417.05 1754.55 2076.74 2552.96 3002.87 3455.94 3926.86 4395.96 5024.86 5647.25 6281.52 6916.28 7551.26 8160.56 Sliding Force S.F Remark 345.49 675.66 936.47 1151.14 1339.19 1510.11 1639.69 1747.21 1847.32 1947.19 2093.03 2253.39 2410.95 2555.25 2663.51 2703.97 1.51 1.51 1.51 1.52 1.55 1.69 1.83 1.98 2.13 2.26 2.40 2.51 2.61 2.71 2.84 3.02 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK From the above tables, the safety factors at all storey in X-direction and Ydirection are greater than 1.5 and the building is stable. 4.4. Time period The time period of the structure mainly depends on the stiffness and mass of the structure. As the size and shape of the two buildings are the same, the time period for both locations are also the same. According to MNBC 2020, the number of modes should be sufficient to obtain a combined modal mass participation of at least 90 percent of the actual mass in each of the orthogonal horizontal directions of response considered by the model and the 15 numbers of modes in the analysis is used. Time period (sec) resulted from the analysis based on 15 modes for all of the proposed buildings are shown in Table 4.17. 5 6 7 8 9 10 11 12 13 14 15 Time Period(sec) 2.06 1.52 0.75 0.73 0.57 0.42 0.41 0.31 0.28 0.14 4 0.19 3 0.19 2 0.20 1 0.27 Mode 2.10 Table 4.17. Time Period of the Structure 55 4.5. Comparison of Results for Storey Drift The storey drift is the horizontal deflection at the top of the storey relative to the bottom of the storey and can be computed as the difference of the deflection at the centers of mass at the top and bottom of the storey under consideration. The limitation of storey drift for the high-rise RC structure is that the calculated storey drift shall not exceed 0.02 times the storey height as described in MNBC 2020. The analysis results of storey drift in X-direction and Y-direction at Bago, Nay Pyi Taw, Taunggyi and Yangon seismic locations are shown in Table 4.18 and Table 4.19. Table 4.18. Analysis Results of Storey Drift in X-direction Storey Storey Drift (inch) Bago Nay Pyi Taw Taunggyi Yangon GF 0.18996 0.14304 0.1026 0.06384 1F 0.42504 0.321384 0.22949 0.14179 2F 0.4704 0.358008 0.25351 0.15557 3F 0.48703 0.373296 0.26225 0.16044 4F 0.49829 0.384552 0.26846 0.16464 5F 0.4825 0.3738 0.26006 0.16027 6F 0.40968 0.316944 0.2209 0.13651 7F 0.41112 0.316224 0.22176 0.13709 8F 0.42566 0.324432 0.22968 0.14155 9F 0.43085 0.32472 0.23242 0.1427 10F 0.40594 0.302544 0.21902 0.13435 11F 0.30816 0.22692 0.16644 0.1026 12F 0.30576 0.2226 0.1656 0.10344 13F 0.29484 0.2124 0.1602 0.10188 14F 0.26364 0.18876 0.14364 0.09288 RF 0.22416 0.16008 0.1224 0.07992 RF-1 0.110016 0.078144 0.060384 0.040416 Table 4.19. Analysis Results of Storey Drift in Y-direction Storey Storey Drift (inch) Bago Nay Pyi Taw Taunggyi Yangon GF 0.198 0.14904 0.10956 0.06792 1F 0.436128 0.329448 0.241248 0.14868 2F 0.470064 0.357168 0.25956 0.158928 56 Table 4.19. Analysis Results of Storey Drift in Y-direction (Continued) Storey Storey Drift (inch) Bago Nay Pyi Taw Taunggyi Yangon 3F 0.468048 0.358344 0.25788 0.157584 4F 0.464184 0.357504 0.25536 0.156576 5F 0.447048 0.34524 0.245784 0.151368 6F 0.380736 0.293472 0.209376 0.129312 7F 0.391392 0.299808 0.215568 0.133056 8F 0.4032 0.306144 0.22248 0.136944 9F 0.3996 0.30024 0.22104 0.135648 10F 0.371952 0.27648 0.206208 0.126576 11F 0.27816 0.2046 0.15456 0.0954 12F 0.27264 0.19848 0.15204 0.09504 13F 0.26028 0.18768 0.14568 0.09252 14F 0.23088 0.16548 0.1296 0.08364 RF 0.19548 0.13992 0.10992 0.07152 RF-1 0.106464 0.07536 0.060192 0.04032 The comparison of the analysis results in X-direction and Y-direction at Bago, Nay Pyi Taw, Taunggyi and Yangon described in the above table are illustrated in Figure 4.1 and Figure 4.2. 0.6 Storey Drift (inch) 0.5 0.4 0.3 0.2 0.1 0 Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.1. Comparison of Storey Drift in X-direction 57 Storey Drift (inch) 0.5 0.4 0.3 0.2 0.1 0 Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.2. Comparison of Storey Drift in Y-direction According to Figure 4.1 and Figure 4.2, it can be observed that the storey drift depends largely on the change in seismic location. The larger the seismic parameter, the greater the storey drift. All of the buildings are in the same shape with same sizes of members, the shape of curves produced associated with the storey drift and storey level are in the same manner as each other of different seismic locations. It can be seen in both of the figures that the maximum storey drift is maximum at the level under setback and minimum at top roof. There is a fluctuation at 6th floor and 11th floor where the floor heights are changed. The maximum storey drift of Nay Pyi Taw is 28%, that of Taunggyi is 48% and that of Yangon is 68% smaller than that of Bago in both X and Y directions. And the minimum storey drift in both X and Y directions of Nay Pyi Taw is 29%, that of Taunggyi is 43% and that of Yangon is 62% smaller than that of Bago. 4.6. Comparison of Results for Storey Shear The storey shear of the storey is the summation of design lateral seismic forces at levels above the storey under consideration. The analysis results of the storey shear in X-direction and Y-direction result from the maximum seismic force at Bago, Nay Pyi Taw, Taunggyi and Yangon seismic locations are described in the following Table 4.20 and Table 4.21. 58 Table 4.20. Analysis Results of Storey Shear in X-direction Storey Storey Shear (kips) Bago Nay Pyi Taw Taunggyi Yangon GF 2704.02 2028.016 1463.54 917.973 1F 2661.64 2002.082 1438.81 896.174 2F 2552.73 1933.518 1377.01 847.479 3F 2409.52 1839.765 1298.65 796.39 4F 2250.28 1731.066 1213.34 747.928 5F 2089.03 1614.18 1127.71 701.18 6F 1941.34 1498.25 1048.96 655.861 7F 1839.84 1411.43 994.283 621.402 8F 1742.64 1322.897 941.601 586.158 9F 1640.32 1228.933 886.138 549.07 10F 1516.01 1119.91 819.12 506.493 11F 1353.09 984.414 732.277 455.896 12F 1172.19 839.664 636.799 404.634 13F 960.042 677.542 524.731 344.77 14F 699.069 486.043 385.519 265.033 RF 363.658 248.692 202.956 147.023 RF-1 50.17 33.637 28.428 21.745 Table 4.21. Analysis Results of Storey Shear in Y-direction Storey Storey Shear (kips) Bago Nay Pyi Taw Taunggyi Yangon GF 2703.97 2027.98 1498.54 934.846 1F 2663.51 2002.84 1474.38 914.78 2F 2555.25 1934.225 1410.83 866.651 3F 2410.95 1839.268 1328.43 813.91 4F 2253.39 1730.535 1240.51 764.658 5F 2093.03 1613.535 1152.06 714.937 6F 1947.19 1498.096 1072.77 668.254 7F 1847.32 1411.779 1019.33 634.872 8F 1747.21 1321.531 965.937 599.208 9F 1639.69 1224.557 908.677 561.69 59 Table 4.21. Analysis Results of Storey Shear in Y-direction Storey Shear (kips) Storey Bago Nay Pyi Taw Taunggyi Yangon 10F 1510.11 1112.463 839.352 519.137 11F 1339.19 972.736 747.051 465.204 12F 1151.14 824.233 645.314 409.384 13F 936.474 660.857 528.484 346.35 14F 675.656 470.097 384.378 262.649 RF 345.49 237.125 198.302 141.702 RF-1 46.601 31.588 27.005 20.209 The analysis results of the storey shear for the proposed vertical geometric irregular building at four different seismic locations are compared and described in Figure 4.3 and Figure 4.4 in X-direction and Y-direction, respectively. Storey Shear (kips) 3000 2500 2000 1500 1000 500 0 Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.3. Comparison of Storey Shear in X-direction The storey shear depends on the weight of the structure. The lower the level, the higher the storey shear. It can be seen that the storey shear in both X-direction and Ydirection is the largest at the ground floor and smallest at the roof level. The shear forces between stories changes steadily. Since there is a sudden change in the horizontal dimension at setback, the storey shear decreases slightly near 5th floor. The 60 discontinuity of the size of the structure makes the storey shear to change suddenly. 3000 Storey Shear (kips) 2500 2000 1500 1000 500 0 Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.4. Comparison of Storey Shear in Y-direction From the above comparison results, the storey shear of the building at Bago where the seismic parameters are largest is maximum and that of the building at Yangon where the seismic parameters are smallest is minimum. The maximum storey shear at the four locations is in the range of 914 kips and 2704 kips and minimum storey shear at the four different seismic locations are in the range of 21 kips and 50 kips. The storey shear of the building at Nay Pyi Taw, Taunggyi and Yangon are 25%, 46% and 66% smaller in both X-direction and Y-direction than that of the building at Bago seismic location. The values of storey shear of four locations have shown that the storey shear also increases with higher Ss and S1. 4.7. Comparison of Results for Storey Displacement The storey displacement of a storey is the absolute value of displacement of that storey under action of the lateral forces. The displacement of the building at larger seismic parameters is more than that of the building at lower seismic parameters. Storey displacement depends on height and slenderness of the structure. The structure is more sway if the height of the structure increases. The analysis results of the storey displacement in X and Y directions at four different seismic locations are tabulated in Table 4.22 and Table 4.23. 