Suction Lift & The
Centrifugal Pump
ANDY WILSON
BUSINESS DEVELOPMENT MANAGER
PUMP CENTRE CONFERENCE 2016
Suction Lift & The Centrifugal Pump
Suction Lift ?
No Such Thing
Centrifugal pumps push they don’t pull
Suction Push (By Atmospheric Pressure)
Low pressure inside pump casing is equalised by
atmospheric pressure pushing liquid from a higher to lower
pressure area
Suction Lift Limits
Hb = Atmospheric Pressure at pump site
is the theoretical maximum suction lift.
Hs = Safety Factor ( 0.5 – 2m)
Hv = Vapour Pressure (varies with 0C)
Hfs= Friction Loss in Suction
NPSHr = Required by pump
Hmax = Maximum Suction Static Head
Net Positive Suction Head - NPSH
In order for atmospheric pressure to push liquid into the
pump – NPSHavailable > NPSHrequired
NPSHa = Atmospheric Pressure – Friction Head - Vapour Pressure - Safety Factor - Suction Static Head
NPSHa = Hb - Hfs - Hv –Hs - Hmax
(most of these parameters are fixed but you can influence friction losses)
NPSHr is a value indicated on manufacturers Pump Curve at Duty Point
Minimise Suction Losses – Hf
No valves (reduces risk of air entering suction line) or mount stem horizontally
Minimum bends ( tapers and bends ideally min x 5 pipe diameters from pump suction)
Shortest pipe run ( get pump closest to pump media)
Oversize pipe – ensure velocity in suction pipe < pump suction connection
What is Cavitation
Low Pressure Boiling
Cavitation
Reliability Comes With Good Integrity
Ensure atmospheric
pressure only has one way
in – up the suction pipe
Ensure pipework has no
leaks
Avoid valves on suction
side of the pump
Submerged spring loaded
loaded foot valves can
work on high pressure
clean water systems
Reliability Comes With Good Integrity
Isolation valves may allow
atmospheric air ingress via
valve stems
Mechanical seals leak both
ways – air can get in when
pump not operating.
Double mechanical seals
with oil lubricant chamber
buffer air ingress
No high points above pump
centre line on suction pipe
profile
Seal Chamber air filled
with water lubricated
single mechanical seal
design
Seal Chamber oil filled
with double mechanical seal
design
Common Types of Priming System
Diaphragm Hand Primer
Static Prime Tanks
Common Types of Priming System
Vacuum Pumps – Many Types
Venturi Ejectors/
Recirculation
Can Suction Lift Be Reliable
Thousands of Vacuum Pump
Assisted Mobile Sets
Static Prime on Sewage 1967 to date
Everland Road Hungerford 1968
What Can Go Wrong
Cavitation/Low Pressure
Boiling
Air locks – due to high
point on suction line,
valves not horizontal
Pipe joint integrity poor
Swirl – too many elbows
– Aim for single elbow
minimum 5 pipe
diameters from pump
suction
Poor Design
Poor Installation
Suction Lift Limits
NPSHa – Do the
calculation.
Type of pump media
Liquid temperature &
vapour pressure
Altitude
Friction Loss
Static Loss
Good Totex Solution For Some Sites
New Builds
Retro Fit – No Dig
No Dig – Above Ground
“Bail out” systems for
CDM Regs – Good Compliance
unreliable sites foul or storm
water
Emergency overflows
protection as opposed to 4 hour
storage chamber construction
Transfer stations
Avoids lifting & chain costs/ re-
certification
Improved H&S environment –
easier access no confined space
Offsite manufacture possible
Standard TEFC motors possible
Totex Advantages
Capex
Opex
Above Ground Manufacturing
Easier environment to
– Lower Civil Costs
Reduced Zoning - Atex
requirement
Offsite manufacturing
controlled program and cost
benefits
maintain within & improved
H&S
Use of TEFC high efficiency
motors - Quicker and less
expensive to repair than
submersible motors
No contract lifts out of wet
wells
Reduced Atex requirement