61 Table 4.22. Analysis Results of Storey Displacement in X-direction Storey Storey Displacement (inch) Bago Nay Pyi Taw Taunggyi Yangon GF 0.015827 0.011925 0.008553 0.005321 1F 0.051237 0.038704 0.027666 0.017136 2F 0.090343 0.068482 0.048737 0.030036 3F 0.130592 0.099405 0.070391 0.043186 4F 0.171341 0.131015 0.092297 0.056453 5F 0.210076 0.161354 0.113117 0.069082 6F 0.242014 0.186569 0.130286 0.07953 7F 0.273153 0.211232 0.147029 0.089748 8F 0.304453 0.236004 0.163864 0.100033 9F 0.33536 0.260344 0.180489 0.110182 10F 0.363892 0.282645 0.195836 0.119533 11F 0.385015 0.299022 0.207198 0.126441 12F 0.405421 0.314711 0.218179 0.133118 13F 0.424707 0.329401 0.228567 0.139457 14F 0.441824 0.342327 0.237799 0.145131 RF 0.456482 0.353323 0.245715 0.150032 Table 4.23. Analysis Results of Storey Displacement in Y-direction Storey Storey Displacement (inch) Bago Nay Pyi Taw Taunggyi Yangon GF 0.016495 0.01242 0.009133 0.005657 1F 0.052828 0.039869 0.029231 0.01804 2F 0.091915 0.06959 0.050809 0.031226 3F 0.130617 0.099272 0.072112 0.044163 4F 0.168539 0.128635 0.092922 0.056777 5F 0.204336 0.156614 0.11252 0.068677 6F 0.233954 0.17992 0.128709 0.078532 7F 0.26359 0.203294 0.144904 0.088412 8F 0.293356 0.226728 0.161177 0.098347 62 Table 4.23. Analysis Results of Storey Displacement in Y-direction (Continued) Storey Storey Displacement (inch) Bago Nay Pyi Taw Taunggyi Yangon 9F 0.322214 0.249333 0.176973 0.107984 10F 0.348585 0.26984 0.19143 0.116791 11F 0.367904 0.284751 0.202038 0.123245 12F 0.386423 0.298938 0.212225 0.129446 13F 0.403816 0.312153 0.221815 0.135306 14F 0.419178 0.323738 0.230305 0.140526 RF 0.432311 0.333587 0.237577 0.145027 The results of the storey displacement from the analysis of the structure in X Storey Displacement (inch) and Y directions are compared and shown in Figure 4.5 and Figure 4.6. 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 GF 1F 2F 3F 4F 5F 6F 7F 8F 9F 10F 11F 12F 13F 14F RF Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.5. Comparison of Storey Displacement in X-direction In the comparison of the storey displacement, the structure displaces more when the seismic parameters of the location are larger. The storey displacement of a building is smallest at the ground floor and largest at the roof level. In Figure 4.5 and Figure 4.6, it can be seen that the differences in storey displacement between all locations are largest at the roof and are nearly the same at the ground floor. The roof level of the structure at Nay Pyi Taw displaces 23%, Taunggyi 46%, and Yangon displaces 67% less than Bago in X direction. In Y-direction, the value 63 of the displacement on roof level of the structure is 23% for Nay Pyi Taw, 45% for Taunggyi, and 66% for Yangon smaller than Bago seismic location. The structures are in the same shape with the same member sizes, the curves of the storey displacement with respect to storey level are in the same shape as each other. The value of storey displacement of the structure changes depending on the location with different seismic parameters. The larger the seismic parameter, the larger will be the value of the storey Storey Displaccement (inch) displacements of the structure. 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 GF 1F 2F 3F 4F 5F 6F 7F 8F 9F 10F 11F 12F 13F 14F RF Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.6. Comparison of Storey Displacement in Y-direction 4.8. Comparison of Results for Overturning Moment When structures are subjected to lateral forces, they undergo deflection in the lateral direction and lateral sway is also observed in one direction of the structure. This causes structure to experience overturning. The values of overturning moment result from the analysis of the structure in both directions at four different locations are shown in the following tables Table 4.24 and Table 4.25, respectively. Table 4.24. Analysis Results of Overturning Moment in X-direction Storey GF Overturning Moment (kip-ft) Bago Nay Pyi Taw Taunggyi Yangon 334992 259476 180371 110332 64 Table 4.24. Analysis Results of Overturning Moment in X-direction (Continued) Storey Overturning Moment (kip-ft) Bago Nay Pyi Taw Taunggyi Yangon 1F 321569 248806 173148 105900 2F 288149 222750 155133 94780 3F 255953 197388 137819 84224 4F 225302 173000 121358 74255 5F 196261 149718 105767 64808 6F 164901 124634 88910 54523 7F 142754 106956 77009 47286 8F 121331 90011 65503 40329 9F 100560 73816 54356 33650 10F 80437 58391 43563 27241 11F 58410 41860 31742 20222 12F 43554 30867 23769 15492 13F 30009 21032 16469 11054 14F 17948 12433 9924 6906 RF 7657 5232 4276 3106 RF-1 803 538 455 348 Table 4.25. Analysis Results of Overturning Moment in Y-direction Storey Overturning Moment (kip-ft) Bago Nay Pyi Taw Taunggyi Yangon GF 336812 260066 185026 113127 1F 323278 249323 177640 108610 2F 289635 223129 159183 97248 3F 257153 197600 141422 86431 4F 226211 173052 124553 76225 5F 196828 149600 108550 66521 6F 165104 124351 91250 55975 7F 142661 106541 79006 48545 8F 120916 89455 67119 41360 65 Table 4.25. Analysis Results of Overturning Moment in Y-direction (continued) Overturning Moment (kip-ft) Storey Bago Nay Pyi Taw Taunggyi Yangon 9F 99866 73143 55584 34445 10F 79549 57650 44420 27803 11F 57425 41119 32206 20510 12F 42576 30167 23987 15601 13F 29158 20441 16517 11041 14F 17291 11993 9857 6806 RF 7269 4986 4174 2990 RF-1 746 505 432 323 The value of overturning moment depends upon and directly proportional to the storey shear of a building. In this study, the maximum overturning moment is observed at the ground floor and the minimum at the roof level at all the considered locations. The comparison results of overturning moment for the different seismic locations in X direction and Y direction are described in Figure 4.7 and Figure 4.8. 400000 Overturning Moment (kft) 350000 300000 250000 200000 150000 100000 50000 0 Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.7. Comparison of Overturning Moment in X-direction 66 Overturning Moment (kft) 400000 350000 300000 250000 200000 150000 100000 50000 0 Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.8. Comparison of Overturning Moment in Y-direction The overturning moment at location where seismic parameters are larger is much larger than the one at location where the seismic parameters are smaller. The value in X-direction and Y-direction are similar in every storey at all locations. From Figure 4.7 and Figure 4.8, it is observed that the maximum overturning moments in X and Y directions on the ground floor of the proposed structure at Nay Pyi Taw, Taunggyi and Yangon are about 23%, about 45% and about 66% smaller than that of the structure at Bago seismic location. The values of overturning moment at the roof level of all locations are nearly the same as each other. 4.9. Comparison of Results for Storey Stiffness As the proposed building is vertical geometric irregular building, the stiffness of the structure becomes discontinuous. The stiffness of the structure depends on the weight of the structure. As the weight of all the structure are the same, the stiffness of the building at four locations are nearly the same as each other. The stiffness in X and Y-directions at four different locations are shown in Table 4.26 and Table 4.27. Table 4.26. Comparison of Storey Stiffness in X-direction Storey GF Stiffness X (kip/ft) Bago Nay Pyi Taw Taunggyi Yangon 171345.335 170581.477 171605.599 173047.297 67 Table 4.26. Comparison of Storey Stiffness in X-direction (Continued) Storey Stiffness X (kip/ft) Bago Nay Pyi Taw Taunggyi Yangon 1F 75586.738 75196.814 75690.321 76256.96 2F 67506.853 67362.465 67511.992 67534.053 3F 60353.967 60288.917 60379.969 60489.512 4F 54831.731 54805.223 54891.43 55261.189 5F 51444.106 51388.02 51535.664 52121.235 6F 57159.495 57012.896 57266.413 57915.619 7F 52915.617 52649.983 53017.617 53613.344 8F 49936.821 49591.387 50024.686 50482.61 9F 45824.041 45279.833 45897.393 46214.253 10F 43716.275 43125.095 43787.57 44116.271 11F 52726.023 52083.575 52830.452 53350.429 12F 45942.93 44986.789 46133.469 47167.542 13F 38594.563 37616.906 38897.954 40545.387 14F 30388.893 29415.34 30808.643 33033.62 RF 18186.565 17394.854 18614.535 20756.277 RF-1 5483.65 5178.365 5666.675 6480.905 Table 4.27. Comparison of Storey Stiffness in Y-direction Storey Stiffness X (kip/ft) Bago Nay Pyi Taw Taunggyi Yangon GF 163962.257 163302.59 164124.429 165308.044 1F 73306.632 72963.448 73354.881 73859.782 2F 63979.996 63949.109 63942.465 63910.512 3F 60908.961 60919.819 60885.429 60998.513 4F 57397.402 57362.73 57479.377 57780.657 5F 53277.363 53186.97 53300.268 53740.125 6F 61395.193 61276.18 61482.488 62051.984 7F 55351.15 54983.987 55485.996 55956.042 68 Table 4.27. Comparison of Storey Stiffness in Y-direction (Continued) Stiffness X (kip/ft) Storey Bago Nay Pyi Taw Taunggyi Yangon 8F 52742.56 52378.279 52861.622 53219.702 9F 48632.586 48190.964 48745.951 49031.027 10F 46951.385 46303.366 47124.745 47451.475 11F 57802.064 57076.736 58006.612 58513.765 12F 50187.269 49227.058 50494.875 51578.777 13F 42103.268 41029.334 42502.663 44160.553 14F 33030.052 31968.29 33509.385 35762.117 RF 19433.022 18632.138 19844.68 21870.459 RF-1 5386.285 5164.043 5515.194 6142.474 The comparison of the storey stiffness in X-direction and Y-directions at Bago, Nay Pyi Taw, Taunggyi and Yangon seismic location are shown in Figure 4.9 and Figure 4.10. 200000 180000 Storey Stiffness (kip/ft) 160000 140000 120000 100000 80000 60000 40000 20000 0 Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.9. Comparison of Storey Stiffness in X-direction 69 200000 180000 Storey Stiffness (kip/ft) 160000 140000 120000 100000 80000 60000 40000 20000 0 Storey Level Bago Nay Pyi Taw Taunggyi Yangon Figure 4.10. Comparison of Storey Stiffness in Y-direction From Figure 4.9 and Figure 4.10, it can be seen that the storey stiffness of the structure at the ground floor is the largest and that of at roof level is the lowest and all the locations result in nearly the same stiffness in both direction at four locations. It is because the weight of the structure is the same for all locations. As can be observed from the figure, the storey stiffness above ground floor reduced sharply from over 170000 kip/ft to about 70000 kip/ft in 1st floor. The storey stiffness at the level of set back exists is reduced to about 50000 kip/ft and there is a little increase in 6th floor. It can also be noticed that these is an increase in stiffness at 10th floor and 11th floor where the height of the storey changed. So, the structure is irregular, then the change in stiffness is not uniform. 4.10. Comparison of Structural Behaviour of Structural Member at Setback As the proposed building is vertical geometric irregular building, the discontinuity of the structural dimension makes the structure to suffer more from seismic effect at setback. As shear force depend on the load acting on the structure and if the structure is under seismic condition, the shear force will be larger. The analysis results of shear force and bending moment due to earthquake at exterior beams B96 at 70 Elevation B where the setback exists and beam B11 at Elevation C for four different locations are tabulated in Table 4.28 and Table 4.29. Table 4.28. Analysis Results for Beam Shear Forces at B96 and B11 Shear Force (kips) Storey Bago Nay Pyi Taw Taunggyi Yangon B96 B11 B96 B11 B96 B11 B96 B11 RF 5.87 4.80 4.40 3.60 3.25 2.65 2.03 1.66 14F 8.77 6.98 6.58 5.24 4.85 3.86 3.03 2.41 13F 11.85 8.62 8.89 6.47 6.55 4.77 4.10 2.98 12F 23.73 9.84 17.80 7.38 13.12 5.44 8.20 3.40 11F 50.78 11.02 38.08 8.26 28.07 6.09 17.55 3.81 10F 59.63 17.80 44.72 13.35 32.96 9.84 20.61 6.15 9F 54.80 20.75 41.10 15.56 30.29 11.47 18.94 7.17 8F 71.79 22.62 53.85 16.97 39.69 12.51 24.81 7.82 7F 60.16 32.13 45.12 24.10 33.26 17.76 20.79 11.10 6F 60.73 33.29 45.55 24.96 33.57 18.40 20.99 11.50 5F 102.50 31.87 76.87 23.90 56.66 17.62 35.42 11.01 4F 102.46 31.81 76.85 23.86 56.65 17.59 35.41 10.99 3F 107.63 33.28 80.72 24.96 59.54 18.41 37.19 11.50 2F 110.89 33.83 83.17 25.38 61.37 18.73 38.32 11.69 1F 102.97 32.98 77.22 24.74 56.99 18.26 35.58 11.40 GF 42.23 20.07 31.67 15.06 23.36 11.11 14.59 6.94 Table 4.29. Analysis Results for Beam Bending Moment at B96 and B11 Bending Moment (kip-ft) Storey Bago Nay Pyi Taw Taunggyi Yangon B96 B11 B96 B11 B96 B11 B96 B11 RF 47.27 35.90 35.45 26.93 26.13 19.85 16.33 12.41 14F 66.10 50.05 49.58 37.54 36.54 27.67 22.84 17.29 13F 89.13 61.89 66.85 46.42 49.27 34.21 30.80 21.39 12F 183.63 70.56 137.72 52.92 101.50 39.00 63.45 24.38 11F 415.43 77.25 311.58 57.94 229.64 42.70 143.56 26.70 10F 482.50 141.29 361.88 105.97 266.71 78.10 166.73 48.83 9F 429.10 164.77 321.82 123.58 237.19 91.08 148.28 56.94 8F 579.63 179.16 434.72 134.37 320.40 99.03 200.30 61.91 71 Table 4.29. Analysis Results for Beam Bending Moment at B96 and B11 Bending Moment (kip-ft) Storey Bago Nay Pyi Taw Taunggyi Yangon B96 B11 B96 B11 B96 B11 B96 B11 7F 468.54 276.82 351.41 207.62 258.99 153.02 161.91 95.66 6F 466.96 283.00 350.22 212.25 258.11 156.43 161.36 97.79 5F 818.41 273.02 613.81 204.77 452.39 150.92 282.81 94.35 4F 812.45 273.45 609.34 205.08 449.18 151.19 280.75 94.49 3F 841.28 280.50 630.96 210.37 465.37 155.16 290.71 96.93 2F 859.26 282.60 644.44 211.95 475.58 156.40 296.93 97.66 1F 794.90 276.33 596.17 207.25 439.96 152.94 274.69 95.49 GF 280.06 131.89 210.04 98.92 154.93 72.97 96.78 45.58 The forces and bending moments of structural members at elevation B and elevation C for four seismic locations are shown in Figure 4.11 through Figure 4.18. Figure 4.11. Shear Force Diagram of Elevation B and C at Bago Seismic Location 72 Figure 4.12. Bending Moment Diagram of Elevation B and C at Bago Seismic Location Figure 4.13. Shear Force Diagram of Elevation B and C at Nay Pyi Taw Seismic Location 73 Figure 4.14. Bending Moment Diagram of Elevation B and C at Nay Pyi Taw Seismic Location Figure 4.15. Shear Force Diagram of Elevation B and C Taunggyi Seismic Location 74 Figure 4.16. Bending Moment Diagram of Elevation B and C at Taunggyi Seismic Location Figure 4.17. Shear Force Diagram of Elevation B and C at Yangon Seismic Location 75 Figure 4.18. Bending Moment Diagram of Elevation B and C at Yangon Seismic Location From the above tables and figures, it is observed from the analysis is that the difference in shear forces and bending moments between adjacent storey is the largest at setback. In Figure 4.11, it can be observed that the shear forces at 5th floor and 6th floor in Elevation B at Bago seismic locations are 102.5 kips and 60.7 kips. Similarly, the shear forces at 5th floor and 6th floor in Elevation C are 31.9 kips and 33.3 kips. So, the difference between the two values at Elevation B is much larger than that of at Elevation C. Because of the vertical geometric irregularity, the shear forces are significant at the setback. From Figure 4.12, the bending moments at 5th floor and 6th floor in Elevation B at Bago are 818.4 kip-ft and 467 kip-ft, respectively. The bending moments of 5th and 6th floor in Elevation C are 273 kip-ft and 283 kip-ft. It can be seen that the differences in bending moments of two stories are largely different. The differences in shear forces and bending moments between two stories at other three locations: Nay Pyi Taw, Taunggyi and Yangon show the same manner as 76 Bago seismic location. But both the shear forces and bending moments near setback at Nay Pyi Taw, Taunggyi and Yangon are round about 25%, 45% and 65% smaller than that of at Bago seismic location. So, the larger the seismic parameters, the larger in the values of shear forces and bending moments. The differences in bending moment and shear forces of beams of adjacent storey at the setback are larger than other locations because the stiffness at that level are decreased due to setback. And the member at setback needs to be larger because of the discontinuity of the structure at that location. From the above comparison, the shear force and bending moment largely depend on the seismic parameter as the shear force and bending moment at larger seismic parameter are greater. CHAPTER 5 DISCUSSIONS, CONCLUSION AND RECOMMENDATIONS 5.1. Discussions The proposed building is 15-storied residential reinforced concrete vertical geometric irregular building at four different seismic locations: Bago, Nay Pyi Taw, Taunggyi and Yangon. In the first comparison, the structures at different seismic locations have the same structural plans and same column and beam sizes. In the second case, only the structural member sizes are changed to determine the optimum sizes and the structural plans remain the same as the previous buildings. The optimum structural member sizes are considered with respect to different seismic locations and the optimized structures are compared with the previous structure of the same location. The column sizes reduced two inches every after four levels. The horizontal dimension of the structure reduced from 134 m to 94 m at 6th floor and the higher level is more than 130% smaller than the adjacent lower level. The shear wall thickness and the slab thickness are also the same at respective floors. Concrete structural members are designed with material properties fc′ = 4000 psi and fy = 60000 psi. The stability of the superstructure of all buildings is checked with response spectrum analysis as per MNBC 2020. According to MNBC 2020, the storey drift, p-Δ effect, overturning moment, torsional irregularity, soft storey checking and sliding are carried out. All the checked results are satisfied with the limitation for all the buildings of every location at consideration, so the buildings are stable. Since Bago has the largest seismic parameters: Ss and S1, the compared results shows that the values of storey drift, storey shear, storey displacement, overturning moment are superior to the buildings of the same sizes at other locations. The seismic parameters Ss and S1 at Bago are 1.6 times and 1.3 times of those of at Nay Pyi Taw, respectively. And again, Ss and S1 at Nay Pyi Taw are 1.8 times and 2.2 times of Taunggyi which are 1.1 times and 2 times of Yangon. The proposed structure is vertical geometric irregular structure, so the structural 78 behaviours of the structural members at setback shows many differences from other members. Because of the irregularity, the members at setback need to be larger than other members to be stabilized the structure. 5.2. Conclusion The following conclusions are made based on the comparison results of the vertical geometric irregular structures at different locations. 1. Results from the structural stability checking of the buildings in dynamic analysis show that the proposed structures are stable at all locations at consideration. 2. The results from this study show that the storey drift, storey shears, storey displacements of the vertical geometric irregular structure at higher seismic location is larger than that of the structure at lower seismic location with the same structural frame. 3. The maximum storey shear, the storey displacement, the shear forces and the bending moments at setback at Bago are also about 1.8, 1.3 and 2.9 times larger than that of Taunggyi, Nay Pyi Taw and Yangon, respectively. 4. Both the shear forces and bending moments near setback at Nay Pyi Taw, Taunggyi and Yangon are round about 25%, 45% and 65% smaller than that of at Bago seismic location. 5. At setback, the shear force and the bending moment of the beams are large and the beam sizes are larger than other beams because of a sudden change of the structure at that location of setback. So, the beams at setback suffer from the effect of seismic more than other beams. According to above results, if the buildings are of the same size, the seismic parameters largely impact the behaviour of the structure and it is obvious that the seismic location is largely influenced on the structural design. If the structural member sizes are reduced at the locations of smaller seismic parameters, the time period will increase as the weight of the structures reduced. So, the stiffness of the structure needs to be increased to reduce the time period. 5.3. Recommendations In this study, the fifteen-storey vertical geometric irregular buildings at four different locations are analyzed using dynamic response spectrum anlaysis. Both the 79 intermediate and special moment resisting frame with seismic categories C and E are included in the consideration. According to this study, further researches should be carried out as follows: 1. Vertical geometric irregular structure should be considered at other different locations of seismic design category F. 2. Vertical geometric irregular structure should be designed and analyzed with time history analysis. 3. Other types of irregularity should be considered and analyse with different storey height of building. 4. The irregular structures with different slab systems should be investigated. REFERENCES [1] ACI Committee, 2008. Building Code Requirements for Structural Concrete and Commentary, U.S.A. [2] Anonymous, 1997. Uniform Building Code, Volume 2, Structural Engineering Design Provision, U.S.A. [3] Anonymous, 1999. Seismic Design Manual: Volume I Code Application Examples, Structural Engineers Association of California, California. [4] Anonymous, ASCE 7-05. 2005. Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineer, U.S.A. [5] Myanmar Engineering Council, 2020, Myanmar National Building Code 2020 (MNBC 2020). “Part 3 Structural Design”, Myanmar Engineering Council, Myanmar. [6] Nilson, A.H., 2009. Design of Concrete Structure. 14th ed. New York: Mc-Graw Hill Inc. [7] Paulay, T. 1992. Seismic Design of Reinforced Concrete and Masonry Buildings. New York. [8] Sandelin. C. 2013, The Stabilization of High-Rise Buildings. An Evaluation of the Tubed Mega Frame Concept. Uppsala Universtiy. [9] Taranath, B.S. 1988. Structural Analysis and Design of Tall Buildings. New York, USA. [10] U Nyi Hla Nge. 2010. Reinforced Concrete Design. 1st ed. Yangon: The Engineering Publishing House. (2010) . APPENDICES APPENDIX A TABLES FROM MNBC 2020 Table A.1. 0.2s (Ss) and 1.0s (S1) Special Maximum Considered Earthquake Ground Motion Accelerations at 2% Probability in 50 Years with 5% Critical Damping, Site Class B Sr City Latitude Longitude SS S1 1 Bagan 21.167 94.850 1.00 0.50 2 Bago 17.333 96.483 2.40 1.20 3 Bamaw 24.267 97.200 0.80 0.50 4 Coco Islands 14.117 93.367 0.80 0.30 5 Dawei 14.100 98.217 1.20 0.80 6 Hakha 22.650 93.617 1.00 0.70 7 Hpa-An (Pa-An) 16.750 97.667 0.20 0.20 8 Kengtung 21.300 99.617 0.70 0.20 9 Kyaukpyu 19.417 93.550 0.90 0.40 10 Labutta 16.147 94.761 0.70 0.50 11 Lashio 22.933 97.750 0.70 0.20 12 Loikaw 19.683 97.217 0.90 0.40 13 Magwe 20.150 94.167 1.00 0.60 14 Mandalay 21.933 96.100 1.20 0.70 15 Mawlamyine 16.500 97.617 0.30 0.20 16 Meiktila 20.833 95.833 0.80 0.50 17 Monywa 22.083 95.000 0.90 0.40 18 Myeik (Mergui) 12.433 98.600 0.60 0.30 19 Myitkyina 25.367 97.400 0.90 0.90 20 Naypyitaw 19.750 96.100 1.50 0.90 21 Pakokku 21.333 95.083 1.00 0.40 22 Pathein (Bassein) 16.783 94.733 0.70 0.30 83 Table A.1. 0.2s (Ss) and 1.0s (S1) Special Maximum Considered Earthquake Ground Motion Accelerations at 2% Probability in 50 Years with 5% Critical Damping, Site Class B (Continued) Sr City Latitude Longitude SS S1 23 Putao 27.333 97.417 0.90 1.00 24 Pyay 18.800 95.217 0.80 0.30 25 Pyinmana 19.733 96.217 1.50 0.90 26 Sagaing 21.867 95.983 1.80 1.20 27 Shwebo 22.567 95.700 0.70 0.40 28 Sittwe 20.133 92.883 0.80 0.70 29 Taungoo 18.933 96.433 1.50 0.90 30 Taunggyi 20.783 97.033 0.80 0.40 31 Thandwe (Sandoway) 18.467 94.350 0.60 0.20 32 Yangon 16.767 96.167 0.70 0.20 Note: Long-period transition period TL is to be taken as 6 sec. Table A.2. Basic Wind Speed (3 sec Gust Wind Speed in mph) Sr. No. 1 Bago City Latitude Longitude BasicWindSpeed(mph) 17.33 96.48 80 2 Bamaw 24.27 97.20 70 3 Bogalay 16.30 95.40 100 4 Chauk 20.90 94.83 70 5 Dawei 14.10 98.22 90 6 Falam 22.91 93.68 70 7 Hakha 22.65 93.62 90 8 Henzada 17.65 95.46 90 9 Homalin 24.87 94.92 50 10 Hpa-An 16.75 97.67 70 11 Kale 23.18 94.05 70 12 Kawthaung 10.00 98.55 90 13 Kengtung 21.30 99.62 70 14 15 Kyaukpyu Lashio 19.42 22.93 93.55 97.75 130 70 84 Table A.2. Basic Wind Speed (3 sec Gust Wind Speed in mph) (Continued) Sr. City No. Latitude Longitude BasicWindSpeed(mph) 16 Loikaw 19.68 97.22 70 17 Magwe 20.15 94.17 70 18 Mandalay 21.93 96.10 80 19 Mawlamyine 16.50 97.62 90 20 Meiktila 20.83 95.83 70 21 Monywa 22.08 95.00 70 22 Muse 23.98 97.90 70 23 Myeik 12.43 98.60 90 24 Myitkyina 25.37 97.40 70 25 Nansam 20.90 97.71 70 26 Naypyitaw 19.75 96.10 70 27 Pakokku 21.33 95.08 70 28 Pathein 16.78 94.73 100 29 Putao 27.33 97.42 70 30 Pyay 18.80 95.22 70 31 Sittwe 20.13 92.88 130 32 Taunggyi 20.78 97.03 70 33 Thandwe 18.47 94.35 130 34 Yangon 16.77 96.17 100 35 Ye 15.26 97.85 90 36 Yenangyaung 20.46 94.87 70 Note: For cities not included in the table, wind speed of the nearest city in the list shall be used. APPENDIX B STABILITY CHECKINGS Table B.1. Checking for Storey Drift in X-direction for Nay Pyi Taw Cd δxe I Storey Heigh, h Cd Level (ft) Storey Drift Ratio δxe (in) δx = Allowable Remark Δa RF-1 8 5.5 0.000814 0.078 0.42979 1.92 OK RF 10 5.5 0.001334 0.160 0.88044 2.4 OK 14F 10 5.5 0.001573 0.189 1.03818 2.4 OK 13F 10 5.5 0.00177 0.212 1.1682 2.4 OK 12F 10 5.5 0.001855 0.223 1.2243 2.4 OK 11F 10 5.5 0.001891 0.227 1.24806 2.4 OK 10F 12 5.5 0.002101 0.303 1.66399 2.88 OK 9F 12 5.5 0.002255 0.325 1.78596 2.88 OK 8F 12 5.5 0.002253 0.324 1.78438 2.88 OK 7F 12 5.5 0.002196 0.316 1.73923 2.88 OK 6F 12 5.5 0.002201 0.317 1.74319 2.88 OK 5F 14 5.5 0.002225 0.374 2.0559 3.36 OK 4F 14 5.5 0.002289 0.385 2.11504 3.36 OK 3F 14 5.5 0.002222 0.373 2.05313 3.36 OK 2F 14 5.5 0.002131 0.358 1.96904 3.36 OK 1F 14 5.5 0.001913 0.321 1.76761 3.36 OK GF 10 5.5 0.001192 0.143 0.78672 2.4 OK Table B.2. Checking for Storey Drift in Y-direction for Nay Pyi Taw Cd δxe Allowable Remark Δa I Storey Height, Level h (ft) Cd Storey Drift Ratio δxe (in) δx = RF-1 8 5.5 0.000785 0.07536 0.41448 1.92 OK RF 10 5.5 0.001166 0.13992 0.76956 2.4 OK 14F 10 5.5 0.001379 0.16548 0.91014 2.4 OK 13F 10 5.5 0.001564 0.18768 1.03224 2.4 OK 12F 10 5.5 0.001654 0.19848 1.09164 2.4 OK 86 Table B.2. Checking for Storey Drift in Y-direction for Nay Pyi Taw (Continued) Cd δxe Allowable Remark Δa I Storey Height, Level h (ft) Cd Storey Drift Ratio δxe (in) δx = 11F 10 5.5 0.001705 0.2046 1.1253 2.4 OK 10F 12 5.5 0.00192 0.27648 1.52064 2.88 OK 9F 12 5.5 0.002085 0.30024 1.65132 2.88 OK 8F 12 5.5 0.002126 0.306144 1.68379 2.88 OK 7F 12 5.5 0.002082 0.299808 1.64894 2.88 OK 6F 12 5.5 0.002038 0.293472 1.6141 2.88 OK 5F 14 5.5 0.002055 0.34524 1.89882 3.36 OK 4F 14 5.5 0.002128 0.357504 1.96627 3.36 OK 3F 14 5.5 0.002133 0.358344 1.97089 3.36 OK 2F 14 5.5 0.002126 0.357168 1.96442 3.36 OK 1F 14 5.5 0.001961 0.329448 1.81196 3.36 OK GF 10 5.5 0.001242 0.14904 0.81972 2.4 OK Table B.3. Checking for Storey Drift in X-direction for Taunggyi Storey Heigh, h Cd Level (ft) Storey Drift Ratio δxe (in) RF-1 8 4.5 0.000629 0.060384 Cd δxe I 0.27173 RF 10 4.5 0.00102 0.1224 14F 10 4.5 0.001197 13F 10 4.5 12F 10 11F δx = Allowable Remark Δa 1.92 OK 0.5508 2.4 OK 0.14364 0.64638 2.4 OK 0.001335 0.1602 0.7209 2.4 OK 4.5 0.00138 0.1656 0.7452 2.4 OK 10 4.5 0.001387 0.16644 0.74898 2.4 OK 10F 12 4.5 0.001521 0.219024 0.98561 2.88 OK 9F 12 4.5 0.001614 0.232416 1.04587 2.88 OK 8F 12 4.5 0.001595 0.22968 1.03356 2.88 OK 7F 12 4.5 0.00154 0.22176 0.99792 2.88 OK 6F 12 4.5 0.001534 0.220896 0.99403 2.88 OK 5F 14 4.5 0.001548 0.260064 1.17029 3.36 OK 4F 14 4.5 0.001598 0.268464 1.20809 3.36 OK 3F 14 4.5 0.001561 0.262248 1.18012 3.36 OK 2F 14 4.5 0.001509 0.253512 1.1408 3.36 OK 1F 14 4.5 0.001366 0.229488 1.0327 3.36 OK GF 10 4.5 0.000855 0.1026 0.4617 2.4 OK 87 Table B.4. Checking for Storey Drift in Y-direction for Taunggyi Storey Heigh, h Cd Level (ft) Storey Drift Ratio δxe (in) RF-1 8 4.5 0.000627 0.060192 Cd δxe I 0.27086 RF 10 4.5 0.000916 0.10992 14F 10 4.5 0.00108 13F 10 4.5 12F 10 11F δx = Allowable Remark Δa 1.92 OK 0.49464 2.4 OK 0.1296 0.5832 2.4 OK 0.001214 0.14568 0.65556 2.4 OK 4.5 0.001267 0.15204 0.68418 2.4 OK 10 4.5 0.001288 0.15456 0.69552 2.4 OK 10F 12 4.5 0.001432 0.206208 0.92794 2.88 OK 9F 12 4.5 0.001535 0.22104 0.99468 2.88 OK 8F 12 4.5 0.001545 0.22248 1.00116 2.88 OK 7F 12 4.5 0.001497 0.215568 0.97006 2.88 OK 6F 12 4.5 0.001454 0.209376 0.94219 2.88 OK 5F 14 4.5 0.001463 0.245784 1.10603 3.36 OK 4F 14 4.5 0.00152 0.25536 1.14912 3.36 OK 3F 14 4.5 0.001535 0.25788 1.16046 3.36 OK 2F 14 4.5 0.001545 0.25956 1.16802 3.36 OK 1F 14 4.5 0.001436 0.241248 1.08562 3.36 OK GF 10 4.5 0.000913 0.10956 0.49302 2.4 OK Table B.5. Checking for Storey Drift in X-direction for Yangon Storey Heigh, h Cd Level (ft) Storey Drift Ratio δxe (in) RF-1 8 4.5 0.000421 0.040416 Cd δxe I 0.18187 RF 10 4.5 0.000666 0.07992 14F 10 4.5 0.000774 13F 10 4.5 12F 10 11F δx = Allowable Remark Δa 1.92 OK 0.35964 2.4 OK 0.09288 0.41796 2.4 OK 0.000849 0.10188 0.45846 2.4 OK 4.5 0.000862 0.10344 0.46548 2.4 OK 10 4.5 0.000855 0.1026 0.4617 2.4 OK 10F 12 4.5 0.000933 0.134352 0.60458 2.88 OK 9F 12 4.5 0.000991 0.142704 0.64217 2.88 OK 8F 12 4.5 0.000983 0.141552 0.63698 2.88 OK 7F 12 4.5 0.000952 0.137088 0.6169 2.88 OK 6F 12 4.5 0.000948 0.136512 0.6143 2.88 OK 5F 14 4.5 0.000954 0.160272 0.72122 3.36 OK 88 Table B.5. Checking for Storey Drift in X-direction for Yangon (Continued) Storey Heigh, h Cd Level (ft) 4F 14 4.5 Storey Drift Ratio 0.00098 0.16464 Cd δxe I 0.74088 δxe (in) Allowable Remark Δa 3.36 OK δx = 3F 14 4.5 0.000955 0.16044 0.72198 3.36 OK 2F 14 4.5 0.000926 0.155568 0.70006 3.36 OK 1F 14 4.5 0.000844 0.141792 0.63806 3.36 OK GF 10 4.5 0.000532 0.06384 0.28728 2.4 OK Table B.6. Checking for Storey Drift in Y-direction for Yangon RF-1 8 4.5 0.00042 0.04032 Cd δxe I 0.18144 RF 10 4.5 0.000596 0.07152 14F 10 4.5 0.000697 13F 10 4.5 12F 10 11F Storey Heigh, h Cd Level (ft) Storey Drift Ratio δxe (in) δx = Allowable Remark Δa 1.92 OK 0.32184 2.4 OK 0.08364 0.37638 2.4 OK 0.000771 0.09252 0.41634 2.4 OK 4.5 0.000792 0.09504 0.42768 2.4 OK 10 4.5 0.000795 0.0954 0.4293 2.4 OK 10F 12 4.5 0.000879 0.126576 0.56959 2.88 OK 9F 12 4.5 0.000942 0.135648 0.61042 2.88 OK 8F 12 4.5 0.000951 0.136944 0.61625 2.88 OK 7F 12 4.5 0.000924 0.133056 0.59875 2.88 OK 6F 12 4.5 0.000898 0.129312 0.5819 2.88 OK 5F 14 4.5 0.000901 0.151368 0.68116 3.36 OK 4F 14 4.5 0.000932 0.156576 0.70459 3.36 OK 3F 14 4.5 0.000938 0.157584 0.70913 3.36 OK 2F 14 4.5 0.000946 0.158928 0.71518 3.36 OK 1F 14 4.5 0.000885 0.14868 0.66906 3.36 OK GF 10 4.5 0.000566 0.06792 0.30564 2.4 OK Table B.7. Checking for P-Δ Effect in X-direction for Nay Pyi Taw RF-1 223.4 33.6 Primary Moment Δ (in) VxhsxCd (kipft) 5.5 1480.028 0.078144 RF 2256.2 248.7 5.5 13678.06 0.16008 30.0983 0.0022 14F 2231.6 486.0 5.5 26732.37 0.18876 35.1028 0.00131 Storey P (kips) Vx (kip) Cd Level secondary Moment PΔ (kipft) 1.45495 Stability Coefficient (θ) 0.00098 89 Table B.7. Checking for P-Δ Effect in X-direction for Nay Pyi Taw (Continued) Storey P (kips) Vx (kip) Cd Level Δ (in) 13F 2231.6 677.5 Primary Moment VxhsxCd (kipft) 5.5 37264.81 0.2124 secondary Moment PΔ (kipft) 39.4991 Stability Coefficient (θ) 0.00106 12F 2265.9 839.7 5.5 46181.52 0.2226 42.0323 0.00091 11F 2366.9 984.4 5.5 54142.77 0.22692 44.7584 0.00083 10F 2502.5 1119.9 5.5 73914.06 0.302544 63.0932 0.00085 9F 2468.8 1228.9 5.5 81109.58 0.32472 66.8048 0.00082 8F 2482.9 1322.9 5.5 87311.2 0.324432 67.1266 0.00077 7F 2562.2 1411.4 5.5 93154.38 0.316224 67.5185 0.00072 6F 2554.1 1498.3 5.5 98884.5 0.316944 67.4576 0.00068 5F 3424.9 1614.2 5.5 124291.9 0.3738 106.686 0.00086 4F 3749.9 1731.1 5.5 133292.1 0.384552 120.17 0.0009 3F 3803.8 1839.8 5.5 141661.9 0.373296 118.33 0.00084 2F 3806.0 1933.5 5.5 148880.9 0.358008 113.547 0.00076 1F 3807.0 2002.1 5.5 154160.3 0.321384 101.958 0.00066 GF 4024.0 2028.0 5.5 111540.9 0.14304 47.9662 0.00043 Table B.8. Checking for P-Δ Effect in Y-direction for Nay Pyi Taw Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) 5.5 1389.9 0.07536 1.40312 0.00101 2256.25 237.125 5.5 13041.9 0.13992 26.3078 0.00202 14F 2231.59 470.097 5.5 25855.3 0.16548 30.7736 0.00119 13F 2231.59 660.857 5.5 36347.1 0.18768 34.902 0.00096 12F 2265.89 824.233 5.5 45332.8 0.19848 37.4778 0.00083 11F 2366.92 972.736 5.5 53500.5 0.2046 40.356 0.00075 10F 2502.51 1112.46 5.5 73422.6 0.27648 57.6578 0.00079 9F 2468.77 1224.56 5.5 80820.8 0.30024 61.7685 0.00076 8F 2482.86 1321.53 5.5 87221.0 0.30614 63.3427 0.00073 7F 2562.18 1411.78 5.5 93177.4 0.29981 64.0135 0.00069 6F 2554.05 1498.1 5.5 98874.3 0.29347 62.4619 0.00063 5F 3424.91 1613.54 5.5 124242.2 0.34524 98.5347 0.00079 4F 3749.92 1730.54 5.5 133251.2 0.3575 111.718 0.00084 3F 3803.83 1839.27 5.5 141623.6 0.35834 113.59 0.0008 Storey P (kips) Vy (kip) Cd Level RF-1 223.426 31.588 RF 90 Table B.8. Checking for P-Δ Effect in Y-direction for Nay Pyi Taw (Continued) 2F Primary Moment Δ (in) VxhsxCd (kipft) 3805.97 1934.23 5.5 148935.3 0.35717 secondary Moment PΔ (kipft) 113.281 Stability Coefficient (θ) 0.00076 1F 3806.97 2002.84 5.5 154218.7 0.32945 104.517 0.00068 GF 4024.01 2027.98 5.5 111538.9 0.14904 49.9782 0.00045 Storey P (kips) Vy (kip) Cd Level Table B.9. Checking for P-Δ Effect in X-direction for Taunggyi Storey P (kips) Vx (kip) Cd Level Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) RF-1 223.4 28.4 4.5 1023.408 0.060384 1.12428 0.0011 RF 2256.2 203.0 4.5 9133.02 0.1224 23.0137 0.00252 14F 2231.6 385.5 4.5 17348.36 0.14364 26.7121 0.00154 13F 2231.6 524.7 4.5 23612.9 0.1602 29.7917 0.00126 12F 2265.9 636.8 4.5 28655.96 0.1656 31.2693 0.00109 11F 2366.9 732.3 4.5 32952.47 0.16644 32.8292 0.001 10F 2502.5 819.1 4.5 44232.48 0.219024 45.6758 0.00103 9F 2468.8 886.1 4.5 47851.45 0.232416 47.8151 0.001 8F 2482.9 941.6 4.5 50846.45 0.22968 47.5219 0.00093 7F 2562.2 994.3 4.5 53691.28 0.22176 47.349 0.00088 6F 2554.1 1049.0 4.5 56644 0.220896 47.015 0.00083 5F 3424.9 1127.7 4.5 71045.67 0.260064 74.2246 0.00104 4F 3749.9 1213.3 4.5 76440.67 0.268464 83.8931 0.0011 3F 3803.8 1298.6 4.5 81814.64 0.262248 83.1289 0.00102 2F 3805.7 1377.0 4.5 86751.63 0.253512 80.3986 0.00093 1F 3806.7 1438.8 4.5 90644.84 0.229488 72.7988 0.0008 GF 4024.0 1463.5 4.5 65859.08 0.1026 34.4053 0.00052 Table B.10. Checking for P-Δ Effect in Y-direction for Taunggyi Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) 4.5 972.18 0.06019 1.1207 0.00115 2256.25 198.302 4.5 8923.59 0.10992 20.6672 0.00232 14F 2231.59 384.378 4.5 17297 0.1296 24.1011 0.00139 Storey P (kips) Vy (kip) Cd Level RF-1 223.426 27.005 RF 91 Table B.10. Checking for P-Δ Effect in Y-direction for Taunggyi (Continued) Storey P (kips) Vy (kip) Cd Level Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) 13F 2231.59 528.484 4.5 23781.8 0.14568 27.0915 0.00114 12F 2265.89 645.314 4.5 29039.1 0.15204 28.7088 0.00099 11F 2366.92 747.051 4.5 33617.3 0.15456 30.4859 0.00091 10F 2502.51 839.352 4.5 45325 0.20621 43.0031 0.00095 9F 2468.77 908.677 4.5 49068.6 0.22104 45.4747 0.00093 8F 2482.86 965.937 4.5 52160.6 0.22248 46.0322 0.00088 7F 2562.18 1019.33 4.5 55043.7 0.21557 46.027 0.00084 6F 2554.05 1072.77 4.5 57929.5 0.20938 44.5631 0.00077 5F 3424.91 1152.06 4.5 72580 0.24578 70.149 0.00097 4F 3749.92 1240.51 4.5 78152.3 0.25536 79.7982 0.00102 3F 3803.83 1328.43 4.5 83691.3 0.25788 81.7443 0.00098 2F 3805.67 1410.83 4.5 88882.3 0.25956 82.3166 0.00093 1F 3806.67 1474.38 4.5 92885.8 0.24125 76.5293 0.00082 GF 4024.01 1498.54 4.5 67434.2 0.10956 36.7392 0.00054 Table B.11. Checking for P-Δ Effect in X-direction for Yangon Storey P (kips) Vx (kip) Cd Level Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) RF-1 223.4 21.7 4.5 783 0.0404 0.7525 0.0010 RF 2256.2 147.0 4.5 6616 0.0799 15.0266 0.0023 14F 2231.6 265.0 4.5 11926 0.0929 17.2725 0.0014 13F 2231.6 344.8 4.5 15515 0.1019 18.9462 0.0012 12F 2265.9 404.6 4.5 18209 0.1034 19.5320 0.0011 11F 2366.9 455.9 4.5 20515 0.1026 20.2371 0.0010 10F 2502.5 506.5 4.5 27351 0.1344 28.0181 0.0010 9F 2468.8 549.1 4.5 29650 0.1427 29.3586 0.0010 8F 2482.9 586.2 4.5 31653 0.1416 29.2878 0.0009 7F 2562.2 621.4 4.5 33556 0.1371 29.2703 0.0009 6F 2554.1 655.9 4.5 35416 0.1365 29.0549 0.0008 5F 3424.9 701.2 4.5 44174 0.1603 45.7431 0.0010 4F 3749.9 747.9 4.5 47119 0.1646 51.4489 0.0011 3F 3803.8 796.4 4.5 50173 0.1604 50.8572 0.0010 92 Table B.11. Checking for P-Δ Effect in X-direction for Yangon (Continued) Storey P (kips) Vx (kip) Cd Level Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) 2F 3806.0 847.5 4.5 53391 0.1556 49.3406 0.0009 1F 3807.0 896.2 4.5 56459 0.1418 44.9832 0.0008 GF 4024.0 918.0 4.5 41309 0.0638 21.4077 0.0005 Table B.12. Checking for P-Δ Effect in Y-direction for Yangon Storey P (kips) Vy (kip) Cd Level RF-1 223.426 Primary Moment VxhsxCd (kipft) Δ (in) secondary Moment PΔ (kipft) Stability Coefficient (θ) 20.2 4.5 727.524 0.04032 0.75071 0.00103 2256.25 141.7 4.5 6376.59 0.07152 13.4472 0.00211 14F 2231.59 262.6 4.5 11819.2 0.08364 15.5541 0.00132 13F 2231.59 346.4 4.5 15585.8 0.09252 17.2055 0.0011 12F 2265.89 409.4 4.5 18422.3 0.09504 17.9459 0.00097 11F 2366.92 465.2 4.5 20934.2 0.0954 18.817 0.0009 10F 2502.51 519.1 4.5 28033.4 0.12658 26.3965 0.00094 9F 2468.77 561.7 4.5 30331.3 0.13565 27.9069 0.00092 8F 2482.86 599.2 4.5 32357.2 0.13694 28.3344 0.00088 7F 2562.18 634.9 4.5 34283.1 0.13306 28.4094 0.00083 6F 2554.05 668.3 4.5 36085.7 0.12931 27.5225 0.00076 5F 3424.91 714.9 4.5 45041 0.15137 43.2018 0.00096 4F 3749.92 764.7 4.5 48173.5 0.15658 48.9289 0.00102 3F 3803.83 813.9 4.5 51276.3 0.15758 49.9519 0.00097 2F 3805.97 866.7 4.5 54599 0.15893 50.4063 0.00092 1F 3806.97 914.8 4.5 57631.1 0.14868 47.1684 0.00082 GF 4024.01 934.8 4.5 42068.1 0.06792 22.7759 0.00054 RF Table B.13. Checking for Overturning Moment in X-direction for Nay Pyi Taw Resisting Storey Total D.L Moment C.M.M Level (kips) 0.9×P×C.M.M (kip-ft) RF-1 RF 195.6 1675.8 67.1 67.0 11814.5 101057.7 Vx Additional Overturning Moment Moment (kip-ft) (kip-ft) F.S 33.6 248.7 269.099 2744.89 22.0 19.3 538.195 5231.81 93 Table B.13. Checking for Overturning Moment in X-direction for Nay Pyi Taw (Continued) Resisting Storey Total D.L Moment C.M.M Level (kips) 0.9×P×C.M.M (kip-ft) 14F 3521.9 67.0 212475.1 13F 5368.1 67.0 323851.8 12F 7248.5 67.0 437294.0 11F 9230.0 67.0 556705.9 10F 11346.5 67.0 684193.3 9F 13346.1 67.0 804767.9 8F 15359.7 67.0 926192.3 7F 17452.7 67.0 1052399.6 6F 19537.6 67.0 1178116.8 5F 22332.7 67.0 1346663.4 4F 25098.9 66.9 1511241.2 3F 27917.9 66.9 1680998.0 2F 30739.0 66.9 1850895.9 1F 33561.2 66.9 2020826.5 GF 36269.2 66.8 2180923.6 Vx 486.0 677.5 839.7 984.4 1119.9 1228.9 1322.9 1411.4 1498.3 1614.2 1731.1 1839.8 1933.5 2002.1 2028.0 Additional Overturning Moment Moment (kip-ft) (kip-ft) F.S 7572.07 14256.9 22470.7 32016.3 44952 59069 74136.3 90018.6 106655 127120 148765 171631 195681 220777 239196 17.1 15.4 14.2 13.3 11.7 10.9 10.3 9.8 9.5 9.0 8.7 8.5 8.3 8.1 8.4 12432.5 21032.3 30867.3 41860.5 58390.9 73816.2 90011.1 106956 124634 149718 173000 197388 222750 248806 259476 Table B.14. Checking for Overturning Moment in Y-direction for Nay Pyi Taw Resisting Storey Total D.L Moment C.M.M Level (kips) 0.9×P×C.M.M (kip-ft) RF-1 195.6 50.2 8831.8 Vy Additional Overturning Moment Moment (kip-ft) (kip-ft) F.S 31.6 252.7041 505.4081 17.5 RF 1675.8 50.1 75609.9 237.1 2614.621 4985.871 15.2 14F 3521.9 50.1 158819.5 470.1 7291.616 11992.59 13.2 13F 5368.1 50.1 241988.2 660.9 13832.62 20441.19 11.8 12F 7248.5 50.1 326746.8 824.2 21924.93 30167.26 10.8 11F 9230.0 50.1 416036.5 972.7 31391.72 41119.08 10.1 10F 11346.5 50.1 511368.1 1112.5 44300.59 57650.15 8.9 9F 13346.1 50.1 601805.4 1224.6 58448.45 73143.13 8.2 8F 15359.7 50.1 692596.9 1321.5 73596.52 89454.89 7.7 7F 17452.7 50.1 786907.4 1411.8 89599.2 106540.5 7.4 6F 19537.6 50.1 880936.0 1498.1 106373.4 124350.6 7.1 5F 22332.7 50.1 1006500.2 1613.5 127010.2 149599.7 6.7 94 Table B.14. Checking for Overturning Moment in Y-direction for Nay Pyi Taw (Continued) Storey Total D.L C.M.M Level (kips) 4F 3F 2F 1F GF 25098.9 27917.9 30739.0 33561.2 36269.2 50.6 50.6 50.6 50.6 50.2 Resisting Moment (kip-ft) 1143323.2 1271573.5 1399882.5 1528451.0 1639999.1 Vy 1730.5 1839.3 1934.2 2002.8 2028.0 Additional Overturning Moment Moment (kip-ft) (kip-ft) 148824.6 173052.1 171850.1 197599.8 196049.8 223128.9 221283.3 249323 239786.6 260066.4 F.S 6.6 6.4 6.3 6.1 6.3 Table B.15. Checking for Overturning Moment in X-direction for Taunggyi Total D.L C.M.M (kips) RF-1 195.6 67.1 RF 1675.8 67.0 14F 3521.9 67.0 13F 5368.1 67.0 12F 7248.5 67.0 11F 9230.0 67.0 10F 11346.5 67.0 9F 13346.1 67.0 8F 15359.7 67.0 7F 17452.7 67.0 6F 19537.6 67.0 5F 22332.7 67.0 4F 25098.9 66.9 3F 27917.9 66.9 2F 30738.7 66.9 1F 33560.6 66.9 GF 36268.6 66.8 Storey Level Resisting Moment (kip-ft) 11814.5 101057.7 212475.1 323851.8 437294.0 556705.9 684193.3 804767.9 926192.3 1052399.6 1178116.8 1346663.4 1511241.2 1680998.0 1850877.8 2020790.4 2180887.6 Vx 28.4 203.0 385.5 524.7 636.8 732.3 819.1 886.1 941.6 994.3 1049.0 1127.7 1213.3 1298.6 1377.0 1438.8 1463.5 Additional Overturning Moment Moment F.S (kip-ft) (kip-ft) 227.424 454.848 26.0 2246.93 4276.49 23.6 6068.82 9924.01 21.4 11222.1 16469.5 19.7 17401.4 23769.4 18.4 24419.7 31742.4 17.5 33733.9 43563.3 15.7 43722.1 54355.7 14.8 54204.2 65503.4 14.1 65077.8 77009.2 13.7 76322.1 88909.7 13.3 89978.7 105767 12.7 104371 121358 12.5 119638 137819 12.2 135855 155133 11.9 153004 173148 11.7 165736 180371 12.1 Table B.16. Checking for Overturning Moment in Y-direction for Taunggyi Storey Level Total D.L C.M.M (kips) Resisting Moment (kip-ft) Vy RF-1 195.6 8831.788 27.005 50.2 Additional Overturning Moment Moment (kip-ft) (kip-ft) 216.0 432.1 F.S 20.4 95 Table B.16. Checking for Overturning Moment in Y-direction for Taunggyi (Continued) Storey Level RF 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F GF Total D.L C.M.M (kips) Resisting Moment (kip-ft) Vy 1675.8 3521.9 5368.1 7248.5 9230.0 11346.5 13346.1 15359.7 17452.7 19537.6 22332.7 25098.9 27917.9 30738.7 33560.6 36268.6 75609.92 158819.5 241988.2 326746.8 416036.5 511368.1 601805.4 692596.9 786907.4 880936 1006500 1143323 1271573 1399872 1528427 1639972 198.302 384.378 528.484 645.314 747.051 839.352 908.677 965.937 1019.33 1072.77 1152.06 1240.51 1328.43 1410.83 1474.38 1498.54 50.1 50.1 50.1 50.1 50.1 50.1 50.1 50.1 50.1 50.1 50.1 50.6 50.6 50.6 50.6 50.2 Additional Overturning Moment Moment (kip-ft) (kip-ft) F.S 2191.1 6013.0 11232.1 17533.8 24735.7 34347.9 44680.1 55527.8 66774.0 78376.5 92421.5 107185.5 122824.1 139431.1 156998.9 170040.9 18.1 16.1 14.7 13.6 12.9 11.5 10.8 10.3 10.0 9.7 9.3 9.2 9.0 8.8 8.6 8.9 4174.1 9856.7 16516.9 23986.9 32206.2 44420.1 55584.2 67119.1 79005.9 91249.7 108550.4 124552.7 141422.2 159182.7 177640.1 185026.3 Table B.17. Checking for Overturning Moment in X-direction for Yangon Storey Level Total D.L C.M.M (kips) Resisting Moment (kip-ft) Vx Additional Overturning Moment Moment (kip-ft) (kip-ft) RF-1 195.6 67.1 11814.52 21.745 174.0 347.9 34.0 RF 1675.8 67.0 101057.7 147.023 1636.2 3106.5 32.5 14F 3521.9 67.0 212475.1 265.033 4255.7 6906.0 30.8 13F 5368.1 67.0 323851.8 344.77 7606.4 11054.1 29.3 12F 7248.5 67.0 437294 404.634 11446.1 15492.5 28.2 11F 9230.0 67.0 556705.9 455.896 15663.1 20222.0 27.5 10F 11346.5 67.0 684193.3 506.493 21163.5 27241.4 25.1 9F 13346.1 67.0 804767.9 549.07 27061.1 33649.9 23.9 8F 15359.7 67.0 926192.3 586.158 33295.6 40329.5 23.0 7F 17452.7 67.0 1052400 621.402 39829.2 47286.0 22.3 6F 19537.6 67.0 1178117 655.861 46653.1 54523.4 21.6 5F 22332.7 67.0 1346663 701.18 54991.7 64808.3 20.8 4F 25098.9 66.9 1511241 747.928 63783.6 74254.6 20.4 F.S 96 Table B.17. Checking for Overturning Moment in X-direction for Yangon (Continued) Total D.L C.M.M (kips) Resisting Moment (kip-ft) Vx 3F 27917.9 66.9 1680998 2F 30739.0 66.9 1F 33561.2 GF 36269.2 Storey Level Additional Overturning Moment Moment (kip-ft) (kip-ft) F.S 796.39 73074.2 84223.7 20.0 1850896 847.479 82915.1 94779.8 19.5 66.9 2020826 896.174 93353.8 105900.2 19.1 66.8 2180924 917.973 101152.0 110331.8 19.8 Table B.18. Checking for Overturning Moment in Y-direction for Yangon Storey Level Total D.L (kips) C.M.M Resisting Moment (kip-ft) Additional Overturning Moment Moment (kip-ft) (kip-ft) Vy RF-1 195.6 50.1728 8831.788 20.209 161.7 323.3 27.3 RF 1675.8 50.1324 75609.92 141.702 1572.8 2989.8 25.3 14F 3521.9 50.1051 158819.5 262.649 4179.9 6806.4 23.3 13F 5368.1 50.0881 241988.2 346.35 7577.4 11040.9 21.9 12F 7248.5 50.0865 326746.8 409.384 11507.4 15601.3 20.9 11F 9230.0 50.0828 416036.5 465.204 15858.4 20510.5 20.3 10F 11346.5 50.076 511368.1 519.137 21573.5 27803.1 18.4 9F 13346.1 50.1026 601805.4 561.69 27704.8 34445.1 17.5 8F 15359.7 50.1019 692596.9 599.208 34169.5 41360.0 16.7 7F 17452.7 50.0977 786907.4 634.872 40926.2 48544.7 16.2 6F 19537.6 50.0992 880936 668.254 47955.8 55974.9 15.7 5F 22332.7 50.076 1006500 714.937 56511.7 66520.8 15.1 4F 25098.9 50.6142 1143323 764.658 65520.3 76225.5 15.0 3F 27917.9 50.6077 1271573 813.91 75036.4 86431.1 14.7 2F 30739.0 50.601 1399883 866.651 85114.7 97247.9 14.4 1F 33561.2 50.6025 1528451 914.78 95803.0 108609.9 14.1 GF 36269.2 50.2416 1639999 934.846 103779.0 113127.5 14.5 F.S Table B.19. Checking for Torsional Irregularity in X-direction for Nay Pyi Taw Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark RF 0.35332 0.35332 0.35332 0.35332 1 OK 14F 0.34233 0.34233 0.34233 0.34233 1 OK 97 Table B.19. Checking for Torsional Irregularity in X-direction for Nay Pyi Taw (Continued) Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark 13F 0.3294 0.3294 0.3294 0.3294 1 OK 12F 0.31471 0.31471 0.31471 0.31471 1 OK 11F 0.29902 0.29902 0.29902 0.29902 1 OK 10F 0.28265 0.28265 0.28265 0.28265 1 OK 9F 0.26034 0.26034 0.26034 0.26034 1 OK 8F 0.236 0.236 0.236 0.236 1 OK 7F 0.21123 0.21123 0.21123 0.21123 1 OK 6F 0.18657 0.18657 0.18657 0.18657 1 OK 5F 0.16135 0.16135 0.16135 0.16135 1 OK 4F 0.13102 0.13102 0.13102 0.13102 1 OK 3F 0.09941 0.09941 0.09941 0.09941 1 OK 2F 0.06848 0.06848 0.06848 0.06848 1 OK 1F 0.0387 0.0387 0.0387 0.0387 1 OK GF 0.01193 0.01193 0.01193 0.01193 1 OK Table B.20. Checking for Torsional Irregularity in Y-direction for Nay Pyi Taw Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark RF 0.33359 0.33359 0.33359 0.33359 1 OK 14F 0.32374 0.32374 0.32374 0.32374 1 OK 13F 0.31215 0.31215 0.31215 0.31215 1 OK 12F 0.29894 0.29894 0.29894 0.29894 1 OK 11F 0.28475 0.28475 0.28475 0.28475 1 OK 10F 0.26984 0.26984 0.26984 0.26984 1 OK 9F 0.24933 0.24933 0.24933 0.24933 1 OK 8F 0.22673 0.22673 0.22673 0.22673 1 OK 7F 0.20329 0.20329 0.20329 0.20329 1 OK 6F 0.17992 0.17992 0.17992 0.17992 1 OK 5F 0.15661 0.15661 0.15661 0.15661 1 OK 4F 0.12864 0.12864 0.12864 0.12864 1 OK 3F 0.09927 0.09927 0.09927 0.09927 1 OK 2F 0.06959 0.06959 0.06959 0.06959 1 OK 98 Table B.20. Checking for Torsional Irregularity in Y-direction for Nay Pyi Taw (Continued) Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark 1F 0.03987 0.03987 0.03987 0.03987 1 OK GF 0.01242 0.01242 0.01242 0.01242 1 OK Table B.21. Checking for Torsional Irregularity in X-direction for Taunggyi Storey Level RF 14F 13F 12F 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F GF Displacement Displacement Δ1 (in) Δ2 (in) 0.24572 0.2378 0.22857 0.21818 0.2072 0.19584 0.18049 0.16386 0.14703 0.13029 0.11312 0.0923 0.07039 0.04874 0.02767 0.00855 0.24572 0.2378 0.22857 0.21818 0.2072 0.19584 0.18049 0.16386 0.14703 0.13029 0.11312 0.0923 0.07039 0.04874 0.02767 0.00855 Δavg (in) Δmax (in) Δmax ΔAvg Remark 0.24572 0.2378 0.22857 0.21818 0.2072 0.19584 0.18049 0.16386 0.14703 0.13029 0.11312 0.0923 0.07039 0.04874 0.02767 0.00855 0.24572 0.2378 0.22857 0.21818 0.2072 0.19584 0.18049 0.16386 0.14703 0.13029 0.11312 0.0923 0.07039 0.04874 0.02767 0.00855 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK Table B.22. Checking for Torsional Irregularity in Y-direction for Taunggyi Storey Level RF 14F 13F 12F 11F 10F Displacement Displacement Δ1 (in) Δ2 (in) 0.23758 0.23031 0.22182 0.21223 0.20204 0.19143 0.23758 0.23031 0.22182 0.21223 0.20204 0.19143 Δavg (in) Δmax (in) Δmax ΔAvg Remark 0.23758 0.23031 0.22182 0.21223 0.20204 0.19143 0.23758 0.23031 0.22182 0.21223 0.20204 0.19143 1 1 1 1 1 1 OK OK OK OK OK OK 99 Table B.22. Checking for Torsional Irregularity in Y-direction for Taunggyi (Continued) Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark 9F 0.17697 0.17697 0.17697 0.17697 1 OK 8F 0.16118 0.16118 0.16118 0.16118 1 OK 7F 0.1449 0.1449 0.1449 0.1449 1 OK 6F 0.12871 0.12871 0.12871 0.12871 1 OK 5F 0.11252 0.11252 0.11252 0.11252 1 OK 4F 0.09292 0.09292 0.09292 0.09292 1 OK 3F 0.07211 0.07211 0.07211 0.07211 1 OK 2F 0.05081 0.05081 0.05081 0.05081 1 OK 1F 0.02923 0.02923 0.02923 0.02923 1 OK GF 0.00913 0.00913 0.00913 0.00913 1 OK Table B.23. Checking for Torsional Irregularity in X-direction for Yangon Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark RF 0.15003 0.15003 0.15003 0.15003 1 OK 14F 0.14513 0.14513 0.14513 0.14513 1 OK 13F 0.13946 0.13946 0.13946 0.13946 1 OK 12F 0.13312 0.13312 0.13312 0.13312 1 OK 11F 0.12644 0.12644 0.12644 0.12644 1 OK 10F 0.11953 0.11953 0.11953 0.11953 1 OK 9F 0.11018 0.11018 0.11018 0.11018 1 OK 8F 0.10003 0.10003 0.10003 0.10003 1 OK 7F 0.08975 0.08975 0.08975 0.08975 1 OK 6F 0.07953 0.07953 0.07953 0.07953 1 OK 5F 0.06908 0.06908 0.06908 0.06908 1 OK 4F 0.05645 0.05645 0.05645 0.05645 1 OK 3F 0.04319 0.04319 0.04319 0.04319 1 OK 2F 0.03004 0.03004 0.03004 0.03004 1 OK 1F 0.01714 0.01714 0.01714 0.01714 1 OK GF 0.00532 0.00532 0.00532 0.00532 1 OK 100 Table B.24. Checking for Torsional Irregularity in Y-direction for Yangon Storey Level Displacement Displacement Δ1 (in) Δ2 (in) Δavg (in) Δmax (in) Δmax ΔAvg Remark RF 0.14503 0.14503 0.14503 0.14503 1 OK 14F 0.14053 0.14053 0.14053 0.14053 1 OK 13F 0.13531 0.13531 0.13531 0.13531 1 OK 12F 0.12945 0.12945 0.12945 0.12945 1 OK 11F 0.12325 0.12325 0.12325 0.12325 1 OK 10F 0.11679 0.11679 0.11679 0.11679 1 OK 9F 0.10798 0.10798 0.10798 0.10798 1 OK 8F 0.09835 0.09835 0.09835 0.09835 1 OK 7F 0.08841 0.08841 0.08841 0.08841 1 OK 6F 0.07853 0.07853 0.07853 0.07853 1 OK 5F 0.06868 0.06868 0.06868 0.06868 1 OK 4F 0.05678 0.05678 0.05678 0.05678 1 OK 3F 0.04416 0.04416 0.04416 0.04416 1 OK 2F 0.03123 0.03123 0.03123 0.03123 1 OK 1F 0.01804 0.01804 0.01804 0.01804 1 OK GF 0.00566 0.00566 0.00566 0.00566 1 OK Table B.25. Checking for Soft Storey in X-direction for Nay Pyi Taw (Case I) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.001 0.001 No 0.00157 0.00110 0.00133 No 10 0.00177 0.00124 0.00157 No 12F 10 0.00186 0.00130 0.00177 No 11F 10 0.00189 0.00132 0.00186 No 10F 12 0.00210 0.00147 0.00189 No 9F 12 0.00226 0.00158 0.0021 No 8F 12 0.00225 0.00158 0.00226 No 7F 12 0.00220 0.00154 0.00225 No 6F 12 0.00220 0.00154 0.0022 No 5F 14 0.00223 0.00156 0.0022 No 4F 14 0.00229 0.00160 0.00223 No Storey Level Height (ft) Storey Drift Ratio RF-1 8 0.0008 0.00057 RF 10 0.00133 14F 10 13F 70% ( 101 Table B.25. Checking for Soft Storey in X-direction for Nay Pyi Taw (Case I)(Contiued) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.00222 0.00156 0.00229 No 14 0.00213 0.00149 0.00222 No 1F 14 0.00191 0.00134 0.00213 No GF 10 0.00119 0.00083 0.00191 No Storey Level Height (ft) Storey Drift Ratio 3F 14 2F 70% ( Table B.26. Checking for Soft Storey in Y-direction for Nay Pyi Taw (Case I) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.001 0.001 No 0.0014 0.000965 0.00117 No 10 0.0016 0.001095 0.00138 No 12F 10 0.0017 0.001158 0.00156 No 11F 10 0.0017 0.001194 0.00165 No 10F 12 0.0019 0.001344 0.00171 No 9F 12 0.0021 0.00146 0.00192 No 8F 12 0.0021 0.001488 0.00209 No 7F 12 0.0021 0.001457 0.00213 No 6F 12 0.0020 0.001427 0.00208 No 5F 14 0.0021 0.001439 0.00204 No 4F 14 0.0021 0.00149 0.00206 No 3F 14 0.0021 0.001493 0.00213 No 2F 14 0.0021 0.001488 0.00213 No 1F 14 0.0020 0.001373 0.00213 No GF 10 0.0012 0.000869 0.00196 No Storey Level Height (ft) Storey Drift Ratio RF-1 8 0.0008 0.00055 RF 10 0.0012 14F 10 13F 70% ( Table B.27. Checking for Soft Storey in X-direction for Taunggyi (Case I) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.001 0.001 No 0.00084 0.00102 No Storey Level Height (ft) Storey Drift Ratio RF-1 8 0.0006 0.00044 RF 10 0.00102 14F 10 0.00120 70% ( 102 Table B.27. Checking for Soft Storey in X-direction for Taunggyi (Case I) (Continued) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.00134 0.00093 0.0012 No 10 0.00138 0.00097 0.00134 No 11F 10 0.00139 0.00097 0.00138 No 10F 12 0.00152 0.00106 0.00139 No 9F 12 0.00161 0.00113 0.00152 No 8F 12 0.00160 0.00112 0.00161 No 7F 12 0.00154 0.00108 0.0016 No 6F 12 0.00153 0.00107 0.00154 No 5F 14 0.00155 0.00108 0.00153 No 4F 14 0.00160 0.00112 0.00155 No 3F 14 0.00156 0.00109 0.0016 No 2F 14 0.00151 0.00106 0.00156 No 1F 14 0.00137 0.00096 0.00151 No GF 10 0.00086 0.0006 0.00137 No Storey Level Height (ft) Storey Drift Ratio 13F 10 12F 70% ( Table B.28. Checking for Soft Storey in Y-direction for Taunggyi (Case I) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.0006 0.00063 No 0.00108 0.000756 0.00092 No 10 0.00121 0.00085 0.00108 No 12F 10 0.00127 0.000887 0.00121 No 11F 10 0.00129 0.000902 0.00127 No 10F 12 0.00143 0.001002 0.00129 No 9F 12 0.00154 0.001075 0.00143 No 8F 12 0.00155 0.001082 0.00154 No 7F 12 0.0015 0.001048 0.00155 No 6F 12 0.00145 0.001018 0.0015 No 5F 14 0.00146 0.001024 0.00145 No 4F 14 0.00152 0.001064 0.00146 No 3F 14 0.00154 0.001075 0.00152 No 2F 14 0.00155 0.001082 0.00154 No Storey Level Height (ft) Storey Drift Ratio RF-1 8 0.00063 0.000439 RF 10 0.00092 14F 10 13F 70% ( 103 Table B.28. Checking for Soft Storey in Y-direction for Taunggyi (Case I) (Continued) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.00144 0.001005 0.00155 No 0.00091 0.000639 0.00144 No Storey Level Height (ft) Storey Drift Ratio 1F 14 GF 10 70% ( Table B.29. Checking for Soft Storey in X-direction for Yangon (Case I) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.0004 0.00042 No 0.00077 0.00054 0.00067 No 10 0.00085 0.00059 0.00077 No 12F 10 0.00086 0.0006 0.00085 No 11F 10 0.00086 0.0006 0.00086 No 10F 12 0.00093 0.00065 0.00086 No 9F 12 0.00099 0.00069 0.00093 No 8F 12 0.00098 0.00069 0.00099 No 7F 12 0.00095 0.00067 0.00098 No 6F 12 0.00095 0.00066 0.00095 No 5F 14 0.00095 0.00067 0.00095 No 4F 14 0.00098 0.00069 0.00095 No 3F 14 0.00096 0.00067 0.00098 No 2F 14 0.00093 0.00065 0.00096 No 1F 14 0.00084 0.00059 0.00093 No GF 10 0.00053 0.00037 0.00084 No Storey Level Height (ft) Storey Drift Ratio RF-1 8 0.0004 0.00029 RF 10 0.00067 14F 10 13F 70% ( Table B.30. Checking for Soft Storey in Y-direction for Yangon (Case I) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.000417 0.00042 No 0.0007 0.000488 0.0006 No 10 0.00077 0.00054 0.0007 No 10 0.00079 0.000554 0.00077 No Storey Level Height (ft) Storey Drift Ratio RF-1 8 0.00042 0.000294 RF 10 0.0006 14F 10 13F 12F 70% ( 104 Table B.30. Checking for Soft Storey in Y-direction for Yangon (Case I) (Continued) Δ1 ) h1 Δ2 - Δ1 h2 Soft Storey Status 0.0008 0.000557 0.00079 No 12 0.00088 0.000615 0.0008 No 9F 12 0.00094 0.000659 0.00088 No 8F 12 0.00095 0.000666 0.00094 No 7F 12 0.00092 0.000647 0.00095 No 6F 12 0.0009 0.000629 0.00092 No 5F 14 0.0009 0.000631 0.0009 No 4F 14 0.00093 0.000652 0.0009 No 3F 14 0.00094 0.000657 0.00093 No 2F 14 0.00095 0.000662 0.00094 No 1F 14 0.00089 0.00062 0.00095 No GF 10 0.00057 0.000396 0.00089 No Storey Level Height (ft) Storey Drift Ratio 11F 10 10F 70% ( Table B.31. Checking for Soft Storey in X-direction for Nay Pyi Taw (Case II) Δ1 ) h1 Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.001 0.00124 No 0.00186 0.00148 0.00156 No 10 0.00189 0.00151 0.00173 No 10F 12 0.0021 0.00168 0.00184 No 9F 12 0.00226 0.00180 0.00195 No 8F 12 0.00225 0.00180 0.00208 No 7F 12 0.0022 0.00176 0.0022 No 6F 12 0.0022 0.00176 0.00223 No 5F 14 0.00223 0.00178 0.00222 No 4F 14 0.00229 0.00183 0.00221 No 3F 14 0.00222 0.00178 0.00224 No 2F 14 0.00213 0.00170 0.00225 No 1F 14 0.00191 0.00153 0.00221 No GF 10 0.00119 0.00095 0.00209 No Storey Level Height Storey Drift Ratio RF-1 8 0.00081 0.00065 RF 10 0.00133 0.00107 14F 10 0.00157 0.00126 13F 10 0.00177 12F 10 11F 80% ( 105 Table B.32. Checking for Soft Storey in Y-direction for Nay Pyi Taw (Case II) Δ1 ) h1 Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.001 0.00111 No 0.0017 0.00132 0.00137 No 10 0.0017 0.00136 0.00153 No 10F 12 0.0019 0.00154 0.00164 No 9F 12 0.0021 0.00167 0.00176 No 8F 12 0.0021 0.0017 0.0019 No 7F 12 0.0021 0.00167 0.00204 No 6F 12 0.0020 0.00163 0.0021 No 5F 14 0.0021 0.00164 0.00208 No 4F 14 0.0021 0.0017 0.00206 No 3F 14 0.0021 0.00171 0.00207 No 2F 14 0.0021 0.0017 0.00211 No 1F 14 0.0020 0.00157 0.00213 No GF 10 0.0012 0.00099 0.00207 No Storey Level Height Storey Drift Ratio RF-1 8 0.0008 0.00063 RF 10 0.00117 0.00093 14F 10 0.0014 0.0011 13F 10 0.002 12F 10 11F 80% ( Table B.33. Checking for Soft Storey in X-direction for Taunggyi (Case II) Δ1 ) h1 Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.0010 0.001 No 0.00138 0.0011 0.00118 No 10 0.00139 0.00111 0.0013 No 10F 12 0.00152 0.00122 0.00137 No 9F 12 0.00161 0.00129 0.00143 No 8F 12 0.0016 0.00128 0.00151 No 7F 12 0.00154 0.00123 0.00158 No 6F 12 0.00153 0.00123 0.00158 No Storey Level Height Storey Drift Ratio RF-1 8 0.00063 0.0005 RF 10 0.00102 0.00082 14F 10 0.0012 0.00096 13F 10 0.00134 12F 10 11F 80% ( 106 Table B.33. Checking for Soft Storey in X-direction for Taunggyi (Case II)(Continued) Δ1 ) h1 Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.00155 0.00124 0.00156 No 14 0.0016 0.00128 0.00154 No 3F 14 0.00156 0.00125 0.00156 No 2F 14 0.00151 0.00121 0.00157 No 1F 14 0.00137 0.00109 0.00156 No GF 10 0.00086 0.00068 0.00148 No Storey Level Height Storey Drift Ratio 5F 14 4F 80% ( Table B.34. Checking for Soft Storey in Y-direction for Taunggyi (Case II) Δ1 ) h1 Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.001 0.001 No 0.00127 0.00101 0.00107 No 10 0.00129 0.00103 0.00119 No 10F 12 0.00143 0.00115 0.00126 No 9F 12 0.00154 0.00123 0.00133 No 8F 12 0.00155 0.00124 0.00142 No 7F 12 0.0015 0.0012 0.0015 No 6F 12 0.00145 0.00116 0.00153 No 5F 14 0.00146 0.00117 0.0015 No 4F 14 0.00152 0.00122 0.00147 No 3F 14 0.00154 0.00123 0.00148 No 2F 14 0.00155 0.00124 0.00151 No 1F 14 0.00144 0.00115 0.00153 No GF 10 0.00091 0.00073 0.00151 No Storey Level Height Storey Drift Ratio RF-1 8 0.00063 0.0005 RF 10 0.00092 0.00073 14F 10 0.00108 0.00086 13F 10 0.00121 12F 10 11F 80% ( Table B.35. Checking for Soft Storey in X-direction for Yangon (Case II) Storey Level Height Storey Drift Ratio RF-1 8 0.00042 80% ( Δ1 ) h1 0.00034 Δ1 +Δ2 +Δ3 3h Soft Storey Status 107 Table B.35. Checking for Soft Storey in X-direction for Yangon (Case II) (Continued) Storey Level Height Storey Drift Ratio RF 10 0.00067 Δ1 ) h1 0.00053 14F 10 0.00077 0.00062 13F 10 0.00085 12F 10 11F Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.0006 0.00062 No 0.00086 0.00069 0.00076 No 10 0.00086 0.00068 0.00083 No 10F 12 0.00093 0.00075 0.00086 No 9F 12 0.00099 0.00079 0.00088 No 8F 12 0.00098 0.00079 0.00093 No 7F 12 0.00095 0.00076 0.00097 No 6F 12 0.00095 0.00076 0.00098 No 5F 14 0.00095 0.00076 0.00096 No 4F 14 0.00098 0.00078 0.00095 No 3F 14 0.00096 0.00076 0.00096 No 2F 14 0.00093 0.00074 0.00096 No 1F 14 0.00084 0.00068 0.00095 No GF 10 0.00053 0.00043 0.00091 No 80% ( Table B.36. Checking for Soft Storey in Y-direction for Yangon (Case II) Δ1 ) h1 Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.0006 0.0006 No 0.00079 0.00063 0.00069 No 10 0.0008 0.00064 0.00075 No 10F 12 0.00088 0.0007 0.00079 No 9F 12 0.00094 0.00075 0.00082 No 8F 12 0.00095 0.00076 0.00087 No 7F 12 0.00092 0.00074 0.00092 No 6F 12 0.0009 0.00072 0.00094 No 5F 14 0.0009 0.00072 0.00092 No 4F 14 0.00093 0.00075 0.00091 No Storey Level Height Storey Drift Ratio RF-1 8 0.00042 0.00034 RF 10 0.0006 0.00048 14F 10 0.0007 0.00056 13F 10 0.00077 12F 10 11F 80% ( 108 Table B.36. Checking for Soft Storey in Y-direction for Yangon (Case II) (Continued) Δ1 ) h1 Δ1 +Δ2 +Δ3 3h Soft Storey Status 0.00094 0.00075 0.00091 No 14 0.00095 0.00076 0.00092 No 1F 14 0.00089 0.00071 0.00094 No GF 10 0.00057 0.00045 0.00092 No Storey Level Height Storey Drift Ratio 3F 14 2F 80% ( Table B.37. Checking for Sliding in X-direction for Nay Pyi Taw Storey Height (ft) Total DL (kips) Vx (kips) RF 10 1675.783 248.69 Resistance due to friction (kips) 377.05 14F 10 3521.92 486.04 13F 10 5368.057 12F 10 11F Sliding Force (kips) S.F Remark 248.69 1.52 OK 792.43 486.04 1.63 OK 677.54 1207.81 677.54 1.78 OK 7248.5 839.66 1630.91 839.66 1.94 OK 10 9229.97 984.41 2076.74 984.41 2.11 OK 10F 12 11346.49 1119.91 2552.96 1119.91 2.28 OK 9F 12 13346.07 1228.93 3002.87 1228.93 2.44 OK 8F 12 15359.74 1322.90 3455.94 1322.90 2.61 OK 7F 12 17452.73 1411.43 3926.86 1411.43 2.78 OK 6F 12 19537.59 1498.25 4395.96 1498.25 2.93 OK 5F 14 22332.73 1614.18 5024.86 1614.18 3.11 OK 4F 14 25098.87 1731.07 5647.25 1731.07 3.26 OK 3F 14 27917.87 1839.77 6281.52 1839.77 3.41 OK 2F 14 30739.02 1933.52 6916.28 1933.52 3.58 OK 1F 14 33561.17 2002.08 7551.26 2002.08 3.77 OK GF 10 36269.17 2028.02 8160.56 2028.02 4.02 OK Table B.38. Checking for Sliding in Y-direction for Nay Pyi Taw Height Storey (ft) Total DL (kips) Vx (kips) Resistance due to friction (kips) RF 10 1675.78 237.13 377.05 237.13 1.59 OK 14F 10 3521.92 470.10 792.43 470.10 1.69 OK 13F 10 5368.06 660.86 1207.81 660.86 1.83 OK Sliding Force (kips) S.F Remark 109 Table B.38. Checking for Sliding in Y-direction for Nay Pyi Taw (Continued) Storey Height (ft) Total DL (kips) Vx (kips) Resistance due to friction (kips) 12F 10 7248.50 824.23 1630.91 824.23 1.98 OK 11F 10 9229.97 972.74 2076.74 972.74 2.13 OK 10F 12 11346.49 1112.46 2552.96 1112.46 2.29 OK 9F 12 13346.07 1224.56 3002.87 1224.56 2.45 OK 8F 12 15359.74 1321.53 3455.94 1321.53 2.62 OK 7F 12 17452.73 1411.78 3926.86 1411.78 2.78 OK 6F 12 19537.59 1498.10 4395.96 1498.10 2.93 OK 5F 14 22332.73 1613.54 5024.86 1613.54 3.11 OK 4F 14 25098.87 1730.54 5647.25 1730.54 3.26 OK 3F 14 27917.87 1839.27 6281.52 1839.27 3.42 OK 2F 14 30739.02 1934.23 6916.28 1934.23 3.58 OK 1F 14 33561.17 2002.84 7551.26 2002.84 3.77 OK GF 10 36269.17 2027.98 8160.56 2027.98 4.02 OK Sliding Force (kips) S.F Remark Table B.39. Checking for Sliding in X-direction for Taunggyi Height Storey (ft) Total DL (kips) Vx (kips) Resistance due to friction (kips) Sliding Force (kips) S.F Remark RF 10 1675.78 202.96 377.05 202.96 1.86 OK 14F 10 3521.92 385.52 792.43 385.52 2.06 OK 13F 10 5368.06 524.73 1207.81 524.73 2.30 OK 12F 10 7248.50 636.80 1630.91 636.80 2.56 OK 11F 10 9229.97 732.28 2076.74 732.28 2.84 OK 10F 12 11346.49 819.12 2552.96 819.12 3.12 OK 9F 12 13346.07 886.14 3002.87 886.14 3.39 OK 8F 12 15359.74 941.60 3455.94 941.60 3.67 OK 7F 12 17452.73 994.28 3926.86 994.28 3.95 OK 6F 12 19537.59 1048.96 4395.96 1048.96 4.19 OK 5F 14 22332.73 1127.71 5024.86 1127.71 4.46 OK 4F 14 25098.87 1213.34 5647.25 1213.34 4.65 OK 3F 14 27917.87 1298.65 6281.52 1298.65 4.84 OK 110 Table B.39. Checking for Sliding in X-direction for Taunggyi (Continued) Total DL (kips) Vx (kips) Resistance due to friction (kips) Sliding Force (kips) S.F Remark Storey Height (ft) 2F 14 30738.72 1377.01 6916.21 1377.01 5.02 OK 1F 14 33560.57 1438.81 7551.13 1438.81 5.25 OK GF 10 36268.57 1463.54 8160.43 1463.54 5.58 OK Table B.40. Checking for Sliding in Y-direction for Taunggyi Height Storey (ft) Total DL (kips) Vx (kips) Resistance due to friction (kips) RF 10 1675.78 198.30 377.05 198.30 1.90 OK 14F 10 3521.92 384.38 792.43 384.38 2.06 OK 13F 10 5368.06 528.48 1207.81 528.48 2.29 OK 12F 10 7248.50 645.31 1630.91 645.31 2.53 OK 11F 10 9229.97 747.05 2076.74 747.05 2.78 OK 10F 12 11346.49 839.35 2552.96 839.35 3.04 OK 9F 12 13346.07 908.68 3002.87 908.68 3.30 OK 8F 12 15359.74 965.94 3455.94 965.94 3.58 OK 7F 12 17452.73 1019.33 3926.86 1019.33 3.85 OK 6F 12 19537.59 1072.77 4395.96 1072.77 4.10 OK 5F 14 22332.73 1152.06 5024.86 1152.06 4.36 OK 4F 14 25098.87 1240.51 5647.25 1240.51 4.55 OK 3F 14 27917.87 1328.43 6281.52 1328.43 4.73 OK 2F 14 30738.72 1410.83 6916.21 1410.83 4.90 OK 1F 14 33560.57 1474.38 7551.13 1474.38 5.12 OK GF 10 36268.57 1498.54 8160.43 1498.54 5.45 OK Sliding Force (kips) S.F Remark Table B.41. Checking for Sliding in X-direction for Yangon Height Storey (ft) Total DL (kips) Vx (kips) Resistance due to friction (kips) RF 10 1675.78 147.02 377.05 147.02 2.56 OK 14F 10 3521.92 265.03 792.43 265.03 2.99 OK Sliding Force (kips) S.F Remark 111 Table B.41. Checking for Sliding in X-direction for Yangon (Continued) Storey Height (ft) Total DL (kips) Vx (kips) Resistance due to friction (kips) 13F 10 5368.06 344.77 1207.81 344.77 3.50 OK 12F 10 7248.50 404.63 1630.91 404.63 4.03 OK 11F 10 9229.97 455.90 2076.74 455.90 4.56 OK 10F 12 11346.49 506.49 2552.96 506.49 5.04 OK 9F 12 13346.07 549.07 3002.87 549.07 5.47 OK 8F 12 15359.74 586.16 3455.94 586.16 5.90 OK 7F 12 17452.73 621.40 3926.86 621.40 6.32 OK 6F 12 19537.59 655.86 4395.96 655.86 6.70 OK 5F 14 22332.73 701.18 5024.86 701.18 7.17 OK 4F 14 25098.87 747.93 5647.25 747.93 7.55 OK 3F 14 27917.87 796.39 6281.52 796.39 7.89 OK 2F 14 30739.02 847.48 6916.28 847.48 8.16 OK 1F 14 33561.17 896.17 7551.26 896.17 8.43 OK GF 10 36269.17 917.97 8160.56 917.97 8.89 OK Sliding Force (kips) S.F Remark Table B.42. Checking for Sliding in Y-direction for Yangon Height Storey (ft) Total DL (kips) Vx (kips) Resistance due to friction (kips) Sliding Force (kips) S.F Remark RF 10 1675.78 141.70 377.05 141.70 2.66 OK 14F 10 3521.92 262.65 792.43 262.65 3.02 OK 13F 10 5368.06 346.35 1207.81 346.35 3.49 OK 12F 10 7248.50 409.38 1630.91 409.38 3.98 OK 11F 10 9229.97 465.20 2076.74 465.20 4.46 OK 10F 12 11346.49 519.14 2552.96 519.14 4.92 OK 9F 12 13346.07 561.69 3002.87 561.69 5.35 OK 8F 12 15359.74 599.21 3455.94 599.21 5.77 OK 7F 12 17452.73 634.87 3926.86 634.87 6.19 OK 6F 12 19537.59 668.25 4395.96 668.25 6.58 OK 5F 14 22332.73 714.94 5024.86 714.94 7.03 OK 4F 14 25098.87 764.66 5647.25 764.66 7.39 OK 112 Table B.42. Checking for Sliding in Y-direction for Yangon Storey Height (ft) Total DL (kips) Vx (kips) Resistance due to friction (kips) 3F 14 27917.87 813.91 6281.52 813.91 7.72 OK 2F 14 30739.02 866.65 6916.28 866.65 7.98 OK 1F 14 33561.17 914.78 7551.26 914.78 8.25 OK GF 10 36269.17 934.85 8160.56 934.85 8.73 OK Sliding Force (kips) S.F Remark APPENDIX C STRUCTURAL FRAMING SYSTEM Figure C.1. 3D View of the Structure Figure C.2. Architectural Plan of Car Parking Floor (Ground Floor) 114 Figure C.3. Architectural Plan of Shopping Area Floor (1st to 4th Floor) Figure C.4. Architectural Plan of Office Area Floor (5th to 9th Floor) 115 Figure C.5. Architectural Plan of Residential Floor (10th to 14th Floor) LIST OF PUBLICATIONS 1. Thae Thae Su Win, Phyoe Hnin Thu Htun and San Lwin: Comparative study on Structural Behaviour of RC Building with Vertical Geometric Irregularity at Bago and Taunggyi Seismic Locations, Mandalay Technological University of Science, Engineering and Technology, (MTUJSET), Volume 8, December 2021, 45-50. 2.
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )